Applying Small Footprint Borehole Electric and Magnetic Field Sensors for Geophysical Monitoring Networks
A feasibility investigation into using optical fiber for interrogating arrays of piezoelectric sensors for Electromagnetic Surveying Applications.
Design of an AIM Network for Monitoring Carbon Storage Projects
Conference poster presented at Carbon Capture, Utilization, and Storage (CCUS) Conference 2024, Houston, Texas, March 11–13, 2024. The Energy & Environmental Research Center (EERC) is researching novel carbon storage-monitoring techniques at an approved North Dakota geologic carbon storage site. One of the research objectives is to design an autonomous, integrated, and modular (AIM) monitoring network that is compliant with monitoring requirements across multiple carbon capture and storage (CCS) policy frameworks, such as the U.S. Environmental Protection Agency’s (EPA) underground injection control (UIC) Class VI permitting program.
TECHNICAL EVALUATION OF THE INTERACTION OF GROUNDWATER WITH THE COLUMBIA RIVER AT THE DEPARTMENT OF ENERGY HANFORD SITE 100-D AREA
Groundwater beneath much of Hanford's 100 Areas is contaminated with hexavalent chromium (Cr{sup +6}) as a consequence of treating reactor cooling water to prevent corrosion. Several treatment systems are in place to remove Cr{sup +6} from the groundwater; however, these systems currently do not reduce Cr{sup +6} to concentrations below aquatic standards. Of concern is the transport of Cr{sup +6} to areas within the channel of the river, as sensitive species inhabit the river and its associated transition zone. The aquatic standard for Cr{sup +6} is currently 11 ug/l under the Record of Decision (ROD) for Interim Action and Department of Energy (DOE) currently plans to pursue remediation of the groundwater to achieve the 11 ug/l standard. Because the compliance wells used to monitor the current remediation systems are located some distance from the river, they may not provide an accurate indication of Cr{sup +6} concentrations in the water that reaches the riverbed. In addition, because salmon spawning areas are considered a high priority for protection from Hanford contaminants, it would be advantageous to understand (1) to what extent Cr{sup +6} discharged to the near-shore or river ecosystems is diluted or attenuated and (2) mechanisms that could mitigate the exposure of the river ecosystems to the discharging Cr{sup +6}. The current concentration target for Cr{sup +6} at near-river groundwater monitoring locations is 20 {micro}g/L; it is assumed that this groundwater mixes with river water that contains virtually no chromium to meet Washington Department of Ecology's (Ecology) water quality standard of 10 {micro}g/L in the river environment. This dynamic mixing process is believed to be driven by daily and seasonal changes in river stage and groundwater remediation system operations, and has been validated using analytical data from numerous groundwater samples obtained adjacent to and within the banks of the river. Although the mean mixing factor of river water and site groundwater in this zone has been estimated to be equal parts of groundwater and river water, a wide range of mixing ratios likely occurs at various times of the day and year. The degree of mixing and dilution appears to be greatly influenced by the river stage and other groundwater/surface water interaction. The extent of mixing, thus, has implications for the design and operation of the groundwater remediation systems. Improved understanding of this 'dilution' mechanism is needed to design an optimum 'systems approach' to accelerate remediation of the near-shore contaminant plumes. More information on the pathway from near-river mapped plumes to riverbed receptor locations is also needed to develop a defensible proposed plan for a future ROD for final remedial action of contaminated groundwater. In April 2008, an expert panel of scientists was convened to review existing information and provide observations and suggestions to improve the current understanding of groundwater surface water interactions in the 100 Areas (primarily focusing on 100-D Area), and to identify what additional analyses or approaches may provide critical information needed to design and implement remediation systems that will minimize impacts to river aquatic systems. Specific objectives provided to the panel included: (1) comment on approaches and methods to improve the current understanding of groundwater-surface water interactions, specifically how contaminated groundwater enters the riverbed and how this relates to remediation of chromate in the groundwater in the 100 Areas; (2) evaluate past and current data collection methods, data analysis techniques, assumptions, and groundwater transport and mixing mechanisms; (3) evaluate the current monitoring network (monitoring wells, aquifer tubes, and shoreline/river monitoring); (4) evaluate the role played by modeling; and (5) suggest additional research to fill data gaps and perform modeling.
Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing
Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.
Integrating 5G Technology for Improved Process Monitoring and Network Slicing in ICS
Industrial Control Systems (ICS) are crucial for monitoring physical processes that support essential cyber-enabled services like power generation. The use of proprietary communication and lack of effective intrusion detection mechanisms pose constraints for efficient operation. Therefore, there is a need to modernize these systems with decentralized technologies like Edge Computing and 5G. However, integrating 5G and Edge Computing into large-scale ICS networks presents implementation and performance challenges. To address these challenges, this paper proposes an integrated ICS architecture that combines 5G and Edge Computing technologies with traditional ICS protocols. The objective is to minimize implementation and operational difficulties while improving the monitoring of physical processes and enabling robust intrusion detection. The proposed architecture outlines the necessary components, services, and communication protocols required for the integration of 5G and Edge Computing.
Spatiotemporal interpolation of air pollutants in the Greater Cairo and the Delta, Egypt
Highlights: • Data from network of monitoring stations in Egypt are used for studying SO{sub 2}, NO{sub 2}, and PM{sub 10.} • Trans-Gaussian Spatiotemporal kriging is used as a spatiotemporal interpolation method. • The whole area under study is suffering from high values of PM{sub 10} throughout 2015. • For NO{sub 2} and SO{sub 2}, the highest value is noticed in February. • Concerns must be given to the monitoring network to improve the prediction precision. This paper analyses the spatiotemporal variability of air pollutants in Egypt using monthly averages from the air quality monitoring network from 2011 to 2015. Particulate Matters (PM{sub 10}) Nitrogen Dioxide (NO{sub 2}) and Sulfur Dioxide (SO{sub 2}), measured by the monitoring stations network are studied. A log transformation is applied for the three pollutants to achieve normality. The sum-metric function is utilized for modelling the spatiotemporal variogram as it gave the smallest Mean Squared Error (MSE) compared to other forms namely separable, metric, and product sum models. Therefore, employing the gstat package in R together with the trans-Gaussian spatiotemporal kriging, the maps are generated for the interpolated surfaces for the monthly averages of 2015 and the corresponding standard error values. These maps will help the decision maker to understand and visualize the spatial and temporal variability of the measured pollutants and hence undertake the necessary policies and decisions. The results show that the down town area has the highest pollutants levels. As concerns the temporal dimension, the highest values are depicted during the month of February as compared to the rest of the year. Furthermore, Egypt is suffering from a serious PM{sub 10} problem for the area and period under study that extremely exceed the WHO and Egyptian guidelines.
Evaluating the Observability of Network Security Monitoring Strategies With TOMATO
Not Available
Energy Sector Security through a System for Intelligent, Learning Network Configuration Monitoring and Management (“Essence”)
The project was conceived and executed with the overarching objective to provide cost effective tools to cooperative utilities that enabled them to quickly detect, characterize and take remediative action against cyber attacks.
Report on the Dagstuhl Seminar on Visualization and Monitoring of Network Traffic
The Dagstuhl Seminar on Visualization and Monitoring of Network Traffic [1] took place May 17-20, 2009 in Dagstuhl, Germany. Dagstuhl seminars promote personal interaction and open discussion of results as well as new ideas. Unlike at most conferences, the focus is not solely on the presentation of established results but to equal parts on results, ideas, sketches, and open problems. The aim of this particular seminar was to bring together experts from the information visualization community and the networking community in order to discuss the state of the art of monitoring and visualization of network traffic. People from the different research communities involved jointly organized the seminar. The co-chairs of the seminar from the networking community were Aiko Pras (University of Twente) and Jürgen Schönwälder (Jacobs University Bremen). The co-chairs from the visualization community were Daniel A. Keim (University of Konstanz) and Pak Chung Wong (Pacific Northwest National Lab). Florian Mansmann (University of Konstanz) helped with producing this report. The seminar was organized and supported by Schloss Dagstuhl and the EC IST-EMANICS Network of Excellence [1].
A New Approach to Multivariate Network Traffic Analysis
© 2019, Springer Science+Business Media, LLC & Science Press, China. Network traffic analysis is one of the core functions in network monitoring for effective network operations and management. While online traffic analysis has been widely studied, it is still intensively challenging due to several reasons. One of the primary challenges is the heavy volume of traffic to analyze within a finite amount of time due to the increasing network bandwidth. Another important challenge for effective traffic analysis is to support multivariate functions of traffic variables to help administrators identify unexpected network events intuitively. To this end, we propose a new approach with the multivariate analysis that offers a high-level summary of the online network traffic. With this approach, the current state of the network will display patterns compiled from a set of traffic variables, and the detection problems in network monitoring (e.g., change detection and anomaly detection) can be reduced to a pattern identification and classification problem. In this paper, we introduce our preliminary work with clustered patterns for online, multivariate network traffic analysis with the challenges and limitations we observed. We then present a grid-based model that is designed to overcome the limitations of the clustered pattern-based technique. We will discuss the potential of the new model with respect to the technical challenges including streaming-based computation and robustness to outliers.
G-NetMon: a GPU-accelerated network performance monitoring system
At Fermilab, we have prototyped a GPU-accelerated network performance monitoring system, called G-NetMon, to support large-scale scientific collaborations. In this work, we explore new opportunities in network traffic monitoring and analysis with GPUs. Our system exploits the data parallelism that exists within network flow data to provide fast analysis of bulk data movement between Fermilab and collaboration sites. Experiments demonstrate that our G-NetMon can rapidly detect sub-optimal bulk data movements.
Real-time In-situ CO 2 Monitoring (RICO2M) Network for Sensitive Subsurface Areas in CCUS
Intelligent Optical Systems (IOS) has developed the Real-Time In-Situ CO 2 Monitoring (RICO2M) system, a fiber optic-based monitoring system capable of the highly sensitive detection of increasing levels of carbon dioxide (CO 2 ) in groundwater. In collaboration with the Bureau of Economic Geology at the University of Texas at Austin, IOS performed multiple field deployments and validation studies of an in-situ real-time monitoring network. We have developed and demonstrated a multi-channel instrument capable of covering up to eight water wells, with a fabrication cost of ~$5,000, which compares very favorably with existing fiber optic monitoring instrumentation for downhole monitoring. Numerous field studies demonstrated the ability of the RICO2M system to detect small leaks of CO 2 reaching aquifers, and the capacity of the sensor probe to operate for at least one year before replacement. The final system design was a sensitive CO 2 leak detector; further development will be necessary to accurately quantify and monitor CO 2 concentrations in real time.
Data-Driven Method for Groundwater-Level Mapping and Monitoring-Well Network Optimization at Hanford
This report summarizes the initial results and outcomes of a physics-informed, data-driven groundwater level (GWL) mapping capability for the Hanford Site. GWL mapping at Hanford is typically conducted annually and requires a significant amount of computational and expert resources, and it does not allow assessment of the informational value of specific monitoring wells. The proposed method produces spatially and temporally resolved fields consistent with sparse, irregularly sampled, and nonuniformly distributed well measurements. Implemented successfully, this capability will allow rapid mapping of groundwater levels and provide an opportunity to optimize monitoring activities (both location and sampling frequency) based on data information value evaluation. The approach integrates a diffusion-based generative model – trained on MODFLOW simulation data from the Plateau-to-River (P2R) model – with score-based data assimilation (SDA), allowing observation-conditioned mapping without retraining for each monitoring-network layout.
Network Traffic Monitoring on the Basis of Sequential and Associative–Sequential Search Principles
Network traffic monitoring on the basis of sequential and associative–sequential principles of current- information search is assessed in terms of efficiency. Associative–sequential search for information in network traffic permits increased productivity and faster decision making during searches in large information spaces.
Learning Behavior of Distribution System Discrete Control Devices for Cyber-Physical Security
Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.
Understanding sources of organic aerosol during CalNex-2010 using the CMAQ-VBS
Abstract. Community Multiscale Air Quality (CMAQ) model simulations utilizing the traditional organic aerosol (OA) treatment (CMAQ-AE6) and a volatility basis set (VBS) treatment for OA (CMAQ-VBS) were evaluated against measurements collected at routine monitoring networks (Chemical Speciation Network (CSN) and Interagency Monitoring of Protected Visual Environments (IMPROVE)) and those collected during the 2010 California at the Nexus of Air Quality and Climate Change (CalNex) field campaign to examine important sources of OA in southern California. Traditionally, CMAQ treats primary organic aerosol (POA) as nonvolatile and uses a two-product framework to represent secondary organic aerosol (SOA) formation. CMAQ-VBS instead treats POA as semivolatile and lumps OA using volatility bins spaced an order of magnitude apart. The CMAQ-VBS approach underpredicted organic carbon (OC) at IMPROVE and CSN sites to a greater degree than CMAQ-AE6 due to the semivolatile POA treatment. However, comparisons to aerosol mass spectrometer (AMS) measurements collected at Pasadena, CA, indicated that CMAQ-VBS better represented the diurnal profile and primary/secondary split of OA. CMAQ-VBS SOA underpredicted the average measured AMS oxygenated organic aerosol (OOA, a surrogate for SOA) concentration by a factor of 5.2, representing a considerable improvement to CMAQ-AE6 SOA predictions (factor of 24 lower than AMS). We use two new methods, one based on species ratios (SOA/ΔCO and SOA/Ox) and another on a simplified SOA parameterization, to apportion the SOA underprediction for CMAQ-VBS to slow photochemical oxidation (estimated as 1.5 × lower than observed at Pasadena using −log(NOx : NOy)), low intrinsic SOA formation efficiency (low by 1.6 to 2 × for Pasadena), and low emissions or excessive dispersion for the Pasadena site (estimated to be 1.6 to 2.3 × too low/excessive). The first and third factors are common to CMAQ-AE6, while the intrinsic SOA formation efficiency for that model is estimated to be too low by about 7 × . From source-apportioned model results, we found most of the CMAQ-VBS modeled POA at the Pasadena CalNex site was attributable to meat cooking emissions (48 %, consistent with a substantial fraction of cooking OA in the observations). This is compared to 18 % from gasoline vehicle emissions, 13 % from biomass burning (in the form of residential wood combustion), and 8 % from diesel vehicle emissions. All "other" inventoried emission sources (e.g., industrial, point, and area sources) comprised the final 13 %. The CMAQ-VBS semivolatile POA treatment underpredicted AMS hydrocarbon-like OA (HOA) + cooking-influenced OA (CIOA) at Pasadena by a factor of 1.8 compared to a factor of 1.4 overprediction of POA in CMAQ-AE6, but it did capture the AMS diurnal profile of HOA and CIOA well, with the exception of the midday peak. Overall, the CMAQ-VBS with its semivolatile treatment of POA, SOA from intermediate volatility organic compounds (IVOCs), and aging of SOA improves SOA model performance (though SOA formation efficiency is still 1.6–2 × too low). However, continued efforts are needed to better understand assumptions in the parameterization (e.g., SOA aging) and provide additional certainty to how best to apply existing emission inventories in a framework that treats POA as semivolatile, which currently degrades existing model performance at routine monitoring networks. The VBS and other approaches (e.g., AE6) require additional work to appropriately incorporate IVOC emissions and subsequent SOA formation.