Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cooling Strategies for an Electric Motor with Additively Manufactured Hollow Conductors and Distributed Power Electronics Integrated with Heat Pipes

This paper discusses design tradeoffs and thermal modeling explored in cooling strategies for an aircraft propulsion electric motor with additively manufactured coils and distributed power electronics integrated with heat pipes. Design tradeoffs include heat pipe Qmax performance related to inclination, condenser configuration, coolant type, coolant flow path complexity, and ease of access to modular power electronics. Three cooling strategies were selected and realized into CAD models. These models were further evaluated using 3D thermal FEA and optimization tools to explore cooling geometry details that include fin thickness, spacing and count with the objective to minimize fin mass under a set of constraints. Lastly, motorette test data is presented comparing air versus liquid cooling of heat pipes.

additive manufacturing↗

Melting temperature of bismuth to 55 GPa using synchrotron X-ray phase contrast imaging

The melting temperature of elemental bismuth under high pressure has been measured to 55 GPa using synchrotron X-ray phase-contrast imaging in the laser-heated diamond anvil cell. Imaging of solid-liquid interface formation, combined with radiometric temperature and X-ray diffraction measurements, reveals a pronounced reduction in melting boundary slope in Bi-V with pressure. The unusually steep initial slope is attributed to low configurational entropy of melting, arising from structural ordering and coordination matching in the cool liquid, while slope reduction is driven by entropy increase correlated with significant liquid structure changes with rising pressure and temperature. Finally, the data rule out kinetic effects on melting in shock compression experiments and demonstrate the need for improved theoretical phase diagrams.

Materials science↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

Microstructure and mechanical behavior of a TiC nanoprecipitate strengthened V Alloy

The V-4Cr-4Ti (V44) alloys have been proposed as the prime candidate structural material for self-cooled liquid Li blanket and other designs for fusion energy applications. However, the applications of the V44 alloy are limited to a narrow operation temperature window, due to reduction in creep strength at or above 700 °C and susceptibility to irradiation hardening and embrittlement when irradiated below 400 °C. Here, in this work, we explore the feasibility of designing a novel V alloy to form a high number density of TiC nanoprecipitates, in order to simultaneously improve creep strength and provide defect sinks to mitigate irradiation hardening. Computational thermodynamics was used to design a new alloy (V44C) to achieve our goal of high TiC nanoprecipitates density within the alloy V44 matrix. To ensure scalability, the new alloy was made through arc-melting and ingot-casting followed by hot forging, cold rolling and heat treatments of homogenization and precipitation aging. The microstructure was characterized by SEM, TEM, XRD and APT, confirming the existence of nanoprecipitates predicted in the thermodynamic calculations. In addition to microstructural evaluation tensile properties at room temperature and 700 °C, and Charpy impact energy at room temperature were measured. The microstructure and mechanical properties were then compared with those from a historic reference V44 alloy. The tensile strength improvement in V44C was rationalized based on particle and solid solution strengthening mechanism. The fracture behavior was discussed based on the fractography results and necking deformation behavior.

Alloys development↗

Simulation of natural circulation cartridge loop experiments and application to molten salt reactors

This work uses the TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics (TH) code to model natural circulation cartridge loop experiments previously conducted at Oak Ridge National Laboratory (ORNL) using water and compares the simulated and experimental results. TRACE is also used to characterize natural circulation in the cartridge loop vehicle using FLiNaK as the working fluid. The experimental vehicle is a buoyancy-aided, annular cartridge loop, referred to as a thermosyphon, and is designed to aid in qualifying liquid–fueled and/or liquid–cooled irradiation experiments for the Versatile Test Reactor (VTR), which is currently being designed in the United States. Out-of-pile water experiments have been conducted using the cartridge and the Thermosyphon Test Loop facility at ORNL, and future experiments are anticipated that would use other molten salt surrogates as the working fluid, followed by eventual insertion of a similar cartridge into VTR. Additionally, this work aims to determine how well TRACE can replicate the natural convection conditions that were observed experimentally; this serves as an initial step for validating the modeling tool for design and safety calculations to support future irradiation experiments in VTR. Initial predictions of potential experiments were made using FLiNaK as the natural circulation fluid to demonstrate the relevance of the cartridge design to molten salt reactors (MSRs). Results from this study indicate that TRACE can accurately capture natural convection phenomena in the thermosyphon and that several design changes to the current cartridge vehicle are necessary to achieve hydraulic conditions similar to those expected in MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Generic Behavior of Ultrastability and Anisotropic Molecular Packing in Codeposited Organic Semiconductor Glass Mixtures

Vapor-deposited glass mixtures of organic semiconductors commonly serve as active layers in organic electronic devices, whose lifetime and performance are strongly influenced by the stability and structure of these mixed glasses. Here, we study the stability and anisotropic molecular packing of six co-deposited organic semiconductor glass mixtures with 50:50 weight ratio, by differential scanning calorimetry and spectroscopic ellipsometry. We also find that all six binary systems exhibit high kinetic stability and significantly reduced enthalpy relative to the corresponding liquid-cooled glassy mixtures (ultrastable behavior), even for systems where the glass transition temperatures of the components differ by more than 90 K. Furthermore, we demonstrate that the birefringence of a co-deposited glass mixture, a measure of its anisotropic packing, can be predicted from the birefringence of glasses of the two pure components. These results for stability and structure are expected to be applicable to other co-deposited organic semiconductor glass mixtures, so long as the two components mix well in the glass and individually can form ultrastable glasses. Therefore, our findings are significant for designing novel electronic devices with enhanced device lifetime and increased operational efficiency.

36 MATERIALS SCIENCE↗

Influence of the Nature of Aliphatic Hydrophobic Physical Crosslinks on Water Crystallization in Copolymer Hydrogels

The local environment within a hydrogel influences the properties of water, including the propensity for ice crystallization. Water-swollen amphiphilic copolymers produce tunable nanoscale environments, which are defined by hydrophobic associations, for the water molecules. In this work, the antifreeze properties for equilibrium-swollen amphiphilic copolymers with a common hydrophilic component, hydroxyethyl acrylate (HEA), but associated through crystalline (octadecyl acrylate, ODA) or rubbery (ethylhexyl acrylate, EHA) hydrophobic segments, are examined. Differences in the efficacy of the associations can be clearly enunciated from compositional solubility limits for the copolymers in water (<2.6 mol % ODA vs ≤14 mol % EHA), and these differences can be attributed to the strength of the association. The equilibrium-swollen HEA-ODA copolymers are viscoelastic solids, while the swollen HEA-EHA copolymers are viscoelastic liquids. Cooling these swollen copolymers to nearly 200 K induces some crystallization of the water, where the fraction of water frozen depends on the details of the nanostructure. Decreasing the mean free path of water by increasing the ODA composition from 10 to 25 mol % leads to fractionally more unfrozen water (66–87%). The swollen HEA-EHA copolymers only marginally inhibit ice (<13%) except with 45 mol % EHA, where nearly 60% of the water remains amorphous on cooling to 200 K. In general, the addition of the EHA leads to less effective ice inhibition than analogous covalently crosslinked HEA hydrogels (19.9 ± 1.8%). These results illustrate that fluidity of confining surfaces can provide pathways for critical nuclei to form and crystal growth to proceed.

36 MATERIALS SCIENCE↗

Crystallization of the P 3 Sn 4 Phase upon Cooling P 2 Sn 5 Liquid by Molecular Dynamics Simulation Using a Machine Learning Interatomic Potential

We performed molecular dynamics simulations to study the crystallization of the P3Sn4 phase from P 2 Sn 5 liquid using a machine learning (ML) interatomic potential with desirable efficiency and accuracy. Our results capture the liquid properties of P 2 Sn 5 at 1300 K, which is well above the melting temperature. The phase separation and crystallization are observed when P 2 Sn 5 liquid is cooled down below 832 and 505 K, respectively. The simulation results are in good agreement with the experimentally observed phase transformation behaviors and provide useful insights into the complex nucleation and crystallization process at the details of atomistic scale. Our work also demonstrated that ML interatomic potentials based on neural network deep learning are robust and capable of accurately describing the energetics and kinetics of complex materials through molecular dynamics simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The environmental footprint of data centers in the United States

Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.

54 ENVIRONMENTAL SCIENCES↗

Thermal Analysis of a 100 kW Polyphase Wireless Power Transfer System

Charging Electric Vehicles (EVs) fast and safely has a crucial role in the future of the EV technology. High-power Wireless Power Transfer (WPT) helps to significantly decrease the charging time. However, when the power transfer levels increase, thermal management becomes a significant challenge. The thermal design of the WPT systems needs more consideration in the design and implementation steps. This paper presents a thermal analysis of a 100 kW high-power WPT system. The thermal performance of the proposed design was evaluated at different power levels by considering the magnetic design and loss analysis. Finite Element Analysis (FEA) of the proposed design was performed and the thermal images of the implemented system were taken to prove the simulation results. The results show that, a liquid cooling design is needed for a high-power WPT systems for the long-time continuous operations of the charging pads.

Aydin, Emrullah↗

Surface Merging Technique to Design GA-Optimized Heat Sinks

High-power density inverters require efficient and small heat dissipation systems. For liquid cooling systems, an effective heat sink design is important to enable higher heat transfer and keep the pressure drop within reasonable limits. A heat sink geometry generated from an extruded, 1D fast Fourier transform can achieve more even temperature distribution and improved heat transfer than a conventional heat sink. Building on this concept, this paper proposes a new heat sink geometry creation algorithm. Instead of one plane profile being extruded, multiple plane profiles, each created from the fast Fourier transform method, are subsequently merged by smooth surfaces along the flow direction of the heat sink. Thus, a 3D heat sink geometry is created that enables 3D coolant flow and efficient heat transfer. The volume of this design was reduced by 50% compared with pin fin heat sinks. Compared with extruded 1D fast Fourier transform heat sinks, the proposed design showed an approximately 5% device temperature reduction and a 20% pressure drop reduction.

Barua, Himel↗

ExaDigiT/RAPS

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. RAPS either simulates workloads or replays historical workloads from system telemetry, and is able to predict dynamic energy consumption, as well as interact with the cooling model to predict cooling system behavior. Such a tool can be used together with reinforcement learning algorithms to provide an end-to-end optimization tool for data centers.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Reactors in Microgrids: Technology Modeling and Selection (Net-Zero Microgrid Program Project Report)

This report demonstrates the capabilities of the net-zero microgrid (NZM) Xendee platform for modeling an SR module with electricity, heat extraction and thermal storage in microgrids configurations. The model effectively captures the most important technical and economic considerations for SR technology specific analysis: cost and operational characteristics of SR technology and financial costs and incentives. The model can analyze multiple scenarios to establish metrics for cost-competitive and zero-carbon microgrids connected to the grid or completely isolated. The model is fully integrated within the Xendee platform for modeling and analysis of clean energy microgrids with storage and generation from renewable energy sources. The model captures the capabilities, constraints, and nuances of SR by incorporating parameters related to plant economics, design efficiency and performance, plant operation and component and fuel lifespan. The cost and operational parameters modeled in the SR module are specific to the technology selected for integration in the microgrid. Cost parameters recognize advanced nuclear technology for modular production and installation based on economies of scale from factory manufacture and related commissioning, and cost reduction through technology maturation—first-of-a-kind (FOAK) and nth-of-a-Kind (NOAK). The cost parameters include installation, operations and maintenance (O&M), fuel refueling cycle, and reactor life. Installation cost reflects economies of scale due to unit sizing at scale and colocation. O&M economies of scale for both fixed- and variable-cost fuel life-cycle costs are incurred at every refueling interval, with separate front- and back-end fuel costs, as well as waste-handling and disposition costs. This report investigates key characteristics of different SR technologies suitable for microgrid applications, including design principles, sizing, coolant properties, temperature ratings, fuel structures, and life-cycle considerations. This also includes fuel technologies applicable to these SR systems, alongside strategies for nuclear-waste and spent-fuel management and approaches to address safety, security, and proliferation challenges. Four primary groups of SR technologies are examined: water-cooled, liquid-metal-cooled, high-temperature gas-cooled, and molten-salt-cooled systems. In this report, an initial guideline for technology selection is established, aligning the characteristics of the technologies with the requirements of microgrids. The selection of technology in a microgrid is influenced by various factors, including financial capacity, location and accessibility, demand type and characteristics, reliability and resilience requirements, area constraints, and the lifespan of the microgrid. The types of electrical and non-electrical applications within the microgrid also play a significant role in technology selection. The characteristics of SRs, such as their smaller size, modularity, transportability, long refueling interval, improved safety features, ability to operate in autonomous or semi-autonomous mode, and provision of high-grade heat, are particularly appealing for microgrids. Furthermore, a list of considerations for implementing SRs in microgrids is outlined. The SR model is created to be continuously improved with the acquisition of actual data on investment and operational costs, experience with supply chains, production at scale, and field deployments. In the near term, performance data on applications in microgrids will become available from lessons learned from laboratory tests, such as those planned for the Microreactor Applications Research Validation and Evaluation Project (MARVEL), led by Idaho National Laboratory (INL). The SR model incorporates scenario data and known SR design specifications, enabling technoeconomic analysis for SR deployment in microgrids. It specifically considers the distinctive attributes of SRs as generators in technoeconomic studies. SRs can be modeled and analyzed with generation from renewable-energy sources, energy storage, and flexible loads over a range of functionality and applications. This offers a comprehensive tool for feasibility studies, scenario development, and sensitivity analysis for “what-if” consideration of any range of assumptions about SRs in microgrids and other aggregations of distributed-energy resources, including virtual power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗