Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Space charge trap-assisted recombination suppressing layer for low-voltage diode operation

Shockley-Read-Hall (SRH) generation and/or recombination in heterojunction devices is suppressed by unconventional doping at or near the heterointerface. The effect of this doping is to shift SRH generation and/or recombination preferentially into the wider band gap material of the heterojunction. This reduces total SRH generation and/or recombination in the device by decreasing the intrinsic carrier concentration ni at locations where most of the SRH generation and/or recombination occurs. The physical basis for this effect is that the SRH generation and/or recombination rate tends to decrease as ni around the depletion region decreases, so decreasing the effective ni in this manner is a way to decrease SRH recombination.

Santhanam, Parthiban↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wide-Input Voltage Range Two-Stages Auxiliary Power Supply for Medium Voltage Applications

This paper aims to present a two-stages auxiliary power supply (APS) providing 24 V output over a wide input DC voltage range, from 600 V to 2 kV. In this architecture, the medium voltage to low voltage scale is addressed by a simplified DC transformer (DCX) stage while the low voltage tight regulation is proposed to be accomplished in a cascaded second stage. Such architecture provides a simpler approach to the industry for the design of APS in MV applications. The implementation of main building blocks of the APS including the DCX stage, startup circuit and self-powered circuit is described. Experimental results at 1400 V and 100 W are presented.

Magri Kimpara, Marcio↗

Design of Auxiliary Power Supply for Medium Voltage Applications

Typical voltage levels from medium-voltage (MV) applications introduce additional challenges to designing the auxiliary power supply (APS) necessary to provide power to the secondary circuits of the main converter. This paper aims to present the design of a 100 W APS for 0.6–2 kV input DC voltage and 24 V output. The selected architecture addresses the medium voltage to low voltage challenge by adopting two stage approach – a simple robust DC transformer (DCX) stage and a low voltage regulation stage. The design of the main building blocks of the APS are described followed by simulation results.

Magri Kimpara, Marcio↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Medium-/Low-Voltage Joint State Estimator Through Linear Uncertainty Propagation

Traditionally, distribution system state estimations (DSSE) are challenged by the lack of measurements at both primary and secondary sides of the system. The widely available cable television (CATV) voltage sensors installed in low-voltage (LV) networks bring opportunities to achieve higher quality DSSE covering a broader area of the distribution network. This study proposes a medium-/low-voltage (MV/LV) joint distribution system state estimation approach using the untapped CATV measurements. It aims at addressing the need for system situational awareness at the grid edge while improving the estimation accuracy at both the primary and secondary sides compared to its disjointed counterpart. Linearized measurement functions and boundary condition uncertainty propagation rules are derived to ensure the computational efficiency and accuracy of the joint state estimator. Numerical experiments are conducted on an IEEE test feeder to demonstrate the efficacy of the proposed method and the value of CATV measurements.

joint state estimation↗

Scaling of pulsed nanosecond capillary plasmas at different specific energy deposition

Nano-second, capillary discharges (nCDs) are unique plasma sources in their ability to sustain high specific energy deposition ω dep approaching 10 eV/molecule in molecular gases. This high energy loading on short timescales produces both high plasma densities and high densities of molecular exited states. These high densities of electrons and excited states interact with each other during the early afterglow through electron collision quenching and associative ionization. In this paper we discuss results from a two-dimensional computational investigation of a nCD sustained in air at a pressure of 28.5 mbar and with a voltage amplitude 20 kV. Discharges were investigated for two circuit configurations—a floating low voltage electrode and with the low voltage electrode connected to ground through a ballast resistor. The first configuration produced a single ionization wave from the high to low voltage electrode. The second produced converging ionization waves beginning at both electrodes. With a decrease of the tube radius, the velocity of the ionization fronts decreased while the shape of the ionization wave changed from the electron density being distributed smoothly in the radial direction, to being hollow shaped where there is a higher electron density near the tube wall. For sufficiently small tubes, the near-wall maxima merge to have the higher density on the axis of the capillary tube. In the early afterglow, the temporal and radial behavior of the N 2 (C 3 Π u ) density is a sensitive function of ω dep due to electron collision quenching. Finally, these trends indicate that starting from ω dep $\geqslant$ 0.3 eV/molecule, it is necessary to take into account interactions of electrons with electronically excited species during the discharge and early afterglow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the Performance of SF6 Replacement Gases to Enable the Next Generation of Pulsed Power

High voltage switches are essential components in pulsed power systems, where consistent and reliable performance is crucial—particularly as the field explores alternatives to SF 6 as an insulating gas. This project examines the self-break voltage distributions of various gases, with a focus on the low-voltage discharges observed in the lower tail of these distributions. Experimental results revealed that the specific housing design influenced the self-break behavior. Among the tested gases, air demonstrated a more favorable overall distribution compared to SF 6 , albeit requiring higher operating pressures. However, air also exhibited a greater likelihood of extremely low-voltage dropouts, raising concerns about its suitability as a direct replacement for SF 6 . Notably, all gases tested showed a higher-than-expected probability of low-voltage events when considering the tail of the distribution rather than the bulk behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Dynamic Temperature-Sensitive Electrical Parameters for Medium-Voltage Low-Current Silicon Carbide and Silicon Devices

This paper presents five dynamic temperature-sensitive electrical parameters (TSEPs) for the medium-voltage silicon carbide (SiC) and silicon (Si) devices. The theoretical temperature dependence of these parameters is analyzed. A test platform that enables to implement the temperature relevant dynamic characterization is developed. The tested TSEPs are summarized in terms of their relationship with junction temperature, drain/collector current, DC voltage, and external gate resistance. The comparison between the 3 kV 12 A Si IGBT and 3.3 kV 5 A SiC MOSFET with the identical TO-263 package is conducted. The results verify that the turn-off drain-source voltage switching rate achieves better thermal sensitivity for medium-voltage low-current SiC MOSFETs compared with Si IGBTs. Both the turn-on and turn-off delay time exhibit better thermal linearity for the two devices. The turn-off delay time further achieves five times better thermal sensitivity than the turn-on delay time for investigated medium-voltage SiC MOSFETs.

Ni, Ze↗

Supervised Learning for Distribution Secondary Systems Modeling: Improving Solar Interconnection Processes

The current interconnection process and hosting capacity analysis for distributed energy resources (DERs), such as photovoltaics (PV) and battery energy storage systems, are based on analyzing grid network constraints (voltage and thermal) using only medium-voltage distribution network models. This is because most utilities do not have secondary low-voltage system models that connect service transformers and residential customers. This is important because in many cases the main impact of interconnecting DERs could occur on the low-voltage distribution systems. This paper proposes a supervised learning method to approximate local secondary models to improve the interconnection process. The proposed supervised learning method includes a decision tree model that predicts the secondary topology and a logistic regression model that predicts conductor types. The case studies demonstrate the benefits of including secondary low-voltage circuits in the interconnection process. We report the proposed modeling methodology is readily scalable and thus can reduce the cost and effort of PV interconnection for the industry and stakeholders.

14 SOLAR ENERGY↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method

Using electrochemical impedance spectroscopy, we have devised a method of sensing the microscopic surface conditions on the surface of niobium as it is undergoing an electrochemical polishing (EP) treatment. The method uses electrochemical impedance spectroscopy (EIS) to gather information on the surface state of the electrode without disrupting the polishing reaction. The EIS data is analyzed using a so-called distribution of relaxation times (DRT) method. Using DRT, the EIS data can be deconvolved into discrete relaxation time peaks without any a priori knowledge of the electrode dynamics. By analyzing the relaxation time peaks, we are able to distinguish two distinct modes of the EP reaction. As the polishing voltage is increased, the electrode transitions from the low voltage EP mode, characterized by a single relaxation time peaks, to the high voltage EP mode, characterized by two relaxation time peaks. We theorize that this second peak is caused by the formation of an oxide layer on the electrode. We also find that this oxide induced peak transitions from to a negative relaxation time, which is indicative of a blocking electrode process. By analyzing EPed samples, we show that samples polished in the low voltage mode have significantly higher surface roughness due to grain etching and faceting. We find that the surface roughness of the samples only improves when the oxide film peak is present and in the negative relaxation time region. This shows that EIS combined with DRT analysis can be used to predict etching on EPed Nb. This method can also be performed before or during the EP, which could allow for adjustment of polishing parameters to guarantee a smooth cavity surface finish.

43 PARTICLE ACCELERATORS↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of low-frequency voltage on nonlinear standing wave excitation, plasma uniformity, and ion dynamics in dual-frequency asymmetric capacitive discharges

Abstract It is known that in very-high-frequency (VHF) capacitively coupled plasmas, the higher harmonics generated by nonlinear sheath motion can enhance the standing wave effect (SWE), which can lead to center-peaked plasma density profiles. In this work, an improved nonlinear electromagnetic model incorporating a transmission line model, an electron momentum balance model, a bulk plasma model, a collisionless nonlinear numerical sheath model, and an ion Monte-Carlo collision (MCC) model is developed to study the effects of low-frequency (LF) voltage V L on the nonlinear standing wave excitation, plasma uniformity, and ion energy and angular distribution functions (IEDFs and IADFs) in dual-frequency (DF) asymmetric capacitive argon discharges at relatively low pressure of 3 Pa. The plasma diffusion in the radial direction and ion dynamics within the LF oscillating sheath are self-consistently considered. The LF voltage V L at 2 MHz varies from 0 to 700 V while the HF voltage V H at 60 MHz is fixed at 100 V. Simulation results indicate that without the addition of an LF source (i.e. V L = 0 V), there are a considerable number of high-order harmonics with short wavelengths, leading to significant SWE and central peak in the radial plasma density profile. Nevertheless, the high-order harmonic excitations tend to be weakened and merely occur around the phase of the full LF sheath collapse due to a shorter characteristic damping time of the surface waves as V L increases. This, combined with increased surface wavelengths of both the driving frequency and the higher harmonics at a higher V L , leads to suppressed standing waves and improved plasma uniformity. Meanwhile, the simulations show that both the low and the high energy peaks of IEDF move towards higher energies, and the energy peak separation width ΔEbecomes wider with the increase of V L . The IEDF at the radial center of the powered electrode exhibits a broader ΔEthan that at the edge. For the IADF, an increased V L results in more ions incident on the electrode with a smaller deflection angle. Because of a thinner sheath and a higher sheath voltage at the electrode center, the peak value of IADF at the electrode center is greater than that at the edge.

Physics↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗