Low-loss single-photon NbN microwave resonators on Si

We present coplanar waveguide (CPW) microwave resonators with exceptionally low loss produced from NbN sputtered on Si. The NbN films are deposited with a modest RF substrate bias during reactive DC magnetron sputtering at a substrate temperature of 250 °C and can achieve a critical temperature as high as 15 K depending on the N2 flow rate. We measure the internal quality factors (Qi) of two such resonators at high-powers near saturation and report high-power quality factors in excess of 1.2 × 106 at 200 mK and 3.5 × 105 at 2 K. We also measure the temperature-dependent frequency shift at high power levels and the quality factor at single-photon power levels. From these measurements, we find a low-power (average photon number less than one) Qi value of 4.2 × 105 at 200 mK, which is consistent with a system limited by two-level-system loss.

Carter, Faustin W. (ORCID:0000000212363517)↗

EVOLUTION OF THE COSMIC MICROWAVE BACKGROUND POWER SPECTRUM ACROSS WILKINSON MICROWAVE ANISOTROPY PROBE DATA RELEASES: A NONPARAMETRIC ANALYSIS

Using a nonparametric function estimation methodology, we present a comparative analysis of the Wilkinson Microwave Anisotropy Probe (WMAP) 1-, 3-, 5-, and 7-year data releases for the cosmic microwave background (CMB) angular power spectrum with respect to the following key questions. (1) How well is the power spectrum determined by the data alone? (2) How well is the {Lambda}CDM model supported by a model-independent, data-driven analysis? (3) What are the realistic uncertainties on peak/dip locations and heights? Our results show that the height of the power spectrum is well determined by data alone for multipole l approximately less than 546 (1-year), 667 (3-year), 804 (5-year), and 842 (7-year data). We show that parametric fits based on the {Lambda}CDM model are remarkably close to our nonparametric fits in l-regions where data are sufficiently precise. In contrast, the power spectrum for an H{Lambda}CDM model is progressively pushed away from our nonparametric fit as data quality improves with successive data realizations, suggesting incompatibility of this particular cosmological model with respect to the WMAP data sets. We present uncertainties on peak/dip locations and heights at the 95% (2{sigma}) level of confidence and show how these uncertainties translate into hyperbolic 'bands' on the acoustic scale (l{sub A} ) and peak shift ({phi}{sub m}) parameters. Based on the confidence set for the 7-year data, we argue that the low-l upturn in the CMB power spectrum cannot be ruled out at any confidence level in excess of about 10% ( Almost-Equal-To 0.12{sigma}). Additional outcomes of this work are a numerical formulation for minimization of a noise-weighted risk function subject to monotonicity constraints, a prescription for obtaining nonparametric fits that are closer to cosmological expectations on smoothness, and a method for sampling cosmologically meaningful power spectrum variations from the confidence set of a nonparametric fit.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on cosmology from the cosmic microwave background power spectrum of the 2500 deg{sup 2} SPT-SZ survey

We explore extensions to the ΛCDM cosmology using measurements of the cosmic microwave background (CMB) from the recent SPT-SZ survey, along with data from WMAP7 and measurements of H {sub 0} and baryon acoustic oscillation (BAO). We check for consistency within ΛCDM between these data sets, and find some tension. The CMB alone gives weak support to physics beyond ΛCDM, due to a slight trend relative to ΛCDM of decreasing power toward smaller angular scales. While it may be due to statistical fluctuation, this trend could also be explained by several extensions. We consider running of the primordial spectral index (dn{sub s} /dln k), as well as two extensions that modify the damping tail power (the primordial helium abundance Y{sub p} and the effective number of neutrino species N {sub eff}) and one that modifies the large-scale power due to the integrated Sachs-Wolfe effect (the sum of neutrino masses ∑m {sub ν}). These extensions have similar observational consequences and are partially degenerate when considered simultaneously. Of the six one-parameter extensions considered, we find CMB to have the largest preference for dn{sub s} /dln k with –0.046 < dn{sub s} /dln k < –0.003 at 95% confidence, which strengthens to a 2.7σ indication of dn{sub s} /dln k < 0 from CMB+BAO+H {sub 0}. Detectable dn{sub s} /dln k ≠ 0 is difficult to explain in the context of single-field, slow-roll inflation models. We find N {sub eff} = 3.62 ± 0.48 for the CMB, which tightens to N {sub eff} = 3.71 ± 0.35 from CMB+BAO+H {sub 0}. Larger values of N {sub eff} relieve the mild tension between CMB, BAO, and H {sub 0}. When the Sunyaev-Zel'dovich selected galaxy cluster abundances (SPT{sub CL}) data are also included, we obtain N {sub eff} = 3.29 ± 0.31. Allowing for ∑m {sub ν} gives a 3.0σ detection of ∑m {sub ν} > 0 from CMB+BAO+H {sub 0} +SPT{sub CL}. The median value is (0.32 ± 0.11) eV, a factor of six above the lower bound set by neutrino oscillation observations. All data sets except H {sub 0} show some preference for massive neutrinos; data combinations including H {sub 0} favor nonzero masses only if BAO data are also included. We also constrain the two-parameter extensions N {sub eff} + ∑m {sub ν} and N {sub eff} + Y{sub p} to explore constraints on additional light species and big bang nucleosynthesis, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

A MEASUREMENT OF SECONDARY COSMIC MICROWAVE BACKGROUND ANISOTROPIES FROM THE 2500 SQUARE-DEGREE SPT-SZ SURVEY

We present measurements of secondary cosmic microwave background (CMB) anisotropies and cosmic infrared background (CIB) fluctuations using data from the South Pole Telescope (SPT) covering the complete 2540 deg{sup 2} SPT-SZ survey area. Data in the three SPT-SZ frequency bands centered at 95, 150, and 220 GHz, are used to produce six angular power spectra (three single-frequency auto-spectra and three cross-spectra) covering the multipole range 2000 < ℓ < 11, 000 (angular scales 5' ≳ θ ≳ 1'). These are the most precise measurements of the angular power spectra at ℓ > 2500 at these frequencies. The main contributors to the power spectra at these angular scales and frequencies are the primary CMB, CIB, thermal and kinematic Sunyaev-Zel'dovich effects (tSZ and kSZ), and radio galaxies. We include a constraint on the tSZ power from a measurement of the tSZ bispectrum from 800 deg{sup 2} of the SPT-SZ survey. We measure the tSZ power at 143 GHz to be D{sub 3000}{sup tSZ}=4.08{sub −0.67}{sup +0.58} μK{sup 2} and the kSZ power to be D{sub 3000}{sup kSZ}=2.9±1.3 μK{sup 2}. The data prefer positive kSZ power at 98.1% CL. We measure a correlation coefficient of ξ=0.113{sub −0.054}{sup +0.057} between sources of tSZ and CIB power, with ξ < 0 disfavored at a confidence level of 99.0%. The constraint on kSZ power can be interpreted as an upper limit on the duration of reionization. When the post-reionization homogeneous kSZ signal is accounted for, we find an upper limit on the duration Δz < 5.4 at 95% CL.

79 ASTRONOMY AND ASTROPHYSICS↗

Isotropy-violation diagnostics for B -mode polarization foregrounds to the Cosmic Microwave Background

Isotropy-violation statistics can highlight polarized galactic foregrounds that contaminate primordial B -modes in the Cosmic Microwave Background (CMB). We propose a particular isotropy-violation test and apply it to polarized Planck 353 GHz data, constructing a map that indicates B -mode foreground dust power over the sky. We build our main isotropy test in harmonic space via the bipolar spherical harmonic basis, and our method helps us to identify the least-contaminated directions. By this measure, there are regions of low foreground in and around the BICEP field, near the South Galactic Pole, and in the Northern Galactic Hemisphere. There is also a possible foreground feature in the BICEP field. In our study, we compare our results to those based on the local power spectrum, which is computed on discs using a version of the method of Planck Int. XXX (2016). The discs method is closely related to our isotropy-violation diagnostic. We pay special care to the treatment of noise, including chance correlations with the foregrounds. Currently we use our isotropy tool to assess the cleanest portions of the sky, but in the future such methods will allow isotropy-based null tests for foreground contamination in maps purported to measure primordial B -modes, particularly in cases of limited frequency coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic microwave background constraints on secret interactions among sterile neutrinos

Secret contact interactions among eV sterile neutrinos, mediated by a massive gauge boson X (with M X &NestedLessLess; M W ), and characterized by a gauge coupling gX, have been proposed as a mean to reconcile cosmological observations and short-baseline laboratory anomalies. We constrain this scenario using the latest Planck data on Cosmic Microwave Background anisotropies, and measurements of baryon acoustic oscillations (BAO). We consistently include the effect of secret interactions on cosmological perturbations, namely the increased density and pressure fluctuations in the neutrino fluid, and still find a severe tension between the secret interaction framework and cosmology. In fact, taking into account neutrino scattering via secret interactions, we derive our own mass bound on sterile neutrinos and find (at 95 % CL) m s < 0.82 eV or m s < 0.29 eV from Planck alone or in combination with BAO, respectively. These limits confirm the discrepancy with the laboratory anomalies. Moreover, we constrain, in the limit of contact interaction, the effective strength G X to be < 2.8 (2.0) × 10 10 G F from Planck (Planck+BAO). This result, together with the mass bound, strongly disfavours the region with M X ~ 0.1 MeV and relatively large coupling g X ~ 10 -1 , previously indicated as a possible solution to the small scale dark matter problem.

79 ASTRONOMY AND ASTROPHYSICS↗

Foreground-Immune Cosmic Microwave Background Lensing with Shear-Only Reconstruction

Cosmic microwave background (CMB) lensing from current and upcoming wide-field CMB experiments such as AdvACT, SPT-3G and Simons Observatory relies heavily on temperature (versus polarization). In this regime, foreground contamination to the temperature map produces significant lensing biases, which cannot be fully controlled by multifrequency component separation, masking, or bias hardening. Here in this Letter, we split the standard CMB lensing quadratic estimator into a new set of optimal “multipole” estimators. On large scales, these multipole estimators reduce to the known magnification and shear estimators, and a new shear B-mode estimator. We leverage the different symmetries of the lensed CMB and extragalactic foregrounds to argue that the shear-only estimator should be approximately immune to extragalactic foregrounds. We build a new method to compute, separately and without noise, the primary, secondary, and trispectrum biases to CMB lensing from foreground simulations. Using this method, we demonstrate that the shear estimator is, indeed, insensitive to extragalactic foregrounds, even when applied to a single-frequency temperature map contaminated with cosmic infrared background, thermal Sunyaev-Zel’dovich, kinematic Sunyaev-Zel’dovich, and radio point sources. This dramatic reduction in foreground biases allows us to include higher temperature multipoles than with the standard quadratic estimator, thus, increasing the total lensing signal-to-noise ratio beyond the quadratic estimator. In addition, magnification-only and shear B-mode estimators provide useful diagnostics for potential residuals.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband anti-reflective coatings for cosmic microwave background experiments

The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to ~700 mm diameter) and lenslets (~5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetra uoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cavity electro-optics in thin-film lithium niobate for efficient microwave-to-optical transduction

Linking superconducting quantum devices to optical fibers via microwave-optical quantum transducers may enable large-scale quantum networks. For this application, transducers based on the Pockels electro-optic (EO) effect are promising for their direct conversion mechanism, high bandwidth, and potential for low-noise operation. However, previously demonstrated EO transducers require large optical pump power to overcome weak EO coupling and reach high efficiency. Here, we create an EO transducer in thin-film lithium niobate, a platform that provides low optical loss and strong EO coupling. We demonstrate on-chip transduction efficiencies of up to and of optical pump power. The transduction efficiency can be improved by further reducing the microwave resonator’s piezoelectric coupling to acoustic modes, increasing the optical resonator quality factor to previously demonstrated levels, and changing the electrode geometry for enhanced EO coupling. We expect that with further development, EO transducers in thin-film lithium niobate can achieve near-unity efficiency with low optical pump power.

Holzgrafe, Jeffrey (ORCID:0000000160121451)↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Measurement of the Cosmic Microwave Background B-mode Polarization Power Spectrum at Subdegree Scales from Two Years of polarbear Data

We report an improved measurement of the cosmic microwave background B-mode polarization power spectrum with the Polarbear experiment at 150 GHz. By adding new data collected during the second season of observations (2013–2014) to re-analyzed data from the first season (2012–2013), we have reduced twofold the band-power uncertainties. The band powers are reported over angular multipoles 500⩽ℓ⩽2100, where the dominant B-mode signal is expected to be due to the gravitational lensing of E-modes. We reject the null hypothesis of no B-mode polarization at a confidence of 3.1σ including both statistical and systematic uncertainties. We test the consistency of the measured B-modes with the Λ Cold Dark Matter (ΛCDM) framework by fitting for a single lensing amplitude parameter A {sub L} relative to the Planck 2015 best-fit model prediction. We obtain A{sub L}=0.60{sub −0.24}{sup +0.26}(stat){sub −0.04}{sup +0.00}(inst) ± 0.14(foreground) ± 0.04(multi), where A{sub L}=1 is the fiducial ΛCDM value.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the Cross-spectra of the Cosmic Infrared and Microwave Backgrounds from 95 to 1200 GHz

We present measurements of the power spectra of cosmic infrared background (CIB) and cosmic microwave background (CMB) fluctuations in six frequency bands. Maps at the lower three frequency bands, 95, 150, and 220 GHz (3330, 2000, and 1360 μm) are from the South Pole Telescope, while the upper three frequency bands, 600, 857, and 1200 GHz (500, 350, 250 μm) are observed with Herschel/SPIRE. From these data, we produce 21 angular power spectra (6 auto- and 15 cross-frequency) spanning the multipole range 600 ≤ ℓ ≤ 11,000. Our measurements are the first to cross-correlate measurements near the peak of the CIB spectrum with maps at 95 GHz, complementing and extending the measurements from Planck Collaboration et al. at 143–857 GHz. The observed fluctuations originate largely from clustered, infrared-emitting, dusty star-forming galaxies, the CMB, and to a lesser extent radio galaxies, active galactic nuclei, and the Sunyaev–Zel’dovich effect.

cosmic background radiation↗

Microwave radiation hazards around large microwave antenna.

The microwave radiation hazards associated with the use of large antennas become increasingly more dangerous to personnel as the transmitters go to ever higher powers. The near-field area is of the greatest concern. It has spill over from subreflector and reflections from nearby objects. Centimeter waves meeting in phase will reinforce each other and create hot spots of microwave energy. This has been measured in front of and around several 26-meter antennas. Hot spots have been found and are going to be the determining factor in delineating safe areas for personnel to work. Better techniques and instruments to measure these fields are needed for the evaluation of hazard areas.

Klascius, A.↗

Microwave integrated circuit radiometer front-ends for the Push Broom Microwave Radiometer

Microwave integrated circuit front-ends for the L-band, S-band and C-band stepped frequency null-balanced noise-injection Dicke-switched radiometer to be installed in the NASA Langley airborne prototype Push Broom Microwave Radiometer (PBMR) are described. These front-ends were developed for the fixed frequency of 1.413 GHz and the variable frequencies of 1.8-2.8 GHz and 3.8-5.8 GHz. Measurements of the noise temperature of these units were made at 55.8 C, and the results of these tests are given. While the overall performance was reasonable, improvements need to be made in circuit losses and noise temperatures, which in the case of the C-band were from 1000 to 1850 K instead of the 500 K specified. Further development of the prototypes is underway to improve performance and extend the frequency range.

Harrington, R. F.↗

Sea ice effective microwave emissivities from satellite passive microwave and infrared observations

Near-simultaneous images from the temperature-humidity IR radiometer and dual-polarization scanning multichannel microwave radiometer of the Nimbus 7 satellite are used to investigate microwave sea ice emissivities on a global scale. Emissivities in several Arctic region study areas are found to be approximately constant during a nine-month pereiod covering the fall, winter and spring months, in the cases of both first-year and multiyear ice. During the onset of summer, emissivity increases of about 30 percent are observed at 37 GHz in multiyear ice. A multichannel cluster analysis over very large study areas during winter indicates considerable variability in emissivities of consolidated ice clusters at 37 GHz, and only 1/3 as much variability at 18 GHz. If the variability within each cluster is quantified and taken into account by means of multispectral analysis, data on ice thickness and surface characteristics may also be obtained.

Comiso, J. C.↗

Utilization of active microwave roughness measurements to improve passive microwave soil moisture estimates over bare soils

Multisensor aircraft data were used to establish the potential of the active microwave sensor response to be used to compensate for roughness in the passive microwave sensor's response to soil moisture. Only bare fields were used. It is found that the L-band radiometer's capability to estimate soil moisture significantly improves when surface roughness is accounted for with the scatterometers.

Theis, S. W.↗