Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum energy control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fast Na diffusion and anharmonic phonon dynamics in superionic Na 3 PS 4

The design of new solid electrolytes (SEs) hinges on identifying and tuning relevant descriptors. Phonons describe the atomic dynamics in crystalline materials and provide a basis to encode possible minimum energy pathways for ion migration, but anharmonic effects can be large in SEs. Identifying and controlling the pertinent phonon modes coupled most strongly with ionic conductivity, and assessing the role of anharmonicity, could therefore pave the way for discovering and designing new SEs via phonon engineering. In this work, we investigate phonons in Na 3 PS 4 and their coupling to fast Na diffusion, using a combination of neutron scattering, ab initio molecular dynamics (AIMD), and extended molecular dynamics based on machine-learned potentials. We identify that anharmonic soft-modes at the Brillouin zone boundary of the anharmonically stabilized cubic phase constitute key phonon modes that control the Na diffusion process in Na 3 PS 4 . We demonstrate how these strongly anharmonic phonon modes enable Na-ions to hop along the minimum energy pathways. Further, the quasi-elastic neutron scattering (QENS) measurements, supplemented with ab initio and machine-learned molecular dynamics simulations, probe the Na diffusivity and diffusion mechanism. These results offer detailed microscopic insights into the dynamic mechanism of fast Na diffusion and provide an avenue to search for further Na solid electrolytes.

42 ENGINEERING↗

Energy management of three-dimensional minimum-time intercept

A real-time computer algorithm to control and optimize aircraft flight profiles is described and applied to a three-dimensional minimum-time intercept mission. The proposed scheme has roots in two well known techniques: singular perturbations and neighboring-optimal guidance. Use of singular-perturbation ideas is made in terms of the assumed trajectory-family structure. A heading/energy family of prestored point-mass-model state-Euler solutions is used as the baseline in this scheme. The next step is to generate a near-optimal guidance law that will transfer the aircraft to the vicinity of this reference family. The control commands fed to the autopilot (bank angle and load factor) consist of the reference controls plus correction terms which are linear combinations of the altitude and path-angle deviations from reference values, weighted by a set of precalculated gains. In this respect the proposed scheme resembles neighboring-optimal guidance. However, in contrast to the neighboring-optimal guidance scheme, the reference control and state variables as well as the feedback gains are stored as functions of energy and heading in the present approach. Some numerical results comparing open-loop optimal and approximate feedback solutions are presented.

Kelley, H. J.↗

International Actions to Reduce Miscellaneous Electrical Loads Energy Consumption

Miscellaneous electric loads (MELs) research dates back over 30 years, with the earliest publications about MELs originating in the late 1980s. As the number and types of MELs have grown during the intervening decades, so has the body of minimum energy performance standards (MEPS) and regulations put in place to control what is now a significant energy end use in the residential and commercial sectors. In particular, these MEPS are designed to control off-mode, standby, and connected standby power consumption to prevent energy waste. Research on MELs focuses a great deal on analyzing the characteristics of MELs, approaches for measuring their consumption, and at a higher level what constitutes a MEL. Despite these advances, there have been few comparisons of different approaches to curtail MELs energy consumption across regulatory bodies of MELs—both between and within countries—to identify similarities, gaps, and opportunities for crafting common language and standards. This study provides an analysis of international MELs-related voluntary and mandatory MEPSs across 12 economies to address this gap. The analysis demonstrates that although economies may share the commitment to regulate the energy consumption of MELs, there still is no common language for framing MELs, nor is there a shared understanding for harmonizing MEPS for MELs.

Butzbaugh, Josh↗

International Actions to Reduce Miscellaneous Electrical Loads Energy Consumption

Miscellaneous electric loads (MELs) research dates back over thirty years, with the earliest publications on MELs originating in the late 1980s. As the number and types of MELs grew over the subsequent decades, so did the body of minimum energy performance standards (MEPS) and regulations put in place to control what is now an ever-growing source of energy consumption in the residential and commercial sectors. In particular, these MEPS are designed to control off-mode, standby, and connected standby power consumption to prevent energy waste. Research on MELs focuses a great deal on analyzing the characteristics of MELs, approaches for measuring their consumption, and at a higher level what constitutes a MEL. Despite these advances, there has yet to be a comparison of different approaches across regulatory bodies of MELs – both between and within countries – to identify similarities, gaps, and opportunities for crafting common language and testing procedures. This study provides an international analysis of MELs-related voluntary and mandatory MEPS across 12 economies to address this gap. The analysis demonstrates that even while economies may participate in shared commitments to regulated MELs energy consumption, there remains no common language for framing MELs, nor is there a shared understanding of updating aging test procedures used globally for verifying MELs-related MEPS.

Miscellaneous Electric Loads, MELs, Appliance and ↗

Optimization of Stability Constrained Geometrically Nonlinear Shallow Trusses Using an Arc Length Sparse Method with a Strain Energy Density Approach

A technique for the optimization of stability constrained geometrically nonlinear shallow trusses with snap through behavior is demonstrated using the arc length method and a strain energy density approach within a discrete finite element formulation. The optimization method uses an iterative scheme that evaluates the design variables' performance and then updates them according to a recursive formula controlled by the arc length method. A minimum weight design is achieved when a uniform nonlinear strain energy density is found in all members. This minimal condition places the design load just below the critical limit load causing snap through of the structure. The optimization scheme is programmed into a nonlinear finite element algorithm to find the large strain energy at critical limit loads. Examples of highly nonlinear trusses found in literature are presented to verify the method.

Hrinda, Glenn A.↗

Long and Winding Road to Higher Efficiency-The RTU Story: Preprint

Rooftop units (RTUs) and other packaged heating, ventilating, and air-conditioning (HVAC) equipment consume more than four quads of energy annually while conditioning more than 50% of the commercial building floor area in the United States. Historically, these systems have low operating efficiencies and receive infrequent maintenance. In addition, the market has a low first cost, run-to-failure, like-for-like replacement mentality and has been slow to adopt change. This paper explores the broad market transformation that has resulted in higher efficiencies and tremendous energy savings. Although there are many factors in this market transformation, this paper highlights: research behind advancements in components and controls; adoption of an operational efficiency metric; raising the bar for high efficiency with the RTU Challenge; market barriers overcome through the Advanced RTU Campaign; upstream and midstream incentive programs and HVAC distribution networks; alignment of the market efficiency drivers of ASHRAE Standard 90.1, federal minimum efficiency standards, the ENERGY STAR® program, and the Consortium for Energy Efficiency's (CEE's) efficiency tiers. Measures of the market transformation include more than 50% increase in RTU efficiencies, more than 1 billion kWh saved and 160,000 RTUs upgraded with high-efficiency measures by the Advanced RTU Campaign partners, large increases of high-efficiency RTUs purchased through incentive programs, and the largest energy savings from any federal minimum standards action. Although these results are impressive, the market transformation is just beginning, and there remain exciting opportunities for improvements in equipment efficiencies and improved operating performance with advanced controls and fault detection and diagnostics.

30 DIRECT ENERGY CONVERSION↗

A movable mass control system to detumble a disabled space vehicle

An internal autonomous control system to either completely detumble a spacecraft or lessen the tumbling motions until the rescue craft arrives is discussed. Such a device would become active upon loss of control. The development of a movable mass control system to convert the tumbling motions of a disabled vehicle into simple spin is presented. A simple spin state would greatly facilitate crew evacuation and final despinning by an external means. The system moves a control mass, according to a selected control law, in the acceleration environment created by the tumbling motion. By moving the mass properly, the rotational kinetic energy of the system may be increased or decreased creating simple spin states about the minimum or maximum moment of inertia axis, respectively. The control system is designed for the latter case due to its associated stability in the presence of perturbing forces.

Edwards, T. L.↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock/COVID-19: U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

ComStock is a DOE platform, with NREL as the lead developer, that models the U.S. commercial building stock using OpenStudio/EnergyPlus to perform physics-based building energy modeling simulations. The ASHRAE Epidemic Taskforce (ASHRAE-ETF) has released several COVID-19 mitigation strategies for commercial buildings. ComStock was used to analyze the impact of four strategies on the existing commercial building stock. These strategies are upgrading to MERV-13 filters, disabling demand control ventilation (DCV), increasing minimum outdoor air to 100%, and HVAC flushing mode operation. Results show the impact of each measure on energy consumption, electric consumption, gas consumption and peak electric.

30 DIRECT ENERGY CONVERSION↗

Fixed-range optimum trajectories for short-haul aircraft

An algorithm, based on the energy-state method, is derived for calculating optimum trajectories with a range constraint. The basis of the algorithm is the assumption that optimum trajectories consist of, at most, three segments: an increasing energy segment (climb); a constant energy segment (cruise); and a decreasing energy segment (descent). This assumption allows energy to be used as the independent variable in the increasing and decreasing energy segments, thereby eliminating the integration of a separate adjoint differential equation and simplifying the calculus of variations problem to one requiring only pointwise extremization of algebraic functions. The algorithm is used to compute minimum fuel, minimum time, and minimum direct-operating-cost trajectories, with range as a parameter, for an in-service CTOL aircraft and for an advanced STOL aircraft. For the CTOL aircraft and the minimum-fuel performance function, the optimum controls, consisting of air-speed and engine power setting, are continuous functions of the energy in both climb and descent as well as near the maximum or cruise energy. This is also true for the STOL aircraft except in the descent where at one energy level a nearly constant energy dive segment occurs, yielding a discontinuity in the airspeed at that energy. The reason for this segment appears to be the relatively high fuel flow at idle power of the engines used by this STOL aircraft. Use of a simplified trajectory which eliminates the dive increases the fuel consumption of the total descent trajectory by about 10 percent and the time to fly the descent by about 19 percent compared to the optimum.

Erzberger, H.↗

Wind Turbine Gearbox Failure Detection Through Cumulative Sum of Multivariate Time Series Data

The wind energy industry is continuously improving their operational and maintenance practice for reducing the levelized costs of energy. Anticipating failures in wind turbines enables early warnings and timely intervention, so that the costly corrective maintenance can be prevented to the largest extent possible. It also avoids production loss owing to prolonged unavailability. One critical element allowing early warning is the ability to accumulate small-magnitude symptoms resulting from the gradual degradation of wind turbine systems. Inspired by the cumulative sum control chart method, this study reports the development of a wind turbine failure detection method with such early warning capability. Specifically, the following key questions are addressed: what fault signals to accumulate, how long to accumulate, what offset to use, and how to set the alarm-triggering control limit. We apply the proposed approach to 2 years’ worth of Supervisory Control and Data Acquisition data recorded from five wind turbines. We focus our analysis on gearbox failure detection, in which the proposed approach demonstrates its ability to anticipate failure events with a good lead time.

17 WIND ENERGY↗

Advanced control sequences and FDD technology. Just shiny objects, or ready for scale?

Innovations in commercial building control sequences (ASHRAE guideline 36) and fault detection and diagnostics (FDD) technology have the potential to transform existing building operational efficiency by realizing whole-building level savings on the order of 15% and higher. However, several technical and market barriers related to up-front estimation of achievable savings, verifying implementation, and ensuring persistence are slowing down their adoption as a core offering through diverse owner-funded initiatives and rate-payer funded programs. This paper describes a suite of solutions to overcome these barriers to program delivery of advanced HVAC controls integrated with FDD energy management and information system (EMIS) technology. First, the Guideline 36 conformance test offers an automated method to confirm correct sequence implementation by the manufacturer, before field deployment. A successful test of a controller was conducted using a new manufacturer-independent hardware-in-the-loop testbed demonstrating the viability and scalability of this approach. Second, the Guideline 36 energy savings calculator uses modeling paired with high-level user inputs to estimate building-specific savings potential, target cost effective implementation and minimize uncertainty. Initial results indicate the baseline control sequences significantly impact energy savings, however, as much as 50% savings may be possible for the worst-case baseline scenario. Third, a functional specification provides minimum recommended EMIS-FDD capabilities, and best practices to integrate the technology into organizational practice and ensure that advanced control sequences provide persistent savings.

Pritoni, Marco↗

Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

Benner, S. M.↗

Suppressing metal corrosion through identification of optimal crystallographic plane for Zn batteries

Direct use of metals as battery anodes could significantly boost the energy density, but suffers from limited cycling. To make the batteries more sustainable, one strategy is mitigating the propensity for metals to form random morphology during plating through orientation regulation, e.g., hexagonal Zn platelets locked horizontally by epitaxial electrodeposition or vertically aligned through Zn/electrolyte interface modulation. Current strategies center around obtaining (002) faceted deposition due to its minimum surface energy. Here, benefiting from the capability of preparing a library of faceted monocrystalline Zn anodes and controlling the orientation of Zn platelet deposits, we challenge this conventional belief. We show that while monocrystalline (002) faceted Zn electrode with horizontal epitaxy indeed promises the highest critical current density, the (100) faceted electrode with vertically aligned deposits is the most important one in suppressing Zn metal corrosion and promising the best reversibility. Such uniqueness results from the lowest electrochemical surface area of (100) faceted electrode, which intrinsically builds upon the surface atom diffusion barrier and the orientation of the pallets. These new findings based on monocrystalline anodes advance the fundamental understanding of electrodeposition process for sustainable metal batteries and provide a paradigm to explore the processing–structure–property relationships of metal electrodes.

25 ENERGY STORAGE↗

Energy landscapes from cryo-EM snapshots: a benchmarking study

Abstract Biomolecules undergo continuous conformational motions, a subset of which are functionally relevant. Understanding, and ultimately controlling biomolecular function are predicated on the ability to map continuous conformational motions, and identify the functionally relevant conformational trajectories. For equilibrium and near-equilibrium processes, function proceeds along minimum-energy pathways on one or more energy landscapes, because higher-energy conformations are only weakly occupied. With the growing interest in identifying functional trajectories, the need for reliable mapping of energy landscapes has become paramount. In response, various data-analytical tools for determining structural variability are emerging. A key question concerns the veracity with which each data-analytical tool can extract functionally relevant conformational trajectories from a collection of single-particle cryo-EM snapshots. Using synthetic data as an independently known ground truth, we benchmark the ability of four leading algorithms to determine biomolecular energy landscapes and identify the functionally relevant conformational paths on these landscapes. Such benchmarking is essential for systematic progress toward atomic-level movies of continuous biomolecular function.

59 BASIC BIOLOGICAL SCIENCES↗

Information and Collaboration Levels in Vehicular Strings: A Comparative Study

The potential safety, productivity, and energy benefits of automated vehicles have driven a surge of research interest in their algorithms. Even within single-lane driving, control engineers now have a profusion of approaches available to them. Algorithm classes include classical controllers, receding horizon controllers, and constrained eco-driving formulae based on Pontryagin’s Minimum Principle. Differing connectivity architectures and collaboration levels further differentiate algorithms from one another. This study evaluated six controllers in two drive cycle-based scenarios using an electric powertrain model for energy analysis. Individual-vehicle and string performance were examined, including string stability and length. Algorithms with greater access to information generally performed best. Although collaboration affected energy use only slightly, it made a greater impact on string length.

Dollar, R. Austin↗