Operation of hydrodynamic journal bearings in sodium at temperatures to 800 deg F and speeds to 12000 rpm
Operation of hydrodynamic journal bearings in liquid sodium at high temperatures and high speeds
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Operation of hydrodynamic journal bearings in liquid sodium at high temperatures and high speeds
Hydrodynamic journal bearings used in experiments on various materials and designs in liquid sodium at temperatures to 800 deg F
Controlled environment chamber for testing cavitation damage resistance of refractory alloys in pure liquid sodium
Cavitation damage resistance of refractory alloys in high temperature liquid sodium
Temperature effect on rate of cavitation damage of 316 stainless steel in pure liquid sodium at temperatures up to 1500 deg F
Concentration cell, based upon a thermally regenerative cell principle, produces electrical energy from any large heat source. This experimental bimetallic EMF cell uses a sodium-bismuth alloy cathode and a pure liquid sodium anode. The cell exhibits reliability, corrosion resistance, and high current density performance.
Hydrodynamic journal bearings in liquid sodium, discussing stability characteristics of different geometries and wear at high temperatures
Temperature and pressure effect on cobalt base alloy cavitation in liquid sodium, using vibratory apparatus and loss rate contour diagram
Self-seeking liquid sodium level and sodium impurity measurements for fast reactor test loop
A sodium storage and injection system for delivering atomized liquid sodium to a chemical reactor employed in the production of solar grade silicon is disclosed. The system is adapted to accommodate start-up, shut-down, normal and emergency operations, and is characterized by (1) a jacketed injection nozzle adapted to atomize liquefied sodium and (2) a supply circuit connected to the nozzle for delivering the liquefied sodium. The supply circuit is comprised of a plurality of replaceable sodium containment vessels, a pump interposed between the vessels and the nozzle, and a pressurizing circuit including a source of inert gas connected with the vessels for maintaining the sodium under pressure.
Size and weight reduced; operating lifetime increased. Developmental alkali-metal thermal-to-electric converter (AMTEC) in which cells fed from common supply of high-pressure sodium vapor and connected electrically in series. No liquid sodium makes contact with any part of AMTEC cells. Sodium vapor supplied to solid electrolyte of each cell through porous metal anode on upstream side. Proposed design reduces need for high-temperature feedthroughs in that cells internally connected. Power withdrawn through feedthrough at lower temperature without significant thermal loss.
Simple technique for producing silicon for solar cells employs solid sodium to reduce silicon fluoride. Since solid rather than liquid sodium is used, careful temperature control is unnecessary, and simple feed equipment is used. Technique is energy-efficient, since reaction produces enough heat to sustain itself.
Plots are presented which show the distribution of oxygen between liquid lithium and tantalum or niobium, and between liquid sodium and tantalum at elevated temperatures. Additional plots showing the composition of the gas phase above the solutions of oxygen and alkali metal are presented. The use of the plots is illustrated by an example tantalum heat pipe filled with lithium.
This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.
Sodium-sulfur batteries were identified as the most likely successor to nickel-hydrogen batteries for space applications. One advantage of the Na/S battery system is that the usable specific energy is two to three times that of nickel-hydrogen batteries. This represents a significant launch cost savings or increased payload mass capabilities. Sodium-sulfur batteries support NASA OAST's proposed Civil Space Technology Initiative goal of a factor of two improvement in spacecraft power system performance, as well as the proposed Spacecraft 2000 initiative. The sodium-sulfur battery operates at between 300 and 400 C, using liquid sodium and sulfur/polysulfide electrodes and solid ceramic electrolyte. The transport of the electrode materials to the surface of the electrolyte is through wicking/capillary forces. These critical transport functions must be demonstrated under actual microgravity conditions before sodium-sulfur batteries can be confidently utilized in space. Ford Aerospace Corporation, under contract to NASA Lewis Research Center, is currently working on the sodium-sulfur battery space flight experiment definition study. The objective is to design the experiment that will demonstrate operation of the sodium-sulfur battery/cell in the space environment with particular emphasis on evaluation of microgravity effects. Experimental payload definitions were completed and preliminary designs of the experiment were defined.
Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.
The sodium-cooled fast reactor (SFR) design concept is one of the six classes of nuclear reactors in the GenIV initiative. SFRs are uranium or plutonium-fueled reactors operating in the fast neutron spectrum using liquid sodium as the coolant. SFRs can be designed as a breeder reactor or actinide-burning reactor in addition to operating the thorium fuel cycle. While having different fuel designs, the anticipated waste streams, and the necessary management strategies for spent nuclear fuel (SNF) and radioactive wastes from SFRs are very similar. This includes the SNF, activated sodium coolant, in-core stainless-steel components, piping, resins and filters, solidified liquid waste, contaminated equipment, and other radioactive wastes. Modern SFR designs are based on a long and rich operating history of several liquid-metal-cooled fast reactors with sodium coolant. Several of these reactors have been shut down, the fuel has been placed in safe storage, and they have undergone some degree of decommissioning. As such, there is significant experience in the management of the SNF and radioactive wastes associated with operating these reactors. This white paper will identify the definitions and regulations that apply to the safe and secure management, storage, and disposal of radioactive waste and identify the key radioactive waste streams from SFRs. Idaho National Laboratory has significant experience in the management of the SNF from the SFR predecessors. This experience should form the basis for the management and disposition efforts of the radioactive waste from any new SFR-type small modular reactor or microreactor intended for deployment at the Idaho National Laboratory Site
Two heats of G91 steel have been investigated in liquid sodium at 550- 650°C to understand their corrosion behaviour, microstructural evolution, and tensile properties. Sodium exposure experiments of subsized, sheet-type tensile specimens of G91 were performed in Argonne’s forced convection sodium materials testing loops, SMT-1 and SMT-2. Maximum exposure times of ~49,000 h at ~38,000 h, and ~20,000 h have been achieved at 550, 600, and 650°C, respectively. Thermal aging experiments of G91 steel were also conducted in parallel, and the results were compared with those of the sodium-exposed specimens to isolate the effect of thermal aging from the effect of sodium exposure. It was found that the yield stress and ultimate tensile strength of G91 were reduced by more than 50% after sodium exposures at 650°C due to decarburization. The reduction in tensile strength was accompanied by the dissolution of M 23 C 6 carbides and excessive grain growth. The effect of sodium at 550 and 600°C was insignificant for exposure times up to ~49,000 h and ~38,000 h, respectively. The effect of sodium on the microstructural stability and tensile properties of G91 is largely dependent on the carbon mass transfer in the alloy-sodium system.