Engineering PapersSearch

SEARCH · Engineering Papers

Results for “nylons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Material extrusion with integrated compression molding of NdFeB/SmFeN nylon bonded magnets using small- and large-scale pellet-based 3D-printers

High-density bonded rare-earth magnets are manufactured using pellet-fed additive manufacturing (AM)/material extrusion and an integrated additive manufacturing-compression molding (AM-CM) process. Neodymium iron boron – samarium iron nitride in polyamide 12 (NdFeB-SmFeN/PA12) of 93 % weight fraction (65 % volume fraction) are used for the study. The mechanical properties (tensile strength and modulus), magnetic properties (maximum energy density, coercivity, remanence) are reported. Manufacturing parameters such as layer height, barrel temperatures, screw speed and gantry feed rate are optimized to obtain the highest possible density of the magnets using a small-scale desktop material extrusion printer. Large scale integrated additive manufacturing-compression molding (AM-CM) is then utilized to increase the density of the magnets by reducing porosity defects common in the material extrusion process. The density of as-printed magnets was 5.2 g/cm 3 with a BH max value of 124.14 kJ/m 3 , tensile strength of 20 MPa and a modulus of 2 GPa. AM-CM increased the density of the compound by 5.5 % (5.49 g/cm 3 ). The reduction in porosity was confirmed using X-ray tomography (XCT). Improvement in mechanical strength of the material was also observed, with an increase in tensile strength of 25 % (25.09 MPa) and increase in tensile modulus of 275 % (5.49 GPa). Scanning electron microscopy showed increased particle-matrix adhesion with the integrated AM-CM process.

36 MATERIALS SCIENCE

Chemical evaluation of non-woven nylon separators used in Ni/Cd cells

The goals of the chemical analysis was to identify Gates 2505 degradation mechanism, to determine if Eagle-Pitcher 2505 supply suitable for flight, and to assess the 2538 as a candidate replacement, based on chemical findings. Chemical testing strongly indicates that the Gates 2505 stored in Florida had undergone partial chemical deterioration, believed caused by exposure to high humidities and temperature. A suspected role of zinc chloride as a separator concern during storage was not verified in this study (the effect of ZnCl2 on cell/electrode performance was not addressed). No substantial chemical issues or concerns with using EP 2505 as Ni/Cd battery separator for Mars Observer and TOPEX could be found. No chemical issues or concerns with using 2538 as Ni/Cd battery separator were found, in fact, chemical evidence suggest that 2538 may be a better material, as compared to 2505.

Cuddihy, Edward F.

Mixed polyamide and polyester upcycling via chemical autoxidation and engineered Pseudomonas putida

Polyamides, such as nylons, are often used in multi-component materials, like textiles and packaging, and are accompanied with unique recycling challenges. Recently, autoxidation and bioconversion has emerged as a tandem approach for the conversion of mixed plastics waste to single products, however the fate of polyamides in these processes is unknown. Here, we optimized the autoxidation of nylon-6 and nylon-6,6 depolymerization, achieving >92 mol% nitrogen recovery from both substrates, predominantly as acetamide, and 20–27 mol% carbon recovery (not including acetamide). Experiments with 13 C-labeled acetic acid demonstrated that the carbon in acetamide was solvent derived. Autoxidation of mixed nylon-6 and poly(ethylene terephthalate) (PET) post-consumer fibers resulted in similar carbon and nitrogen recoveries from nylon, while PET was depolymerized to terephthalic acid (TPA) at >65 C-mol% recovery. Next, we engineered Pseudomonas putida KT2440 to utilize acetamide as the sole carbon and nitrogen source for growth through the constitutive expression of genes encoding amidase enzymes, including a native amidase (PP_0613) shown to be active on C 2 –C 4 amides. Heterologous chromosomal expression of amiE, encoding the amidase from P. aeruginosa, was found to be superior to PP_0613 constitutive expression in genome integrated strains. Prior engineering to enable TPA conversion to β-ketoadipate pathway intermediate protocatechuate was leveraged and combined with deletion of pcaD to produce muconolactone as a product. Finally, a stacked strain engineered for conversion of acetamide, TPA, and DCAs was evaluated on the reaction product from autoxidation of mixed post-consumer nylon and PET fibers without any supplemental nitrogen, achieving quantitative yields in the presence of supplemental carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Combustion of velcro in low gravity

An experimental program was conducted to investigate the low gravity burning characteristics on nylon and Nomex Velcro fastening tapes in an atmosphere of 30-percent oxygen, 70-percent nitrogen at a 70-kPa pressure. The tests were conducted using the NASA Lewis Research Center Zero Gravity Facility. The test results, as documented by high-speed cameras, indicate that both nylon and Nomex burn in low gravity for the full 5.18 sec test time but that Nomex burns less vigorously than nylon. Nylon melts as it burns, whereas Nomex forms a solid char. Nylon also sputters burning droplets as it burns. Thus, from these limited tests, it appears that Nomex Velcro is less hazardous than nylon Velcro for spacecraft applications. The results also show that residual gas velocities, and by analogy spacecraft air circulation, can enhance the low-gravity combustion.

Olson, Sandra L.

Feasibility of Metal Oxide Glasses and Polymer Membranes as Sorbents for Gaseous Oxidized Mercury

Mass spectrometry methods are currently under development by the atmospheric mercury (Hg) research community to elucidate the identity of atmospheric oxidized mercury (Hg II ) compounds. Due to high instrument detection limits, materials that can quantitatively preconcentrate atmospheric Hg II without facilitating compound-altering chemical reactions are needed to support these methods. Cation exchange membranes (CEM) and nylon membranes are currently used to preconcentrate ambient Hg II for concentration measurements and Hg II compound estimation, respectively. However, CEM and nylon membranes are poor candidates for observations by mass spectrometry methods due to release of interfering compounds upon heating; glasses do not have this problem. Here, three metal oxide glasses were explored as potential alternatives for Hg II preconcentration for future use with mass spectrometry methods: calcium phosphate (CaP), iron phosphate (FeP), and calcium aluminate (CaAl). The glasses demonstrated quantitative selective capture of HgBr 2 without capture of Hg 0 . Under ambient conditions, the CaP, FeP, and CaAl sorbed 36.4 ± 12.6% of the total HgII as the CEM. However, when Hg concentrations were normalized to surface area, CaP, FeP, and CaAl sorbed more HgBr 2 in the laboratory and ambient HgII compared to CEM. The CEM and CaP retained similar concentrations of HgBr 2 when preloaded samples were deployed in the field. Additionally, a permeation tube-based calibrator was used to load sorbents with HgBr 2 for investigation of HgII retention on CEM and thermal desorption profile changes on nylon membranes during active sampling. Nylon membranes were purchased from three vendors and used to compare HgBr 2 retention; a different HgBr 2 thermal desorption profile was achieved for each vendor’s nylon membrane.

Amides

Evaluation of Brushing as a Lunar Dust Mitigation Strategy for Thermal Control Surfaces

Evaluation of brushing to remove lunar simulant dust from thermal control surfaces is described. First, strip brushes made with nylon, PTFE, or Thunderon bristles were used to remove JSC-1AF dust from AZ93 thermal control paint or aluminized FEP (AlFEP) thermal control surface under ambient laboratory conditions. Nylon and PTFE bristles removed a promising amount of dust from AZ93, and nylon and Thunderon bristles from AlFEP. But when these were tested under simulated lunar conditions in the lunar dust adhesion bell jar (LDAB), they were not effective. In a third effort, seven brushes made up of three different materials, two different geometries, and different bristle lengths and thicknesses were tested under laboratory conditions against AZ93 and AlFEP. Two of these brushes, the Zephyr fiberglass fingerprint brush and the Escoda nylon fan brush, removed over 90 percent of the dust, and so were tested in the fourth effort in the LDAB. They also performed well under these conditions recovering 80 percent or more of the original thermal performance (solar absorptance/thermal emittance) of both AZ93 and AgFEP after 20 strokes, and 90 or more percent after 200 strokes.

Gaier, James R.

Evaluation of Brushing as a Lunar Dust Mitigation Strategy for Thermal Control Surfaces

Evaluation of brushing to remove lunar simulant dust from thermal control surfaces is described. First, strip brushes made with nylon, PTFE, or Thunderon (Nihon Sanmo Dyeing Company Ltd.) bristles were used to remove JSC-1AF dust from AZ93 thermal control paint or aluminized FEP (AlFEP) thermal control surface under ambient laboratory conditions. Nylon and PTFE bristles removed a promising amount of dust from AZ93, and nylon and Thunderon bristles from AlFEP. But when these were tested under simulated lunar conditions in the lunar dust adhesion bell jar (LDAB), they were not effective. In a third effort, seven brushes made up of three different materials, two different geometries, and different bristle lengths and thicknesses were tested under laboratory conditions against AZ93 and AlFEP. Two of these brushes, the Zephyr fiberglass fingerprint brush and the Escoda nylon fan brush, removed over 90 percent of the dust, and so were tested in the fourth effort in the LDAB. They also performed well under these conditions recovering 80 percent or more of the original thermal performance (solar absorptance/thermal emittance) of both AZ93 and AgFEP after 20 strokes, and 90 or more percent after 200 strokes

Gaier, James R.

Predicting Selective Laser Printing Print Quality of Polymer Powders through Melt Flow Index

Selective Laser Sintering (SLS) uses a precisely controlled laser to fuse polymer powder to build complex 3D shapes. While SLS covers a wide application space, the processing knowledge of polymer powder is limited, restricting the number of commercial powders available. This study serves to expand the processing knowledge of polypropylene and polyethylene in parallel with a “mature” SLS feedstock, nylon, through melt flow index (MFI) characterization. Differential Scanning Calorimetry (DSC) was used to explore the sintering window of the polymers. Polyethylene and polypropylene exhibited a relatively narrow sintering window between 4 – 5 °C, whereas the sintering window of nylon was much wider, between 23 – 24 °C. This suggests that the print quality between polyethylene and polypropylene would be similar; however, X-ray computed tomography revealed a higher volume of print defects, voids, and de lamination in polyethylene than in polypropylene. MFI analysis provided additional insight into the difference in print quality, as the MFI of polyethylene was 7.16 g/10 min, 9.95 g/10 min for polypropylene, and 17.23 g/10 min for nylon. MFI is inversely correlated to melt viscosity, and a low melt viscosity is desired for proper coalescing between the layers and particles. These results suggest that MFI is a promising tool, in conjunction with traditional thermal analysis, for screening candidate powder feedstocks for SLS and optimization of print parameters for novel powders.

36 MATERIALS SCIENCE

Effects of material composition on the ablation performance of low density elastomeric ablators

The ablation performance of materials composed of various concentrations of nylon, hollow silica spheres, hollow phenolic spheres, and four elastomeric resins was determined. Both blunt-body and flat-panel specimens were used, the cold-wall heating-rate ranges being 0.11 to 0.8 MW/sq m, respectively. The corresponding surface pressure ranges for these tests were 0.017 to 0.037 atmosphere and 0.004 to 0.005 atmosphere. Some of the results show that (1) the addition of nylon significantly improved the ablation performance, but the nylon was not compatible with one resin system; (2) panel and blunt-body specimen data do not show the same effect of phenolic sphere content on ablation effectiveness; and (3) there appears to be an optimum concentration of hollow silica spheres for good ablation performance. The composition of an efficient, nonproprietary ablator for lifting body application is identified and the ablation performance of this ablator is compared with the performance of three commercially available materials.

Tompkins, S. S.

Tests of protective clothing for the safe handling of pressurized lamps

Tests were made to find a clothing material combination for use in handling high-pressure lamps. Monofilament nylon, ballistic nylon, and ballistic felt grouped into various multilayer combinations and chromed leather were positioned around and 30 cm (12 in.) away from exploding high-pressure lamps of different manufacturers and wattages. The results are: (1) 5024 nylon/ballistic felt/5024 nylon in a layered configuration was not penetrated by fragments of lamps as large as 6.5 kW; (2) this layered combination is lightweight and pliable and offers greater mobility and comfort to the user than previous protective clothing; and (3) Lexan plastic 1.6 mm (1/6 in.) thick to be used for face shield material showed no penetration for lamps as large as 20 kW.

Ewashinka, J. G.

Adhesion between polymers and evaporated gold and nickel films

To obtain information on the adhesion between metal films and polymeric solids, the adhesion force was measured by means of a tensile pull test. It was found that the adhesion strengths between polymeric solids and gold films evaporated on polymer substrates were (1.11 + or - 0.53) multiplied by 10(6) N/M(2) on PTFE, about 5.49 multiplied by 10(6) N/m(2) on UHMWPE, and 6.54x10(6) on 6/6 nylon. The adhesion strengths for nickel films evaporated on PTFE, UHMWPE, and 6/6 nylon were found to be a factor of 1.7 higher than those for the gold coated PTFE, UHMWPE, and 6/6 nylon. To confirm quantitatively the effect of electron irradiation on the adhesion strength between a PTFE solid and metal films, a tensile pull test was performed on the irradiated PTFE specimens, which were prepared by evaporating nickel or gold on PTFE surfaces irradiated by 2-keV electrons for various times. After irradiation, the adhesion strength increased to (4.92 + or - 0.92)x10(6) N/m(2) for nickel coated PTFE and (1.82 + or - 0.48)x10(6) N/m(2) for gold coated PTFE. The improvement in adhesion for nickel is higher than that for gold.

Yamada, Y.

Investigation of catalytic reduction and filter techniques for simultaneous measurements of NO, NO2, and HNO3 in the stratosphere

A concept for measuring stratospheric NOy-species is presented which utilizes the catalytic reduction of NO2 and HNO3 over heated metal catalysts and the chemisorption of HNO3 on Nylon. Using the Max Planck Institute for Aeronomy (MPAE) chemiluminescent balloon-borne sonde, stratospheric NO and NO2 profiles have been measured since 1983. NO is detected by chemiluminescence produced in reaction with O3 while NO2 needs first to be converted to NO over a heated stainless steel catalyst. To improve this technique for simultaneously measuring HNO3, the catalytic reduction of NO2 and HNO3 over several metal catalysts and the chemisorption of NO2 and HNO3 on Nylon have been investigated in laboratory tests. The results of these tests under simulated stratospheric conditions are presented in detail in this paper. They demonstrate that the simultaneous measurement of NO, NO2 and HNO3 is indeed possible with the combination of stainless steel or Au as a catalyst and a nylon filter.

Wendt, J.

Contamination sampling device

A contamination sample collection device has a wooden dowel with a cotton swab at one end, the cotton being covered by a nylon cloth and the wooden dowel being encapsulated by plastic tubing which is heat shrunk onto the dowel and onto a portion of the cotton swab to secure the cotton in place. Another plastic tube is heat shrunk onto the plastic that encapsulates the dowel and a portion of the nylon cloth to secure the nylon cloth in place. The device may thereafter be covered with aluminum foil protector. The device may be used for obtaining samples of contamination in clean room environments.

Delgado, Felix A.

Composite-Material Tanks with Chemically Resistant Liners

Lightweight composite-material tanks with chemically resistant liners have been developed for storage of chemically reactive and/or unstable fluids . especially hydrogen peroxide. These tanks are similar, in some respects, to the ones described in gLightweight Composite-Material Tanks for Cryogenic Liquids h (MFS-31379), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 58; however, the present tanks are fabricated by a different procedure and they do not incorporate insulation that would be needed to prevent boil-off of cryogenic fluids. The manufacture of a tank of this type begins with the fabrication of a reusable multisegmented aluminum mandrel in the shape and size of the desired interior volume. One or more segments of the mandrel can be aluminum bosses that will be incorporated into the tank as end fittings. The mandrel is coated with a mold-release material. The mandrel is then heated to a temperature of about 400 F (approximately equal to 200 C) and coated with a thermoplastic liner material to the desired thickness [typically approxiamtely equal to 15 mils (approximately equal to 0.38 mm)] by thermal spraying. In the thermal-spraying process, the liner material in powder form is sprayed and heated to the melting temperature by a propane torch and the molten particles land on the mandrel. The sprayed liner and mandrel are allowed to cool, then the outer surface of the liner is chemically and/or mechanically etched to enhance bonding of a composite overwrap. The etched liner is wrapped with multiple layers of an epoxy resin reinforced with graphite fibers; the wrapping can be done either by manual application of epoxy-impregnated graphite cloth or by winding of epoxy-impregnated filaments. The entire assembly is heated in an autoclave to cure the epoxy. After the curing process, the multisegmented mandrel is disassembled and removed from inside, leaving the finished tank. If the tank is to be used for storing hydrogen peroxide, then the liner material should be fluorinated ethylene/propylene (FEP), and one or more FEP O ring(s) should be used in the aluminum end fitting(s). This choice of materials is dictated by experimental observations that pure aluminum and FEP are the only materials suitable for long-term storage of hydrogen peroxide and that other materials tend to catalyze the decomposition of hydrogen peroxide to oxygen and water. Other thermoplastic liner materials that are suitable for some applications include nylon 6 and polyethylene. The processing temperatures for nylon 6 are lower than those for FEP. Nylon 6 is compatible with propane, natural gas, and other petroleum-based fuels. Polyethylene is compatible with petroleum- based products and can be used for short-term storage of hydrogen peroxide.

DeLay, Thomas K.

Latent Catalysis as a Platform for Accessing Diverse Material Properties in Vat Photopolymerization 3D Printing

Vat photopolymerization (VP) 3D printing is an attractive strategy to manufacture customized polymer parts. The properties of printed materials are limited by the need to employ a low viscosity liquid resin and achieve rapid polymerization kinetics. To circumvent this limitation, dual‐cure methods have been developed using reagents embedded in the liquid resin formulation; however, the reagent‐based approach requires the discovery and optimization of new chemistry for each desired material. Here, in this work, we demonstrate a catalytic, dual‐cure platform that enables access to both Nylon‐6 and polyester interpenetrating networks through VP 3D printing under a universal approach. Structure–reactivity relationships of the latent NHC catalysts led to the identification of a magnesium chloride–NHC adduct as a latent catalyst that is orthogonal to radical polymerization and can be unmasked at elevated temperatures post‐printing to initiate ring‐opening polymerization of lactones and lactams. This strategy results in access to semicrystalline materials, which are a challenging morphology to access via VP 3D printing, that have attractive mechanical properties and can be printed at high resolution. This work represents the first photochemical‐based 3D printing of Nylon‐based materials and demonstrates the value of catalytic approaches to access new material properties in VP 3D printing.

Colliver, Cali N. [University of North Carolina, C