Engineering PapersSearch

SEARCH · Engineering Papers

Results for “nanometer resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Clementine High Resolution Camera Mosaicking Project: CL 6020; 80 deg N to 90 deg N Latitude, South Periapsis - Volume 20

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael

Clementine High Resolution Camera Mosaicking Project: CL 6021; 80 deg S to 90 deg S Latitude, North Periapsis - Volume 21

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael

Clementine High Resolution Camera Mosaicking Project: CL 6019; 80 deg N to 90 deg N Latitude, North Periapsis - Volume 19

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael

Estimating Coastal Turbidity using MODIS 250 m Band Observations

Terra MODIS 250 m observations are being applied to a Suspended Sediment Concentration (SSC) algorithm that is under development for coastal case 2 waters where reflectance is dominated by sediment entrained in major fluvial outflows. An atmospheric correction based on MODIS observations in the 500 m resolution 1.6 and 2.1 micron bands is used to isolate the remote sensing reflectance in the MODIS 25Om resolution 650 and 865 nanometer bands. SSC estimates from remote sensing reflectance are based on accepted inherent optical properties of sediment types known to be prevalent in the U.S. Gulf of Mexico coastal zone. We present our findings for the Atchafalaya Bay region of the Louisiana Coast, in the form of processed imagery over the annual cycle. We also apply our algorithm to selected sites worldwide with a goal of extending the utility of our approach to the global direct broadcast community.

Davies, James E.

Development of a Fast and Accurate PCRTM Radiative Transfer Model in the Solar Spectral Region

A fast and accurate principal component-based radiative transfer model in the solar spectral region (PCRTMSOLAR) has been developed. The algorithm is capable of simulating reflected solar spectra in both clear sky and cloudy atmospheric conditions. Multiple scattering of the solar beam by the multilayer clouds and aerosols are calculated using a discrete ordinate radiative transfer scheme. The PCRTM-SOLAR model can be trained to simulate top-of-atmosphere radiance or reflectance spectra with spectral resolution ranging from 1 cm(exp −1) resolution to a few nanometers. Broadband radiances or reflectance can also be calculated if desired. The current version of the PCRTM-SOLAR covers a spectral range from 300 to 2500 nm. The model is valid for solar zenith angles ranging from 0 to 80 deg, the instrument view zenith angles ranging from 0 to 70 deg, and the relative azimuthal angles ranging from 0 to 360 deg. Depending on the number of spectral channels, the speed of the current version of PCRTM-SOLAR is a few hundred to over one thousand times faster than the medium speed correlated-k option MODTRAN5. The absolute RMS error in channel radiance is smaller than 10(exp −3) mW∕cm)exp 2)∕sr∕cm(exp −1) and the relative error is typically less than 0.2%.

Liu, Xu

High-resolution absorption cross section measurements of carbon monoxide at 20 K between 96.7 and 98.8 nanometers

Photoabsorption cross sections for five CO bands, at wavelengths between 96.7 and 98.8 nm, have been measured at high-resolution in a supersonic jet-cooled source at the Photon Factory synchrotron facility. New integrated cross sections are reported for the K-X, L(prime)-X, and L-X bands. Low-temperature spectra of the J-X and W-X bands, which were used in the determination of the absorbing CO column densities, are also presented. The rotational structures of the K-X, L(prime)-X, and L-X bands do not overlap in the low-temperature spectra, allowing for the first unambiguous determination of these band oscillator strengths. We also report revised room temperature measurements of integrated cross sections for the K-X, L(prime)-X, and L-X bands, in which distortions in the measured spectra due to insufficient instrumental resolution have been minimized; the revised room temperature integrated cross sections are consistent with the low-temperature results.

Stark, G.

High-resolution absorption cross sections of carbon monoxide bands at 295 K between 91.7 and 100.4 nanometers

Theoretical descriptions of the abundance and excitation of carbon monoxide in interstellar clouds require accurate data on the vacuum-ultraviolet absorption spectrum of the molecule. The 6.65 m spectrometer at the Photon Factory synchrotron light source was used to measure photoabsorption cross sections of CO features between 91.2 and 100.4 nm. These data were recorded at a resolving power of 170,000, more than 20 times greater than that used in previous work.

Stark, G.

Fe and O EELS Studies of Ion Irradiated Murchison CM2 Carbonaceous Chondrite Matrix

Introduction: The physical and chemical response of hydrated carbonaceous chondrite materials to space weathering processes is poorly understood. Improving this understanding is a key part of establishing how regoliths on primitive carbonaceous asteroids respond to space weathering processes, knowledge that supports future sample return missions (Hayabusa 2 and OSIRISREx) that are targeting objects of this type. We previously reported on He+ irradiation of Murchison matrix and showed that the irradiation resulted in amorphization of the matrix phyllosilicates, loss of OH, and surface vesiculation. Here, we report electron energy-loss spectroscopy (EELS) measurements of the irradiated material with emphasis on the Fe and O speciation. Sample and Methods: A polished thin section of the Murchison CM2 carbonaceous chondrite was irradiated with 4 kilovolts He(+) (normal incidence) to a total dose of 1 x 10(exp 18) He(+) per square centimeter. We extracted thin sections from both irradiated and unirradiated regions in matrix using focused ion beam (FIB) techniques with electron beam deposition for the protective carbon strap to minimize surface damage artifacts from the FIB milling. The FIB sections were analyzed using a JEOL 2500SE scanning and transmission electron microscope (STEM) equipped with a Gatan Tridiem imaging filter. EELS spectra were collected from 50 nanometer diameter regions with an energy resolution of 0.7 electronvolts FWHM at the zero loss. EELS spectra were collected at low electron doses to minimize possible artifacts from electron-beam irradiation damage. Results and Discussion: Fe L (sub 2,3) EELS spectra from matrix phyllosilicates in CM chondrites show mixed Fe(2+)/Fe(3+) oxidation states with Fe(3+)/Sigma Fe approximately 0.5. Fe L(sub 2,3) spectra from the irradiated/ amorphized matrix phyllosilicates show higher Fe(2+)/Fe(3+) ratios compared to spectra obtained from pristine material at depths beyond the implantation/amorphization layer. We also obtained O Ka spectra from phyllosilicates in both regions of the sample. The O Ka spectra show a pre-edge feature at approximately 530.5 electronvolts that is related to O 2p states hybridized with Fe 3d states. The intensity ratio of the O Ka pre-edge peak relative to the main part of the O Ka edge (that results from transitions of O 1s to 2p states) is lower in the irradiated layer compared to the pristine material and may reflect the loss of O (as OH) as was observed by IR spectroscopy. Conclusions: In addition to amorphization and OH loss, EELS spectra of He(+) irradiated matrix phyllosilicates in Murchison show that some of the Fe(3+) is reduced to Fe(2+). Spectral deconvolution is underway to extract quantitative ratios from the EELS spectra.

Keller, L. P.

High resolution cloud feature tracking on Venus by Galileo

The Venus cloud deck was monitored in February 1990 for 16 hours at 400 nanometers wavelength by the Galileo imaging system, with a spatial resolution of about 15 km and with image time separations as small as 10 minutes. Velocities are deduced by following the motion of small cloud features. In spite of the high temporal frequence is capable of being detected, no dynamical phenomena are apparent in the velocity data except the already well-known solar tides, possibly altered by the slow 4-day wave and the Hadley circulation. There is no evidence, to a level of approximately 4 m/s, of eddy or wavelike activity. The dominant size of sub-global scale albedo features is 200-500 km, and their contrast is approximately 5%. At low altitudes there are patches of blotchy, cell-like structures but at most locations the markings are streaky. The patterns are similar to those discovered by Mariner 10 and Pioneer Venus (M. J. S. Belton et al., 1976, W. B. Rossow et al., 1980). Scaling arguments are presented to argue that the mesoscale blotchy cell-like cloud patterns are caused by local dynamics driven in a shallow layer by differential absorption of sunlight. It is also argued that mesoscale albedo features are either streaky or cell-like simply depending on whether the horizontal shear of the large scale flow exceeds a certain critical value.

Toigo, Anthony

TPSAS-NF1676L-31770-DND

HREBSD (high resolution electron backscatter diffraction) is a scanning electron microscope based diffraction technique that measures stress, elastic strain and dislocation density in crystalline materials with a spatial resolution on the order of tens of nanometers. This information represents a glut of quantitative data that may be directly incorporated in microscale crystal plasticity models. However, concerns over the accuracy of HREBSD make integration of microscopy data with material models problematic. This presentation addresses a number of issue concerning the accuracy of HREBSD, including pattern center error, cross-correlation error and random noise. Additionally, a computational framework is presented that allows for rapid, non-deterministic calibration of material models. Finally, several tests cases are presented where HREBSD is cross-validated with other diffraction techniques: X-ray diffraction, electron channeling contrast imaging and transmission electron microscopy. The accuracy of HREBSD, when incorporating these new techniques, is sufficient to measure local stress to below 10 MPa and to detect individual dislocations.

Timothy J Ruggles

An imaging spectrometer experiment for the Shuttle

An imaging spectrometer experiment concept for earth remote sensing, developed as part of NASA's Multispectral Linear Array program, will map a series of test sites at high spatial and spectral resolution from the vantage point of the Shuttle payload bay. The instrument covers the spectral range from 0.4 to 2.5 micrometers with a sampling interval of 10 nanometers in the visible and near infrared (to 1.0 micrometer) and 20 nanometers in the short wavelength infrared (1.0 to 2.5 micrometers). Resolution corresponding to a ground instantaneous field of view (pixel size) of 30 meters is provided over a swath width of 12 kilometers. On-board data editing is utilized to select a subset of the data stream for transmission to the ground. The instrument utilizes silicon and mercury cadmium telluride area array detectors. Pointing mirrors are included to permit specific test sites to be imaged from the Shuttle orbit.

Wellman, J. B.

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors

Nanoscale Hot-Wire Probes for Boundary-Layer Flows

Hot-wire probes having dimensions of the order of nanometers have been proposed for measuring temperatures (and possibly velocities) in boundary-layer flows at spatial resolutions much finer and distances from walls much smaller than have been possible heretofore. The achievable resolutions and minimum distances are expected to be of the order of tens of nanometers much less than a typical mean free path of a molecule and much less than the thickness of a typical flow boundary layer in air at standard temperature and pressure. An additional benefit of the small scale of these probes is that they would perturb the measured flows less than do larger probes. The hot-wire components of the probes would likely be made from semiconducting carbon nanotubes or ropes of such nanotubes. According to one design concept, a probe would comprise a single nanotube or rope of nanotubes laid out on the surface of an insulating substrate between two metallic wires. According to another design concept, a nanotube or rope of nanotubes would be electrically connected and held a short distance away from the substrate surface by stringing it between two metal electrodes. According to a third concept, a semiconducting nanotube or rope of nanotubes would be strung between the tips of two protruding electrodes made of fully conducting nanotubes or ropes of nanotubes. The figure depicts an array of such probes that could be used to gather data at several distances from a wall. It will be necessary to develop techniques for fabricating the probes. It will also be necessary to determine whether the probes will be strong enough to withstand the aerodynamic forces and impacts of micron-sized particles entrained in typical flows of interest.

Tedjojuwono, Ken T.

New AFM Techniques for Investigating Molecular Growth Mechanisms of Protein Crystals

Atomic Force Microscopy (AFM) has emerged as a powerful technique for investigating protein crystal growth. Earlier AFM studies were among the first to demonstrate that these crystals grew by dislocation and 2D nucleation growth mechanisms [1]. These investigations were restricted to the micron range where only surface features, such as dislocation hillocks and 2D islands are visible. Most AFM instruments can scan at higher resolutions and have the potential to resolve individual protein molecules at nanometer ranges. Such scans are essential for determining the molecular packing arrangements on crystal faces and for probing the growth process at the molecular level. However, at this resolution the AFM tip influences the image produced, with the resulting image being a convolution of the tip shape and the surface morphology [2]. In most studies this problem is resolved by deconvoluting the image to obtain the true surface morphology. Although deconvolution routines work reasonably well for simple one- dimensional shapes, for complex surfaces this approach does not produce accurate results. In this study we devised a new approach which takes advantage of the precise molecular order of crystal surfaces, combined with the knowledge of individual molecular shapes from the crystallographic data of the protein and the AFM tip shape. This information is used to construct expected theoretical AFM images by convoluting the tip shape with the constructed crystal surface shape for a given surface packing arrangement. By comparing the images from actual AFM scans with the constructed ones for different possible surface packing arrangements, the correct packing arrangement can be conclusively determined. This approach was used in this study to determine the correct one from two possible packing arrangements on (I 10) faces of tetragonal lysozyme crystals. Another novel AFM technique was also devised to measure the dimension of individual growth units of the crystal faces. Measuring these units was not attempted before and most studies have assumed that the growth unit consisted of individual protein molecules. The linescan mode of AFM instruments allows the crystal surface to be scanned along a single line. By scanning across a growth step an image showing the motion of the step is obtained. Normally such an image shows a straight line for continuous and constant step velocity. In this study by increasing the scan rate and by decreasing the step velocity (by decreasing the supersaturation), we were able to capture images of individual growth events, shown by jump discontinuities in the step line. By suitable integration of the image the growth unit dimension in the scanned direction can be obtained. Since multiple units can be involved in the growth process it is necessary to collect a statistically relevant sample before drawing conclusions about the growth mechanism. This technique was successfully employed to obtain the dimensions of growth units for the (110) face, showing that they consisted of various aggregates corresponding to the 43 helices in the crystal structure.

Li, Huayu

Improved Process for Fabricating Carbon Nanotube Probes

An improved process has been developed for the efficient fabrication of carbon nanotube probes for use in atomic-force microscopes (AFMs) and nanomanipulators. Relative to prior nanotube tip production processes, this process offers advantages in alignment of the nanotube on the cantilever and stability of the nanotube's attachment. A procedure has also been developed at Ames that effectively sharpens the multiwalled nanotube, which improves the resolution of the multiwalled nanotube probes and, combined with the greater stability of multiwalled nanotube probes, increases the effective resolution of these probes, making them comparable in resolution to single-walled carbon nanotube probes. The robust attachment derived from this improved fabrication method and the natural strength and resiliency of the nanotube itself produces an AFM probe with an extremely long imaging lifetime. In a longevity test, a nanotube tip imaged a silicon nitride surface for 15 hours without measurable loss of resolution. In contrast, the resolution of conventional silicon probes noticeably begins to degrade within minutes. These carbon nanotube probes have many possible applications in the semiconductor industry, particularly as devices are approaching the nanometer scale and new atomic layer deposition techniques necessitate a higher resolution characterization technique. Previously at Ames, the use of nanotube probes has been demonstrated for imaging photoresist patterns with high aspect ratio. In addition, these tips have been used to analyze Mars simulant dust grains, extremophile protein crystals, and DNA structure.

Stevens, R.

Photosynthetic Efficiency of Northern Forest Ecosystems Using a MODIS-Derived Photochemical Reflectance Index (PRI)

This study evaluates a direct remote sensing approach from space for the determination of ecosystem photosynthetic light use efficiency (LUE), through measurement of vegetation reflectance changes expressed with the Photochemical Reflectance Index (PRI). The PRI is a normalized difference index based on spectral changes at a physiologically active wavelength (approximately 531 nanometers) as compared to a reference waveband, and is only available from a very few satellites. These include the two Moderate-Resolution Imaging Spectroradiometers (MODIS) on the Aqua and Terra satellites each of which have a narrow (10-nanometer) ocean band centered at 531 nanometers. We examined several PRI variations computed with candidate reference bands, since MODIS lacks the traditional 570-nanometer reference band. The PRI computed using MODIS land band 1 (620-670 nanometers) gave the best performance for daily LUE estimation. Through rigorous statistical analyses over a large image collection (n equals 420), the success of relating in situ daily tower-derived LUE to MODIS observations for northern forests was strongly influenced by satellite viewing geometry. LUE was calculated from CO2 fluxes (moles per moles of carbon absorbed quanta) measured at instrumented Canadian Carbon Program flux towers in four Canadian forests: a mature fir site in British Columbia, mature aspen and black spruce sites in Saskatchewan, and a mixed deciduous/coniferous forest site in Ontario. All aspects of the viewing geometry had significant effects on the MODIS-PRI, including the view zenith angle (VZA), the view azimuth angle, and the displacement of the view azimuth relative to the solar principal plane, in addition to illumination related variables.Nevertheless, we show that forward scatter sector views (VZA, 16 degrees-45 degrees) provided the strongest relationships to daily LUE, especially those collected in the early afternoon by Aqua (r squared = 0.83, RMSE (root mean square error) equals 0.003 moles per moles of carbon absorbed quanta). Nadir (VZA, 0 degrees plus or minus 15 degrees) and backscatter views (VZA, −16 degrees to −45 degrees) had lower performance in estimating LUE (nadir: r squared approximately equal to 0.62-0.67; backscatter: r squared approximately equal to 0.54-0.59) and similar estimation error (RMSE equals 0.004-0.005).When directional effects were not considered, only a moderately successful MODIS-PRI vs. LUE relationship (r squared equals 0.34, RMSE equals 0.007) was obtained in the full dataset (all views & sites, both satellites), but site-specific relationships were able to discriminate between coniferous and deciduous forests. Overall, MODIS-PRI values from Terra (late morning) were higher than those from Aqua (early afternoon), before/after the onset of diurnal stress responses expressed spectrally. Therefore, we identified ninety-two Terra-Aqua "same day" pairs, for which the sum of Terra morning and Aqua afternoon MODIS-PRI values (PRI (sub sum) using all available directional observations was linearly correlated with daily tower LUE (r squared equals 0.622, RMSE equals 0.013) and independent of site differences or meteorological information. Our study highlights the value of off-nadir directional reflectance observations, and the value of pairing morning and afternoon satellite observations to monitor stress responses that inhibit carbon uptake in Canadian forest ecosystems. In addition, we show that MODIS-PRI values, when derived from either: (i) forward views only, or (ii) Terra/Aqua same day (any view) combined observations, provided more accurate estimates of tower-measured daily LUE than those derived from either nadir or backscatter views or those calculated by the widely used semi-operational MODIS GPP model (MOD17) which is based on a theoretical maximum LUE and environmental data. Consequently, we demonstrate the importance of diurnal as well as off-nadir satellite observations for detecting vegetation physiological processes.

Middleton, E. M.

ST7 Disturbance Reduction System (DRS) Colloid Micronewton Thruster Performance and Control Algorithm Model Simulation Validation in Flight

Colloid Micronewton Thrusters (CMNT) were flight demonstrated for the first time on the ST7Disturbance Reduction System (DRS) payload on the European Space Agency (ESA) Laser Interferometer Space Antenna (LISA) Pathfinder spacecraft for attitude and drag-free spacecraft control. LISA Pathfinder was a technology demonstration mission for ESA’s LISA gravitational wave observatory, currently in Phase A with a launch date of 2034. The DRS included the Integrated Avionics Unit (IAU), eight Colloid Micronewton Thrusters (CMNT), Dynamic Control Software (DCS) and Flight Software (FSW). The CMNT technology met performance requirements operating at 5-30 µN of thrust with ≤0.1 µN resolution and ≤0.1 µN/Hz thrust noise to deliver the required nanometer-level precision spacecraft control measured by the gravitational reference sensor (GRS) in the ESA LISA Technology Package (LTP). The performance of seven of the CMNT in flight was consistent with ground test results. The colloid thruster performance model of thrust and thrust noise as a function of operational parameters (i.e. beam current, voltage, temperature, etc.) was validated in flight over a wide range of conditions. A model and simulation of the thruster control algorithm was developed and validated with flight data to predict thrust noise. This capability is important because it is considered to be a significant source of position noise on the spacecraft and, therefore, the acceleration noise on the test masses, which provide the gravity wave measurements. The CMNT thruster model data and validation with LISA Pathfinder/ST7-DRS flight experiments are discussed in this paper.

Hruby, Vlad

In-Flight Verification and Validation of Colloid Microthruster Performance

Colloid Micronewton Thrusters (CMNTs) use an electrospray to provide precision spacecraft position and pointing control. They were demonstrated in space for the first time as part of NASA’s Space Technology 7 (ST7) payload hosted by the European Space Agency’s (ESA’s) LISA Pathfinder (LPF) technology demonstration mission in January, 2016. CMNTs were the actuator in the disturbance reduction system (DRS) that provided drag-free operation of the LPF spacecraft, which will be necessary for future gravity wave observatories such as ESA’s Laser Interferometer Space Antenna (LISA) mission, currently in Phase A and scheduled for launch in 2034. The CMNT technology met performance requirements operating at 5-30 µN of thrust with 0.1 µN resolution and ≤0.1 µN/ÖHz thrust noise to deliver the required nanometer-level precision spacecraft control measured by the gravitational reference sensor (GRS) in the ESA LISA Technology Package (LTP). The performance of seven of the eight CMNTs in flight was consistent with ground test results, and as a system, all eight thrusters met mission-level performance requirements. The colloid microthruster performance model of thrust and thrust noise as a function of operational parameters (i.e. beam current, voltage, temperature, etc.) was validated in flight over a wide range of conditions. A model and simulation of the thruster control algorithm was developed and validated with flight data to predict thrust noise. This capability is important for future missions because it relates directly to the acceleration noise on the test masses, which provide the gravity wave measurements. The CMNT thruster model data and validation with LISA Pathfinder/ST7-DRS flight experiments are presented in this paper.

"O'Donnell, James"