Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “memory usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

58 records · Page 4

RAID 7 disk array

Each RAID level reflects a different design architecture. Associated with each is a backdrop of imposed limitations, as well as possibilities which may be exploited within the architectural constraints of that level. There are three unique features that differentiate RAID 7 from all other levels. RAID 7 is asynchronous with respect to usage of I/O data paths. Each I/O drive (includes all data and one parity drives) as well as each host interface (there may be multiple host interfaces) has independent control and data paths. This means that each can be accessed completely, independently, of the other. This is facilitated by a separate device cache for each device/interface as well. RAID 7 is asynchronous with respect to device hierarchy and data bus utilization. Each drive and each interface is connected to a high speed data bus controlled by the embedded operating system to make independent transfers to and from central cache. RAID 7 is asynchronous with respect to the operation of an embedded real time process oriented operating system. This means that exclusive and independent of the host, or multiple host paths, the embedded OS manages all I/O transfers asynchronously across the data and parity drives. A key factor to consider is that of the RAID 7's ability to anticipate and match host I/O usage patterns. This yields the following benefits over RAID's built around micro-code based architectures. RAID 7 appears to the host as a normally connected Big Fast Disk (BFD). RAID 7 appears, from the perspective of the individual disk devices, to minimize the total number of accesses and optimize read/write transfer requests. RAID 7 smoothly integrates the random demands of independent users with the principles of spatial and temporal locality. This optimizes small, large, and time sequenced I/O requests which results in users having an I/O performance which approaches performance to that of main memory.

Stout, Lloyd↗

Shape-Memory-Alloy-Based Deicing System Developed

Ice buildup on aircraft leading edge surfaces has historically been a problem. Most conventional deicing systems rely either on surface heating to melt the accreted ice or pneumatic surface inflation to mechanically debond the ice. Deicers that rely solely on surface heating require large amounts of power. Pneumatic deicers usually cannot remove thin layers of ice and lack durability. Thus, there is a need for an advanced, low-power ice protection system. As part of the NASA Small Business and Innovation Research (SBIR) program, Innovative Dynamics, Inc., developed an aircraft deicing system that utilizes the properties of Shape Memory Alloys (SMA). The SMA-based system has achieved promising improvements in energy efficiency and durability over more conventional deicers. When they are thermally activated, SMA materials change shape; this is analogous to a conventional thermal expansion. The thermal input is currently applied via conventional technology, but there are plans to implement a passive thermal input that is supplied from the energy transfer due to the formation of the ice itself. The actively powered deicer was tested in the NASA Lewis Icing Research Tunnel on a powered rotating rig in early 1995. The system showed promise, deicing both rime and glaze ice shapes as thin as 1/8 in. The first prototype SMA deicer reduced power usage by 45 percent over existing electrothermal systems. This prototype system was targeted for rotorcraft system development. However, there are current plans underway to develop a fixed-wing version of the deicer.

Source record↗

SEE and TID extension testing of the Xilinx XQR18V04 4Mbit radiation hardened configuration PROM

The XQR18V04 was evaluated for single event upset rates using proton and heavy ions. The PROM was demonstrated to be immune to latch-up, as well as to static upset in the flash memory cells, to an LET > 125 MeV/mg/cmz (effective). The PROM was also tested in a dynamic mode, which revealed three distinct error modes: Read Bit Errors, Address Errors, and a Single Event Functional Interrupt (SEW which affected the data output drivers. Saturation cross-sections, and onset thresholds, for these errorinodes were measured at the heavy ion facility at Texas A&M University, and the proton facility at UC Davis. Additional testing was performed at UC Davis and the Cobalt 60 source at McClellan Air Force Base to examine the effect to TID life as a function of power biasing. The PROM demonstrated a 100% improvement in total TID life with an 84% percent decrease in device usage.

FPGA Virtex II SEU↗

Electra: A Modular-Based Expansion of NASA's Supercomputing Capability

NASA has increasingly relied on high-performance computing (HPC) re- sources for computational modeling, simulation, and data analysis to meet the science and engineering goals of its missions in space exploration, aeronautics, and Earth and space science. The NASA Advanced Supercomputing (NAS) Division at Ames Research Center in Silicon Valley, Calif., hosts NASA’s premier supercomputing resources, integral to achieving and enhancing the success of the agency’s missions. NAS provides a balanced environment, funded under the High-End Computing Capability (HECC) project, comprised of world-class supercomputers, including its flagship distributed-memory cluster, Pleiades; high-speed networking; and massive data storage facilities, along with multi-disciplinary support teams for user support, code porting and optimization, and large-scale data analysis and scientific visualization. However, as scientists have increased the fidelity of their simulations and engineers are conducting larger parameter-space studies, the requirements for supercomputing resources have been growing by leaps and bounds. With the facility housing the HECC systems reaching its power and cooling capacity, NAS undertook a prototype project to investigate an alternative approach for housing supercomputers. Modular supercomputing, or container-based computing, is an innovative concept for expanding NASA’s HPC capabilities. With modular supercomputing, additional containers—similar to portable storage pods—can be connected together as needed to accommodate the agency’s ever-increasing demand for computing resources. In addition, taking advantage of the local weather permits the use of cooling technologies that would additionally save energy and reduce annual water usage. The first stage of NASA’s Modular Supercomputing Facility (MSF) prototype, which resulted in a 1,000 square-foot module on a concrete pad with room for 16 compute racks, was completed in Fall 2016 and an SGI (now HPE) computer system, named Electra, was deployed there in early 2017. Cooling is performed via an evaporative system built into the module, and preliminary experience shows a Power Usage Effectiveness (PUE) measurement of 1.03. Electra achieved over a petaflop on the LINPACK benchmark, sufficient to rank number 96 on the November 2016 TOP500 list [14]. The system consists of 1,152 InfiniBand-connected Intel Xeon Broadwell-based nodes. Its users access their files on a facility-wide file system shared by all HECC compute assets via Mellanox MetroX InfiniBand extenders, which connect the Electra fabric to Lustre routers in the primary facility over fiber-optic links about 900 feet long. The MSF prototype has exceeded expectations and is serving as a blueprint for future expansions. In the remainder of this chapter, we detail how modular data center technology can be used to expand an existing compute resource. We begin by describing NASA’s requirements for supercomputing and how resources were provided prior to the integration of the Electra module-based system.

Biswas, Rupak↗