Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microtomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Study of liquid gallium as a function of pressure and temperature using synchrotron x-ray microtomography and x-ray diffraction

The volume change of liquid and solid gallium has been studied as a function of pressure and temperature up to 3.02 GPa at 300 K and up to 3.63 GPa at 330 K using synchrotron x-ray microtomography combined with energy dispersive x-ray diffraction techniques. Two sets of directly measured P-V data at 300 K and 330 K were obtained from 3D tomography reconstruction data, and the corresponding isothermal bulk moduli were determined as 23.6 (0.5) GPa and 24.6 (0.4) GPa, respectively. The existence of a liquid-liquid phase transition region is proposed based on the abnormal compressibility of Ga melt at about 2.44 GPa and 330 K conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography

An experimental study about the anisotropic wetting behavior of a surface patterned with parallel grooves is presented as an application example of a novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography. Shape of glycerin droplets on such surface is investigated by X-ray micro computed tomography (microCT) acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution. The reconstructed drop volumes enable to estimate the exact volumes of the drops, their base contours, and 3D static contact angles, based on true cross-sections of the drop-surface couple. Droplet base contours are compared to approximate geometrical contour shapes proposed in the literature. Contact angles along slices parallel and perpendicular to the grooves direction are compared with each other. The effect of the sessile drop volume on the wetting behavior is discussed. The proposed technique, which is applicable for any structured surface, enables the direct measure of Wenzel ratio based on the microCT scan in the wetted region usually inapproachable by any others. Comparisons with simplified models are presented and congruence of results with respect to the minimum resolution needed is evaluated and commented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent progress of hard x-ray imaging microscopy and microtomography at BL37XU of SPring-8

A hard x-ray imaging microscopy and microtomography system is now being developed at the beamline 37XU of SPring-8. In the latest improvement, a spatial resolution of about 50 nm is achieved in two-dimensional imaging at 6 keV x-ray energy using a Fresnel zone plate objective with an outermost zone width of 35 nm. In the tomographic measurement, a spatial resolution of about 100 nm is achieved at 8 keV using an x-ray guide tube condenser optic and a Fresnel zone plate objective with an outermost zone width of 50 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of ∼1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous high-pressure behavior of amorphous selenium from synchrotron x-ray diffraction and microtomography.

The high-pressure behavior of amorphous selenium has been investigated with time-resolved diamond anvil cell synchrotron x-ray diffraction and computed microtomography techniques. A two-step dynamic crystallization process is observed in which the monoclinic phase crystallized from the amorphous selenium and gradually converted to the trigonal phase, thereby explaining previously observed anomalous changes in electrical conductivity of the material under pressure. The crystallization of this elemental system involves local topological fluctuations and results in an unusual pressure-induced volume expansion. The metastability of the phases involved in the transition accounts for this phenomenon. The results demonstrate the use of pressure to control and directly monitor the relative densities and energetics of phases to create new phases from highly metastable states. The microtomographic technique developed here represents a method for determination of the equations of state of amorphous materials at extreme pressures and temperatures.

43 PARTICLE ACCELERATORS↗

Three-dimensional reconstruction of statistically optimal unit cells of polydisperse particulate composites from microtomography

In this paper, we present a systematic approach for characterization and reconstruction of statistically optimal representative unit cells of polydisperse particulate composites. Microtomography is used to gather rich three-dimensional data of a packed glass bead system. First-, second-, and third-order probability functions are used to characterize the morphology of the material, and the parallel augmented simulated annealing algorithm is employed for reconstruction of the statistically equivalent medium. Both the fully resolved probability spectrum and the geometrically exact particle shapes are considered in this study, rendering the optimization problem multidimensional with a highly complex objective function. A ten-phase particulate composite composed of packed glass beads in a cylindrical specimen is investigated, and a unit cell is reconstructed on massively parallel computers. Further, rigorous error analysis of the statistical descriptors (probability functions) is presented and a detailed comparison between statistics of the voxel-derived pack and the representative cell is made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact and flexible induction furnace for in situ X-ray microradiograhy and computed microtomography at Elettra: design, characterization and first tests

A compact and versatile induction furnace for in situ high-resolution synchrotron and laboratory hard X-ray microradiography and computed microtomography is described. The furnace can operate from 773 to 1723 K. Its programmable controller enables the user to specify multiple heating and cooling ramp rates as well as variable dwell times at fixed temperatures allowing precise control of heating and cooling rates to within 5 K. The instrument can work under a controlled atmosphere. Thanks to the circular geometry of the induction coils, the heat is homogeneously distributed in the internal volume of the graphite cell ( ca . 150 mm 3 ) where the sample holder is located. The thermal gradient within the furnace is less than 5 K over a height of ca . 5 mm. This new furnace design is well suited to the study of melting and solidification processes in geomaterials, ceramics and several metallic alloys, allowing fast heating (tested up to 6.5 K s -1 ) and quenching (up to 21 K s -1 ) in order to freeze the sample microstructure and chemistry under high-temperature conditions. The sample can be held at high temperatures for several hours, which is essential to follow phenomena with relatively slow dynamics, such as crystallization processes in geomaterials. The utility of the furnace is demonstrated through a few examples of experimental applications performed at the Elettra synchrotron laboratory (Trieste, Italy).

Kudrna Prašek, Marko↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

Recent developments in microtomography at GeoSoilEnviroCARS

A facility for x-ray computed microtomography (CMT) is operating as a national user facility for earth and environmental sciences research on the bending magnet beamline at the GeoSoilEnviroCARS sector at the Advanced Photon Source (APS). The APS bending magnet has a critical energy of 20 keV, and thus provides high flux at photon energies up to 100 keV, making it well suited to imaging a wide range of earth materials up to several cm in size. The beamline is equipped with a Si (111) double-crystal monochromator covering the energy range from 5 to 70 keV with beam sizes up to 50mm wide and 6mm high. The transmitted x-rays are imaged with a single crystal YAG or CdWO{sub 4} scintillator, a microscope objective and a 1300 x 1030 pixel 12-bit 5MHz CCD detector. The maximum spatial resolution is under 1.5 {micro}m in both the transmission radiographs and the reconstructed slices. Data collection times for full 3-D datasets range from 5-60 minutes. This facility has been used for a wide range of studies, including multiphase fluids in porous media, high-pressure studies, meteorites, and hyper-accumulating plants. We present recent technical improvements in the system, which include improved optics for samples larger than 5mm, significant reduction of ring artifacts, and correction of mechanical errors in the rotation stage.

43 PARTICLE ACCELERATORS↗

Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research

Purpose: Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. Methods: A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. Results: The authors’ experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors’ technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. Conclusions: This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure.

60 APPLIED LIFE SCIENCES↗

Microtomography of partially molten rocks : three-dimensional melt distribution in mantle peridotite.

The permeability of the upper mantle controls melt segregation beneath spreading centers. Reconciling contradictory geochemical and geophysical observations at ocean ridges requires a better understanding of transport properties in partially molten rocks. Using x-ray synchrotron microtomography, we obtained three-dimensional data on melt distribution for mantle peridotite with various melt fractions. At melt fractions as low as 0.02, triple junctions along grain edges dominated the melt network; there was no evidence of an abrupt change in the fundamental character of melt extraction as melt fraction increased to 0.2. The porosity of the partially molten region beneath ocean ridges is therefore controlled by a balance between viscous compaction and melting rate, not by a change in melt topology.

58 GEOSCIENCES↗

Upgraded X-ray topography and microtomography beamline at the Kurchatov synchrotron radiation source

An upgraded X-ray Topography and Microtomography (XRT-MT) station is described, the parameters of the optical schemes and detectors are given, and the experimental possibilities of the station are analyzed. Examples of tomographic reconstructions are reported which demonstrate spatial resolutions of 2.5 and 10 {mu}m at fields of view of 2.5 and 10 mm, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of a Deformed Inhomogeneous Material on the Data of Acoustic Emission and X-Ray Computer Microtomography

Accumulation of defects at various stages of the deformation of a structurally inhomogeneous material (granite) has been studied using two nondestructive methods: acoustic emission (AE) and X-ray computer microtomorgaphy (CT). The quasi-static testing of cylindrical samples of a Westerly granite was carried out under uniaxial compression. The control of the defect formation was realized using the real-time monitoring of acoustic emission. For each sample under study, several steps of the loading and tomographic imaging have been performed. We have found that an exponential or power-law function of the energy distribution of the AE signals makes it possible to select a sample region, in which the system of defects has transited into a self-organized criticality state and large cracks have been formed. This result coincides with the data of the X-ray tomography Computer Microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lithium-Sulfur Batteries with a Block Copolymer Electrolyte Analyzed by X-ray Microtomography

Most of the work on Lithium-sulfur (LiS) batteries use liquid electrolytes that have limited stability when coupled with Li metal anodes. We have studied LiS batteries with a solid block copolymer electrolyte which exhibits improved stability against Li anodes. Additionally, the electrolyte comprises a polystyrene-b-poly(ethylene oxide) (SEO) copolymer doped with a Li salt. Hollow carbon nanospheres impregnated with sulfur were used to build a composite cathode. Two types of sulfur-impregnated functionalized carbon nanospheres were used: One with carboxylic acid groups and the other with short lithium poly(4-styrenesulfonyl(trifluoromethylsulfonyl)imide) (PSTFSI-Li) chains. Cells with Li S dissolved in the SEO based electrolyte served as the baseline. After cycling, the reason for capacity fade was determined by imaging the batteries using synchrotron hard X-ray microtomography. It is generally assumed that LiS cells fail due to dissolution of polysulfide into the liquid electrolyte, i.e., the main problems related to the cathode. In our all-solid cells, failure was primarily due to delamination of the Li foil from the polymer electrolyte layer. Delamination is also observed at the sulfur cathode. It is likely that the large changes in volume of the active materials during cycling induce delamination in all-solid LiS cells. 2 8

25 ENERGY STORAGE↗

Pore-Scale Oil Connectivity and Displacement by Controlled-Ionic-Composition Waterflooding Using Synchrotron X-Ray Microtomography

Controlled-ionic-composition waterflooding is an economic and effective method to improve oil recovery in carbonate oil reservoirs. Recent studies show controlling the salinity and ionic composition of injection water can alter the wettability of carbonate mineral surfaces. The pore-scale oil connectivity and displacement by controlled-ionic-composition waterflooding in heterogeneous carbonate reservoirs, especially at the early stage, is still unclear. The goal of this study is to examine the role of ion concentrations and types in the oil displacement efficiency and investigate the impact of the waterflooding on the pore-scale oil displacement using the national synchrotron facility. A carbonate rock sample was flooded with synthetic high-salinity water and other water solutions with different sulfate concentrations. The waterflooding processes were visualized with synchrotron X-ray microtomography to follow the evolution of pore-scale oil/brine interactions at typical field flow rates. Experimental results show that the water with lower sulfate concentration and higher salinity did not change the wettability of the pore surfaces. Higher sulfate ion concentrations in the water, in contrast, altered the wettability of carbonate pore surfaces from oil-wet to neutral-wet within the first few minutes of waterflooding. Finally, novel insight was gained on the ability of water with high-sulfate concentration to displace oil in the small pores and through abundant oil channels, which could consequently lead to higher oil recovery from the carbonate rock.

04 OIL SHALES AND TAR SANDS↗

Using Low-Field Nuclear Magnetic Resonance and X-Ray Computed Microtomography Imaging to Explore Potential of Microbially-Induced Calcium Carbonate Precipitation Treatment to Seal Shale Fractures

Microbially-induced calcium carbonate precipitation (MICP) is a biological process in which microbially produced urease enzymes convert urea and calcium into solid calcium carbonate (CaCO 3 ) deposits. Studies have shown that MICP can be used to seal fractures in shale, raising the possibility of applying this technology to restimulate fracking wells by plugging underperforming fractures. For this and other applications to become a reality, non-invasive tools are needed to determine how effectively MICP seals shale fractures under subsurface conditions. In this study, a 2.54 cm wide and 5.08 cm long Marcellus shale core with a single, ~1 mm wide fracture held open by sand "proppant" underwent MICP-treatment at 60°C until reaching three orders of magnitude permeability reduction. Low-field nuclear magnetic resonance (LF-NMR) and X-Ray computed microtomography (μ-CT) techniques were used to assess the extent of biomineralization within the fracture. These tools revealed that while CaCO 3 precipitation occurred throughout the fracture, there was preferential precipitation around proppant, and the core sealed at the effluent end before filling most of the fracture. Both tools were able to independently calculate of the amount of solid biomineral formed inside the fracture. Furthermore, this study found that the distribution of proppant within the shale fracture was an important parameter controlling the degree of biomineralization.

clastic rock↗

Search for Organic Nanoglobules in Carbonaceous Chondrites Using Microtomography

Primitive solar materials have various organic matters. In recent years, novel organic materials called organic nanoglobules of a few hundred micrometers in typical size were discovered in carbonaceous chondrites, IDPs, and comet 81P/Wild 2. The organic globules are spherical shape and in many cases with hollow structures. Composition of the globules are mainly aromatic carbon. The isotopic anomalies of SD and 6N 15 observed in the globules indicate that they were formed from photochemical reaction to ice particles at very low temperature environment, such as molecular clouds or outer protosolar disk. Aqueous alteration of organic matters and the gamma-ray irradiation to PAH are also suggested as alternative possible formation processes. If the globules are made from organic ice particles, the hollow regions of the globules are suggested to be once filled with volatile H20-rich organic ices, while if they were formed by aqueous alteration, the hollow regions should be filled with a fluid which caused the aqueous alteration. However, fluids in the globules have not been detected so far in the previous studies. If fluids were originally preserved in the hollows, they might be lost during destructive processes of sample separation or preparation for TEM observation. X-ray computed tomography (CT) is a nondestructive method which can determine 3-D internal structures of objects. SR (synchrotron radiation)-based imaging microtomography can give submicron spatial resolution [8] and was applied to micro textures in extraterrestrial materials, such as cometary grains captured by the Stardust mission [9]. If organic globules are observed non-destructively in carbonaceous chondrites by tomography, we can check the presence of fluids in the hollows. If fluids are preserved, we may analyze chemical and isotopic compositions of the fluids. The purpose of this study is to observe organic nanoglobules using imaging tomography for future analysis.

Matsumoto, T.↗

In-Situ Synchrotron X-ray Computed Microtomography and Diffraction Investigation of Deformation and Fracture Behavior in a Laser Powder Bed Fusion Processed 316L Stainless Steel

Introduce defects into laser powder bed fusion stainless steel samples by controlling processing parameters. Perform in-situ x-ray microtomography on L-PBF stainless steel samples during plastic deformation. Relate defect characteristics and evolution to tensile behavior. Understand how processing conditions translate to initial defect characteristics. Track and evaluate defect evolution as a function of plastic deformation. Determine how deformation and fracture mechanics change as a result of AM defects.

36 MATERIALS SCIENCE↗