Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preventing Voltage Divergence in Series-Stacked Bidirectional Battery Energy Storage DC-DC Converter under Asymmetrical Operating Conditions

DC stacked topologies have gained popularity for interfacing individual photovoltaic panels to a high-voltage DC bus. A similar approach can be used to interface individual battery packs to the same DC bus, which allows active balancing of battery substrings and the use of lower voltage switches. Any imbalance in battery current, however, can cause the converter output voltages to diverge. This paper describes the source of voltage divergence and demonstrates a solution that allows seamless stacking of multiple battery packs to be interfaced to a high voltage DC bus. To prevent the voltage divergence phenomenon and allow asymmetrical battery charging for efficient battery state of charge management, the PI-based decentralized voltage control enabling both capacitor voltage sharing and asymmetrical capacitor voltage control is proposed. The effectiveness of the decentralized voltage control strategy is demonstrated through controller hardware-in-the-loop test results.

Kim, Namwon↗

Radial Compressor Design and Off-Design for Trans-critical CO2 Operating Conditions

Presentation for the The 7th International Supercritical CO2 Power Cycles Symposium, February 21 – 24, 2022, San Antonio, Texas. A multi-staged intercooled centrifugal compressor design is performed for an indirect-fired sCO2 cycle and the design point data are used to generate the performance maps using a 2D mean-line analysis code. Fluid and turbomachinery similarity laws are applied to find an appropriate surrogate ideal gas fluid to be used in the design and performance map generation codes. The performance maps are then scaled back for the sCO2 fluid case using the affinity laws.

Uysal, Selcuk Can↗

Operating Conditions of a Main Bearing Contact in a Commercial Wind Turbine

This presentation described acoustic emissions and temperature characteristics of a commercial main bearing in a wind turbine drivetrain. These characteristics were measured on the outer ring of the bearing by SKF DVST nodes, which are mounted on both upwind and downwind rows of the main bearing at four equally spaced circumferential locations. The measurement started in early 2018 and ends in 2020 and five-month data in 2018 winter was analyzed in this study.

acoustic emission↗

Exploration of multifidelity UQ sampling strategies for computer network applications.

Network modeling is a powerful tool to enable rapid analysis of complex systems that can be challenging to study directly using physical testing. Here, two approaches are considered: emulation and simulation. The former runs real software on virtualized hardware, while the latter mimics the behavior of network components and their interactions in software. Although emulation provides an accurate representation of physical networks, this approach alone cannot guarantee the characterization of the system under realistic operative conditions. Operative conditions for physical networks are often characterized by intrinsic variability (payload size, packet latency, etc.) or a lack of precise knowledge regarding the network configuration (bandwidth, delays, etc.); therefore uncertainty quantification (UQ) strategies should be also employed. UQ strategies require multiple evaluations of the system with a number of evaluation instances that roughly increases with the problem dimensionality, i.e., the number of uncertain parameters. It follows that a typical UQ workflow for network modeling based on emulation can easily become unattainable due to its prohibitive computational cost. In this paper, a multifidelity sampling approach is discussed and applied to network modeling problems. The main idea is to optimally fuse information coming from simulations, which are a low-fidelity version of the emulation problem of interest, in order to decrease the estimator variance. By reducing the estimator variance in a sampling approach it is usually possible to obtain more reliable statistics and therefore a more reliable system characterization. Several network problems of increasing difficulty are presented. For each of them, the performance of the multifidelity estimator is compared with respect to the single fidelity counterpart, namely, Monte Carlo sampling. For all the test problems studied in this work, the multifidelity estimator demonstrated an increased efficiency with respect to MC.

97 MATHEMATICS AND COMPUTING↗

Selection and Use Considerations for Laser Power Photovoltaic Receivers

III-V PV receivers provide high performance over wide range of application conditions. Operating conditions including irradiance and cell temperature must be accounted for. Very high efficiencies demonstrated for small GaAs devices. Potential for significant future advances in performance, especially for other wavelengths and for cost.

GaAs↗

Parametric Testing and Evaluation of a Novel Biphasic Absorption Process for Post-Combustion Carbon Capture

A novel biphasic CO2 absorption process (BiCAP) is being developed at the University of Illinois. BiCAP is enabled by using a new class of biphasic solvents developed based on multi-property criteria for postcombustion carbon capture. The process was previously demonstrated at the lab-scale, including in 10 kWe absorption and desorption column systems. In the current study, the process has been scaled up by building and testing a 40 kWe integrated capture skid at a power plant. Parametric tests for two biphasic solvents were conducted with the synthetic flue gas made of bottle CO2 gas and air to validate the performance and operational flexibility of the unit with respect to varying process or operating conditions. Operation of the phase separator, which is unique equipment to BiCAP, was verified to be stable and efficient. Two liquid phases could be separated via static settlement based on a density difference and >90% of the CO2 absorbed was concentrated in the separated CO2-rich phase. Results of parametric tests showed that the minimum heat duty appeared at the optimal stripping pressure. A higher stripping temperature was more favourable to improve overall energy performance. Introducing a secondary cold solvent feed stream to the top of the stripper via bypassing the cross heat exchanger helped reduce the heat loss carried with water vapour. Test results also revealed that the heat duty requirement was comparable when the CO2 concentration in flue gas decreased from ~11 to 4 vol.% as the phase separation decoupled the absorption and desorption steps in BiCAP. Under typical steady-state conditions, both biphasic solvents lowered the process heat duty by >40% compared with the reference 30 wt.% monoethanolamine solvent.

Absorption↗

A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

Deep Learning Based Frequency Stability Assessment in Power Grid with High Renewables

Frequency stability assessment is one critical aspect of power system security assessment. Traditional N-1 screening method is based on the simulations of a few typical daily and seasonal operation scenarios. However, the increasing integration of inverter-based renewables and the retirement of conventional synchronous generators result in decreasing system inertia and growing complexity of system operating conditions. Selecting a few typical operation scenarios cannot cover all operating conditions, and the time-domain simulation of all operation conditions requires tremendous time. This paper proposes a more efficient frequency stability assessment method based on deep learning. The affinity propagation clustering algorithm is used to divide the dataset into different clusters, so the selected dataset for training can cover the diversified operating conditions as much as possible. Also, feature normalization is applied to both the training dataset and testing dataset in order to remove any unnecessary bias. Especially, trained model based on full dataset normalization has bounded error in the prediction. The case study on the reduced 240-bus WECC system demonstrates that the proposed method can predict accurate frequency nadir with limited training dataset. The deep learning model using the revised feature normalization can predict more accurate frequency nadir than that using the traditional feature normalization and has very small maximum prediction error.

affinity propagation↗

Voltage-Based Strategies for Preventing Battery Degradation under Diverse Fast-Charging Conditions

Maintaining safe operating conditions is a key challenge for high-performance lithium-ion battery applications. The lithium-plating reaction remains a risk during charging, but limited studies consider the highly variable charging conditions possible in commercial cells. Here we combine pseudo-2D electrochemical modeling with data visualization methods to reveal important relationships between the measurable cell voltage and difficult-to-predict Li-plating onset criteria. An extensively validated model is used to compute Li plating for thousands of multistep charging conditions spanning diverse rates, temperatures, states-of-charge, and cell aging. Here we observe an empirical cell operating voltage limit below which plating does not occur across all conditions, and this limit varies with the battery state-of-charge and aging. A model sensitivity analysis also indicates that, when comparing two charging voltage profiles, the capacity difference at 4.0 V correlates well with the difference in the plating onset capacity. These results encourage simple strategies for Li-plating prevention that are complementary to existing battery controls.

25 ENERGY STORAGE↗

Multi-mode advanced combustion engine with supervisory control

An engine system uses data associated with at least one operating condition of an engine to set the engine system to an AI mode when the engine is in an SI mode 1) within first operating condition limits, and 2) when a rate of change of a first operating condition is within rate of change limits, maintain the engine system in the SI mode when the engine is outside of first operating condition limits or when the rate of change of the first operating condition is not within rate of change limits, set the engine system to the SI mode when the engine is in the AI mode outside second operating condition limits, and maintain the engine system in the AI mode when the engine is within second operating condition limits, wherein the second operating condition limits are different from the first operating condition limits.

42 ENGINEERING↗

Adjustable primary and supplemental power units

A propulsion system for an aircraft includes a core flow path in communication with a compressor section, combustor section and a turbine section. A first bottoming cycle system includes a bottoming working fluid flow in thermal communication with a high energy exhaust gas flow that is generated by the core engine. The first bottoming cycle is configured to recover power from the high energy exhaust gas flow in a first engine operating condition and in a second engine operating condition. A second bottoming cycle system is configured to recover power from the high energy exhaust gas flow in the first engine operating condition and not to recover power in a second engine operating condition.

MacDonald, Malcolm P.↗

Method and apparatus for providing wear leveling

Exemplary embodiments provide wear spreading among die regions (i.e., one or more circuits) in an integrated circuit or among dies by using operating condition data in addition to or instead of environmental data such as temperature data, from each of a plurality of die regions. Control logic produces a cumulative amount of time each of the plurality of die regions has spent at an operating condition based on operating condition data wherein the operating condition data is based on at least one of the following operating characteristics: frequency of operation of the plurality of die regions, an operating voltage of the plurality of die regions, an activity level of the plurality of die regions, a timing margin of the plurality of die regions, and a number of detected faults of the plurality of die regions. The method and apparatus spreads wear among the plurality of same type of die regions by controlling task execution among the plurality of die regions using the die wear-out data.

Raasch, Steven↗

Deep Learning-Based Adaptive Remedial Action Scheme with Security Margin for Renewable-Dominated Power Grids

The Remedial Action Scheme (RAS) is designed to take corrective actions after detecting predetermined conditions to maintain system transient stability in large interconnected power grids. However, since RAS is usually designed based on a few selected typical operating conditions, it is not optimal in operating conditions that are not considered in the offline design, especially under frequently and dramatically varying operating conditions due to the increasing integration of intermittent renewables. The deep learning-based RAS is proposed to enhance the adaptivity of RAS to varying operating conditions. During the training, a customized loss function is developed to penalize the negative loss and suggest corrective actions with a security margin to avoid triggering under-frequency and over-frequency relays. Simulation results of the reduced United States Western Interconnection system model demonstrate that the proposed deep learning–based RAS can provide optimal corrective actions for unseen operating conditions while maintaining a sufficient security margin.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai↗