Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

(NOICE) Neural Optical Image Categorizer for the E-log

The Fermilab Accelerator Division Electronic logbook (E-log) is a record of all the activities and events in the Division for the past 10 years and more. The E-log search function is a valuable resource and the institutional memory of the accelerator complex. About 300,000 files are stored in the E-log, of which the vast majority are images attached to entries and comments. The visual information contained in the images is not presently searchable. The goal of team NOICE (Neural Optical Image Categorizer for the E-log) was to design a neural network able to produce label categories for these images for use by searches. The group developed a dataset and trained a convolutional neural network (CNN) with optimized hyperparameter

43 PARTICLE ACCELERATORS↗

Optical image of a cometary nucleus: 1980 flyby of Comet Encke

The feasibility was investigated of obtaining optical images of a cometary nucleus via a flyby of Comet Encke. A physical model of the dust cloud surrounding the nucleus was developed by using available physical data and theoretical knowledge of cometary physics. Using this model and a Mie scattering code, calculations were made of the absolute surface brightness of the dust in the line of sight of the on-board camera and the relative surface brightness of the dust compared to the nucleus. The brightness was calculated as a function of heliocentric distance and for different phase angles (sun-comet-spacecraft angle).

Wells, W. C.↗

Detecting X-rays with an optical imaging chamber

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The different morphologies of photoelectron tracks and minimum ionizing tracks can be used for charged particle rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.↗

Optical imaging chamber for X-ray astronomy

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The differing morphologies of photoelectron tracks and high-energy charged particle tracks can be used for background rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.↗

Optical Imaging Methods for Volumetric Additive Manufacturing

Tomographic volumetric additive manufacturing (VAM) is a technique that enables light-induced curing of photoresins into complex 3D end use objects within a single step. This is made possible through projecting tomographically patterned light energy into a photo-curable resin volume within a rotating container. In order to monitor, quantify, and control curing during tomographic VAM, researchers need to visualize the curing parts in real-time. This may enable advancements toward dynamic, controlled and closedloop VAM methods in the future, as some researchers have shown. Herein we briefly review various optical imaging methods used to monitor printing in real-time, as well as provide some perspectives for future needs and considerations for imaging methods in VAM.

36 MATERIALS SCIENCE↗

Spaceborne astronomy with electro-optical image sensors

The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.

Bradley, W. C.↗

High-speed joint-transform optical image correlator using GaAs/AlGaAs semi-insulating multiple quantum wells and diode lasers

We demonstrate a compact real-time optical image correlator using diode lasers and a semi-insulating GaAs/AlGaAs multiple-quantum-well (SI-MQW) device as the holographic element. With only 3 mW of power incident upon the SI-MQW device, the correlation is obtained in 1 microsec and can be erased in as fast as 2 microsec, which presents the possibility of a system capable of 3 x 10 exp 5 correlations/s. We also show that images can be stored for a controllable length of time (2-25 microsec), which presents possibilities for the use of the SI-MQW device as a data or image buffer memory.

Partovi, A.↗

Antiglare improvement for optical imaging systems

Baffle configuration provides a more efficient shade against interfering sources of illumination outside the desired field of view of optical imaging systems. It consists of a semi-ellipsoid of revolution about the minor axis with black specular reflecting surface and an aperture defined by the locus of the foci of the generating ellipse.

Davis, E. S.↗

Nonlinear Optical Image Processing with Bacteriorhodopsin Films

The transmission properties of some bacteriorhodopsin film spatial light modulators are uniquely suited to allow nonlinear optical image processing operations to be applied to images with multiplicative noise characteristics. A logarithmic amplitude transmission feature of the film permits the conversion of multiplicative noise to additive noise, which may then be linearly filtered out in the Fourier plane of the transformed image. The bacteriorhodopsin film displays the logarithmic amplitude response for write beam intensities spanning a dynamic range greater than 2.0 orders of magnitude. We present experimental results demonstrating the principle and capability for several different image and noise situations, including deterministic noise and speckle. Using the bacteriorhodopsin film, we successfully filter out image noise from the transformed image that cannot be removed from the original image.

Downie, John D.↗

Subaru/HSC deep optical imaging of infrared sources in the AKARI North Ecliptic Pole-Wide field

In this work, we present a five-broad-band (grizy) photometric catalogue of Subaru/Hyper Suprime-Cam (HSC) optical imaging observations at around the North Ecliptic Pole (NEP) where the AKARI infrared (IR) satellite conducted a large survey (NEP-Wide survey). The observations cover almost all the NEP-Wide survey field down to the depth of 28.1, 26.8, 26.3, 25.5, and 25.0 mag (5σ) at grizy, respectively. The five-band HSC catalogue contains about 2.6 million objects, and 70 959 AKARI NEP-Wide counterpart sources are identified in the catalogue. We added existing supplementary catalogues from the u band to the far-IR band, and estimated photo-z for the AKARI-HSC sources. We achieved σΔz/(1 + zs) = 0.06 and an outlier rate of 13.4 per cent at z = 0.2–1.5. Using the spectral energy distribution (SED) template fitting, we classified the AKARI-HSC galaxies into four categories, namely quiescent, star-forming, Type1 active galactic nucleus (AGN), and Type2 AGN, in each redshift bin. Then, at z > 1, the mean SED of star-forming galaxies in mid-IR (3–10 μm) range is significantly different from that of spiral galaxies in the nearby Universe, indicating that many of star-forming galaxies at z > 1 contain a heat source capable of heating dust to temperatures that radiate thermal emission in the mid-IR range. Furthermore, we estimated the number fraction of AGNs (fAGN) in each bin of redshift and IR luminosity (L IR ), and examined the dependence of redshift and L IR . In log(L IR /L ⊙ ) = 11.0–14.0, the fAGN shows a significant increase with increasing redshift, regardless of the LIR bins. In contrast, the fAGN shows a slight increase against L IR at z < 1 and no increase with increasing L IR at z > 1.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection and Estimation of an Optical Image by Photon-Counting Techniques

Statistical description of a photoelectric detector is given. The photosensitive surface of the detector is divided into many small areas, and the moment generating function of the photo-counting statistic is derived for large time-bandwidth product. The detection of a specified optical image in the presence of the background light by using the hypothesis test is discussed. The ideal detector based on the likelihood ratio from a set of numbers of photoelectrons ejected from many small areas of the photosensitive surface is studied and compared with the threshold detector and a simple detector which is based on the likelihood ratio by counting the total number of photoelectrons from a finite area of the surface. The intensity of the image is assumed to be Gaussian distributed spatially against the uniformly distributed background light. The numerical approximation by the method of steepest descent is used, and the calculations of the reliabilities for the detectors are carried out by a digital computer.

Wang, Lily Lee↗

Acousto-Optic Imaging Spectrometers for Mars Surface Science

NASA's long term plan for Mars sample collection and return requires a highly streamlined approach for spectrally characterizing a landing site, documenting the mineralogical make-up of the site and guiding the collections of samples which represent the diversity of the site. Ideally, image data should be acquired at hundreds of VIS and IR wavelengths, in order to separately distinguish numerous anticipated species, using principal component analysis and linear unmixing. Cameras with bore-sighted point spectrometers can acquire spectra of isolated scene elements, but it requires 10(exp 2) to 10(exp 2) successive motions and precise relative pointing knowledge in order to create a single data cube which qualifies as a spectral map. These and other competing science objectives have to be accomplished within very short lander/rover operational lifetime (a few sols). True, 2-D imaging spectroscopy greatly speeds up the data acquisition process, since the spectra of all pixels in the scene are collected at once. This task can be accomplished with cameras that use electronically tunable acousto-optic tunable filters (AOTFs) as the optical tuning element. AOTFs made from TeO2 are now a mature technology, and operate at wavelengths from near-UV to about 5 microns. Because of incremental improvements in the last few years, present generation devices are rugged, radiation-hard and operate at temperatures down to at least 150K so they can be safely integrated into the ambient temperature optics of in-situ instruments such as planetary or small-body landers. They have been used for ground-based astronomy, and were also baselined for the ST-4 Champollion IR comet lander experiment (CIRCLE), prior to cancellation of the ST-4 mission last year. AIMS (for Acousto-optic Imaging spectrometer), is a prototype lander instrument which is being built at GSFC with support by the NASA OSS Advanced Technologies and Mission Studies, Mars Instrument Definition and Development Program (MIDP). AIMS is capable of tunable spectroscopic imaging of surface mineralogy, ices and dust between 0.5 and 2.4 microns, at a resolving power (lambda/delta lambda) which is typically several hundred. The design spatial resolution, similar to IMP and SSI, will allow mapping at scales down to about 1 cm.

Glenar, D. A.↗

Follow-up and Validation of K2 and TESS Planetary Systems with Keck NIRC2 Adaptive Optics Imaging

High resolution imaging (HRI) is a critical part of the transiting exoplanet follow-up and validation process. HRI allows previously unresolved stellar companions and background blends to be resolved, vetting false positive signals and improving the radii measurements of true planets. Through a multi-semester Keck NIRC2 adaptive optics imaging program, we have pursued HRI of K2 and TESS candidate planet host systems to provide the transiting exoplanet community with necessary data for system validation and characterization. Here we present a summary of our ongoing program that includes an up to date list of targets observed, a description of the observations and data reduction, and a discussion of planetary systems validated by the community using these data. This observing program has been key in NASA’s K2 and TESS missions reaching their goals of identifying new exoplanets ideal for continued follow-up observations to measure their masses and investigate their atmospheres. All observations presented here are available as calibrated images and resulting contrast curves through the Exoplanet Follow-up Observing Program (ExoFOP) website. We encourage members of the exoplanet community to use these data products in their ongoing planetary system validation and characterization efforts.

Adaptive optics↗

Ultrafast Metal Electrodeposition Revealed by In Situ Optical Imaging and Theoretical Modeling towards Fast–Charging Zn Battery Chemistry

Metallic Zn is a preferred anode material for rechargeable aqueous batteries towards a smart grid and renewable energy storage. Importantly, understanding how the metal nucleates and grows at the aqueous Zn anode is a critical and challenging step to achieve full reversibility of Zn battery chemistry, especially under fast-charging conditions. Here, by combining in situ optical imaging and theoretical modeling, we uncover the critical parameters governing the electrodeposition stability of the metallic Zn electrode, that is, the competition among crystallographic thermodynamics, kinetics, and Zn 2+ -ion diffusion. Moreover, steady-state Zn metal plating/ stripping with Coulombic efficiency above 99 % is achieved at 10-100 mA cm -2 in a reasonably high concentration (3 M) ZnSO 4 electrolyte. Significantly, a long-term cycling-stable Zn metal electrode is realized with a depth of discharge of 66.7% under 50 mA cm -2 in both Zn || Zn symmetrical cells and MnO 2 || Zn full cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Science Validation for Dark Energy Research with Optical Imaging Surveys

The Universe has been expanding at an accelerating rate over the past several billion years, as though an unknown form of dark energy permeates all of space. The ultimate scientific goal of the proposed research is to distinguish between different physical mechanisms that could account for this observed accelerated expansion, for example, the zero-point energy of the vacuum, a dynamical form of energy that varies in time and/or space, or a modification to our theory of gravity. Wide- field optical imaging surveys of the night sky can test these competing models by measuring both the cosmic expansion history and the growth of large-scale structure. To this end, the Dark Energy Survey (DES) has cataloged several hundred million galaxies and thousands of supernovae. The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), will enlarge the census to billions of galaxies and hundreds of thousands of supernovae. A critical question for these dark energy experiments is whether systematic uncertainties can continue to be controlled at a level to keep pace with the statistical precision offered by such enormous datasets. The immediate research objectives of this project were (1) to prepare and validate input datasets that are the foundation of cosmological analyses with DES, and (2) to prepare for value-added characterization of Rubin Observatory commissioning data to inform early operations and accelerate the realization of dark energy science from LSST data products. For DES, we assembled and curated cosmology-ready data releases that include value-added components such as enhanced photometric and astrometric calibrations, alternative source extraction algorithms, maps of the survey coverage and survey conditions, object classifications, object quality selections, galaxy shapes, and photometric redshifts. We used the galaxy clustering technique to validate the photometric redshift distributions of various galaxy samples to be used as lenses in combined studies of galaxy clustering and weak gravitational lensing. The galaxy clustering redshift analysis was enhanced by use of a larger sample of reference galaxies from the eBOSS spectroscopic survey that extends to higher redshifts. For LSST, we prepared for science validation studies of commissioning data aimed at dark energy science capability that extend beyond the normative system-level tests to be done by the Rubin Observatory Construction Project. We identified a set of proposed survey strategies and candidate target fields that could be observed during the commissioning period to enhance science validation activities related to studies of dark energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular homing and retention of muscle membrane stabilizing copolymers by non-invasive optical imaging in vivo

First-in-class membrane stabilizer Poloxamer 188 (P188) has been shown to confer membrane protection in an extensive range of clinical conditions; however, elements of the systemic distribution and localization of P188 at the organ, tissue, and muscle fiber levels in vivo have not yet been elucidated. Here we used non-invasive fluorescence imaging to directly visualize and track the distribution and localization of P188 in vivo. The results demonstrated that the Alx647 probe did not alter the fundamental properties of P188 to protect biological membranes. Distribution kinetics in mdx mice demonstrated that Alx647 did not interface with muscle membranes and had fast clearance kinetics. In contrast, the distribution kinetics for P188-Alx647 was significantly slower, indicating a dramatic depot and retention effect of P188. Results further demonstrated the significant retention of P188-Alx647 in the skeletal muscle of mdx mice, showing a significant genotype effect with a higher fluorescence signal in the mdx muscles over BL10 mice. High-resolution optical imaging provided direct evidence of P188 surrounding the sarcolemma of skeletal and cardiac muscle cells. Taken together, these findings provide direct evidence of muscle-disease-dependent molecular homing and retention of synthetic copolymers in striated muscles thereby facilitating advanced studies of copolymer-membrane association in health and disease.

60 APPLIED LIFE SCIENCES↗

Sub-pixel high-resolution imaging of high-energy x-rays inspired by sub-wavelength optical imaging

We have developed and demonstrated an image super-resolution method—XR-UNLOC: X-Ray UNsupervised particle LOCalization—for hard x-rays measured with fast-frame-rate detectors that is an adaptation of the principle of photo-activated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), which enabled biological fluorescence imaging at sub-optical-wavelength scales. We demonstrate the approach on experimental coherent Bragg diffraction data measured with 52 keV x-rays from a nanocrystalline sample. From this sample, we resolve the fine fringe detail of a high-energy x-ray Bragg coherent diffraction pattern to an upsampling factor of 16 of the native pixel pitch of 30 μ m of a charge-integrating fastCCD detector. This was accomplished by analysis of individual photon locations in a series of “nearly-dark” instances of the diffraction pattern that each contain only a handful of photons. Central to our approach was the adaptation of the UNLOC photon fitting routine for PALM/STORM to the hard x-ray regime to handle much smaller point spread functions, which required a different statistical test for photon detection and for sub-pixel localization. A comparison to a photon-localization strategy used in the x-ray community (“droplet analysis”) showed that XR-UNLOC provides significant improvement in super-resolution. We also developed a metric by which to estimate the limit of reliable upsampling with XR-UNLOC under a given set of experimental conditions in terms of the signal-to-noise ratio of a photon detection event and the size of the point spread function for guiding future x-ray experiments in many disciplines where detector pixelation limits must be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electro-Optical Imaging Fourier-Transform Spectrometer

An electro-optical (E-O) imaging Fourier-transform spectrometer (IFTS), now under development, is a prototype of improved imaging spectrometers to be used for hyperspectral imaging, especially in the infrared spectral region. Unlike both imaging and non-imaging traditional Fourier-transform spectrometers, the E-O IFTS does not contain any moving parts. Elimination of the moving parts and the associated actuator mechanisms and supporting structures would increase reliability while enabling reductions in size and mass, relative to traditional Fourier-transform spectrometers that offer equivalent capabilities. Elimination of moving parts would also eliminate the vibrations caused by the motions of those parts. Figure 1 schematically depicts a traditional Fourier-transform spectrometer, wherein a critical time delay is varied by translating one the mirrors of a Michelson interferometer. The time-dependent optical output is a periodic representation of the input spectrum. Data characterizing the input spectrum are generated through fast-Fourier-transform (FFT) post-processing of the output in conjunction with the varying time delay.

Chao, Tien-Hsin↗