At least 73 records · Page 4

INL CRMO XRF Report 2025-02: Provenance Determinations for 1,124 Projectile Points from Lands and Collections Managed by the U.S. Department of Energy-Idaho Operations Office (DOE-ID)

This report presents provenance determinations for 1,124 obsidian and fine-grained volcanic (FGV) projectile points from lands and collections managed by the U.S. Department of Energy-Idaho Operations Office (DOE-ID). These determinations were made using energy-dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

58 GEOSCIENCES↗

Enabling Solar Cybersecurity Solutions Through State Energy Office and Public Utility Commission Engagement with Private Sector Partners (Final Technical Report)

Between 2020 and 2025, the National Association of State Energy Officials (NASEO), together with the National Association of Regulatory Utility Commissioners (NARUC) established and managed the Enabling Solar Cybersecurity Solutions Through State Energy Office and Public Utility Commission Engagement with Private Sector Partners project, later informally retitled and recognized as the Cybersecurity Advisory Team for State Solar (CATSS). This effort convened State Energy Offices, Public Utility Commissions, and critical private sector and federal partners to inform the development of solar cybersecurity education and action-oriented resources for states. This is the final report.

14 SOLAR ENERGY↗

PNNL Sequim Campus Radionuclide Air Emissions Report for Calendar Year 2025 : Department of Energy – Office of Science Pacific Northwest National Laboratory

The U.S. Department of Energy Office of Science’s Pacific Northwest Site Office has oversight and stewardship duties associated with the Pacific Northwest National Laboratory Sequim Campus. Facility operations include radiological operations with the potential-to-emit low levels of radioactive materials. This report is prepared to document compliance with the 40 CFR Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,” and Washington Administrative Code Chapter 246-247, Radiation Protection–Air Emissions. The PNNL Sequim Campus is in compliance with the federal and state 10 mrem/yr standard for 2025 operations.

40 CFR 61 Subpart H↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Demand Flexibility in Large Office Buildings

Data is associated with Report "Efficiency and Demand Flexibility in Large Office Buildings" by Joyce McLaren, Thomas Bowen, and Chioke Harris ( https://doi.org/10.2172/1989231 ). Results are created from repos GEB_ECM_Impact_Estimator ( https://github.nlr.gov/tbowen/GEB_ECM_Impact_Estimator ). Results outline the changes in building load in large office buildings based on measures from NREL's Scout, and the impacts those changes in load have on grid-induced emissions, grid operating costs, and customer bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Brochure for the DOE Office of Science Workshop on Envisioning Frontiers in AI and Computing for Biological Research

In February of 2025 a joint ASCR/BER workshop was held to identify key transformational research directions for understanding biology using artificial intelligence (AI), digital twins and high-performance (HPC) computational methods to facilitate scientific discovery and innovation in support of the Department of Energy mission. AI technologies offer exciting new groundbreaking methods to analyze large volumes of complex biological data, thereby greatly accelerating the ability to understand, predict, and design biological processes for beneficial purposes. In the laboratory, the bridging of AI-enabled automated experimental technologies, HPC and digital twins will provide potent tools for researchers to explore the fundamental nature of biology and harness its inherent metabolic potential for a variety of beneficial purposes. The focus of this workshop was on how high-performance computational methods can impact this objective by exploring digital twins, foundational models, and data-driven approaches with applications to advance automated laboratory experiments, modeling of complex living systems and engineering new functions into plants and microbial systems relevant to DOE mission. Workshop attendees with expertise in plant science, microbiology, mathematics, computer science, and AI assessed the current state of the science, trends, and AI challenges at the interface of plant and microbial systems biology and computational science to identify opportunities for high-impact research. This collaborative effort capitalized on ASCR's advancements in applied mathematics, computer science, and Exascale systems, and BER's expertise in basic genomics-enabled research on DOE relevant plant and microbial systems. The workshop culminated in four key priority research directions to guide future research and development within DOE Office of Science programs.

59 BASIC BIOLOGICAL SCIENCES↗

Case Study: The Tower Companies' Commercial Office Solar PV

This case study describes how the Tower Companies selected and successfully executed onsite solar photovoltaic installations at its commercial office properties and highlights the resulting increase in asset value.

solar, solar PV, photovoltaic, onsite solar, comme↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Solar Energy Technologies Office Workforce Request for Information and Convenings (Summary)

On May 4, 2021, the U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO) published a Request for Information (RFI) on programs that support the development of a diverse and skilled clean energy workforce. The purpose of the RFI was to solicit feedback from industry, academia, government agencies, worker organizations (including unions), and other stakeholders on issues related to the employment needs of the solar industry, and the perceived value of different workforce development programs, training strategies, and tools. To supplement the RFI, SETO hosted four virtual convenings that brought together the utility-scale solar industry, the distributed generation solar industry, and labor and other workforce training organizations to hear direct feedback on the questions in the RFI. In addition, SETO held listening sessions with about a dozen other organizations and staff who could not participate in the virtual convenings. Altogether, SETO received 45 responses from the RFI and heard directly from 80-100 other stakeholders via the convenings and listening sessions. This document summarizes the stakeholder feedback that SETO received as a result of this process. While both the RFI and convening series were focused on solar deployment and solar industry members, much of this information is relevant across clean energy technologies and programs. It is important to recognize that DOE is intentionally reviewing our workforce development programming and support to focus on clean energy careers more holistically.

14 SOLAR ENERGY↗

Managing Army Plug Load Equipment Energy Use: Office Equipment

Office equipment covers a large and diverse group of plug load devices. Policies focused on equipment purchase, power management, and usage limitations can save the Army more than 10 million kWh and $620K per year within just four building categories. This represents a top opportunity for energy- and cost-savings identified by a recent Army plug load study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Circadian Lighting Design Strategies on Lighting and Cooling Energy of an Office Space

A DOE-funded study of the potential electrical and thermal energy impacts of using daylight and electric light to meet existing recommendations for human health and well-being, conducted by Pacific Northwest National Laboratory (PNNL) in collaboration with researchers from Lawrence Berkeley National Laboratory, the University of Washington, and the University of Oregon. New software tools for modeling the spectral characteristics of light, like Adaptive Lighting for Alertness (ALFA), were leveraged to conduct annual daylighting, electric lighting, heating, and cooling simulations for office applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Evaluation Framework for State Energy Offices' Energy Efficiency and Clean Energy Workforce Programs

Historic levels of funding for energy efficiency and clean energy projects from the Bipartisan Infrastructure Law and Inflation Reduction Act will be flowing through State Energy Offices (SEOs) in the coming years, including funds specifically for supporting workforce development efforts. This report offers a workforce evaluation framework that they can use to track and measure the progress, performance, and effectiveness of energy efficiency and clean energy workforce programs that they fund and/or implement. This evaluation step is essential to ensuring that SEOs' workforce efforts remain relevant to the evolving needs of the energy efficiency and clean energy sector and advance a workforce that is inclusive and diverse thus maximizing the success of their programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing modifications to the Abdul-Razzak and Ghan aerosol activation parameterization (version ARG2000) to improve simulated aerosol–cloud radiative effects in the UK Met Office Unified Model (UM version 13.0)

The representation of aerosol activation is a key source of uncertainty in global composition-climate model simulations of aerosol–cloud interactions. The Abdul-Razzak and Ghan (ARG) activation parameterization is used in several global and regional models that employ modal aerosol microphysics schemes. In this study, we investigate the ability of the ARG parameterization to reproduce simulations with a cloud parcel model and find its performance is sensitive to the geometric standard deviations (widths) of the lognormal aerosol modes. We recommend adjustments to three constant parameters in the ARG equations, which improve the performance of the parameterization for small mode widths and its ability to simulate activation in polluted conditions. For the accumulation mode width of 1.4 used in the Met Office Unified Model (UM), the modifications decrease the mean bias in the activated fraction of aerosols compared to a cloud parcel model from −6.6 % to +1.2 %. We implemented the improvements in the UM and compared simulated global cloud droplet concentrations with satellite observations. The simulated cloud radiative effect changes by −1.43 W m −2 (6 %) and aerosol indirect radiative forcing over the industrial period changes by −0.10 W m −2 (10 %).

Ghosh, Pratapaditya [Carnegie Mellon University, P↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗