Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-Precision Mapping of Diamond Crystal Strain Using Quantum Interferometry

Crystal-strain variation imposes significant limitations on many quantum sensing and information applications for solid-state defect qubits in diamond. Thus, the precision measurement and control of diamond crystal strain is a key challenge. Here, we report diamond strain measurements with a unique set of capabilities, including micron-scale spatial resolution, a millimeter-scale field of view, and a 2-order-of-magnitude improvement in volume-normalized sensitivity over previous work, reaching 5(2)×10 -8 /√Hzμm -3 (with spin-strain coupling coefficients representing the dominant systematic uncertainty). We use strain-sensitive spin-state interferometry on ensembles of nitrogen-vacancy (N-V) color centers in single-crystal bulk diamond with low strain gradients. This quantum interferometry technique provides insensitivity to magnetic-field inhomogeneity from the electronic and nuclear spin bath, thereby enabling long N-V–ensemble electronic spin dephasing times and enhanced strain sensitivity, as well as broadening the potential applications of the technique beyond isotopically enriched or high-purity diamond. We demonstrate the strain-sensitive measurement protocol first on a confocal scanning laser microscope, providing quantitative measurement of sensitivity as well as three-dimensional strain mapping; and second on a wide-field-imaging quantum diamond microscope. Our strain-microscopy technique enables fast, sensitive characterization for diamond material engineering and nanofabrication; as well as diamond-based sensing of strains applied externally, as in diamond anvil cells or embedded diamond stress sensors, or internally, as by crystal damage due to particle-induced nuclear recoils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum metrology of low-frequency electromagnetic modes with frequency upconverters

We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the very high frequency band (VHF) ( ≲ 300 MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ( ∼ 5 GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use nonclassical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc VHF electromagnetic modes as quantum sensors with sensitivity better than the standard quantum limit (SQL). We demonstrate signal upconversion from low frequencies to the microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of 46.9 dB , which is a necessary step towards the realization of full BAE. Published by the American Physical Society 2025

Kuenstner, Stephen E. (ORCID:0000000346128846)↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Its subsequent use in the field and review by the protocol working group and most importantly the users’ subgroup and the thermal subgroup has led to the fundamental modifications reflected in this update of the 2012 Protocol. As an update of the 2012 Protocol, this document (the June 2014 Protocol) is intended to supersede its predecessor and be used as the basis for measuring and expressing ESS performance. The foreword provides general and specific details about what additions, revisions, and enhancements have been made to the 2012 Protocol and the rationale for them in arriving at the June 2014 Protocol.

energy storage system↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL-22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance. This foreword1 provides general and specific details about what additions, revisions, and enhancements have been made to the June 2014 Protocol and the rationale for them in arriving at this March 2016 Protocol (PNNL-22010 Rev. 2).

25 ENERGY STORAGE↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL 22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance.

25 ENERGY STORAGE↗

Advances in benchmarking and round robin testing for PEM water electrolysis: Reference protocol and hardware

While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.

08 HYDROGEN↗

Eisenbud–Wigner–Smith time delay in atom–laser interactions

We report recent development of ultrafast measurement techniques on the sub-femtosecond time scale has enabled us to see the atom–laser interaction in real time. One of the important observables to study the temporally resolved dynamics is the various time delay in the process. Time delays is an experimentally measurable quantity, where the time is not. Time delays in quantum collisions and in photoionization/photodetachment of atomic and molecular systems is reviewed. The formalisms of time delay in the context of quantum collisions by Eisenbud and Wigner that by Smith and their equivalence is discussed. The time-reversal symmetry between solutions with outgoing and ingoing wave boundary conditions allow us to interpret photoionization/photodetachment as half-scattering. Subsequently, the formalism of Eisenbud–Wigner–Smith time delay is extended in photoionization/photodetachment from collisions. We discuss that the time delay can be written as a self-adjoint quantum operator which depicts its measurability. On the experimental side, the measurement protocols are reviewed for attosecond streaking and RABBITT. Along with the EWS time delay, the measurement introduces an additional (which is negative) time delay. From the measurement of total delay and an analytical/numerical estimate of the measurement induced part, one gets the EWS time delay in the process. A few illustrative examples of studies on time delay are given to get a flavour of the outstanding advances made in this field in the last two decades.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time domain-induced polarization geophysical data collected in the Rifle Floodplain, Colorado, USA

The IP data set was collected using a time domain-induced polarization (TDIP) method along 65 profiles of various lengths over the floodplain. Surface time domain?induced polarization (TDIP) data was collected to create the 3?D images of the complex electrical resistivity, in terms of magnitude and phase, which are associated with mineral precipitation and other lithological properties. The TDIP data was then used to estimate the spatial distribution of naturally reduced zones, which are known to be biogeochemical hotspots in floodplains having increased uranium and other redox-sensitive metal concentrations as well as high carbon contents. In the TDIP method, the transient decay of voltage is measured after current shut-off, typically in the form of an integral of decay curves over a predefined time window (so-called integral chargeability). TDIP measurements at the site were collected using the Syscal Iris Pro Switch equipment with a square-wave current injection, 50% duty cycle, and a pulse length of 2 s. The integral chargeability measurements were carried out using 20 windows during voltage decay between 240 and 1840 ms after current shut-off. Tomographic measurements were collected by deploying stainless steel electrodes with an electrode separation of 1.8 m and using a dipole-dipole ‘‘skip-2’’ and ‘‘skip-3’’ measuring protocol (i.e., for a dipoles length of 5.4 and 7.2 m, respectively). The sequence of dipole-dipole measurements was carefully arranged to (1) minimize unwanted electromagnetic coupling effects in the data, avoiding potential measurements with electrodes located inside the current dipole, (2) prevent voltage measurements using electrodes, which might be polarized due to previous current injection, and (3) increase the signal-to-noise ratio for an intended exploration depth of 8 m, i.e., the bottom of the aquifer. All measurements were collected as normal and reciprocal pairs for estimation of the data error. The IP measurements were collected with symmetric arrays (i.e., the measuring equipment placed at the center of the electrode array) with a maximum of 36 electrodes, considering that longer profiles revealed a significant increase in the normal-reciprocal misfit for the measurements of the decay curve, probably due to greater impact of electromagnetic coupling on the data. The TDIP data sets were inverted in a twodimensional domain along each transect using CRTomo, which is a smoothness-constraint inversion code based on a finite element algorithm. The resistivity and phase shift values at each pixel were then assigned at the corresponding point within the 3-D floodplain domain (the black rectangle Figure 1b) and used in the 3-D estimation. The TDIP inversion results provided the distribution of the complex resistivity, expressed in terms of its magnitude and phase-shift. The analysis of the normal-reciprocal misfit was used to estimate the relative error. We removed the measurement with smallest voltage difference (<2 mV), representing about 2% variations in the data. For the inversion of TDIP measurements, chargeability values were linearly converted to frequency domain phase values (at the fundamental frequency of 0.125 Hz), by assuming a constant-phase response. This approach has been demonstrated to provide consistent results in previous studies

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux Measurement Network: Science Team Research

Research involves analysis and field direction of AmeriFlux operations, and the PI provides scientific leadership of the AmeriFlux network. Activities include the coordination and quality assurance of measurements across AmeriFlux network sites, synthesis of results across the network, organizing and supporting the annual Science Team Meeting, and communicating AmeriFlux results to the scientific community and other users. Objectives of measurement research include (i) coordination of flux and biometric measurement protocols (ii) timely data delivery to the Carbon Dioxide Information and Analysis Center (CDIAC); and (iii) assurance of data quality of flux and ecosystem measurements contributed by AmeriFlux sites. Objectives of integration and synthesis activities include (i) integration of site data into network-wide synthesis products; and (ii) participation in the analysis, modeling and interpretation of network data products. Communications objectives include (i) organizing an annual meeting of AmeriFlux investigators for reporting annual flux measurements and exchanging scientific information on ecosystem carbon budgets; (ii) developing focused topics for analysis and publication; and (iii) developing data reporting protocols in support of AmeriFlux network goals.

54 ENVIRONMENTAL SCIENCES↗

TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

60 APPLIED LIFE SCIENCES↗

Calibration of the ARID robot

The author has formulated a new, general model for specifying the kinematic properties of serial manipulators. The new model kinematic parameters do not suffer discontinuities when nominally parallel adjacent axes deviate from exact parallelism. From this new theory the author develops a first-order, lumped-parameter, calibration-model for the ARID manipulator. Next, the author develops a calibration methodology for the ARID based on visual and acoustic sensing. A sensor platform, consisting of a camera and four sonars attached to the ARID end frame, performs calibration measurements. A calibration measurement consists of processing one visual frame of an accurately placed calibration image and recording four acoustic range measurements. A minimum of two measurement protocols determine the kinematics calibration-model of the ARID for a particular region: assuming the joint displacements are accurately measured, the calibration surface is planar, and the kinematic parameters do not vary rapidly in the region. No theoretical or practical limitations appear to contra-indicate the feasibility of the calibration method developed here.

Doty, Keith L↗

The Stratospheric Aerosol and Gas Experiment (SAGE) IV Pathfinder

As evidenced by quadrennial holding of this symposium and publishing of the Scientific Assessment of Ozone Depletion, the continued monitoring of and reporting on the stratospheric ozone layer is paramount to determining the efficacy of the Montreal Protocol. Measurements from satellites provided data on the initial decline of ozone in the late 1970s and early 1980s that supported the adoption of the Montreal Protocol, with current observations hinting at recovery. Adequate determination of that recovery requires continuous and, in the case of multiple instruments, overlapping data records. However, most current satellite systems are well beyond their expected lifetimes and are large and expensive. A new measurement paradigm is needed to enable cost-effective, sustainable measurements of atmospheric ozone into the coming decades when ozone is expected to recover. The Stratospheric Aerosol and Gas Experiment (SAGE) IV is a solar occultation imager capable of measuring ozone, aerosol, and other trace gas species with the same quality as previous SAGE instruments (including SAGE III/ISS). Taking advantage of recent technological advancements, a single sensorcraft occupies a 6U CubeSat form-factor providing an order of magnitude reduction in cost over traditional missions. SAGE IV is an example of an innovative and affordable mission that can sustain a crucial science measurement well into the future.

Robert Damadeo↗

Evolution of silver nanoparticles in the rat lung investigated by X-ray absorption spectroscopy

Following a 6-h inhalation exposure to aerosolized 20 and 110 nm diameter silver nanoparticles, lung tissues from rats were investigated with X-ray absorption spectroscopy, which can identify the chemical state of silver species. Lung tissues were processed immediately after sacrifice of the animals at 0, 1, 3, and 7 days post exposure and the samples were stored in an inert and low-temperature environment until measured. We found that it is critical to follow a proper processing, storage and measurement protocol; otherwise only silver oxides are detected after inhalation even for the larger nanoparticles. The results of X-ray absorption spectroscopy measurements taken in air at 85 K suggest that the dominating silver species in all the postexposure lung tissues were metallic silver, not silver oxide, or solvated silver cations. The results further indicate that the silver nanoparticles in the tissues were transformed from the original nanoparticles to other forms of metallic silver nanomaterials and the rate of this transformation depended on the size of the original nanoparticles. Furthermore, we found that 20 nm diameter silver nanoparticles were significantly modified after aerosolization and 6-h inhalation/deposition, whereas larger, 110 nm diameter nanoparticles were largely unchanged. Over the seven-day postexposure period the smaller 20 nm silver nanoparticles underwent less change in the lung tissue than the larger 110 nm silver nanoparticles. In contrast, silica-coated gold nanoparticles did not undergo any modification processes and remained as the initial nanoparticles throughout the 7-day study period.

36 MATERIALS SCIENCE↗

Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system

Purpose: In radiochromic film dosimetry systems, measurements are usually obtained from film images acquired on a CCD-based flatbed scanner. The authors investigated factors affecting scan-to-scan response variability leading to increased dose measurement uncertainty. Methods: The authors used flatbed document scanners to repetitively scan EBT3 radiochromic films exposed to doses 0–1000 cGy, together with three neutral density filters and three blue optical filters. Scanning was performed under two conditions: scanner lid closed and scanner lid opened/closed between scans. The authors also placed a scanner in a cold room at 9 °C and later in a room at 22 °C and scanned EBT3 films to explore temperature effects. Finally, the authors investigated the effect of altering the distance between the film and the scanner’s light source. Results: Using a measurement protocol to isolate the contribution of the CCD and electronic circuitry of the scanners, the authors found that the standard deviation of response measurements for the EBT3 film model was about 0.17% for one scanner and 0.09% for the second. When the lid of the first scanner was opened and closed between scans, the average scan-to-scan difference of responses increased from 0.12% to 0.27%. Increasing the sample temperature during scanning changed the RGB response values by about −0.17, −0.14, and −0.05%/°C, respectively. Reducing the film-to-light source distance increased the RBG response values about 1.1, 1.3, and 1.4%/mm, respectively. The authors observed that films and film samples were often not flat with some areas up to 8 mm away from the scanner’s glass window. Conclusions: In the absence of measures to deal with the response irregularities, each factor the authors investigated could lead to dose uncertainty >2%. Those factors related to the film-to-light source distance could be particularly impactful since the authors observed many instances where the curl of film samples had the potential to cause dose uncertainty in excess of 5%. Two expedients will eliminate the uncertainties: a transparent sheet (preferably glass) placed over the scanned film keeps the film-to-light source distance constant, and an EBT3 reference film included in all scans provides correction factors for measured response values.

60 APPLIED LIFE SCIENCES↗

Quantifying and Controlling Entanglement in the Quantum Magnet Cs 2 CoCl 4

The lack of methods to experimentally detect and quantify entanglement in quantum matter impedes our ability to identify materials hosting highly entangled phases, such as quantum spin liquids. We thus investigate the feasibility of using inelastic neutron scattering (INS) to implement a model-independent measurement protocol for entanglement based on three entanglement witnesses: one-tangle, two-tangle, and quantum Fisher information (QFI). We perform high-resolution INS measurements on Cs 2 CoCl 4 , a close realization of the S = 1/2 transverse-field XXZ spin chain, where we can control entanglement using the magnetic field, and compare with density-matrix renormalization group calculations for validation. The three witnesses allow us to infer entanglement properties and make deductions about the quantum state in the material. Overall, we find QFI to be a particularly robust experimental probe of entanglement, whereas the one and two-tangles require more careful analysis. Our results lay the foundation for a general entanglement detection protocol for quantum spin systems.

1-dimensional spin chains↗