Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “network equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Energy Efficient Digital Networks

Digital networks are the foundation of the information services, and play an expanding and indispensable role in our lives, via the Internet, email, mobile phones, etc. However, these networks consume energy, both through the direct energy use of the network interfaces and equipment that comprise the network, and in the effect they have on the operating patterns of devices connected to the network. The purpose of this research was to investigate a variety of technology and policy issues related to the energy use caused by digital networks, and to further develop several energy-efficiency technologies targeted at networks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

Langley advanced real-time simulation (ARTS) system

A system of high-speed digital data networks was developed and installed to support real-time flight simulation at the NASA Langley Research Center. This system, unlike its predecessor, employs intelligence at each network node and uses distributed 10-V signal conversion equipment rather than centralized 100-V equipment. A network switch, which replaces an elaborate system of patch panels, allows the researcher to construct a customized network from the 25 available simulation sites by invoking a computer control statement. The intent of this paper is to provide a coherent functional description of the system. This development required many significant innovations to enhance performance and functionality such as the real-time clock, the network switch, and improvements to the CAMAC network to increase both distances to sites and data rates. The system has been successfully tested at a usable data rate of 24 M. The fiber optic lines allow distances of approximately 1.5 miles from switch to site. Unlike other local networks, CAMAC does not buffer data in blocks. Therefore, time delays in the network are kept below 10 microsec total. This system underwent months of testing and was put into full service in July 1987.

Crawford, Daniel J.↗

Second Line of Defense Master Spares Catalog

This catalog is intended to be a comprehensive listing of repair parts, components, kits, and consumable items used on the equipment deployed at SLD sites worldwide. The catalog covers detection, CAS, network, ancillary equipment, and tools. The catalog is backed by a Master Parts Database which is used to generate the standard report views of the catalog. The master parts database is a relational database containing a record for every part in the master parts catalog along with supporting tables for normalizing fields in the records. The database also includes supporting queries, database maintenance forms, and reports.

Henderson, Dale L.↗

A Fundamental Investigation on the Structural Dynamics of Model Siloxane Networks under Extreme Pressure

Poly(dimethylsiloxane) elastomers are ubiquitous in their application as key components in a range of (often extreme) environments. and as such, they often experience pressures in a region where we do not understand their physical response and therefore can offer no predictive estimate of lifetime of failure . We are proposing a fundamental scientific investigation of the pressure induced morphological changes in model PDMS networks. Both NMR and BDS spectroscopies will be used to interrogate pressure induced changes and meaningful phase relations will be sought. The addition of filler to the networks will be used as an attempt to engineer the network to be more resistant to pressure changes. We have the equipment, model networks and expertise to start this project immediately; funding is sought as an investment in our time allocation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transactional Network Platform: Applications

In FY13, Pacific Northwest National Laboratory (PNNL) with funding from the Department of Energy’s (DOE’s) Building Technologies Office (BTO) designed, prototyped and tested a transactional network platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). Initially, in FY13, the concept demonstrated transactions between packaged rooftop air conditioners and heat pump units (RTUs) and the electric grid using applications or "agents" that reside on the platform, on the equipment, on a local building controller or in the Cloud. The transactional network project is a multi-lab effort with Oakridge National Laboratory (ORNL) and Lawrence Berkeley National Laboratory (LBNL) also contributing to the effort. PNNL coordinated the project and also was responsible for the development of the transactional network (TN) platform and three different applications associated with RTUs. This document describes two applications or "agents" in details, and also summarizes the platform. The TN platform details are described in another companion document.

Katipamula, Srinivas↗

Assessing DER Network Cybersecurity Defences in a Power-Communication Co-Simulation Environment

Increasing penetrations of interoperable distributed energy resources (DER) in the electric power system are expanding the power system attack surface. Maloperation or malicious control of DER equipment can now cause substantial disturbances to grid operations. Fortunately, many options exist to defend and limit adversary impact on these newly-created DER communication networks, which typically traverse the public internet. However, implementing these security features will increase communication latency, thereby adversely impacting real-time DER grid support service effectiveness. In this work, a collection of software tools called SCEPTRE were used to create a co-simulation environment where SunSpec-compliant PV inverters were deployed as virtual machines and interconnected to simulated communication network equipment. Network segmentation, encryption, and moving target defence security features were deployed on the control network to evaluate their influence on cybersecurity metrics and power system performance. The results indicated that adding these security features did not impact DER-based grid control systems but improved the cybersecurity posture of the network when implemented appropriately.

97 MATHEMATICS AND COMPUTING↗

Electric vehicle supply equipment location and capacity allocation for fixed-route networks

Electric vehicle (EV) supply equipment location and allocation (EVSELCA) problems for freight vehicles are becoming more important because of the trending electrification shift. Some previous works address EV charger location and vehicle routing problems simultaneously by generating vehicle routes from scratch. Although such routes can be efficient, introducing new routes may violate practical constraints, such as drive schedules, and satisfying electrification requirements can require dramatically altering existing routes. To address the challenges in the prevailing adoption scheme, we approach the problem from a fixed -route perspective. We develop a mixed -integer linear program, a clustering approach, and a metaheuristic solution method using a genetic algorithm (GA) to solve the EVSELCA problem. The clustering approach simplifies the problem by grouping customers into clusters, while the GA generates solutions that are shown to be nearly optimal for small problem cases. A case study examines how charger costs, energy costs, the value of time (VOT), and battery capacity impact the cost of the EVSELCA. Charger equipment costs were found to be the most significant component in the objective function, leading to a substantial reduction in cost when decreased. VOT costs exhibited a significant decrease with rising energy costs. Further, an increase in VOT resulted in a notable rise in the number of fast chargers. Longer EV ranges decrease total costs up to a certain point, beyond which the decrease in total costs is negligible.

33 ADVANCED PROPULSION SYSTEMS↗

VOLTTRON Lite: Integration Platform for the Transactional Network

In FY13, Pacific Northwest National Laboratory (PNNL) with funding from the Department of Energy’s (DOE’s) Building Technologies Office (BTO) designed, prototyped and tested a transactional network platform. The platform is intended to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). Initially, in FY13, the concept demonstrated transactions between packaged rooftop units (RTUs) and the electric grid using applications or “agents” that reside on the platform, on the equipment, on local building controller or in the Cloud. This document describes the core of the transactional network platform, the Volttron Lite™ software and associated services hosted on the platform. Future enhancements are also discussed. The appendix of the document provides examples of how to use the various services hosted on the platform.

Haack, Jereme N.↗

How to Take 30 Years Off the Life of an Earth-Orbiter Network

In the mid 1960's the NASA/JPL Deep Space Network installed a global 26-meter antenna network to support a large group of Low Earth Orbiters and Highly Elliptical Orbiters. Although this network was equipped with then state-of-the-art equipment, operations were labor- intensive. A study is discussed which takes a close look at re- engineering the 26-meter antenna network from all aspects.

re-engineering evaluation deep space network↗

ISLE: Intelligent Selection of Loop Electronics. A CLIPS/C++/INGRES integrated application

The Intelligent Selection of Loop Electronics (ISLE) system is an integrated knowledge-based system that is used to configure, evaluate, and rank possible network carrier equipment known as Digital Loop Carrier (DLC), which will be used to meet the demands of forecasted telephone services. Determining the best carrier systems and carrier architectures, while minimizing the cost, meeting corporate policies and addressing area service demands, has become a formidable task. Network planners and engineers use the ISLE system to assist them in this task of selecting and configuring the appropriate loop electronics equipment for future telephone services. The ISLE application is an integrated system consisting of a knowledge base, implemented in CLIPS (a planner application), C++, and an object database created from existing INGRES database information. The embedibility, performance, and portability of CLIPS provided us with a tool with which to capture, clarify, and refine corporate knowledge and distribute this knowledge within a larger functional system to network planners and engineers throughout U S WEST.

Fischer, Lynn↗

Model-Based Sensor Placement for Component Condition Monitoring and Fault Diagnosis in Fossil Energy Systems

Design and operation of energy producing, near “zero-emission” coal plants has become a national imperative. This report on model-based sensor placement describes a transformative two-tier approach to identify the optimum placement, number, and type of sensors for condition monitoring and fault diagnosis in fossil energy system operations. The algorithms are tested on a high fidelity model of the integrated gasification combined cycle (IGCC) plant. For a condition monitoring network, whether equipment should be considered at a unit level or a systems level depends upon the criticality of the process equipment, its likeliness to fail, and the level of resolution desired for any specific failure. Because of the presence of a high fidelity model at the unit level, a sensor network can be designed to monitor the spatial profile of the states and estimate fault severity levels. In an IGCC plant, besides the gasifier, the sour water gas shift (WGS) reactor plays an important role. In view of this, condition monitoring of the sour WGS reactor is considered at the unit level, while a detailed plant-wide model of gasification island, including sour WGS reactor and the Selexol process, is considered for fault diagnosis at the system-level. Finally, the developed algorithms unify the two levels and identifies an optimal sensor network that maximizes the effectiveness of the overall system-level fault diagnosis and component-level condition monitoring. This work could have a major impact on the design and operation of future fossil energy plants, particularly at the grassroots level where the sensor network is yet to be identified. In addition, the same algorithms developed in this report can be further enhanced to be used in retrofits, where the objectives could be upgrade (addition of more sensors) and relocation of existing sensors.

20 FOSSIL-FUELED POWER PLANTS↗

Service Management Database for DSN Equipment

This data- and event-driven persistent storage system leverages the use of commercial software provided by Oracle for portability, ease of maintenance, scalability, and ease of integration with embedded, client-server, and multi-tiered applications. In this role, the Service Management Database (SMDB) is a key component of the overall end-to-end process involved in the scheduling, preparation, and configuration of the Deep Space Network (DSN) equipment needed to perform the various telecommunication services the DSN provides to its customers worldwide. SMDB makes efficient use of triggers, stored procedures, queuing functions, e-mail capabilities, data management, and Java integration features provided by the Oracle relational database management system. SMDB uses a third normal form schema design that allows for simple data maintenance procedures and thin layers of integration with client applications. The software provides an integrated event logging system with ability to publish events to a JMS messaging system for synchronous and asynchronous delivery to subscribed applications. It provides a structured classification of events and application-level messages stored in database tables that are accessible by monitoring applications for real-time monitoring or for troubleshooting and analysis over historical archives.

Zendejas, Silvino↗

A Scalable Quantum Cryptography Network for Protected Automation Communication (Final Report)

This is the final report for a CEDS-funded project aimed at developing a new quantum technology for securing utility communication networks used to control and monitor electrical grid equipment. Securing these control networks represents a unique challenge as the performance of the security solution has a direct impact on the stability and reliability of the electrical grid. Traditional, software-based solutions - developed for information networks - are not suitable for utility control networks because they introduce latency, require burdensome maintenance and upgrades, are often incompatible with legacy equipment, and introduce operational complexity that reduces grid reliability. Consequently, many U.S. utilities do not use existing solutions and, instead, protect their critical control networks through the careful isolation and obscuration of their networked equipment. With more utilities embracing grid automation, the attack surface that utilities must defend from hackers has grown to an unmanageable size. To address this situation, Qubitekk and its partners proposed and developed a hardware-based solution that can secure critical control networks without negatively impacting grid performance. This new solution is based on quantum key distribution (QKD) techniques that guarantee secure key generation and distribution across a utility control network. Through deployment and field testing of a prototype QKD system, we have shown that this solution delivers long-term network security, is technically feasible to implement and maintain on a utility’s distribution substation network and does not negatively impact grid operations. In addition, the project has identified and solved key challenges associated with generating, transmitting, and measuring coherent photonic quantum states on a real-world fiber optic network. These additional findings are playing a critical role in advancing quantum networks for quantum computing applications. An overview of the QKD prototype development effort, field testing activities and results, and additional findings relevant to emerging quantum networks are presented in this report.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topological Machine Learning Methods for Power System Responses to Contingencies: Preprint

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remain untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topologybased system that depends on neural network architecture for impact metrics classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, namely, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates both more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn complex relationships between electrical properties and local topological measurements on the simulated response to contingencies for NREL-SIIP power system.

graph theory↗

Topological Machine Learning Methods for Power System Responses to Contingencies

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remains untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topology-based system that depends on a neural network architecture for impact metric classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn more about the complex relationships between electrical properties and local topological measurements on their simulated response to contingencies for the NREL-SIIP power system.

contingency analysis↗