Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noise shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

62 records · Page 4

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media

SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.

58 GEOSCIENCES↗

Performance Comparison of Machine Learning Models for Ultrasonic Nondestructive Evaluation of Alkali-Silica Reaction in Concrete

Alkali-silica reaction (ASR) causes concrete degradation, leading to cracking, rebar corrosion, and reduced structural integrity, which raises safety concerns. Ultrasonic nondestructive evaluation (NDE) effectively assesses concrete properties and monitors ASR progression. However, its deployment and analysis require specialized expertise and subjective interpretation. As computational power increases, artificial intelligence (AI) and machine learning (ML) algorithms are increasingly being used to automate NDE data analysis across various industries for AI-assisted automation. Regulatory agencies are adapting to this technological shift, prompting a need to evaluate current ML technologies’ capabilities and limitations in assessing concrete material properties and damage. This report presents a comparative analysis of four ML regression models for predicting concrete material damage induced by ASR expansion using long-term ultrasonic data monitoring. The models investigated include linear regression (LR), support vector regression (SVR), shallow neural networks (NN), and deep neural networks (DNN). LR, SVR, and shallow NN models use features extracted from ultrasonic signals, whereas the DNN model processes time-domain ultrasonic signals and frequency spectra directly. The study systematically compared the models’ performance from various perspectives, including model input, prediction performance, and generalization ability. The findings indicate significant variability in model performance, with some ML algorithms achieving very high or very low prediction accuracy depending on the preprocessing and feature engineering (extraction and selection) applied. Key insights include the observation that shallow ML models (LR, SVR, and shallow NNs) require meticulous preprocessing and feature extraction to achieve high accuracy. In contrast, the DNN model, although it bypasses the need for feature engineering, necessitates extensive preprocessing to mitigate noise and computational demands. The SVR model emerged as the top performer among the shallow models, and the DNN model exhibited superior performance on specific datasets but struggled with generalization across specimens from different batches. Additionally, the SVR model is sensitive to temperature variations, whereas the DNN model is robust in this regard. Using recurrent neural networks is recommended for future ASR expansion prediction studies. Recurrent neural networks’ inherent ability to capture temporal dependencies and long-term patterns makes them well suited for analyzing sequential ultrasonic monitoring data. Overall, the results and conclusions of this study could provide insights into the capabilities and effectiveness of ML when applied to ultrasonic NDE data and help identify best practices for using ML for ultrasonic NDE of concrete material properties.

36 MATERIALS SCIENCE↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: I. Stability

Ion cyclotron emission (ICE) driven by fast ions has the potential to be a reactor relevant diagnostic of confined and escaping fast ions; moreover, controlled experiments in magnetic fusion devices can shed light on similar magnetospheric instabilities below and above the ion cyclotron frequency f ci . Dedicated DIII-D experiments studied instabilities below f ci and at cyclotron harmonics l f ci by injecting thirteen different neutral beam populations into plasmas with different thermal compositions of H, D, and 3He at five different values of toroidal field. High-frequency magnetic loops diagnose mode properties. Each beam type is individually injected for an approximate slowing-down time (~100 ms), resulting in a database of 2529 conditions that are analyzed in frequency bands corresponding to ICE harmonics and < f ci global Alfvén eigenmodes. The sub-cyclotron modes are more unstable at low field and in plasmas with large H concentration. For D injection, first harmonic ICE at f cD is more unstable in hydrogen plasmas but, for H injection, the converse is true (ICE at f cH is more unstable in D), suggesting that thermal same-species ions damp fundamental ICE. ICE stability also depends upon the pitch-angle anisotropy gradient and upon the ‘bump-on-tail’ gradient ∂f/∂v. Although the frequency of unstable ICE in these plasmas always occurs near the central cyclotron frequency, the precise value also depends on the Alfvén speed and beam direction, consistent with the idea that instability occurs for modes that simultaneously satisfy ω ≃ 2πlf ci , the magnetosonic dispersion relation, and the Doppler-shifted resonance condition.

electromagnetic ion cyclotron instabilities↗

Parametric amplification of spin-motion coupling in three-dimensional trapped-ion crystals

Three-dimensional (3D) crystals offer a route to scaling up trapped-ion systems for quantum sensing and quantum simulation applications; however, engineering coherent spin-motion couplings and effective spin-spin interactions in large crystals poses technical challenges associated with decoherence and prolonged timescales to generate appreciable entanglement. Here, we explore the possibility of speeding up these interactions in 3D crystals via parametric amplification. For this purpose, we derive a general Hamiltonian for the parametric amplification of spin-motion coupling that is broadly applicable to normal modes with motion transverse to or along the spatial extent of the crystal. Unlike in lower-dimensional crystals, we find that the ability to faithfully (uniformly) amplify the spin-spin interactions in 3D crystals depends on the physical implementation of the spin-motion coupling. We consider the light-shift gate, and the so-called phase-insensitive and phase-sensitive Mølmer-Sørensen (MS) gates, and we find that only the phase-sensitive MS gate can be faithfully amplified in general 3D crystals. We discuss a situation where nonuniform amplification can be advantageous. We also reconsider the effect of counter-rotating terms on parametric amplification and find that they are not as detrimental as previous studies suggest.

Optical parametric oscillators & amplifiers↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗