Issues in Formation of Cryogenic Pellets for Fusion Applications

Cryogenic pellets are used for injection into fusion plasmas to add fuel to build up density and replace the ions lost from fusion reactions and imperfect confinement in the plasma. These pellets are formed at cryogenic temperatures with pure hydrogenic isotopes or mixtures of the isotopes. Technology to make these pellets and inject them into plasmas has been under development for many years, and various methods using freezing or desublimation have been shown to produce high-quality solid pellets suitable for injection. The throughput needed and possible impurity content from the necessary recirculation of fusion exhaust gases are two of the key issues to overcome for fusion pellet fueling systems in long-pulse burning plasmas. Here, we describe the technical challenges associated with these issues and the capability of pellet formation extruders to overcome them.Cryogenic pellets of deuterium, neon, and argon are also used in fusion tokamak devices for disruption mitigation in the form of large pellets that can be injected on demand to quickly dissipate the plasma thermal energy through radiation and add significant density in order to prevent runaway electron formation. Here, the issue is not throughput as with the fueling pellets but rather is the time it takes to form pellets of the size needed and the ability to dislodge them immediately on demand when needed to mitigate a disruption. The method used to make these pellets by desublimation is described, and examples related to how pellet size and input gas parameters affect the formation time are provided.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Fidelity CFD Modeling of Cryogenic Hydrogen Isotope Extrusion for Fusion Reactor Pellet Fueling

This study investigates the extrusion processes of deuterium and protium using ANSYS-Polyflow. The geometries and computational fluid dynamics (CFD) settings closely replicate the experimental setups and data acquired from the extruder experiments at Oak Ridge National Laboratory (ORNL) for validation purposes. We explore the impacts of (1) slip versus non-slip boundary conditions and (2) the use of constant, temperature-, and shear rate–dependent viscosities, concluding that the implementation of non-slip wall boundary conditions combined with shear rate–dependent viscosity produced more accurate predictions. The simulations achieved excellent agreement with the experimental data, with relative differences of only 5% for deuterium, and 3% to 6% for protium. This is the first time that experimental extrusion data at ORNL have been accurately predicted through high-fidelity CFD modeling. In conclusion, the advancements offer valuable insights and a foundational modeling tool for optimizing pellet injectors for ITER and other future reactor-scale devices.

ANSYS-Polyflow↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent progress in shattered pellet injection technology in support of the ITER disruption mitigation system*

Shattered pellet injection (SPI) has been selected as the baseline technology for the disruption mitigation (DM) system for ITER. Typical SPI utilizes cryogenic cooling to desublimate low pressure (<100 mbar) gases onto a cold zone within a pipe gun barrel, forming a cylindrical pellet. Pellets are dislodged from the barrel and accelerated using either a gas driven mechanical punch or high-pressure light-gas delivered by a fast-opening valve. SPI technology developed at Oak Ridge National Laboratory is currently deployed and operational on DIII-D, JET, and KSTAR. These SPI systems are used in experiments for physics scaling to ITER thermal mitigation and runaway electron dissipation/avoidance. The pellet sizes used for these machines are in the range of 4 to 12.5 mm in diameter with length to diameter ratios (L/D) of ~1.5. The current plan for ITER SPI is to utilize pellets that are 28.5 mm in diameter with an L/D of ~2. Furthermore, the large pellet sizes, high steady-state magnetic fields, and limitations of operating in a radiation environment render much of the current technology unusable. In addition to technology improvements, a deeper understanding of pellet material properties, formation, and release is being developed for implementation in future SPI designs, specifically ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Continuous Pellet Fueling System for Wendelstein 7-X

A continuous pellet fueling system (CPFS) is currently being designed at the Oak Ridge National Laboratory (ORNL) for the long pulse operation of the Wendelstein 7-X (W7-X) stellarator. The purpose of the CPFS is to provide deep continuous fueling for feedback-controlled high-density operation and mitigation of predicted hollow density profiles. As described here, the system will provide the capability to inject cylindrical pellets of solid hydrogen or deuterium into the plasma core, with flexibility to vary the pellet size, velocity, and injection frequency. Pellets are nominally of 3 mm in diameter and have a length between 1 and 4 mm. The heart of the CPFS is a vertically oriented, twin-screw extruder, cooled by three Gifford-McMahon cryocoolers in parallel, designed to form a continuous filament of hydrogen or deuterium. The filament width, which determines the pellet length, can be adjusted by means of a variable nozzle driven by a linear actuator at the base of the extruder. Coupled to the nozzle is a solenoid-operated gas gun and cutter assembly. A pneumatic propellant valve pulses a burst of ~60 bar helium to accelerate the cut pellet into W7-X. Three gaps in the guide tubes provide pumping locations to remove the helium propellant before it reaches the plasma. The maximum velocity of the pellet is limited by its ability to survive navigating the guide tube trajectory intact. A microwave cavity located within the guide tube provides the capability to measure the pellet size and velocity. The mechanical and thermal designs of the W7-X extruder, adjustable nozzle, and gun and cutter assembly design are described. A guide tube design and experimental pellet survivability test results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modifications to the JET Shattered Pellet Injector to Optimize Disruption Mitigation Experiments for Supporting ITER’s DMS Design

Shattered pellet injection (SPI) experiments on Joint European Torus (JET) are an important element in determining the physics basis for mitigating disruptions in ITER. Here, the initial design of the JET SPI system included three barrels to produce pellets with diameters of 4.5, 8.1, and 12.5 mm. The variability of the pellet speed by operating with and without a mechanical punch was limited and led to poor pellet integrity, so the mechanical punch was removed. Fragment size distribution is a function of pellet speed and the desire to change the resulting fragment size distribution was not originally a requirement. After the first set of SPI experiments on JET, different pellet sizes were considered to enable dual injection experiments with identical pellet diameters. It was also determined that speed control is necessary to improve experimental repeatability and to determine how the fragment size distribution impacts mitigation performance. Two barrels were fabricated to form pellets of 10 mm diameter and a third to form an 8.1 mm diameter pellet. New propellant valves were also fabricated and characterized to improve repeatability and overall performance. To have fine control of pellet speed, inserts to reduce the breech volume were fabricated and installed. Laboratory testing was conducted to ensure pellet release and provide a comparison of propellant gas delivered versus pellet speeds for a range of pellet types and mixtures. This article will also discuss how lessons learned from the JET SPI modifications can be applied to other SPI systems, such as the ITER SPI system, as controlling pellet release with the least amount of propellant gas is essential for optimal SPI effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Water table tests of proposed heat transfer tunnels for small turbine vanes

Water-table flow tests were conducted for proposed heat-transfer tunnels which were designed to provide uniform flow into their respective test sections of a single core engine turbine vane and a full annular ring of helicopter turbine vanes. Water-table tests were also performed for the single-vane test section of the core engine tunnel. The flow in the heat-transfer tunnels was shown to be acceptable.

Meitner, P. L.↗

Turbine vane coolant flow variations and calculated effects on metal temperatures

Seventy-two air-cooled turbine vanes were tested to determine coolant flow variations among the vanes. Calculations were made to estimate the effect of measured coolant flow variations on local vane metal temperatures. The calculations were based on the following assumed operating conditions: turbine inlet temperature, 1700 K (2600 F); turbine inlet pressure, 31 N/sq cm (45 psia); coolant inlet temperature, 811 K (1000 F); and total coolant to gas flow ratio, 0.065. Variations of total coolant flow were not large (about 10 percent from the arithmetic mean) for all 72 vanes, but variations in local coolant flows were large. The local coolant flow variations ranged from 8 to 75 percent, and calculated metal temperature variations ranged from 8 to 60 K (15 to 180 F).

Yeh, F. C.↗

Experimental flow coefficients of a full-coverage film-cooled-vane chamber

Ambient- and elevated-temperature flow tests were performed on a four-times-actual-size model of an impingement- and film-cooled segment of a core engine turbine vane. Tests were conducted with the impingement and film cooling plates combined to form a chamber and also with each of the individual separated plates. For the combined tests, the proximity of the film cooling plate affected the flow of coolant through the impingement plate, but not conversely. Impingement flow is presented in terms of a discharge coefficient, and the film cooling flow discharging into still air with no main stream gas flow is presented in terms of a total pressure-loss coefficient. The effects of main stream gas flow on discharge from the film cooling holes are evaluated as a function of coolant to main-stream gas momentum flux ratio. A smoothing technique is developed that identifies and helps reduce flow measurement data scatter.

Meitner, P. L.↗

FORTRAN program for calculating coolant flow and metal temperatures of a full-coverage-film-cooled vane or blade

A computer program that calculates the coolant flow and the metal temperatures of a full-coverage-film-cooled vane or blade was developed. The analysis was based on compressible, one-dimensional fluid flow and on one-dimensional heat transfer and treats the vane or blade shell as a porous wall. The calculated temperatures are average values for the shell outer-surface area associated with each film-cooling hole row. A thermal-barrier coating may be specified on the shell outer surface, and centrifugal effects can be included for blade calculations. The program is written in FORTRAN 4 and is operational on a UNIVAC 1100/42 computer. The method of analysis, the program input, the program output, and two sample problems are provided.

Meitner, P. L.↗

Analysis of metal temperature and coolant flow with a thermal-barrier coating on a full-coverage-film-cooled turbine vane

The potential benefits of combining full-coverage film cooling with a thermal-barrier coating were investigated analytically for sections on the suction and pressure sides a high-temperature, high-pressure turbine vane. Metal and ceramic coating temperatures were calculated as a function of coating thickness and coolant flow. With a thermal-barrier coating, the coolant flows required for the chosen sections were half those of an uncoated design, and the metal outer temperatures were simultaneously reduced by over 111 K (200 F). For comparison, transpiration cooling was also investigated. Full-coverage film cooling of a coated vane required more coolant flow than did transpiration cooling.

Meitner, P. L.↗

Full-coverage film cooling

Program calculates coolant flow and wall temperatures of full-coverage film-cooled vanes or blades. Thermal barrier coatings may be specified on outer surfaces of blade. Program is written in FORTRAN IV for batch execution on UNIVAC 1100.

Meitner, P. L.↗

Micromorphology of neurohypophysis of rats under experimental conditions

The changes of the quantity of neurosecretory substance in neurohypophysis of rats under various experimental conditions are investigated. Comparing to the norm the quantity of neurosecretion after a long stay in the dark was larger. In animals subjected to immobilization stress the picture of neurohypophysis remained unchanged. It changed only in correlation with the administered water. Results indicate that the immobilization stress, in contradistinction to dolorose stress, has no substantial influence upon the quantity of neurosecretion in neurohypophysis.

Meitner, E. R.↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model is developed for variable-area (pivoted vane) radial turbines. The variation in stator loss with stator area is determined by a viscous loss model while the variation in rotor loss due to stator area variation (for no stator end-clearance gap) is determined through analytical matching of experimental data. An incidence loss model is also based on matching of the experimental data. A stator vane end-clearance leakage model is developed and sample calculations are made to show the predicted effects of stator vane end-clearance leakage on performance.

Meitner, P. L.↗

Effects of immobilization on spermiogenesis

The influence of immobilization stress on spermiogenesis in rats was investigated. After 96 hour immobilization, histological changes began to manifest themselves in the form of practically complete disappearance of cell population of the wall of seminiferous tubule as well as a markedly increased number of cells with pathologic mitoses. Enzymological investigations showed various changes of activity (of acid and alkaline phosphatase and nonspecific esterase) in the 24, 48, and 96 hour immobilization groups.

Meitner, E. R.↗

Off-design performance loss model for radial turbines with pivoting, variable-area stators

An off-design performance loss model was developed for variable stator (pivoted vane), radial turbines through analytical modeling and experimental data analysis. Stator loss is determined by a viscous loss model; stator vane end-clearance leakage effects are determined by a clearance flow model. Rotor loss coefficient were obtained by analyzing the experimental data from a turbine rotor previously tested with six stators having throat areas from 20 to 144 percent of design area and were correlated with stator-to-rotor throat area ratio. An incidence loss model was selected to obtain best agreement with experimental results. Predicted turbine performance is compared with experimental results for the design rotor as well as with results for extended and cutback versions of the rotor. Sample calculations were made to show the effects of stator vane end-clearance leakage.

Meitner, P. L.↗