Engineering PapersSearch

SEARCH · Engineering Papers

Results for “optical facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Portable Optical Particle Spectrometer aboard an Airborne Platform (POPS_AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility portable optical particle spectrometer (POPS) is a lightweight particle spectrometer designed for aerosol particle size distribution measurement. Several POPS of different versions have been procured to serve as routine instruments for the ARM Aerial Facility (AAF) unmanned aerial systems (UAS) and tethered balloon system (TBS) deployment since 2018. POPS measures the aerosol particle size distribution approximately between 0.13 and 3 μm.

54 ENVIRONMENTAL SCIENCES

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.

Experimental instrumentation system for the Phased Array Mirror Extendible Large Aperture (PAMELA) test program

Adaptive optics are used in telescopes for both viewing objects with minimum distortion and for transmitting laser beams with minimum beam divergence and dance. In order to test concepts on a smaller scale, NASA MSFC is in the process of setting up an adaptive optics test facility with precision (fraction of wavelengths) measurement equipment. The initial system under test is the adaptive optical telescope called PAMELA (Phased Array Mirror Extendible Large Aperture). Goals of this test are: assessment of test hardware specifications for PAMELA application and the determination of the sensitivities of instruments for measuring PAMELA (and other adaptive optical telescopes) imperfections; evaluation of the PAMELA system integration effort and test progress and recommended actions to enhance these activities; and development of concepts and prototypes of experimental apparatuses for PAMELA.

Boykin, William H., Jr.

Optical testing cryogenic thermal vacuum facility

The construction of a turnkey cryogenic vacuum test facility was recently completed. The facility will be used to measure and record the surface profile of large diameter and 540 kg optics under simulated space conditions. The vacuum test chamber is a vertical stainless steel cylinder with a 3.5 diameter and a 7 m tangent length. The chamber was designed to maximize optical testing quality by minimizing the vibrations between the laser interferometer and the test specimen. This was accomplished by designing the chamber for a high natural frequency and vibration isolating the chamber. An optical test specimen is mounted on a movable presentation stage. During thermal vacuum testing, the specimen may be positioned to + or - 0.00025 cm accuracy with a fine adjustment mechanism. The chamber is evacuated by a close coupled Roots-type blower and rotary vane pump package and two cryopumps. The chamber is equipped with an optically dense gaseous nitrogen cooled thermal shroud. The thermal shroud is used to cool or warm the optical test specimen at a controlled rate. A control system is provided to automatically evacuate the chamber and cooldown the test specimen to the selected control temperature.

Dohogne, Patrick W.

Progress on ten-meter optical receiver telescope

A ten-meter hexagonally segmented Cassegrain optical telescope is being considered at the Jet Propulsion Laboratory for use as a research and development facility for optical communications technology. The goal of the study is to demonstrate technology which can eventually be used to develop a network of such telescopes to continuously track and communicate with the spacecraft. Hence, the technology has to be economical enough to allow replication for a ground or space based network. As we need to collect signal photons only, the telescope cost can be substantially reduced by accepting lower image quality. An important design consideration for the telescope is its ability to look very close to the sun. The telescope for optical communications must function during the daytime. Indeed, for some planetary missions it may be necessary that the system be capable of looking within a few degrees of the sun. To enable this, a unique sunshade consisting of hexagonal tubes in precise alignment with the mirror segments has been proposed which will also serve as the support for the secondary. Recent progress on the design and analysis of such an optical reception station is discussed here.

Shaik, Kamran

Optical figure testing of prototype mirrors for JPL's Precision Segmented Reflector (PSR) program

JPL's PSR program is developing enabling technologies for large space telescopes employing segmented optics, and in particular, lightweight, thermally stable mirrors for telescopes operating at sub-mm wavelengths. JPL's vacuum cryointerferometric optical test facility includes a computer-controlled phase shifting interferometer operating at 10.59 microns and laser metrology for measurement of piston and absolute radius of curvature. The optical metrology has been integrated with a large vacuum chamber including a liquid nitrogen shroud capable of radiatively cooling 1.5 meter aperture mirrors down to 150 K. The facility is now being used to characterize prototype mirrors in both their room-temperature 'as-replicated' condition, and under orbital temperature conditions. The performance and limitations of the optical metrology hardware and software components are noted. Representative test results on prototype one meter-class composite mirrors being developed for PSR and related ground-based programs are also presented.

Hochberg, Eric B.

Degradation of optical components in space

This report concerns two types of optical components: multilayer filters and mirrors, and self-scanned imaging arrays using charge coupled device (CCD) readouts. For the filters and mirrors, contamination produces a strong reduction in transmittance in the ultraviolet spectral region, but has little or no effect in the visible and infrared spectral regions. Soft substrates containing halides are unsatisfactory as windows or substrates. Materials choice for dielectric layers should also reflect such considerations. Best performance is also found for the harder materials. Compaction of the layers and interlayer diffusion causes a blue shift in center wavelength and loss of throughput. For sensors using CCD's, shifts in gate voltage and reductions in transfer efficiency occur. Such effects in CCD's are in accord with expectations of the effects of the radiation dose on the device. Except for optical fiber, degradation of CCD's represents the only ionizing-radiation induced effect on the Long Duration Exposure Facility (LDEF) optical systems components that has been observed.

Blue, M. D.

Study of a stereo electro-optical tracker system for the measurement of model deformations at the national transonic facility

An electro-optical method to measure the aeroelastic deformations of wind tunnel models is examined. The multitarget tracking performance of one of the two electronic cameras comprising the stereo pair is modeled and measured. The properties of the targets at the model, the camera optics, target illumination, number of targets, acquisition time, target velocities, and tracker performance are considered. The electronic camera system is shown to be capable of locating, measuring, and following the positions of 5 to 50 targets attached to the model at measuring rates up to 5000 targets per second.

Hertel, R. J.

Optical Fiber H2 Sensor Operating in Harsh Environments of Subsurface H2 Storage Reservoirs

Monitoring hydrogen concentration in the subsurface storage reservoirs is vital to ensure the integrity and safety of the storage facilities. An optical fiber hydrogen sensor consisting of a palladium-based sensing layer and a protective polymer layer was developed and evaluated in simulated subsurface hydrogen storage conditions. The developed optical fiber hydrogen sensor has demonstrated successful sensing performance at ~80 °C, ~1,000 psi, and ~100% RH. In addition, the sensor was exposed to real subsurface microbial samples in the harsh environments to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity in the presence of biological samples.

filter layer

Preliminary design study for an atomospheric science facility

The activities and results of the Atmospheric Science Facility preliminary design study are reported. The objectives of the study were to define the scientific goals, to determine the range of experiment types, and to develop the preliminary instrument design requirements for a reusable, general purpose, optical research facility for investigating the earth's atmosphere from a space shuttle orbital vehicle.

Hutchison, R.

Cryogenic optical tests of a lightweight HIP beryllium mirror

Five interferometric tests were conducted at cryogenic temperatures on a lightweight, 50 cm diameter, hot isostatic pressed (HIP) beryllium mirror in the Ames Research Center (ARC) Cryogenic Optics Test Facility. The purpose of the tests was to determine the stability of the mirror's figure when cooled to cryogenic temperatures. Test temperatures ranged from room ambient to 8 K. One cycle to 8 K and five cycles to 80 K were performed. Optical and thermal test methods are described. Data is presented to show the amount of cryogenic distortion and hysteresis present in the mirror when measured with an earlier, Shack interferometer, and with a newly-acquired, phase-measuring interferometer.

Melugin, Ramsey K.

Aerodynamics facilities

Environmental simulation facilities, biplanar optical systems for nonplanar free flight tests, hypersonic boom and air radiation measurements, and X-15 and wedge wake studies

OPTICAL EQUIPMENT

Modular space station facilities.

The modular space station will operate as a general purpose laboratory (GPL). In addition, the space station will be able to support many attached or free-flying research and application modules that would be dedicated to specific projects like astronomy or earth observations. The GPL primary functions have been organized into functional laboratories including an electrical/electronics laboratory, a mechanical sciences laboratory, an experiment and test isolation laboratory, a hard data process facility, a data evaluation facility, an optical sciences laboratory, a biomedical and biosciences laboratory, and an experiment/secondary command and control center.

Parker, P. J.

Optical alignment measurements at Goddard Space Flight Center

The significant changes that have been made in the Optical Alignment Facility at the Goddard Space Flight Center since it was last described (Appler and Howell, 1968) are discussed. The changes are reflected in both the hardware and the software involved in making alignment measurements. The data analysis procedures can now be done on a desktop computer with turn-around times of approximately 4 h. Arbitrary coordinate transformations and corrections for facility errors are also feasible while retaining absolute accuracies of less than 6 sec of arc.

Eichhorn, W. L.

Optical electronics for meteor observations

Spectral observations of meteors have been carried out for several years using an optical electronics facility. Interest has centered on faint meteors and their trails in the period of intensive meteor showers. Over 800 meteors were registered during the observation period, with spectrograms obtained for 170 of these. A total of 86 meteors were photographed from two sites and for 25 of these spectrograms of the meteors as well as their trails were obtained. All meteors have undergone routine processing in order to determine atmospheric characteristics. Results are discussed.

Shafiev, R. I.

Requirements for temperature and species concentration measurements in microgravity combustion experiments

The requirements for a nonintrusive optical diagnostic facility for Space Station are assessed by examining the needs of current and future combustion experiments to be flown aboard the Space Station. Requirements for test section geometry and size, spatial and temporal resolution, species type and concentration range, and temperature range are reviewed. The feasibility of the development of this system is also addressed. The suitability of this facility to non-combustion experiments in gases and liquids is also considered.

Ronney, Paul D.

Ames Research Center cryogenic mirror testing program - A comparison of the cryogenic performance of metal and glass mirrors with different types of mounts

A summary of the cryogenic testing of glass and metal mirrors performed at NASA Ames Research Center (ARC) and two other places is presented. Recent improvements to the ARC Cryogenic Optics Test Facility are described. The purposes of the tests were to determine: (1) how glass mirrors would perform at cryogenic temperatures compared with metal mirrors and (2) how various mirror mounts would affect the cryogenic performance of mirrors. Details of a cryogenic test of a 50 cm 'double arch', fused-silica mirror with a three-point mount and with a radially-compliant, flexured mount are given. Within the accuracy of the measurements, it was determined that the flexured mount did not induce appreciable distortion in the double arch mirror. Results of the cryogenic tests of a number of glass mirrors and two beryllium mirrors are included. The cryogenic distortion of the glass mirrors was found to be less than that for the beryllium mirrors. Within the accuracy of the measurements, no hysteresis was found in the glass mirrors. It was possible to measure hysteresis in one of the beryllium mirrors.

Miller, Jacob H.

Damage areas due to impact craters on LDEF aluminum panels

Because of its exposure time and total exposed surface area, the LDEF provides a unique opportunity to analyze the effects of the natural and man-made particle populations in low earth orbit (LEO). This study concentrated on collecting and analyzing measurements of impact craters from seven painted aluminum surfaces at different locations on the satellite. These data are being used to: (1) update the current theoretical micrometeoroid and debris models for LEO; (2) characterize the effects of the LEO micrometeoroid and debris environment of satellite components and designs; (3) help assess the probability of collision between spacecraft in LEO and already resident debris and the survivability of those spacecraft that must travel through, or reside in, LEO; and (4) help define and evaluate future debris mitigation and disposal methods. Measurements were collected from one aluminum experiment tray cover (Bay C-12), two aluminum grapple plates (Bays C-01, C-10), and four aluminum experiment sun-shields (Bay E-09), all of which were coated with thermal paint. These measurements were taken at the Facility for Optical Interpretation of Large Surfaces (FOILS) Lab at JSC. Virtually all features greater than 0.2 mm in diameter possessed a spall zone in which all of the paint was removed from the aluminum surface, and which varied in size from 2-5 crater diameters. The actual craters vary from central pits without raised rims to morphologies more typical of craters formed in aluminum under hypervelocity impact conditions for larger features. Most craters exhibit a shock zone that varies in size from approximately 1-20 crater diameters. In general, only the outermost layer of paint was affected by this impact-related phenomenon, with several impacts possessing ridge-like structures encircling the area in which this outer-most paint layer was removed. Overall, there were no noticeable penetrations or bulges on the underside of the trays. One tray from the E-09 bay exhibited a spallation zone on the backside, approximately equal in size to that on the front side. Results from this study demonstrate that the impact damaged areas extend far beyond the actual craters in coated or painted surfaces. While the cratering damaged much greater than 1 percent of the total surface area, the total impact damage area exceeded 3 percent.

Coombs, Cassandra R.