Engineering PapersSearch

SEARCH · Engineering Papers

Results for “noninvasive monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Advance techniques for monitoring human tolerance to positive Gz accelerations

Tolerance to positive g accelerations was measured in ten normal male subjects using both standard and advanced techniques. In addition to routine electrocardiogram, heart rate, respiratory rate, and infrared television, monitoring techniques during acceleration exposure included measurement of peripheral vision loss, noninvasive temporal, brachial, and/or radial arterial blood flow, and automatic measurement of indirect systolic and diastolic blood pressure at 60-sec intervals. Although brachial and radial arterial flow measurements reflected significant cardiovascular changes during and after acceleration, they were inconsistent indices of the onset of grayout or blackout. Temporal arterial blood flow, however, showed a high correlation with subjective peripheral light loss.

Pelligra, R.

An innovative approach to the development of a portable unit for analytical flame characterization in a microgravity environment

The availability of manned laboratory facilities in space offers wonderful opportunities and challenges in microgravity combustion science and technology. In turn, the fundamentals of microgravity combustion science can be studied via spectroscopic characterization of free radicals generated in flames. The laser-induced fluorescence (LIF) technique is a noninvasive method of considerable utility in combustion physics and chemistry suitable for monitoring not only specific species and their kinetics, but it is also important for imaging of flames. This makes LIF one of the most important tools for microgravity combustion science. Flame characterization under microgravity conditions using LIF is expected to be more informative than other methods aimed at searching for effects like pumping phenomenon that can be modeled via ground level experiments. A primary goal of our work consisted in working out an innovative approach to devising an LIF-based analytical unit suitable for in-space flame characterization. It was decided to follow two approaches in tandem: (1) use the existing laboratory (non-portable) equipment and determine the optimal set of parameters for flames that can be used as analytical criteria for flame characterization under microgravity conditions; and (2) use state-of-the-art developments in laser technology and concentrate some effort in devising a layout for the portable analytical equipment. This paper presents an up-to-date summary of the results of our experiments aimed at the creation of the portable device for combustion studies in a microgravity environment, which is based on a portable UV tunable solid-state laser for excitation of free radicals normally present in flames in detectable amounts. A systematic approach has allowed us to make a convenient choice of species under investigation, as well as the proper tunable laser system, and also enabled us to carry out LIF experiments on free radicals using a solid-state laser tunable in the UV.

Dubinskiy, Mark A.

Spatial Phase Imaging

Frequently, scientists grow crystals by dissolving a protein in a specific liquid solution, and then allowing that solution to evaporate. The methods used next have been, variously, invasive (adding a dye that is absorbed by the protein), destructive (crushing protein/salt-crystal mixtures and observing differences between the crushing of salt and protein), or costly and time-consuming (X-ray crystallography). In contrast to these methods, a new technology for monitoring protein growth, developed in part through NASA Small Business Innovation Research (SBIR) funding from Marshall Space Flight Center, is noninvasive, nondestructive, rapid, and more cost effective than X-ray analysis. The partner for this SBIR, Photon-X, Inc., of Huntsville, Alabama, developed spatial phase imaging technology that can monitor crystal growth in real time and in an automated mode. Spatial phase imaging scans for flaws quickly and produces a 3-D structured image of a crystal, showing volumetric growth analysis for future automated growth.

Source record

Noninvasive Intracranial Volume and Pressure Measurements Using Ultrasound (Head and Spinal)

Prevention of secondary brain injuries following head trauma can be accomplished most easily when intracranial pressure (ICP) is monitored. However, current measurement techniques are invasive and thus not practical in the combat environment. The Pulsed Phase Lock Loop device, which was developed and patented by consultants Drs. Yost and Cantrell, uses a unique, noninvasive ultrasonic phase comparison method to measure slight changes in cranial volume which occur with changes in ICP. Year two studies included whole body head-up and head-down tilting effects on intracranial compliance and pressure in six healthy volunteers.

Hargens, Alan R.

Data Collection and Analysis Software Development for Rotor Dynamics Testing in Spin Laboratory

Gas turbine engine components undergo high rotational loading another complex environmental conditions. Such operating environment leads these components to experience damages and cracks that can cause catastrophic failure during flights. There are traditional crack detections and health monitoring methodologies currently being used which rely on periodic routine maintenances, nondestructive inspections that often times involve engine and components dis-assemblies. These methods do not also offer adequate information about the faults, especially, if these faults at subsurface or not clearly evident. At NASA Glenn research center, the rotor dynamics laboratory is presently involved in developing newer techniques that are highly dependent on sensor technology to enable health monitoring and prediction of damage and cracks in rotor disks. These approaches are noninvasive and relatively economical. Spin tests are performed using a subscale test article mimicking turbine rotor disk undergoing rotational load. Non-contact instruments such as capacitive and microwave sensors are used to measure the blade tip gap displacement and blade vibrations characteristics in an attempt develop a physics based model to assess/predict the faults in the rotor disk. Data collection is a major component in this experimental-analytical procedure and as a result, an upgrade to an older version of the data acquisition software which is based on LabVIEW program has been implemented to support efficiently running tests and analyze the results. Outcomes obtained from the tests data and related experimental and analytical rotor dynamics modeling including key features of the updated software are presented and discussed.

Rotor Dynamics

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS

NASA Tech Briefs, January 2001

The topics include: 1) A "Model" of Interactive Engineering; 2) Feature Section: Communications Technology; 3) lnReview; 4) Application Briefs; 5) Submillimeter-Wave Image Sensor; 6) Ultrasonic/Sonic Drill/Corers With Integrated Sensors; 7) Normally Closed, Piezoelectrically Actuated Microvalve; 8) Magnetostrictively Actuated Valves for Cryosurgical Probes; 9) Remote Sensing of Electric Fields in Clouds; 10) Wireless-Communication Headset Subsystem To Enhance Signaling; 11) Power Amplifier With 9 to 13 dB of Gain From 65 to 146 GHz; 12) Humidity Interlock for Protecting a Cooled Laser Crystal; 13) A Lightweight Ambulatory Physiological Monitoring System; 14) Improvements in a Lightning-Measuring Instrument; 15) Broad-Band, Noninvasive Radio-Frequency Current Probe; 16) Web-Based Technology Distributes Lean Models; 17) Software Guides Aeroelastic-Systems Design; and 18) Postprocessing Software for Micromechanics Analysis Code. A Photonics West 2001 Preview Tech Brief supplement to this January 2001 issue is also included.

Source record

High-Sensitivity DNA Aptasensors for Detecting Salivary Biomarker S100A7 in Heart Failure

Early detection of heart failure (HF) is vital for improving patient outcomes, lowering hospital readmission rates, and enabling prompt treatment. We present the first high-affinity DNA aptamer for the salivary HF biomarker S100A7 and its application in highly sensitive, noninvasive diagnostic tests. Iterative truncation of the initial 82-nt aptamer (17–82) produced a 43-nt core (17–43) with a binding affinity of 27 nM, which was further enhanced to 5.5 nM through dimerization. Biochemical and mutational studies confirmed that 17–43 adopts a G-quadruplex structure, which is essential for S100A7 recognition and resistance to enzymatic degradation in human saliva. Incorporating 17–43 into sandwich aptamer-ELISA and hybrid aptamer–antibody ELISA assays allowed detection of recombinant S100A7 in human saliva with limits of detection (LOD) of 7.4 ng mL–1 (0.6 nM) and 29 pg/mL (2.2 pM), respectively-outperforming commercial immunoassays in both sensitivity and dynamic range. The hybrid assay maintained its full performance after 2.5 months of room temperature storage. Additionally, a biolayer interferometry (BLI) sensor with 17–43 quantified S100A7 in patient saliva (n = 3), achieving a LOD of 3.2 ng mL–1 (0.3 nM) with a total assay time of less than 20 min. The aptamer’s stability, high specificity, and versatility across biosensing platforms establish it as a promising tool for noninvasive heart failure diagnostics, laying the groundwork for portable aptamer-based biosensors for multiplexed monitoring of HF biomarkers.

DNA aptamer

Densitography - A new method for evaluation of cardiac performance of rest and during exercise.

The validity of the densitographic curves obtained from the pinna of the ear for measuring the systolic intervals has been investigated in 28 subjects. This technique is found to permit the performance of noninvasive physiologic studies during physical activities, exercise tests, flight conditions, and probably long-term monitoring of critically ill patients. Densitographic curves constitute an excellent substitute by which to measure time-base intervals of the cardiac cycle when the carotid pulse tracing is not available.

Chirife, R.

Photonic Diagnostic Technique For Thin Photoactive Films

Photonic diagnostic technique developed for use in noninvasive, rapid evaluation of thin paraelectric/ferroelectric films. Method proves useful in basic research, on-line monitoring for quality control at any stage of fabrication, and development of novel optoelectronic systems. Used to predict imprint-prone memory cells, and to study time evolution of defects in ferroelectric memories during processing. Plays vital role in enabling high-density ferroelectric memory manufacturing. One potential application lies in use of photoresponse for nondestructive readout of polarization memory states in high-density, high-speed memory devices. In another application, extension of basic concept of method makes possible to develop specially tailored ferrocapacitor to act as programmable detector, wherein remanent polarization used to modulate photoresponse. Large arrays of such detectors useful in optoelectronic processing, computing, and communication.

Thakoor, Sarita

In Vivo Noninvasive Analysis of Human Forearm Muscle Function and Fatigue: Applications to EVA Operations and Training Maneuvers

Forearm muscle fatigue is one of the major limiting factors affecting endurance during performance of deep-space extravehicular activity (EVA) by crew members. Magnetic resonance (MR) provides in vivo noninvasive analysis of tissue level metabolism and fluid exchange dynamics in exercised forearm muscles through the monitoring of proton magnetic resonance imaging (MRI) and phosphorus magnetic resonance spectroscopy (P-31-MRS) parameter variations. Using a space glove box and EVA simulation protocols, we conducted a preliminary MRS/MRI study in a small group of human test subjects during submaximal exercise and recovery and following exhaustive exercise. In assessing simulated EVA-related muscle fatigue and function, this pilot study revealed substantial changes in the MR image longitudinal relaxation times (T2) as an indicator of specific muscle activation and proton flux as well as changes in spectral phosphocreatine-to-phosphate (PCr/Pi) levels as a function of tissue bioenergetic potential.

Fotedar, L. K.

Noninvasive Intracranial Pressure and Tissue Oxygen Measurements for Space and Earth

The paper discusses the following: Increasing intracranial pressure in humans during simulated microgravity. and near-infrared monitoring of model chronic compartment syndrome in exercising skeletal muscle. Compared to upright-seated posture, 0 deg. supine, 6 deg. HDT, and 15 deg. HDT produced TMD changes of 317 +/- 112, 403 +/- 114, and 474 +/- 112 n1 (means +/- S.E.), respectively. Furthermore, postural transitions from 0 deg. supine to 6 deg. HDT and from 6 deg. to 15 deg. HDT generated significant TMD changes (p less than 0.05). There was no hysteresis when postural transitions to HDT were compared to reciprocal transitions toward upright seated posture. Currently, diagnosis of chronic compartment syndrome (CCS) depends on measurement of intramuscular pressure by invasive catheterization. We hypothesized that this syndrome can be detected noninvasively by near-infrared (NIR) spectroscopy, which tracks variations in muscle hemoglobin/myoglobin oxygen saturation. CCS was simulated in the tibialis anterior muscle of 7 male and 3 female subjects by gradual inflation of a cuff placed around the leg to 40 mmHg during 14 minutes of cyclic isokinetic dorsiflexion exercise. On a separate day, subjects underwent the identical exercise protocol with no external compression. In both cases, tissue oxygenation (T(sub O2) was measured in the tibialis anterior by NIR spectroscopy and normalized to a percentage scale between baseline and a T(sub O2) nadir reached during exercise to ischemic exhaustion. Over the course of exercise, T(sub O2) declined at a rate of 1.4 +/- 0.3% per minute with model CCS, yet did not decrease during control exercise. Post-exercise recovery of T(sub O2) was slower with model CCS (2.5 +/- 0.6 min) than in control (1.3 +/- 0.2 min). These results demonstrate that NIR spectroscopy can detect muscle deoxygenation caused by pathologically elevated intramuscular pressure in exercising skeletal muscle. Consequently, this technique shows promise as a noninvasive diagnostic tool for CCS.

Hargens, A. R.

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Novel Approaches to Cellular Transplantation from the US Space Program

Research in the treatment of type I diabetes is entering a new era that takes advantage of our knowledge in an ever increasing variety of scientific disciplines. Some may originate from very diverse sources, one of which is the Space Program at National Aeronautics and Space Administration (NASA). The Space Program contributes to diabetes-related research in several treatment modalities. As an ongoing effort for medical monitoring of personnel involved in space exploration activities NASA and the extramural scientific community investigate strategies for noninvasive estimation of blood glucose levels. Part of the effort in the space protein crystal growth program is high-resolution structural analysis insulin as a means to better understand the interaction with its receptor and with host immune components and as a basis for rational design of a "better" insulin molecule. The Space Program is also developing laser technology for potential early cataract detection as well as a noninvasive analyses for addressing preclinical diabetic retinopathy. Finally, NASA developed an exciting cell culture system that affords some unique advantages in the propagation and maintenance of mammalian cells in vitro. The cell culture system was originally designed to maintain cell suspensions with a minimum of hydrodynamic and mechanical sheer while awaiting launch into microgravity. Currently the commercially available NASA bioreactor (Synthecon, Inc., Houston, TX) is used as a research tool in basic and applied cell biology. In recent years there is continued strong interest in cellular transplantation as treatment for type I diabetes. The advantages are the potential for successful long-term amelioration and a minimum risk for morbidity in the event of rejection of the transplanted cells. The pathway to successful application of this strategy is accompanied by several substantial hurdles: (1) isolation and propagation of a suitable uniform donor cell population; (2) management of host immune rejection; (3) protection from the autoimmune component of the disease; and (4) anatomic placement of the engrafted cells that permits timely response to blood sugar levels as well as effective release and deployment of insulin. Bioreactor technology may provide some critical advances for surmounting some of these scientific hurdles. The NASA bioreactor is a horizontally rotating cylinder that is completely filled with culture medium. Gaseous exchange is maintained by a concentric cylinder of permeable silicon. In slow rotation (15-25 rpm) particles of small mass such as cells and tissue aggregates remain suspended in the rotating body of fluid. This novel approach suspends cells without stirring thus, allowing objects of different size mass to colocate and interact in a very low shear environment. In fact, analysis of the forces acting on individual cells in the rotating bioreactor reveals that the cells are continuously falling through the fluid medium. The conditions in the bioreactor permit assembly of cells into aggregates. three-dimensional tissue growth, synthesis of intercellular matrix,10 differentiation, and some sinusoid formations that may serve as a surrogate vasculature for larger tissue segments.

Pellis, Neal R.

Remote sensing of Pu in uranyl nitrate crystals using reflectance spectroscopy and chemometrics

Remote quantification of Pu(VI) (0–5 mol%) co-crystallized with U in uranyl nitrate hexahydrate (UNH) crystals was achieved in a glove box using reflectance spectroscopy coupled with chemometric modeling. Reflectance spectra were also acquired for Pu(IV) and Np(VI) (0–5 mol%) crystallized with UNH; revealing spectral features consistent with their solution-phase analogs. Principal component analysis revealed Pu(IV/VI) and Np(VI) concentrations as the primary source of variation in the data, informing the development of a supervised partial least squares regression model for Pu(VI). The resulting calibration demonstrated robust performance, with replicate root mean square errors near 10% and quantifiable limits near 0.2 mol% Pu(VI) relative to U. The Pu(VI) remained stable in the crystalline UNH matrix for at least one week with minimal reduction to Pu(IV). Notably, Pu(VI) and Np(VI) incorporation in UNH quenched U(VI) fluorescence while Pu(IV) did not. This study presents a noninvasive, spectroscopic approach for solid-state Pu quantification, with direct implications for material accountability and nuclear nonproliferation monitoring.

Sadergaski, Luke R. [Oak Ridge National Laboratory

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe

Optical distributed sensors for feedback control: Characterization of photorefractive resonator

The aim of the project was to explore, define, and assess the possibilities of optical distributed sensing for feedback control. This type of sensor, which may have some impacts in the dynamic control of deformable structures and the monitoring of small displacements, can be divided into data acquisition, data processing, and control design. Analogue optical techniques, because they are noninvasive and afford massive parallelism may play a significant role in the acquisition and the preprocessing of the data for such a sensor. Assessing these possibilities was the aim of the first stage of this project. The scope of the proposed research was limited to: (1) the characterization of photorefractive resonators and the assessment of their possible use as a distributed optical processing element; and (2) the design of a control system utilizing signals from distributed sensors. The results include a numerical and experimental study of the resonator below threshold, an experimental study of the effect of the resonator's transverse confinement on its dynamics above threshold, a numerical study of the resonator above threshold using a modal expansion approach, and the experimental test of this model. A detailed account of each investigation, including methodology and analysis of the results are also included along with reprints of published and submitted papers.

Indebetouw, Guy

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.