Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monitoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Remote water monitoring system

A remote water monitoring system is described that integrates the functions of sampling, sample preservation, sample analysis, data transmission and remote operation. The system employs a floating buoy carrying an antenna connected by lines to one or more sampling units containing several sample chambers. Receipt of a command signal actuates a solenoid to open an intake valve outward from the sampling unit and communicates the water sample to an identifiable sample chamber. Such response to each signal receipt is repeated until all sample chambers are filled in a sample unit. Each sample taken is analyzed by an electrochemical sensor for a specific property and the data obtained is transmitted to a remote sending and receiving station. Thereafter, the samples remain isolated in the sample chambers until the sampling unit is recovered and the samples removed for further laboratory analysis.

Grana, D. C.↗

Simulator evaluation of a display for a Takeoff Performance Monitoring System

A Takeoff Performance Monitoring System (TOPMS) has been developed to provide the pilot with graphic and numeric information pertinent to his decision to continue or abort a takeoff. The TOPMS information display consists primarily of a runway graphic overlaid with symbolic status, situation, and advisory information including: (1) current position and airspeed; (2) predicted locations for reaching decision speed (V sub 1) and rotation speed (V sub R); (3) groundroll limit for reaching (V sub R); (4) predicted stop point for an aborted takeoff from current conditions; (5) engine-status flags; and (6) an overall situation advisory flag that recommends continuation or rejection of the takeoff. In this study, 32 experienced multi-engine pilots evaluated the TOPMS on the Langley B-737 real-time research simulator. They rated the system satisfactory - good and judged it to be suitable for implementation on an aircraft. The TOPMS, the TOPMS simulation, and the results of the simulator evaluation are described here. Appendices contain the pilot's prebriefing package (written explanation of the TOPMS--sent to the pilots prior to their visit), evaluation instructions, debriefing questions, and rating criteria (organized into a flow diagram similar to the Cooper-Harper diagram for evaluation of aircraft handling qualities).

Middleton, David B.↗

Reconfigurable Sensor Monitoring System

A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

Alhorn, Dean C.↗

Valve Health Monitoring System Utilizing Smart Instrumentation

The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

Jensen, Scott L.↗

Ulysses spacecraft control and monitoring system

The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.

Hamer, P. A.↗

Design, development, and field demonstration of a remotely deployable water quality monitoring system

A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

Wallace, J. W.↗

Fission Gas Monitoring System Efficiency Calibration Summary Report

The Fission Gas Monitoring System was designed to work in conjunction with the Fuel Accident Condition Simulator Furnace and is used to measure fission gas releases during post-irradiation fuel heating tests. A high-purity helium sweep gas is swept past the heated fuel sample in the furnace and routed to a fission gas monitoring system, which cryrogenically traps the krypton (Kr) and xenon (Xe) fission gases. As the radioactive species of the trapped gas decays, high-purity germanium detectors monitor the amount of fission gas in each trap. The primary fission product present in this test is 85Kr, which has a 10.76-year half-life. The presence of 85Kr indicates particle defects and iodine release. There is also the potential for re-irradiating the fuel compacts in the Neutron Radiography Reactor in the Hot Fuel Examination Facility basement. With re-irradiation, it is possible to have xenon fission gas present, specifically 133Xe, which has a 5.243-day half-life. Re-irradiation also produces 131I, which is important for design-basis accidents and regulatory licensing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Description of real-time Ada software implementation of a power system monitor for the Space Station Freedom PMAD DC testbed

The Ada language software development to perform the electrical system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed is described. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electrical power system to be used in the Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 382/20e computers connected through an 802.4 local area network. One of these computers is designated as the control node with the other four acting as subsidiary controllers. The subsidiary controllers are connected to the power control components with a Mil-Std-1553 network. An operator interface is supplied by adding a sixth computer. The power system monitor algorithm is comprised of several functions including: periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data is collected from the switchgear sensors every 100 milliseconds, then passed through a 2 Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The reporting mechanism notifies an operator of any abnormalities in the system. Once per second, the system monitor provides data to the control node for further processing, such as state estimation. The system monitor required a hardware time interrupt to activate the data acquisition function. The execution time of the code was optimized using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities. A summary of the advantages and side effects of this technique are discussed.

Ludwig, Kimberly↗

Battery Monitoring System

The component that is powered by the battery pack being monitored is a valuable asset and must be in working condition at all times. Battery chemistry and characteristics have a major role in how to evaluate the state of the battery. The battery monitoring system has many parts that lead to an accurate battery reading. The components consist of a coulomb counting device, end of life voltage detection, a consideration of use for a real-time clock (RTC), temperature sensor, and non-volatile random-access memory (NVRAM). The combination of these elements allows the monitoring system to be highly reliant. Moving forward a better implementation of the ideas in this paper and further testing should ensure a high-quality battery monitoring system.

25 ENERGY STORAGE↗

Real-time and Autonomous Water Quality Monitoring System Based on Remotely Operated Vehicle

Existing water quality monitoring systems near hydropower facilities are limited by the lack of mobility of the sensors’ carrier platform. Most systems use a buoy, a mounting fixture attached to a solid structure, or a human worker, which significantly limits the selection of the sampling sites and poses safety risks during data collection and equipment maintenance. To improve on this technology, we developed an autonomous water quality monitoring system that can operate in dangerous water environments near hydropower facilities for water sampling at multiple locations. The goal is to enable safe, timely, and comprehensive water-quality data collection; maximize power generation revenue with improved operational control; and reduce Federal Energy Regulatory Commission and state water quality monitoring costs for compliance. The system incorporates a remotely operated vehicle as the mobile monitoring platform, a dissolved oxygen sensor for monitoring water quality, a tether management system for automatically winding the tether, a solar mobile docking platform for suppling power to the ROV, and a web-based graphical user interface for data post-processing and visualization. In addition, preliminary field research are presented to demonstrate the system capabilities.

Salalila, Aljon L.↗

Cost analysis of atmosphere monitoring systems

The cost analyses of two leading atmospheric monitoring systems, namely the mass spectrometer and the gas chromatograph, are reported. A summary of the approach used in developing the cost estimating techinques is presented; included are the cost estimating techniques, the development of cost estimating relationships and the atmospheric monitoring system cost estimates.

Yakut, M. M.↗

Airplane-Runway-Performance Monitoring System

Airplane-Runway-Performance Monitoring System (ARPMS) increases safety during takeoffs and landings by providing pilots with symbolic "head-up" and "head-down" information pertinent to decisions to continue or abort takeoffs or landings. Provides graphic information concerning where airplane could be stopped. Pilot monitors ground speed and predicted stopping point while looking at actual runway. High potential for incorporation into cockpit environment for entire aerospace community.

Middleton, David B.↗

Description and field test of an in situ coliform monitoring system

A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

Grana, D. C.↗

Aircraft Engine-Monitoring System And Display

Proposed Engine Health Monitoring System and Display (EHMSD) provides enhanced means for pilot to control and monitor performances of engines. Processes raw sensor data into information meaningful to pilot. Provides graphical information about performance capabilities, current performance, and operational conditions in components or subsystems of engines. Provides means to control engine thrust directly and innovative means to monitor performance of engine system rapidly and reliably. Features reduce pilot workload and increase operational safety.

Abbott, Terence S.↗

System monitors discrete computer inputs

Computer system monitors inputs from checkout devices. The comparing, addressing, and controlling functions are performed in the I/O unit. This leaves the computer main frame free to handle memory, access priority, and interrupt instructions.

Burns, J. J.↗

Automated patient monitoring system

Radio-linked patient monitoring system collects several channels of physiological data from as many as 64 hospital patients and transmits the data in digital form to a central control station. The system consists of a central control station and battery-operated patient units comprising small strap-on electronics packages.

Bedard, R. E.↗