Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noise amplification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

65 records · Page 4

Phase-sensitive optomechanical amplifier for quantum noise reduction in laser interferometers

The sensitivity of future gravitational wave interferometers is expected to be limited throughout the detection band by quantum vacuum fluctuations, which can be reduced by applying quantum optics techniques such as squeezed vacuum injection. However, decoherence caused by optical losses in the readout chain will severely limit the effectiveness of such schemes. It was proposed that effect of losses in the final stage of detection can be mitigated by a phase-sensitive amplifier placed in between the output port of the interferometer and the photodetector. In this paper we propose to implement such amplification using an optomechanical device, study some of its practical limitations, and finally, discuss its applicability to next-generation gravitational-wave detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting seismic amplitudes with machine learning

The accurate estimation of seismic wave amplitude is vital to precisely determine the yield, magnitude, and event discrimination possible for a given network – a critical element in nuclear explosion monitoring. This task is complicated by several factors, including but not limited to radiation pattern, scattering effects, and crustal variations, which can lead to the attenuation or amplification of amplitude along a given raypath. In this report, we explore the novel application of machine learning to the task of seismic amplitude estimation by training a simple Artificial Neural Network (ANN) on an S-wave amplitude dataset from Lai et al. (2019). Attributes from this dataset used as input to the ANN included event-station distances, station locations (latitude, longitude), event locations (latitude, longitude), event depths, event magnitudes, radiation patterns, signal-to noise ratio (SNR) measurements (average-amplitude, peak-to-trough, maximum peak), and signal periods. We find that the trained ANN predicts S-wave amplitudes with a modest tendency toward underestimating the actual values, as indicated by a linear regression between predicted and actual data (slope: 0.892, intercept: -0.651). These results suggest that an ANN can perform this task, with potential for significant improvements through improved datasets, architectures, and parameter tuning.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Resolution Near-Surface Imaging at the Basin Scale Using Dark Fiber and Distributed Acoustic Sensing: Toward Site Effect Estimation in Urban Environments

Near-surface seismic structure, particularly the shear wave velocity (V s ), can strongly affect local site response, and should be accurately estimated for ground motion prediction during seismic hazard assessment. The Imperial Valley (California), occupying the southern end of the Salton Trough, is a seismically active basin with thick surficial lacustrine sedimentary deposits. In this study, we utilize ambient noise records and local earthquake events for high-resolution near-surface characterization and site effect estimation with an unlit fiber-optic telecommunication infrastructure (dark fiber) in Imperial Valley by using the distributed acoustic sensing (DAS) technique. We apply ambient noise interferometry to retrieve coherent surface waves from DAS records, and evaluate performances of three different surface wave methods on DAS ambient noise dispersion imaging. We develop a quality control workflow to improve the dispersion measurement of noisy portions of the DAS data set by using a data selection strategy. Using the joint inversion of both the fundamental mode and higher overtones of Rayleigh waves, a high resolution two-dimensional (2D) V s structure down to 70 m depth is obtained. We successfully achieve an improved V s 30 (the time-averaged shear-wave velocity in the top 30 m) model with higher spatial-resolution and reliability compared to the existing community model for the area. We also explore the potential for utilizing DAS earthquake events for site amplification estimation. The preliminary results reveal a clear anti-correlation between the approximated site response and the V s 30 profile. In conclusion, our results indicate the potential utility of DAS deployed on dark fiber for near-surface characterization in appropriate contexts.

58 GEOSCIENCES↗

Fundamental limits to the generation of highly displaced bright squeezed light using linear optics and parametric amplifiers

High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing. Published by the American Physical Society 2025

Young, Steve M. (ORCID:0000000173839366)↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Parametric amplification of spin-motion coupling in three-dimensional trapped-ion crystals

Three-dimensional (3D) crystals offer a route to scaling up trapped-ion systems for quantum sensing and quantum simulation applications; however, engineering coherent spin-motion couplings and effective spin-spin interactions in large crystals poses technical challenges associated with decoherence and prolonged timescales to generate appreciable entanglement. Here, we explore the possibility of speeding up these interactions in 3D crystals via parametric amplification. For this purpose, we derive a general Hamiltonian for the parametric amplification of spin-motion coupling that is broadly applicable to normal modes with motion transverse to or along the spatial extent of the crystal. Unlike in lower-dimensional crystals, we find that the ability to faithfully (uniformly) amplify the spin-spin interactions in 3D crystals depends on the physical implementation of the spin-motion coupling. We consider the light-shift gate, and the so-called phase-insensitive and phase-sensitive Mølmer-Sørensen (MS) gates, and we find that only the phase-sensitive MS gate can be faithfully amplified in general 3D crystals. We discuss a situation where nonuniform amplification can be advantageous. We also reconsider the effect of counter-rotating terms on parametric amplification and find that they are not as detrimental as previous studies suggest.

Optical parametric oscillators & amplifiers↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

S-band acoustoelectric amplifier in an InGaAs-AlScN-SiC architecture

Here, we report on an acoustoelectric slab waveguide heterostructure for phonon amplification using a thin Al 0.58 Sc 0.42 N film grown directly on a 4H-SiC substrate with an ultra-thin In 0.53 Ga 0.47 As epitaxial film heterogeneously integrated onto the surface of the Al 0.58 Sc 0.42 N. The aluminum scandium nitride film grown directly on silicon carbide enables a thin (∼850 nm thick) piezoelectric film to be deposited on a thermally conductive bulk substrate (370 W/m K for 4H-SiC); the high thermal conductivity of the substrate, large mobility of the semiconductor (∼7000 cm 2 /V s), and low carrier concentration (∼5 × 10 15 cm −3 ) yield low self-heating. A Sezawa mode with optimal overlap between the peak of its evanescent electric field and the semiconductor charge carriers is supported. The high velocity of the heterostructure materials allows us to operate the Sezawa mode amplifier at 3.05 GHz, demonstrating a gain of 500 dB/cm (40 dB in 800 μm). Additionally, a terminal end-to-end radio frequency gain of 7.7 dB and a nonreciprocal transmission of 52.6 dB are achieved with a dissipated DC power of 2.3 mW. In conclusion, the power added efficiency and acoustic noise figure are also characterized.

Hackett, L.↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗