Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mounting configurations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact to Cooling Airflow from Truck Platooning: Preprint

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.

47 OTHER INSTRUMENTATION↗

Resonant torque differential magnetometry with high frequency quartz oscillators

Sensitive magnetometry has been a powerful probe for investigating quantum materials. Extreme conditions, such as sub-kelvin cryogenic temperatures and ultrahigh magnetic fields, demand further durability for sensitive magnetometry. However, significant mechanical vibrations and rapid magnetic field changes give enormous challenges to conventional magnetometry. Here, this article presents a possible solution to this problem by developing a new magnetometry technique using high-frequency quartz oscillators. The technique takes advantage of the symmetry and geometry of mechanical vibration configurations of standard commercially available MHz quartz oscillators, and the setup keeps the high quality factor resonance with the sample mounted on the oscillator. We further demonstrate the sensitivity of the technique using bismuth single crystals and a Fe 0.25 TaS 2 ferromagnetic material. Quantum oscillations are observed in the magnetometry response below 1 T, and the detected oscillation frequency is shown to come from the electron pockets of the bismuth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

TRUST Testing Procedure Documentation

The TRUST testbed was designed and fabricated to conduct vibration testing and validate the behavior of hyper-elastic foams in a pre-loaded condition. The main goals of this testbed design were to ensure symmetry, proper instrumentation alignment and mounting, simplified geometry to make the data analysis validation process more straightforward, and to apply and monitor the applied pre-load. Based off of the test parameters, a shaker system was purchased. The baseplate was designed to mount directly to the bolt holes provided on the top of the shaker table. It was determined that the specimens will be cylindrical and vary in thickness from 2-10mm. The baseplate riser, center-mass, and testbed cap were designed to be cylindrical to make alignment about the center axis more straightforward. It was determined to fabricate the parts previously mentioned using Aluminum 6061-T6 due to its stiffness in order to reduce the likelihood of the stiff material impacting the data being collected for the foam specimens. The design concept used to apply the pre-load to the testbed was a through bolt/nut configuration. A through hole was included in each piece of the testbed, specimens, and instrumentation large enough to allow for 1/8” clearance between the through bolt and each of these pieces. This was imperative to avoid causing friction and complicating the validation model. A load cell was then purchased and used to measure the pre-load being applied to the testbed. It was also required to collect data for 3 axes at 3 different locations 120° apart on the center-mass. This configuration was required to be placed on the cylindrical face and toward the top and bottom of the center-mass. Slots were milled out in the middle of each sensor block with tight tolerances for mounting each of the accelerometers at 120° apart. This same approach was taken to mount 2 accelerometers on the baseplate at 180° apart. Holes were milled out of the corners of each accelerometer mounting slot to relieve the corner and allow for a flat edge at the back of each slot. Sensor blocks were mounted into the center-mass using 6-32 bolts at the required locations. This initial testbed design was fabricated at the TA53 machine shop.

42 ENGINEERING↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 8 - Raw Data

Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM during Sequence 8, but it was parked during Sequence 9. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. Sonic anemometers were mounted on a strut downwind of the turbine. The strut was mounted to the T-frame, which was rotated to align the anemometers aft of the 9% and 49% radius locations at hub height. Because of this configuration, the tunnel balance data are considered invalid. Sequence 9 was designed to compare the downwind sonic anemometer readings with the upwind sonic anemometers without interference from the turbine. The rotor was parked with the instrumented blade at 0° azimuth. All pressure measurements obtained in Sequence 9 are invalid because sufficient time for temperature stabilization did not occur, thus all associated data values were flagged as not applicable by setting the measured values in the data file to 0.0000 Pa. This test is further described in Appendix G.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 9 - Raw Data

Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM during Sequence 8, but it was parked during Sequence 9. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. Sonic anemometers were mounted on a strut downwind of the turbine. The strut was mounted to the T-frame, which was rotated to align the anemometers aft of the 9% and 49% radius locations at hub height. Because of this configuration, the tunnel balance data are considered invalid. Sequence 9 was designed to compare the downwind sonic anemometer readings with the upwind sonic anemometers without interference from the turbine. The rotor was parked with the instrumented blade at 0° azimuth. All pressure measurements obtained in Sequence 9 are invalid because sufficient time for temperature stabilization did not occur, thus all associated data values were flagged as not applicable by setting the measured values in the data file to 0.0000 Pa. This test is further described in Appendix G.

17 WIND ENERGY↗

Apptainer Without Setuid

Apptainer (formerly known as Singularity) since its beginning implemented many of its container features with the assistance of a setuid-root program. It still supports that mode, but as of version 1.1.0 it no longer uses setuid by default. This is feasible because it now can mount squash filesystems, mount ext2/3/4 filesystems, and use overlayfs using unprivileged user namespaces and FUSE. It also now enables unprivileged users to build containers, even without requiring system administrators to configure /etc/subuid and /etc/subgid unlike other "rootless" container systems. As a result, all the unprivileged functions can be used nested inside of another container, even if the container runtime prevents any elevated privileges.

Dykstra, Dave↗

Measurement of DC Arc-Flash Incident Energy in Large-Scale Photovoltaic Plants: A Basis for Standardization

The deployment of high-power dc equipment is increasing in solar photovoltaic (PV) plants, but very few studies have quantified dc arc-flash risks. Currently, PV plant owners and operators rely on theoretical, simplified models, such as those in NFPA-70E and other publications, for the assessment of risk associated with dc arc-flash. Here, this article presents an overview of arc-flash risks in a PV system based on a series of field experiments based on IEEE-1584 in two large-scale ground-mounted PV plants. The experiments include various high-power dc equipment of a PV plant, such as central inverters, combiner boxes, recombiner boxes, string inverters, and multiple configurations of electrodes in a 20-in calibration cube. The study reveals that none of the available dc arc-flash models are applicable for a PV plant. This work is an important first step toward developing an improved model that more accurately assesses dc arc-flash risk in a PV plant.

14 SOLAR ENERGY↗

On-Device Lead Detention for Perovskite Solar Cells

As the power conversion efficiency (PCE) of perovskite solar cells (PSCs) have reached above 25.5%, the commercialization of PSCs appears to be imminent due to its lower fabrication cost, simpler manufacturing processes, and larger processing area over Si-based solar cells that dominate the current photovoltaic (PV) market. While many efforts have focused on tackling the stability and scalability issues with promising advances, the potential lead (Pb) toxicity issue has remained a concern of PSCs. Unlike the metallic Pb, the Pb 2+ in perovskite generally exhibit high solubility in water. However, Pb 2+ has so far appeared to be a necessary component in all high-efficiency PSCs. Handful methods have been explored to mitigate the potential Pb2+ leaking issue, which can be generally categorized as physical encapsulation and our pioneering chemical absorption method, which was extended by others later. Since device damage is inevitable in outdoor conditions, physical encapsulation alone is not sufficient to mitigate the long-term risk of leakage of soluble Pb 2+ to the environment under severe weather conditions. As a result, the chemical absorption approach has recently attracted significant attention as a more effective solution to confine the potential lead leakage. Hence, it is of great value to develop durable and highly efficient Pb-absorbing components that can be conveniently mounted onto the standard PSC stack as an add-on accessory in line with the encapsulation of PSCs instead of modifying the standard device fabrication and/or device configuration.

14 SOLAR ENERGY↗

Harvesting Subsea Water Motion to Provide Clean Electrical Power

This TEAMER project had three main objectives related to characterizing the performance of a vortex-induced vibration (VIV) marine energy harvesting device called the Whatever Input To Torsion (WITT). The first was to characterize the motion of the WITT device as it vibrates on top of a pipe in a natural tidal flow. The second was to measure how much electricity the WITT device generates when it is deployed on top of a pipe that is secured to the seabed with a lander. The third objective was to measure how much electricity the WITT device generates in the same configuration but with a longer pipe. This TEAMER project succeeded in satisfying the first objective by measuring the motion of the WITT device with an inertial measurement unit (IMU) mounted in the WITT housing. The motion was described by examining changes in the acceleration, pitch, roll, and yaw, and displacement. The frequency of the motion was characterized using spectral analysis. The TEAMER project succeeded in reaching the second objective by measuring the power produced by the WITT. It is reported here as the average and maximum power in hourly intervals. WITT Energy decided to not have us pursue the third objective of testing a longer pipe because the first test was unexpectedly successful at having the system vibrate at the target frequency. A longer pipe would have resulted in a decreased frequency and therefore not have been a useful test. Based on these findings, the decision was made to keep the same pipe length for both tests and improve on other aspects of the test structure that had failed during the first test. The key finding of this TEAMER project is that the WITT is capable of generating electricity in moderate flow speeds when it is in a housing that is attached to a 2.5 m pipe and secured to the seabed by a lander. This report contains the first power values for a VIV instrument that generates electricity from a pendulum swinging at the top of a long pipe. The experiment demonstrated that the vibration frequency of the device varied with the tidal current speed, which changed throughout a given tidal cycle. This meant that the desired peak frequency was not sustained for more than one hour. The success of this TEAMER test provides evidence that continued research in the area of electricity generation from VIV holds promise as a source of marine energy for offshore applications. Future tests should focus on refining the pipe length equations and improving the power take off system of the WITT power electronics. In addition, experiments aimed at expanded testing and evaluation (e.g. longer than one month) are needed to measure the power production at higher tidal current speeds and test the system's durability.

Branch, Ruth A. (ORCID:0000000202356719)↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

Graham, Thomas G.↗

Electronics module with raceway and submodules

Systems and methods for providing an electronics module including a raceway for mounting submodules and establishing electrical communication with said submodules. The raceway comprises a base structure and a conductive trace formed by a conductive plating process. Connection pads on the raceway are configured to receive connection nodes of the submodules for providing a continuous electrical connection between the raceway and the submodules for electrical communication and power transmission.

Eickbush, Ryan J.↗

Thermal images collected during large-scale 3D printing with Ingersoll MasterPrint

This data set contains images produced to test the performance of anomaly and fault detection methods in the context of additive manufacturing. Two print jobs were executed using the Ingersoll MasterPrint with the Model 30 Strangpresse extruder. The material used was Techmer compounded polylactic acid (PLA) with wood flour as a filler (80/20 PLA/WF by weight). The first print job consists of the 3D printing of a hexagonal cylinder with a two-bead wall. This print was sliced at a gantry velocity of 3000 millimeter per minute, and an extruder screw speed of 68.14 rotations per minute. This are considered the normal operating conditions. A second hexagonal cylinder was printed using a reduced extruder screw speed, 15% lower than under normal operating conditions. The images were collected with a Teledyne FLIR Lepton 3.5 infra-red camera, a small form factor radiometric long-wave infrared camera with a spectral range of 8 µm to 14 µm. Sensor resolution was 160x120 pixels, with a pixel size of 12 µm, a temperature range of -10 - 450°C, and an accuracy of +/- 10°C in its low gain configuration. Images in this data set were collected with cameras oriented at the printer nozzle. The nozzle camera setup consisted of two cameras located 12.5cm from the nozzle center. These were mounted directly to the print head, so that the camera positions relative to the print direction would remain constant as it rotated around its C-axis to follow the print path. One camera was placed ahead of the nozzle to capture the previous layer immediately before being covered by the new layer of material, while the second camera was placed behind the nozzle and captured the freshly extruded bead. Images are collecting during each phase of the print: (a) idle (i.e., no material deposited), (b) extrusion (i.e., to prime the extruder), and (c) printing (deposition of material to manufacture the hexagonal cylinder).

36 MATERIALS SCIENCE↗

Magnetostrictive EMAT for Nuclear Spent Fuel Canisters

One approach for mitigation of stainless steel (SS) spent fuel canisters (SFCs) is to coat the welds or even the entire SFC with a cold-sprayed nickel coating. The coating can serve as a magnetostrictive interface between an electromagnetic acoustic transducer (EMAT) and the SS plate material. The EMAT can send ultrasound into the canister and “listen” for reflections caused by chloride-initiated stress corrosion cracking (CISCC) or other damage mechanisms that may lead to leaks if undetected and unmitigated. Here, this project outlines an approach for monitoring the integrity of SFCs using magnetostrictive EMAT sensors, which emit and detect discontinuity-initiated reflections indicative of pits or cracks likely arising from CISCC. Flat 13 mm SS plates with welds similar to actual canister welds were prepared, with flat-bottom holes 3 mm and 6 mm deep and 6 mm in diameter placed within the weld heat-affected zone (HAZ). The most effective sensor configurations were able to detect critical discontinuities more than 2 m away. Although a single sensor could be robotically deployed, the large volume covered by each sensor could support a small number of permanently mounted sensors, equipped with an external connector for periodic interrogation. The HAZ of a hypothetical SFC cylindrical surface could be effectively monitored with just 16 sensors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System and methods for deploying payloads

Embodiments of the present invention include systems for launching primary or secondary payloads or actuating other launch vehicle or payload or instrumentation devices. The system includes an adapter assembly and at least one sequencer mounted to the adapter assembly. The sequencer includes: controller boards, each of the controller boards having a controller for controlling deployment of the payloads and data files; output ports coupled to the controller boards and configured to transmit signals from the controller boards to dispensers therethrough, deployment mechanisms containing the payloads, the adapter assembly having channels for accommodating the dispensers; and a detector coupled to the controller boards and adapted to detect an external signal and, in response to the external signal, to send an initiation signal to the controller boards. The system also includes at least one power supply coupled to the sequencer and adapted to provide an electrical power to the sequencer.

42 ENGINEERING↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.

Freidkes, Brett R.↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗