Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A cavity type absorption cell for double resonance microwave spectroscopy.

Description of an experimental dual resonant cavity absorption cell for observing microwave spectroscopic double-resonance effects. The device is composed of two Fabry-Perot interferometers excited by independent microwave sources and mounted at right angles in a suitable vacuum enclosure. The pumping transition is modulated by one source and the modulation induced on the rf absorption in the orthogonal cavity is detected.

Lee, M. C.↗

Formaldehyde monitor for automobile exhausts

Device makes use of microwave spectral absorption in low-Q resonant Stark cell, and indications are that ultimate sensitivity of instrument is within 100 parts per billion of formaldehyde. Microwave source is very small and requires only six-volt dc bias for operation. Coarse tuning is accomplished mechanically and fine tuning by adjusting dc-bias voltage.

Easley, W. C.↗

Remote sensing of sea state by analysis of backscattered microwave phase fluctuations

The relative phase of a normally incident microwave signal scattered off the sea surface is a random function of space and time. The statistics of these random phase fluctuations contain information about the wave-height statistics. This study demonstrates that the wave-height spectra can be deduced directly in terms of the spectra of the phase fluctuations without recourse to inversion techniques even when surface roughness exceeds many wavelengths of the incident signal. In the particular case of a nadir-directed satellite-mounted microwave source operating in the backscatter mode, the wave-height and phase spatial spectra are proportional with a constant proportionality of (2k0) squared, where k0 is the wavenumber of the scattered signal.

Clifford, S. F.↗

Design of an extended-range, three-wavelength distance-measuring instrument

The paper describes an extension of current multiwavelength electromagnetic distance measurement (EDM) techniques which should allow the range of multiwavelength measurements to be extended to approximately 50 km. The basic modification needed is the replacement of the retroreflector commonly used by an active station containing lasers and a microwave source. Because the system will always be operated as a full three-wave-length instrument, accuracies of about 5 x 10 to the -8th at 50 km should be obtainable on a routine basis under reasonably clear weather conditions.

Moody, S. E.↗

SPS solid state antenna power combiner

A concept for a solar power satellite antenna power combiner which utilizes solid state dc-rf converters is described. To avoid the power combining losses associated with circuit hybrids it is proposed that the power from multiple solid state amplifiers be combined by direct coupling of each amplifier's output to the radiating antenna structure. The selected power-combining antenna consists of a printed (metalized) microstrip circuit on a ceramic type dielectric substrate which is backed by a shallow lightweight aluminum cavity which sums the power of four microwave sources. The antenna behaves like two one-half wavelength slot-line antennas coupled together via their common cavity structure. A significant feature of the antenna configuration selected is that the radiated energy is summed to yield a single radiated output phase which represents the average insertion phase of the four power amplifiers. This energy may be sampled and, by comparison with the input signal, one can phase error correct to maintain the insertion phase of all solid state power combining modules at exactly the same value. This insures that the insertion phase of each SPS power combining antenna module is identical. An experiment verification program is described.

Fitzsimmons, G. W.↗

Snow Electromagnetic Measurements

An electromagnetic system is described for measuring the dielectric constant and attenuation of snow samples in the frequency range of 4 to 12 GHz. System components consists of a swept-frequency source, microwave horns, network analyzer, and XY plotter. The procedure for calibrating the effect of wetness on the snow properties is described. Equations are given that express the experimentally determined relation between attenuation per unit length and volume percent wetness at any frequency between 4 and 12 GHz. permittivity can be calculated from the snow density, attenuation per unit length, and frequency. Some applications of the techniques are described such as runoff forecasting from mountain snowpacks.

Linlor, W. I.↗

Interpretation of microwave active region structures using SMM soft X-ray observations

A new kind of sunspot-associated microwave source was detected by Alissandrakis and Kundu (1982). The observed emission came predominantly from a ring structure with a size between that of the umbra and the penumbra. It was thought that the newly discovered structure could be the product of the low gyroresonance opacity when the angle between the magnetic field and the line of sight is close to zero. The present investigation has the objective to study the roles played by the geometrical effect of gyroresonance absorption and by the low-temperature flux tubes above the relevant sunspot, taking into account 6 cm observations made with the aid of a radio telescope and X-ray observations conducted with the X-ray Polychromator (XRPO on the Solar Maximum Mission) (SMM) satellite.

Strong, K. T.↗

Signatures of the coalescence instability in solar flares

Double sub-peak structures in the quasi periodic oscillations in the time profiles of solar flares in 1980 and 1982 are discussed. Computer simulations of the coalescence instability of two current loops agree with observations of the (widely differing) flares. The simultaneous accelerations of electrons and ions, and the double sub-peak structure in quasi periodic pulses are well explained. The double sub-peak structure is more pronounced when the currents in the two loops are sufficient for fast coalescence to occur. This corresponds to the 1980 flare. When the currents are insufficient for fast coalescence, the double sub-peak structure is less pronounced, as in the 1982 flare. Observations suggest the collision of the two microwave sources for the 1982 event. It is argued that this mechanism is a plausible particle acceleration mechanism in solar flares.

Nakajima, H.↗

High resolution spectroscopy in the microwave and far infrared

High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

Pickett, Herbert M.↗

Optical and microwave detection using Bi-Sr-Ca-Cu-O thin films

Recent progress at the Johns Hopkins University Applied Physics Laboratory (JHU/APL) in the development of optical and microwave detectors using high temperature superconducting thin films is described. Several objectives of this work have been accomplished, including: deposition of Bi-Sr-Ca-Cu-O thin films by laser abation processing (LAP); development of thin film patterning techniques, including in situ masking, wet chemical etching and laser patterning; measurements of bolometric and non-bolometric signatures in patterned Bi-Sr-Ca-Cu-O films using optical and microwave sources, respectively; analysis and design of an optimized bolometer through computer simulation, and investigation of its use in a Fourier transform spectrometer. The focus here is primarily on results from the measurement of the bolometric and non-bolometric response.

Grabow, B. E.↗

Multifrequency observations of a solar microwave burst with two-dimensional spatial resolution

Frequency-agile interferometry observations using three baselines and the technique of frequency synthesis were used to obtain two-dimensional positions of multiple microwave sources at several frequency ranges in a solar flare. Source size and brightness temperature spectra were obtained near the peak of the burst. The size spectrum shows that the source size decreases rapidly with increasing frequency, but the brightness temperature spectrum can be well-fitted by gyrosynchrotron emission from a nonthermal distribution of electrons with power-law index of 4.8. The spatial structure of the burst showed several characteristics in common with primary/secondary bursts discussed by Nakajima et al. (1985). A source of coherent plasma emission at low frequencies is found near the secondary gyrosynchrotron source, associated with the leader spots of the active region.

Gary, Dale E.↗

Optical and microwave detection using Bi-Sr-Ca-Cu-O thin films

Recent progress at the Johns Hopkins University Applied Physics Laboratory (JHU/APL) in the development of optical and microwave detectors using high temperature superconducting thin films is described. Several objectives of this work have been accomplished, including: deposition of Bi-Sr-Ca-Cu-O thin films by laser abation processing (LAP); development of thin film patterning techniques, including in situ masking, wet chemical etching, and laser patterning; measurements of bolometric and non-bolometric signatures in patterned Bi-Sr-Ca-Cu-O films using optical and microwave sources, respectively; analysis and design of an optimized bolometer through computer simulation; and investigation of its use in a Fourier transform spectrometer. The focus here is primarily on results from the measurement of the bolometric and non-bolometric response.

Grabow, B. E.↗

Fiber-Optic Discriminator Stabilizes Microwave Oscillator

New fiber-optic delay line discriminator enables stabilization of oscillators directly at microwave output frequency, eliminating need for frequency multiplication. Discriminator is wide-band device, capable of stabilizing outputs of frequency-agile microwave sources over multigigahertz tuning ranges. Use of advanced fiber-optic delay line with wider bandwidth and low noise predicted to yield corresponding improvements in phase-noise performance.

Logan, Ronald T., Jr.↗

Microwave spectroscopy of the active sun

In studies of solar active regions and bursts, the ability to obtain spatially resolved radio spectra (brightness temperature spectra) opens a whole new range of possibilities for study of the solar corona. For active regions, two-dimensional maps of brightness temperature over a wide range of frequencies allows one to determine temperature, column density, and magnetic field strength over the entire region in a straightforward, unambiguous way. For flares, the time-dependent electron energy distribution, number of accelerated electrons, and magnetic field strength and direction can be found. In practice, obtaining complete radio images at a large number of frequencies is a significant technical challenge, especially while keeping costs down. Our instrument at Owens Valley Radio Observatory provided the starting point for a modest attempt at meeting this goal. We proposed to build three additional, very low-cost 2-m antennas which, when combined with our existing two 27-m dishes, expands the array to 5 elements. This modest increase in number of solar dedicated antennas, from 2 to 5, increases our maximum number of physical baselines from 1 to 10 and allows the instrument to do true imaging of solar microwave sources, both bursts and active regions. Combined with the technique of frequency synthesis, the new array has up to 450 effective baselines, giving imaging capability that approaches that of a sub-arrayed VLA. The prototype antenna design was finalized and the antenna was put into operation in Nov. 1989.

Hurford, Gordon↗

A nonequilibrium model for a moderate pressure hydrogen microwave discharge plasma

This document describes a simple nonequilibrium energy exchange and chemical reaction model to be used in a computational fluid dynamics calculation for a hydrogen plasma excited by microwaves. The model takes into account the exchange between the electrons and excited states of molecular and atomic hydrogen. Specifically, electron-translation, electron-vibration, translation-vibration, ionization, and dissociation are included. The model assumes three temperatures, translational/rotational, vibrational, and electron, each describing a Boltzmann distribution for its respective energy mode. The energy from the microwave source is coupled to the energy equation via a source term that depends on an effective electric field which must be calculated outside the present model. This electric field must be found by coupling the results of the fluid dynamics and kinetics solution with a solution to Maxwell's equations that includes the effects of the plasma permittivity. The solution to Maxwell's equations is not within the scope of this present paper.

Scott, Carl D.↗

The impulsive phase of a large solar limb flare of June 20, 1989

On June 20, 1989 we observed in H-alpha the impulsive phase of a 3B/X 1.6 limb flare with high temporal resolution. Line profiles have been acquired every 2.3 s with an imaging spectrograph. During the eruption of a filament, we observed in H-alpha a moving plasma blob from what we believe to be a second loop which correlated spatially and temporally with a microwave source at 1.4 GHz observed by VLA. A magnetodynamic model is used to understand the development of the moving plasma blob.

Graeter, Martin↗

Imaging spectroscopy of solar microwave radiation. 1: Flaring emission

We present observations of an impulsive microwave burst on the Sun with both high spatial and spectral resolution, made with the Solar Array at the Owens Valley Radio Observatory (OVRO). We used the measured brightness temperature spectrum to infer the emission process responsible for each microwave source, and to derive physical conditions in the source region. We confimed our predictions using soft X-ray measurements from Geostationary Operational Environmental Satellite (GOES), soft X-ray images from Yohkoh, and H-alpha flare images together with sunspots and magnetogram images from the Big Bear Solar Observatory.

Lim, Jeremy↗

Pulse Power Capability Of High Energy Density Capacitors Based on a New Dielectric Material

A new dielectric composite consisting of a polymer coated onto a high-density metallized Kraft has been developed for application in high energy density pulse power capacitors. The polymer coating is custom formulated for high dielectric constant and strength with minimum dielectric losses. The composite can be wound and processed using conventional wound film capacitor manufacturing equipment. This new system has the potential to achieve 2 to 3 J/cu cm whole capacitor energy density at voltage levels above 3.0 kV, and can maintain its mechanical properties to temperatures above 150 C. The technical and manufacturing development of the composite material and fabrication into capacitors are summarized in this paper. Energy discharge testing, including capacitance and charge-discharge efficiency at normal and elevated temperatures, as well as DC life testing were performed on capacitors manufactured using this material. TPL (Albuquerque, NM) has developed the material and Aerovox (New Bedford, MA) has used the material to build and test actual capacitors. The results of the testing will focus on pulse power applications specifically those found in electro-magnetic armor and guns, high power microwave sources and defibrillators.

Winsor, Paul↗