Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiwire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

The UH-nuclei cosmic ray detector on the third High Energy Astronomy Observatory

The third High Energy Astronomy Observatory satellite (HEAO-3) carries a particle telescope for the detection of highly charged cosmic ray nuclei. These nuclei, which have Z equal to or greater than 28, are much rarer than the lower charged nuclei in the cosmic radiation. As a consequence, this particle telescope was required to have a large collecting area as well as an ability to resolve individual elements. This paper describes the telescope, composed of large area parallel plate ionization chambers, multiwire ion chamber hodoscopes and a Cherenkov radiation detector. The resulting telescope has a total geometry factor of 59,000 sq cm sr and is capable of measuring the charges of nuclei in the range Z = 14-120.

Binns, W. R.↗

Field experience with various slicing methods

Wafer slicing using internal diameter (ID) saw, multiblade slurry (MBS) saw and multiwire slurry (MWS) saw techniques were evaluated. Wafer parameters such as bow, taper, and roughness which may not be important factors for solar cell fabrication, were considerably better for ID saw than those of the MBS and MWS saw. Analysis of add-on slicing cost indicated that machine productivity seems to be a major limiting factor for ID saw, while expendible material costs are a major factor for both MBS and MWS saw. Slicing experience indicated that the most important factors controling final wafer cost are: (1) silicon cost (wafer thickness + kerf loss); (2) add-on slicing cost, and (3) mechanical yield. There is a very strong interaction between these parameters, suggesting a necessity of optimization of these parameters.

Yoo, H. I.↗

An imaging gas scintillation proportional counter for the detection of subkiloelectron-volt X-rays

A large area imaging gas scintillation proportional counter (IGSPC) was constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counted (GSPC) with a micron polyprotylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. Over a sensitive area of 21 cu cm the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

A new transition radiation detector for cosmic ray nuclei

Test measurements on materials for transition radiation detectors at a low Lorentz factor are reported. The materials will be based on board Spacelab-2 for determining the composition and energy spectra of nuclear cosmic rays in the 1 TeV/nucleon range. The transition radiation detectors consist of a sandwich of radiator-photon detector combinations. The radiators emit X-rays and are composed of polyolefin fibers used with Xe filled multiwired proportional chamber (MWPC) detectors capable of detecting particle Lorentz factors of several hundred. The sizing of the detectors is outlined, noting the requirement of a thickness which provides a maximum ratio of transition radiation to total signal in the chambers. The fiber radiator-MWPC responses were tested at Fermilab and in an electron cyclotron. An increase in transition radiation detection was found as a square power law of Z, and the use of six radiator-MWPC on board the Spacelab-2 is outlined.

Lheureux, J.↗

Progress toward goals in silicon sheet development

One of the goals of the national photovoltaic program in the U.S. is the establishment of an industry producing photovoltaic material which can be sold at a price not exceeding $0.70/W by 1986. A key element concerning the achievement of this goal is the development and utilization of improved methods for producing silicon sheet. Specific technologies being investigated in this connection can be divided into two categories. Methods of one category are based on a utilization of sheet growth techniques including film-fed growth, dendritic web, and silicon-on-ceramic processes. The approaches used by methods of the second category involve ingot and wafering processes, including Czochralski growth, the heat exchanger method, multiblade procedures, and the use of a fixed abrasive multiwire. It is found that using $84/kg silicon, most sheet technologies would yield module prices in the $2.00/Wp to $3.00/Wp range.

Koliwad, K. M.↗

For the detection of subkiloelectron-volt X-rays

A large-area, imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1-micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. Over a sensitive area of 21 sq cm, the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

Ultraheavy cosmic rays - HEAO-3 results

The instrumentation and results from the Heavy Nuclei experiment on the HEAO 3 satellite are described. Six independently analyzed dual-gap ionization chambers measured the energy loss of the cosmic rays while a Cerenkov counter with 8 independently analyzed photomultipliers viewed two sheets of Pilot 425 plastic in a white box. Trajectories of the cosmic ray nuclei were determined in multiwire ionization hodoscopes. Variations in abundances were observed to be imperfectly ordered in terms of the first ionization potential, and volatility was also ruled out as the controlling factor. A predicted drop in abundance after Ba-56 was found, along with another sharp fall above Pb-82. Only one actinide-type event was detected during the 14 mos of viewing, a result consistent with other findings but which testifies against r-process formation.

Israel, M. H.↗

High throughput non-dispersive hard X-ray spectrograph with angular resolution for cosmic bursts, transients, and sources

An instrument concept which offers high throughput nondispersive spectroscopy in the 35-150 keV band for measuring line intensities and widths of faint supernovae is described. The design is based on existing xenon filled, two-dimensional, position sensitive, multiwired proportional counters. Effective detector areas of 1000 sq cm are readily achievable, and expansion to 10,000 sq cm per unit is feasible. Either single-unit or array operation to provide all-sky coverage with one arcmin resolution is possible. The instrument could be used to record gamma ray bursts and would have the capability of distinguishing particle events. Observations could also be made of X ray cyclotron lines and the Ti-44 lines expected to issue from a supernova explosion.

Gorenstein, P.↗

An imaging telescope for high energy gamma-ray astronomy

Recent tests of a gamma-ray imaging telescope, which incorporated a coded aperture mask and multiwire proportional counter system produced good images of a tritium target source which was used to generate the 20 MeV protons at a proton Van de Graaff accelerator. This paper indicates what performance might be expected if a large area drift chamber were used in conjunction with a coded aperture mask. The prospects for achieving significant scientific results if such a system were flown on a variety of space vehicles are discussed.

Frye, G.↗

Wire-Identification Instrument

Instrument automatically tests each wire in multiwire cable and identifies specified wire to be segregated or labeled and locates wire connected to specified connector pin. Instrument made with readily available CMOS integrated circuits. More efficient and reliable than conventional continuity testers and less expensive than computer controlled units.

Lonborg, J. O.↗

An imaging gas scintillation proportional counter for use in X-ray astronomy

An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.

Hailey, C. J.↗

Composition of cosmic-ray nuclei from boron to nickel for 1200 to 2400 MeV per nucleon

Balloon-borne measurements of cosmic-ray nuclear abundances for Z = 5-28 and energies 1.2-1.4 GeV/nucleon, obtained using the scintillation/Cerenkov-counter telescope and multiwire proportional counter described by Dwyer et al. (1984) on four flights from Texas and Oklahoma during 1973-1975, are reported. The data are presented in tables and graphs and compared with published observations. Charge separation (sigma = 0.2 units for Fe) and exposure factor (38 sq m sr h) are attained, and the findings are found to be in good agreement with the predictions of a simple leaky-box model of the Galaxy and a pure exponential path-length distribution, although a nested-leaky-box model with some truncation is possible. The delay between e-process nucleosynthesis and cosmic-ray acceleration is estimated on the basis of the Co abundance at greater than 100 d and probably greater than 100,000 yr.

Dwyer, R.↗

An imaging proportional counter for a 0.1 to 10 keV X-ray telescope

A xenon multiwire position-sensitive proportional counter (PSPC) with a high degree of long-term stability has been constructed and tested in detail. It is suitable for a 0.1 to 10 keV X-ray telescope such as AXAF, which it would share with detectors having better spatial and spectral resolution. Compared to other detectors, the larger format, higher quantum efficiency, and lower background of the PSPC makes it generally the most useful instrument for observations of diffuse cosmic X-ray sources and associations of sources more extended than a few tenths of a degree in diameter. Given the good spatial linearity, the systematic uncertainty for source locations is finer than an arcsecond. The spatial resolution varies as 0.3 mm/exp 0.5 (keV) over the range 0.2-4 keV, in accordance with theoretical limits determined by the size and the number of electrons in the primary charge cloud.

Gorenstein, P.↗

Fast transients - A search in X-rays for short flares, bursts, and related phenomena

The HEAO 1 A-2 database on fast high energy X-ray transients was examined for any discernible regularities. The data were taken over the interval 1977-79 with six collimated multiwire, multilayer, proportional counters that had a sensitivity sufficient for detecting events lasting 1-5 sec at energies as low as 8-120 keV. The entire sky was surveyed completely three times in the observational period. Best-fit position, error box corners, mean transient flux and quiescent flux data are provided for all six of the type 3 events that were found. All the sources were within the Galaxy. The duration of the events ranged from 60-2000 sec. The limited number of events observed leads to estimates of 10,000-200,000 events per year. It is suggested that all the events originate from hard flares occurring at a rate of 20,000/yr on dMe/dKe stars.

Connors, A.↗

Cosmic ray detectors

Work on the MSFC emulsion laboratory microscopes in which mechanical modifications previously made were verified is reviewed, as is a design study of a large area hybrid electronic/emulsion chamber balloon flight detector system. This design is built upon the experience obtained with the highly successful MSFC/UAH hybrid instrument flown by the JACEE consortium. The design included overall system design and specification, design and fabrication of a prototype large light diffusion for Cerenkov charge detector or scintillator, design of a multiwire proportional counter array and design of the gondola or flight support system.

Gregory, John C.↗

Development of a multistep detector for X-ray astronomy

The addition of a preamplification region is shown to dramatically improve the performance of a standard multiwire proportional counter (MWPC). This improvement is a direct consequence of effecting a large degree of preamplification in a perfectly uniform electric field and then transferring a well defined portion of this charge to a MWPC running at a modest gain. In this way, very large overall gas gains can be achieved without compromising energy resolution. The resulting device is known as a multistep detector.

Ramsey, B. D.↗