Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum energy control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Catalytic Resonance Theory: Experimental and Kinetic Interpretation of Programmable Catalysis

The complexity of programmable catalysts that change in the physical or electronic state on the time scale of a catalytic turnover results in uncertainty in the kinetic outcome of common measurements with dynamic catalyst experiments. To provide an interpretation of utility to experimentalists, a general programmable catalytic reaction exhibiting high turnover efficiency was simulated to understand the kinetic behavior of catalysts with varying frequency, binding energy, oscillation amplitude, and minimum oscillation binding energy at different temperatures and reactant gas pressures. The time-averaged catalytic rate for varying temperature in the form of an Arrhenius plot exhibited three distinct kinetic regimes, with the intermediate temperatures or applied frequencies exhibiting zero slope, indicative of barrier-free kinetic control. Transitions in experimentally measurable kinetic regimes with both temperature and applied catalyst oscillation frequency were associated with transitions in the sensitivity of reaction rate constants and degrees of rate control. Furthermore, these distinct kinetic macroscopic features specific to programmable catalysts were identified for observation in experimental dynamic kinetic measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring topography-based methods for downscaling subgrid precipitation for use in Earth System Models

Topography exerts major control on land surface processes. To improve representation of topographic impacts on land surface processes, a new topography-based subgrid structure has been introduced to the Energy Exascale Earth System Model to represent the subgrid heterogeneity of surface elevation. To take advantage of the new subgrid structure for improving land surface modeling, this study explores four variations of topography-based methods for downscaling grid precipitation to the corresponding subgrids. In the first three methods, the deviation of the subgrid precipitation from the grid’s is equal to the grid precipitation multiplied by the ratio of the elevation difference between the subgrid and grid mean to a specified elevation equals to the grid elevation, the difference between the maximum and minimum subgrid elevation, and the maximum subgrid elevation, respectively. The second method limits the ratio to 0.5 to avoid extreme values on mountains and the third method accounts for the slope effect. The fourth method is similar to the third method except that the Froude Number is used to limit the numerator in a blocking regime of the ambient flow. The downscaled precipitation is evaluated using the PRISM precipitation data over the U.S. using statistical metrics. Results show that by accounting for topographic slope besides elevation, the third and fourth methods show clear advantages over the first and second methods. Furthermore, introducing the Froude Number in the fourth method improves downscaling skill and shows consistent advantages over the third method in areas with larger subgrid heterogeneity across different grids sizes.

Tesfa, Teklu K.↗

Adaptive PV Frequency Control Strategy Based on Real-time Inertia Estimation

The declining cost of solar Photovoltaics (PV) generation is driving its worldwide deployment. As conventional generation with large rotating masses is being replaced by renewable energy such as PV, the power system’s inertia will be affected. As a result, the system’s frequency may vary more dramatically in the case of a disturbance, and the frequency nadir may be low enough to trigger protection relays such as under-frequency load shedding. The existing frequency-watt function mandated in power inverters cannot provide grid frequency support in a loss-of-generation event, as PV plants usually do not have power reserves. Here, a novel adaptive PV frequency control strategy is proposed to reserve the minimum power required for grid frequency support. A machine learning model is trained to predict system frequency response under varying system conditions, and an adaptive allocation of PV headroom reserves is made based on the machine learning model as well as real-time system conditions including inertia. Case studies show the proposed control method meets the frequency nadir requirements using minimal power reserves compared to a fixed headroom control approach.

14 SOLAR ENERGY↗

Evaluation of the mean excitation energy of liquid argon

Current and future experiments need to know the stopping power of liquid argon. It is used directly in calibration, where commonly the minimum-ionizing portion of muon tracks is used as a standard candle. Similarly, muon range is used as a measure of muon energy. More broadly, the stopping power figures into the simulation of all charged particles, and so uncertainty propagates widely throughout data analysis of all sorts. The main parameter that controls stopping power is the mean excitation energy, or I-value. Experimental information for argon's I-value come primarily from measurements of gaseous argon, with a very limited amount of information from solid argon, and none from liquid argon. These measurements are reviewed, along with a discussion of the difference in central value and uncertainty incurred by the difference of phase. The values newly recommended by this note are $(188 \pm 6)$ eV for gaseous argon and $(197 \pm 8)$ eV for liquid argon (68% C.L. in each case).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationship between Grain Size and Sample Thickness on the Creep-Rupture Performance of Thin Metallic Sheets of INCONEL Alloy 740H

A study was conducted on INCONEL® alloy 740H® to examine the role of grain size and sheet thickness on the alloy’s creep-rupture behavior. Three different starting sheet thicknesses were utilized and multiple heat-treatment conditions anticipated for compact heat exchanger (CHX) manufacturing were applied to produce a range of grain sizes. Creep-rupture testing was conducted at 750 °C for times up to about 6000 h and the results were compared to wrought databases. The data show that both creep strength and ductility were important factors in the overall creep performance of the sheets. Reductions in performance were observed due either to accelerated creep when grain size was fine or loss of rupture ductility when grain sizes approached the sheet thickness. Some combinations of heat-treatment and thickness were able to produce typical expected wrought creep properties. Historically a ‘rule-of-thumb’ requirement for creep testing suggests 3-5 grains per sample minimum dimension to ensure homogeneous behavior. This research shows that to ensure representative wrought creep performance (i.e. no effect of sample size), the sample minimum cross-section should be 10 times the average ASTM grain size. Statistical analysis of the microstructures suggests the population of larger grains as a controlling feature in creep failure.

14 SOLAR ENERGY↗

Active High Assurance Authentication Protocol (AHAAP)

The AHAAP Maturation Project involves maturation and evaluation of a patented zero-trust tamper-resistant high-assurance session-less dynamic and active device authentication protocol that simultaneously authenticates identity and provides integrity verification in a single step, substantially reducing the risk of cyberattack, and eliminating the need for costly and complex conventional communication security systems requirements (i.e., cryptography, Public Key Infrastructure (PKI), and key management). These cybersecurity attributes of the technology must be preserved when applying the technology to different cybersecurity solutions, including Command & Control (C&C), Over-the-Air (OTA) update, Common Access Card (CAC), and distributed energy resource (DER) implementations, among others. The technology research objective is to test and verify that the cybersecurity attributes of the technology are not degraded in different cybersecurity applications. The primary technology development objective is to build minimum viable products to demonstrate the technology addresses today’s cybersecurity threats so that prospective investors, strategic partners, regulatory agencies, and commercial customers can interact with and assess the protection assured by the technology. The AHAAP Maturation Project goal is to develop, test, and validate one or more AHAAP implementations. The AHAAP Maturation Project tasks are: (i) engineer AHAAP implementation software, (ii) build a functional prototype that implements the AHAAP software for demonstration, testing, analysis, and evaluation purposes, and (iii) generate a report detailing the results of the AHAAP C&C software and hardware implementation. The final project deliverables are: (i) AHAAP software implementation and prototype, (ii) a report from Sandia National Laboratories detailing the results of the AHAAP implementations.

97 MATHEMATICS AND COMPUTING↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Energy Storage Improves Power Plant Flexibility and Economic Performance

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenue, as well as to operate air pollution control devices at design conditions. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant operating or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation, such as wind and solar, is shifting the traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and a lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. Recent studies have shown that the flexibility of a coal-fired power plant can be improved by energy storage. The objective of this work was to analyze a set of energy storage options and determine their impact on the flexibility and economics of a representative coal-fired power plant. The effect of three energy storage systems integrated with a coal power plant on plant flexibility and economics was investigated. The results obtained in this project show that energy storage systems integrated with a thermal power plant improve plant flexibility and participation in the energy and ancillary services markets, which improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Efficient excitation and control of integrated photonic circuits with virtual critical coupling

Critical coupling in integrated photonic devices enables the efficient transfer of energy from a waveguide to a resonator, a key operation for many applications. This condition is achieved when the resonator loss rate is equal to the coupling rate to the bus waveguide. Carefully matching these quantities is challenging in practice, due to variations in the resonator properties resulting from fabrication and external conditions. Here, we demonstrate that efficient energy transfer to a non-critically coupled resonator can be achieved by tailoring the excitation signal in time. We rely on excitations oscillating at complex frequencies to load an otherwise overcoupled resonator, demonstrating that a virtual critical coupling condition is achieved if the imaginary part of the complex frequency equals the mismatch between loss and coupling rate. We probe a microring resonator with tailored pulses and observe a minimum intensity transmission T = 0.11 in contrast to a continuous-wave transmission T = 0.58, corresponding to 8 times enhancement of intracavity intensity. Our technique opens opportunities for enhancing and controlling on-demand light-matter interactions for linear and nonlinear photonic platforms.

42 ENGINEERING↗

Atomistic determination of Peierls barriers of dislocation glide in nickel

The Peierls barrier measures the lattice resistance to dislocation glide in crystalline solids. We use the nudged elastic band (NEB) method to calculate the Peierls barriers for screw and edge dislocation glide in a face-centered cubic (FCC) metal of Ni. The minimum energy paths (MEPs) across single or sequential Peierls barriers are determined under shear loading. The NEB results show the decreasing Peierls barrier with increasing shear stress, giving the Peierls stress at which the Peierls barrier vanishes. The effects of boundary condition and system size on Peierls barriers are studied by comparing strain- and stress-controlled NEB results. Furthermore, the free-end NEB methods are applied to determine MEPs with improved computational efficiency. The NEB results are also used to evaluate the energetic driving force of dislocation glide, which is consistent with that determined from the Peach-Koehler force. The accuracy of the present NEB results based on an empirical interatomic potential is assessed by comparison with a machine-learning potential. This work demonstrates the robust and efficient quantification of Peierls barriers to dislocation glide in an FCC metal, and it lays a solid foundation for the atomistic determination of Peierls barriers in compositionally complex alloys with the FCC structure in future studies.

42 ENGINEERING↗

Relationship between atomic and electronic structure in Ln-bearing oxides

Metastable states of matter are of great interest as they offer the promise of novel functionality. They are often a natural consequence of exposure to nonequilibrium environments. In oxides, metastability can take the form of new polymorphs, chemical disorder, and even amorphization. While significant attention has been given to the impact those changes have on the atomic properties of the material, the corresponding changes in the electronic structure have received less attention. Here, using density functional theory, we consider how the electronic structure varies with potential metastable structures in two classes of lanthanide-bearing oxides—pyrochlores and interlanthanide sesquioxides. We find that the changes depend strongly on both the crystal structure and crystal chemistry of the compound with, for example, disordering and amorphization either increasing or decreasing the bandgap depending on the chemistry. For the 𝐴 2 ⁢𝐵 2 ⁢O 7 pyrochlores, we find different dependencies of the bandgap on the 𝐴 = 𝐿⁢𝑛 cations as the 𝐵 cation is changed, which we relate to the nature of the density of states at the conduction band minimum for different 𝐵 chemistries. Our calculations are validated by electron energy loss spectroscopy measurements for two pyrochlore compounds in which amorphization does reduce the bandgap, consistent with our calculations on these two compounds. In conclusion, our results highlight the relationship between atomic and electronic structure and how radiation can be used to modify and potentially control the electronic properties of oxides.

36 MATERIALS SCIENCE↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

Stormwater Pollution Prevention Plan (SWPPP) for Site Wide Landscaping Project

Kier + Wright, as Qualified SWPPP Developer (QSD), puts forth this Storm Water Pollution Prevention Plan (SWPPP) for the SNL/CA Site Landscaping Project at Sandia National Laboratories/California (SNL/CA), 7011 East Avenue, Livermore, California (SNL/CA). The property is owned by the U.S. Department of Energy, and managed and operated by National Technology & Engineering Solutions of Sandia (NTESS), LLC. The project proposes landscape improvements throughout SNL/CA. Per the California State Water Resources Control Board’s (California State Water Board) Construction General Permit (CGP), a SWPPP is required when 1 acre or more of land is disturbed. The project site area exceeds the minimum acreage threshold of 1 acre and therefore requires SWPPP implementation. QSD has determined the sediment risk for this project, based on soil type at the site and starting and ending dates of construction, to be low (Section 3.4.1 and Appendix B). Receiving water for this project is the Arroyo Seco. QSD has determined the Arroyo Seco to be a high-risk receiving water because it has the three beneficial uses of “spawn”, “cold”, and “migratory” (Sections 3.3 and 3.4.2 and Appendix B). QSD has determined the overall risk level for the site to be Risk Level 2, based on a combination of low sediment risk and high receiving water risk (Appendix B). As such, QSD has delineated a variety of Best Management Practices (BMPs) to be employed during project construction to reduce or eliminate pollutants in stormwater runoff or any other discharges from the Project site. In addition to site-specific BMPs, this SWPPP report provides instruction for on site monitoring. Electronic copies of required documentation such as inspection reports, REAPs, annual report documentation, etc. shall be submitted to NTESS Sandia Delegated Representative via Newforma.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of Blown Powder Directed Energy Deposition Angle On Overspray Contamination

Abstract Blown powder directed energy deposition (DED) hybrid machine tools are particularly beneficial when the net shape of a component is to be manufactured in an additive and machined interleaved fashion. This investigation seeks to analyze the effect of the additive head lean angle relative to the part on blown powder DED surface contamination due to overspray. These hybrid DED platforms are commonly installed on multi-axis machining systems where the lean of the deposition head relative to the component surface can be controlled by tilting the component. The blown powder DED process has a 10–50% lower catchment efficiency as compared to wire fed DED systems. This excess powder is still fed towards the deposition location where the particles are heated by the laser and rebound off the melt pool. Some of these heated particles impact the previously machined thin-wall surface. While the deposition process and tool path planning process has been evaluated, the effect of the overspray due to lean angle of the deposition head on the previously thin-wall machined surface is not yet fully understood. This investigation found that minimum lean angle coincides with minimal overspray effect with nearly no contamination. If a lean angle is required, the maximum lean angle possible should be implemented for the smallest effected overspray area on the machined surface which was found to decrease the affect zone by half compared to intermediate lean angles. A diameter divergence was also noticed as the deposition angle was increased. In this study, a thorough analysis of the surface and geometric effects when depositing thin-walled components at varying angles is completed. It has been shown that part quality can be significantly affected by lean angle and thus must be incorporated as an additional design consideration in the manufacturing process.

Heinrich, Lauren↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗