Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modelica”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗

An Open-Source Virtual Testbed for a Real Net-Zero Energy Community

Net zero energy communities (NZECs) are critical to ensure sustainability and resilience of modernized power systems. System modeling helps overcome technical challenges in designing and operating NZECs. In this paper, we present the modeling work based on a real NZEC. Two sets of models are developed: higher-fidelity physics-based models considering the interaction between subsystems of the studied NZEC and capturing fast-dynamics; and lower-fidelity data-driven models requiring less resource to establish and/or run. All models are validated against measurements from this real NZEC. In addition, we create a simulation framework which streamlines the processes for simulation and thus allows using developed models to form a virtual testbed. To demonstrate the usage of the virtual testbed, a case study is conducted where a building-to-grid integration control is evaluated via simulation. The evaluation results suggest that the tested control significantly smooths the power draw of the studied community and doesn’t sacrifice the thermal comfort to a great extent.

Huang, Sen↗

Review and Modeling of Integrated Energy Systems with Nuclear Reactor Coupled Desalination and District Heating

Detailed reviews of a past advanced nuclear reactor based integrated energy system, as well as other nuclear reactor and fossil fuel based integrated energy systems have been performed for this work. Review of the utilization of heat from nuclear reactors for various applications and cogeneration has been done. The heat can be utilized by extraction of the steam from the turbine while the steam is still at a desired temperature. While use of nuclear process heat for district heating in countries like Finland, France, China, Poland, and elsewhere is discussed, more focus of the review has been given on nuclear desalination processes. Integrated energy systems (IES) where distinct types of reactors like PWR, BWR, sodium cooled fast reactor, heavy water reactor and other advanced reactors are coupled with various nuclear desalination processes like multi-effect distillation (MED), multi-stage flashing (MSF) and reverse osmosis (RO) methods have been discussed. The nuclear desalination plant at Aktau has been discussed in more detail due to its decades of successful operation. The IES of the Aktau plant coupled with 5-effect MED desalination plant has been taken as a reference for modeling the Open Modelica (OM) based IES of this work. Here, the OM IES model shows good agreement with the MED plant output of Aktau and can be extended for future applications of IES.

42 ENGINEERING↗

Thermal Energy Storage Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage models developed within the HYBRID Modelica repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of concrete, latent heat, and packed-bed thermocline energy storage technologies for deployment in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to cyclically charge and discharge when exposed to time-varying boundary conditions. In addition, low-level surrogate models for some of the thermal energy storage technologies were created using Python. These lower order Python files are much cheaper to run (i.e., computationally faster) and thus operate well when incorporated within the stochastic optimization problems run for the IES program. Moreover, economic data was collected for use within the INL-developed Framework for Optimization of ResourCes and Economics (FORCE). This information is incorporated within the FORCE platform. This work has resulted in creation of systems-level models for concrete, latent heat, and thermocline thermal energy storage systems with associated control systems. Now that these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies (e.g., Storworks Power, EnergyNest) can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

25 ENERGY STORAGE↗

Delivery of Dynamic Thermal Energy Storage Models and Advanced Reactor Concept Models to the HYBRID Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), sodium fast reactor (SFR), compressed air energy storage (CAES), liquid air energy storage (LAES) and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed. Also detailed in this report are future development goals for the HYBRID repository including adding suites of steady-state models, economic costing information, and reduced-order models. By adding these models in addition to the physical transient models currently existing within HYBRID, HYBRID will be a fully integrable tool for FORCE users.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status Report on Thermal Delivery Modeling in HYBRID

This report details the modeling efforts consistent with the HYBRID repository of the Integrated Energy Systems (IES) program, motivated to develop information data tables characterizing the thermodynamic losses associated with transporting thermal energy over large distances. The described model establishes a methodology to currently characterize the impacts of certain parameters such as distance, piping geometry, and heat transfer fluid among others as well as sets up ability to interconnect the delivery model into Modelica IES simulations in the future. This report describes the modeling efforts completed and describes some of the future studies that will be done using results produced by the modeling efforts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sand-Based Thermal Storage for Building Heating Applications: A District Energy Case Study

Buildings account for 40% of global energy consumption and contribute to 30% of global carbon emissions. As energy from renewable sources increases in availability and building designers push for increased electrification, thermal energy storage (TES) systems will play a crucial role in extending the usable time horizon of renewable energy. While water, molten salt, and phase change materials are typically used for building TES heating applications, silica-sand has emerged as an alternative medium for concentrated solar power applications due to its low cost, wide availability, and comparable system efficiency. This paper proposes a new silica-sand particle-based TES system for building heating applications. In this work, a novel steam plant for district heating applications is first designed to utilize silica-sand TES, which can be used for different district energy systems. To demonstrate the silica-sand TES plant performance, the design is modelled in Modelica based on a case study on the University of Colorado Boulder’s campus. The simulation results show that the sand TES plant is more costly to operate than a gas-boiler based plant due to the low cost of natural gas, while the site EUI and carbon intensity can be improved. This novel system shows initial promise as a low-carbon alternative to conventional natural gas steam boilers but will require further modelling and follow-up research to improve its energy efficiency. An eventual rise in natural gas prices, and reduction of electricity prices, could improve the economic viability of this system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

Modeling and Optimization of a Nuclear Integrated Energy System for the Remote Microgrid on El Hierro

Nuclear microreactors are a potential technology to provide heat and electricity for remote microgrids. There is potential for the microgrid on the island of El Hierro to use a microreactor, within an integrated energy system (IES), to generate electricity and provide desalinated water. This work proposes a workflow for optimizing and analyzing IESs for microgrids. In this study, an IES incorporating a microreactor, thermal energy storage (TES) system, combined heat and power plant, and a thermal desalination plant was designed, optimized, and analyzed using Idaho National Laboratory’s Framework for Optimization of Resources and Economics (FORCE) toolset. The optimization tool, Holistic Energy Resource Optimization Network (HERON), was used to determine the optimal capacity sizes and dispatch for the reactor and thermal energy storage systems to meet demand. The optimized reactor and TES sizes were found to be 11.61 MWth and 58.47 MWhth, respectively, when optimizing the IES to replace 95% of the island’s existing diesel generation needs. A dynamic model of the system was created in the Modelica language, using models from the HYBRID repository, to analyze and verify the dispatch from the optimizer. The dynamic model was able to meet the ramp rates while maintaining reactor power with minimal control adjustments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Hybrid User Manual

This document is the user manual for the Hybrid Repository that is a part of the Integrated Energy Systems program. The Hybrid Repository is a collection of physical modelica models used for the creation of transient integrated energy systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗