Near-field passive sensor for the monitoring of high-temperature oxidative corrosion of metals

This study reports on the development and testing of a passive wireless device designed to track temperature and corrosion behavior in SS304H stainless steel under elevated temperatures. The ANSYS HFSS software was utilized to model and optimize the design of an inductor-capacitor (LC) resonator passive wireless sensors fabricated using platinum designs printed onto an aluminum oxide support operating at frequencies between (50–190 MHz). The optimal LC wireless sensor designs were then fabricated using screen-printing and sintering methods. Here, the sensors were tested by placing the sensor onto polished SS304H flat substrates and heated to 900–1050 °C in air. Wireless acquisition of sensor data during heating, cooling, and isothermal stages was achieved through a Pt loop antenna connected to an RF signal generator and a network analyzer.

20 FOSSIL-FUELED POWER PLANTS↗

Material Characterization Study of Magnetite Nanocrystals for RF Sensing

Magnetite nanocrystals show promise for electrically small gigahertz frequency applications, which could lead to miniaturizing transformer cores and new sensing technologies. This work presents a rigorous radiofrequency characterization of these nanocrystals using vector network analyzer (VNA) ferromagnetic resonance (FMR) measurements. For the first time, two different average diameters of Fe 3 O 4 nanocrystals are investigated (7.3 and 20.2 nm). When the VNA–FMR results were compared to micromagnetic simulations, the magnetic anisotropy (K 1 ) deviated from the ideal mean orientation value of K 1 /2 to K 1 /80 for the 7.3 nm nanocrystal. In contrast, the obtained magnetic anisotropy in 20.2 nm nanocrystals slightly deviated to K 1 /11 due to less structural deformations. These findings resulted in a newly proposed methodology for an approximate simulation based on VNA–FMR measurements. In addition, this work estimates the approximate amount of nanocrystals needed to measure a useful VNA–FMR spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Cryogenic single-port calibration for superconducting microwave resonator measurements

Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. Additionally, a common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Effects of the Local Environment on a Compact Radio Interferometer I: Cross-Coupling in the Tianlai Dish Pathfinder Array

The visibilities measured by radio astronomical interferometers include non-astronomical correlated signals that arise from the local environment of the array. These correlated signals are especially important in compact arrays such as those under development for 21cm intensity mapping. The amplitudes of the contaminated visibilities can exceed the expected 21cm signal and represent a significant systematic effect. We study the receiver noise radiated by antennas in compact arrays and develop a model for how it couples to other antennas. We apply the model to the Tianlai Dish Pathfinder Array (TDPA), a compact array of 16, 6-m dish antennas. The coupling model includes electromagnetic simulations, measurements with a network analyzer, and measurements of the noise of the receivers. We compare the model to drift-scan observations with the array and set requirements on the level of antenna cross-coupling for 21cm intensity mapping instruments. Here, we find that for the TDPA, cross-coupling would have to be reduced by three orders of magnitude in order to contribute negligibly to the visibilities.

21cm intensity mapping↗

gait

SAND2022-6991 O gait is an extension to zeek, an open-source network analyzer that adds metadata to the existing connection and SSL logs. Most of this metadata is already exposed by the zeek script API. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Smutz, Charles↗

Review of Intrusion Detection Methods and Tools for Distributed Energy Resources

Recent trends in the growth of distributed energy resources (DER) in the electric grid and newfound malware frameworks that target internet of things (IoT) devices is driving an urgent need for more reliable and effective methods for intrusion detection and prevention. Cybersecurity intrusion detection systems (IDSs) are responsible for detecting threats by monitoring and analyzing network data, which can originate either from networking equipment or end-devices. Creating intrusion detection systems for PV/DER networks is a challenging undertaking because of the diversity of the attack types and intermittency and variability in the data. Distinguishing malicious events from other sources of anomalies or system faults is particularly difficult. New approaches are needed that not only sense anomalies in the power system but also determine causational factors for the detected events. In this report, a range of IDS approaches were summarized along with their pros and cons. Using the review of IDS approaches and subsequent gap analysis for application to DER systems, a preliminary hybrid IDS approach to protect PV/DER communications is formed in the conclusion of this report to inform ongoing and future research regarding the cybersecurity and resilience enhancement of DER systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Apex Study: Compensating Transient Beam Loading in the RHIC 28 MHZ

With the EIC on the way, it is important that developments and strategies are in place to deal with the very high beam currents that the machine will feature. Specifically, the EIC will collide beams of up to 2.5 A, three times the beam current in RHIC. This higher beam current will cause significant voltage transients in the cavity fields which can lead to longitudinal instabilities and beam loss. In anticipation of these negative effects, studies were carried out on the RHIC 28 MHz cavities using newly developed firmware and software to diagnose and combat beam loading. Diagnostic tools such as the bunch-by-bunch (BbyB) ADC firmware and digital network analyzer (DNA) were used to characterize the closed loop system and transient on the cavity voltage magnitude and phase. Then, a one-turn delay feedback (OTFB) and adaptive feed-forward (aFFWD) were used to minimize the transient beam loading. The studies were carried out with beam during 2 accelerator physics experiements (APEXs) using one of the 28 MHz accelerating cavities here at RHIC.

43 PARTICLE ACCELERATORS↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators on silicon that sense bursts of energy through tiny shifts in their resonance. In this work, we installed new devices in the QUIET facility's cryogenic test setup and used a network analyzer to drive them across a range of power levels. At each setting, we measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. And despite the increased noise at low power, our model consistently captured the resonance behavior. We observed that the resonant frequency stayed stable across most powers, the device s internal quality factor improved with stronger signals, and its coupling strength peaked mid‑range before leveling off. Overall, these findings confirm the detector s performance, laying groundwork for future work on energy calibration with pulsed optical sources.

Savitala, Akash [Washington U., Seattle; Fermilab]↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Leveraging History to Predict Infrequent Abnormal Transfers in Distributed Workflows

Scientific computing heavily relies on data shared by the community, especially in distributed data-intensive applications. This research focuses on predicting slow connections that create bottlenecks in distributed workflows. In this study, we analyze network traffic logs collected between January 2021 and August 2022 at the National Energy Research Scientific Computing Center (NERSC). Based on the observed patterns, we define a set of features primarily based on history for identifying low-performing data transfers. Typically, there are far fewer slow connections on well-maintained networks, which creates difficulty in learning to identify these abnormally slow connections from the normal ones. We devise several stratified sampling techniques to address the class-imbalance challenge and study how they affect the machine learning approaches. Our tests show that a relatively simple technique that undersamples the normal cases to balance the number of samples in two classes (normal and slow) is very effective for model training. This model predicts slow connections with an F1 score of 0.926.

97 MATHEMATICS AND COMPUTING↗

Grating Polarizers at 170 GHz for ECRH Systems: Low Power Tests and Simulations

The elliptical polarization produced by a pair of sinusoidally profiled miter-bend grating polarizers has been measured experimentally and found to be in excellent agreement with theory. The polarizers were designed to be used at 170 GHz in the miter bends of a 63.5 mm corrugated metallic waveguide for creating the arbitrary elliptically polarized microwave beam needed for electron cyclotron resonance heating of plasma. Using a vector network analyzer to generate a linearly polarized HE11 incident mode, each polarizer was individually tested to measure the rotation α and ellipticity β of the elliptically polarized reflected microwave beam as a function of the grating rotation angle. The grating polarizers were then tested together to measure the elliptical polarization as a function of the angles of the combination of the two polarizers arranged sequentially on the transmission line. The map of the ellipticity versus grating angles agreed very well with numerical simulations using high-frequency structure simulator. Numerical simulations show that up to eight combinations of rotation angles of the two grating polarizers can provide the same ellipticity but with the varying ohmic loss, thus allowing the choice of settings to minimize the ohmic loss, a necessary consideration to minimize heating effects in megawatt power level systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of solid-propellant transient regression rates using a microwave Doppler shift technique

A microwave Doppler shift system, with increased resolution over earlier microwave techniques, was developed for the purpose of measuring the regression rates of solid propellants during rapid pressure transients. A continuous microwave beam is transmitted to the base of a burning propellant sample cast in a metal waveguide tube. A portion of the wave is reflected from the regressing propellant-flame zone interface. The phase angle difference between the incident and reflected signals and its time differential are continuously measured using a high resolution microwave network analyzer and related instrumentation. The apparent propellant regression rate is directly proportional to this latter differential measurement. Experiments were conducted to verify the (1) spatial and time resolution of the system, (2) effect of propellant surface irregularities and compressibility on the measurements, and (3) accuracy of the system for quasi-steady-state regression rate measurements. The microwave system was also used in two different transient combustion experiments: in a rapid depressurization bomb, and in the high-frequency acoustic pressure environment of a T-burner.

Strand, L. D.↗

Snow Electromagnetic Measurements

An electromagnetic system is described for measuring the dielectric constant and attenuation of snow samples in the frequency range of 4 to 12 GHz. System components consists of a swept-frequency source, microwave horns, network analyzer, and XY plotter. The procedure for calibrating the effect of wetness on the snow properties is described. Equations are given that express the experimentally determined relation between attenuation per unit length and volume percent wetness at any frequency between 4 and 12 GHz. permittivity can be calculated from the snow density, attenuation per unit length, and frequency. Some applications of the techniques are described such as runoff forecasting from mountain snowpacks.

Linlor, W. I.↗

Microstrip termination effects on dielectric resonator filters

Dielectric resonator filters coupled to microstrip lines appear to answer the requirements of high performance and small size and weight that must be satisfied for use in satellite-based radiometers. The open-circuit and short-circuit types of coupling dielectric resonators to microstrip lines were compared with respect to radiation losses at various frequencies. The filters were fabricated from 1.6 mm Duroid board. The termination impedances for the microstrip lines were measured using a calibrated HP 8510 network analyzer. The values for radiation resistance obtained experimentally for both types of coupling agreed well with the values calculated from the Lewin theory (1960). It was found that the use of short-circuit coupling results in significantly reduced radiation resistance compared to the use of open-circuit lines. Improvement increases with increased frequency.

Trew, R. J.↗