Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microcalorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic diagnostics of high-temperature plasma in stellar coronae using Fe XXIV-XXIV K-shell lines with XRISM

The RS CVn type binary star GT Muscae was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV-XXIV K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional ionization equilibrium and Maxwell electron energy distribution with a single temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$\alpha$, Ly$\alpha$, and He$\beta$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with thermal broadening of Fe xxv, and the broad-band fitting results in the 1.7–10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $\kappa$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

X-rays: stars↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Matter Search in Pu-241 Beta Decays

Our universe is predominantly composed of mysterious unknowns: Dark Matter (DM) and Dark Energy. DM constitutes approximately 27% of the universe, yet its nature and origins remain elusive. Among the various candidates for dark matter, this project focuses on the search for keV-scale sterile neutrinos. A sterile neutrino is a hypothetical particle that belongs to the neutrino family and may possess a higher mass than ordinary neutrinos. They are considered a compelling warm dark matter candidate if their mass is on the order of kilo-electronvolts. Existence of sterile neutrinos can be investigated via high precision beta spectroscopy. Sterile neutrinos can be produced during nuclear beta decay processes, similar to ordinary active neutrinos, but they uniquely alter the beta decay spectrum. The emission of sterile neutrinos will introduce a distinctive "kink" structure in the middle of the beta spectrum. This project investigated the existence of sterile neutrino dark matter by employing high-precision decay energy spectroscopy of Pu-241 beta decays using magnetic microcalorimeters (MMCs). The Pu-241 source material is embedded within the microcalorimeter detectors, enabling the measurement of full beta decay energies with ultra-high energy resolution. In this project, the most precise Pu-241 spectrum to date was obtained by collecting a total of 1 billion beta decay events in the MMC detectors. This extensive data set allows us to investigate evidence of keV sterile neutrino emission in beta decays with unprecedented sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Validation of Calorimetric Electron Capture Spectral Theory with 193 Pt

Using microcalorimeters, a high statistics, high-resolution calorimetric spectrum of electron capture in 163 Ho can be used to determine the neutrino mass. The spectral shape can be calculated from first principles with various assumptions and approximations. To determine the validity of these choices, the theoretical calculations must be compared to data from multiple isotopes. In this work, new calorimetric data for a 193 Pt-in-Pt absorber measured with a transition edge sensor are presented and compared to theoretical calculations and values from the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser

Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

Physics↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delving into the depths of NGC 3783 with XRISM

We present our study of the X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the Seyfert-1 galaxy NGC 3783. XRISM’s Resolve microcalorimeter has enabled, for the first time, a detailed characterization of the highly ionized outflows in this active galactic nucleus. Our analysis constrains their outflow and turbulent velocities, along with their ionization parameter (ξ) and column density (N H ). The high-resolution Resolve spectrum reveals a distinct series of Fe absorption lines between 6.4 and 7.8 keV, ranging from Fe XVIII to Fe XXVI. At lower energies (1.8−3.3 keV), absorption features from Si, S, and Ar are also detected. Our spectroscopy and photoionization modeling of the time-averaged Resolve spectrum uncovers six outflow components, five of which exhibit relatively narrow absorption lines with outflow velocities ranging from 560 to 1170 km s −1 . In addition, a broad absorption feature is detected, which is consistent with Fe XXVI outflowing at 14 300 km s −1 (0.05 c). The kinetic luminosity of this component is 0.8−3% of the bolometric luminosity. Our analysis of the Resolve spectrum shows that more highly ionized absorption lines are intrinsically broader than those of lower-ionization species, indicating that the turbulent velocity of the six outflow components (ranging from 0 to 3500 km s −1 ) increases with ξ. Furthermore, we find that the column density (N H ) of the outflows generally declines with the ionization parameter up to log ξ = 3.2 but rises beyond this point, suggesting a complex ionization structure. The absorption profile of the Fe XXV resonance line is intriguingly similar to UV absorption lines (Lyα and C IV) observed by the Hubble Space Telescope, from which we infer that the outflows are clumpy in nature. Our XRISM/Resolve results from lower- and higher-ionization regimes support a “hybrid wind” scenario in which the observed outflows have multiple origins and driving mechanisms. We explore various interpretations of our findings within active galactic nucleus wind models.

X-rays: galaxies↗