Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear scaling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simple Two-Dimensional Corrections for One-Dimensional Pulse Tube Models

One-dimensional oscillating flow models are very useful for designing pulse tubes. They are simple to use, not computationally intensive, and the physical relationship between temperature, pressure and mass flow are easy to understand when used in conjunction with phasor diagrams. They do not possess, however, the ability to directly calculate thermal and momentum diffusion in the direction transverse to the oscillating flow. To account for transverse effects, lumped parameter corrections, which are obtained though experiment, must be used. Or two-dimensional solutions of the differential fluid equations must be obtained. A linear two-dimensional solution to the fluid equations has been obtained. The solution provides lumped parameter corrections for one-dimensional models. The model accounts for heat transfer and shear flow between the gas and the tube. The complex Nusselt number and complex shear wall are useful in describing these corrections, with phase relations and amplitudes scaled with the Prandtl and Valensi numbers. The calculated ratio, a, between a two-dimensional solution of the oscillating temperature and velocity and a one-dimensional solution for the same shows a scales linearly with Va for Va less than 30. In this region alpha less than 0.5, that is, the enthalpy flow calculated with a two-dimensional model is 50% of a calculation using a one-dimensional model. For Va greater than 250, alpha = 0.8, showing that diffusion is still important even when it is confined to a thing layer near the tube wall.

Lee, J. M.↗

Pole placement and order reduction in two-time-scale control systems through Riccati iteration

A transformation of variables taken from singular perturbations may be applied to two-time-scale linear systems in state space form to reduce the system to block-diagonal form with slow and fast modes decoupled. The transformation is easily computed by applying the new Riccati iteration. The iteration yields a solution to the nonsymmetric algebraic Riccati equation obtained by partitioning the original system matrix A. The numerical procedure is initiated with the trivial iterate L(0) = 0, and is globally convergent to the desired unique time scale decoupling solution. After transformation, the decoupled system may be used in controller design to achieve exact closed loop pole placement in the slow subsystem without altering the poles of the fast subsystem. The decoupled form may also be used to reduce system order by wetting a small parameter to zero. Provided the fast subsystem is stable, the order reduction can be expected to yield a good approximation to the original system. These methods are demonstrated using the 16th order linear model of a turbofan engine.

Anderson, L. R.↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

Ocular motor responses to abrupt interaural head translation in normal humans

We characterized the interaural translational vestibulo-ocular reflex (tVOR) in 6 normal humans to brief (approximately 200 ms), high-acceleration (0.4-1.4g) stimuli, while they fixed targets at 15 or 30 cm. The latency was 19 +/- 5 ms at 15-cm and 20 +/- 12 ms at 30-cm viewing. The gain was quantified using the ratio of actual to ideal behavior. The median position gain (at time of peak head velocity) was 0.38 and 0.37, and the median velocity gain, 0.52 and 0.62, at 15- and 30-cm viewing, respectively. These results suggest the tVOR scales proportionally at these viewing distances. Likewise, at both viewing distances, peak eye velocity scaled linearly with peak head velocity and gain was independent of peak head acceleration. A saccade commonly occurred in the compensatory direction, with a greater latency (165 vs. 145 ms) and lesser amplitude (1.8 vs. 3.2 deg) at 30- than 15-cm viewing. Even with saccades, the overall gain at the end of head movement was still considerably undercompensatory (medians 0.68 and 0.77 at 15- and 30-cm viewing). Monocular viewing was also assessed at 15-cm viewing. In 4 of 6 subjects, gains were the same as during binocular viewing and scaled closely with vergence angle. In sum the low tVOR gain and scaling of the response with viewing distance and head velocity extend previous results to higher acceleration stimuli. tVOR latency (approximately 20 ms) was lower than previously reported. Saccades are an integral part of the tVOR, and also scale with viewing distance.

Non-NASA Center↗

Dual-Frequency VLBI Study of Centaurus A on Sub-Parsec Scales: The Highest-Resolution View of an Extragalactic Jet

Centaurus A is the closest active galactic nucleus. High resolution imaging using Very Long Baseline Interferometry (VLBI) enables us to study the spectral and kinematic behavior of the radio jet-<:ounterjet system on sub-parsec scales, providing essential information for jet emission and formation models. Aims. Our aim is to study the structure and spectral shape of the emission from the central-parsec region of Cen A. Methods. As a target of the Southern Hemisphere VLBI monitoring program TANAMI (Tracking Active Galactic Nuclei with Millliarcsecond Interferometry), VLBI observations of Cen A are made regularly at 8.4 and 22.3 GHz with the Australian Long Baseline Array (LBA) and associated telescopes in Antarctica, Chile, and South Africa. Results. The first dual-frequency images of this source are presented along with the resulting spectral index map. An angular resolution of 0.4 mas x 0.7 mas is achieved at 8.4 GHz, corresponding to a linear scale of less than 0.013 pc. Hence, we obtain the highest resolution VLBI image of Cen A, comparable to previous space-VLBI observations. By combining with the 22.3 GHz image, we present the corresponding dual-frequency spectral index distribution along the sub-parsec scale jet revealing the putative emission regions for recently detected y-rays from the core region by Fermi/LAT. Conclusions. We resolve the innermost structure of the milliarcsecond scale jet and counter jet system of Cen A into discrete components. The simultaneous observations at two frequencies provide the highest resolved spectral index map of an AGN jet allowing us to identify up to four possible sites as the origin of the high energy emission. Key words. galaxies: active galaxies: individual (Centaurus A, NGC 5128) - galaxies: jets - techniques: high angular resolution

Mueller, C.↗

Multiparameter Flowfield Measurements in High-Pressure, Cryogenic Environments Using Femtosecond Lasers

Femtosecond laser electronic excitation tagging (FLEET) and Rayleigh scattering (RS) from a femtosecond laser are demonstrated in the NASA Langley 0.3-m Transonic Cryogenic Tunnel (TCT). The measured signals from these techniques are examined for their thermodynamic dependencies in pure nitrogen. The FLEET signal intensity and signal lifetimes are found to scale primarily with the gas density, as does the RS signal. Several models are developed, which capture these physical behaviors. Notably, the FLEET and Rayleigh scattering intensities scale linearly with the flow density, while the FLEET signal decay rates are a more complex function of the thermodynamic state of the gas. The measurement of various flow properties are demonstrated using these techniques. While density was directly measured from the signal intensities and FLEET signal lifetime, temperature and pressure were measured using the simultaneous FLEET velocity measurements while assuming the flow had a constant total enthalpy. Measurements of density, temperature, and pressure from the FLEET signal are made with accuracies as high as 5.3 percent, 0.62 percent, and 6.2 percent, respectively, while precisions were approximately 10 percent, 0.26 percent, and 11 percent for these same quantities. Similar measurements of density from Rayleigh scattering showed an overall accuracy of 3.5 percent and a precision of 10.2 percent over a limited temperature range (T greater than 195 K). These measurements suggest a high degree of utility at using the femtosecond-laser based diagnostics for making multiparameter measurements in high-pressure, cryogenic environments such as large-scale TCT facilities.

Burns, Ross A.↗

Development of a Liner Design Methodology and Relevant Results of Acoustic Suppression in the Farfield for Mixer-Ejector Nozzles

We have developed a process to predict noise field interior to the ejector and in the farfield for any liner design for a mixer-ejector of arbitrary scale factor. However, a number of assumptions, not verified for the current application, utilized in this process, introduce uncertainties in the final result, especially, on a quantitative basis. The normal impedance model for bulk with perforated facesheet is based on homogeneous foam materials of low resistivity. The impact of flow conditions for HSCT application as well as the impact of perforated facesheet on predicted impedance is not properly accounted. Based on the measured normal impedance for deeper bulk samples (i.e., 2.0 in.) the predicted reactance is much higher compared to the data at frequencies above 2 kHz for T-foam and 200 ppi SiC. The resistance is under predicted at lower frequencies (below 4 kHz) for these samples. Thus, the use of such predicted data in acoustic suppression is likely to introduce inaccuracies. It should be noted that the impedance prediction methods developed recently under liner technology program are not utilized in the studies described in this report due to the program closeout. Acoustic suppression prediction is based on the uniform flow and temperature conditions in a two-sided treated constant area rectangular duct. In addition, assumptions of equal energy per mode noise field and interaction of all frequencies with the treated surface for the entire ejector length may not be accurate. While, the use of acoustic transfer factor minimizes the inaccuracies associated with the prediction for a known test case, the assumption of the same factor for other liner designs and with different linear scale factor ejectors seems to be very optimistic. As illustrated in appendix D that the predicted noise suppression for LSM-1 is lower compared to the measured data is an indication of the above argument. However, the process seems to be more reliable when used for the same scale models for different liner designs as demonstrated for Gen. 1 mixer-ejectors.

Salikuddin, M.↗

Stress calculator speedily converts strain data

Stress calculator permits speedy conversion of strain data directly into maximum and minimum stresses and also determines stress direction. The calculator has a movable slide with logarithmic and linear scales, and an information and grid board. Its size is flexible for easy manipulation.

Cornett, D. W.↗

Linear convective modes and the energy transport in stellar convection zones.

Model stars whose convection zones had been prepared in accordance with the standard mixing-length theory were used as a basis for the computation of unstable convective modes. It was found that no superposition of statistically independent, nonviscous, adiabatic, convective modes can reproduce the radial dependence of the convective flux of the model. This implies that the representation of a stellar convection zone as a superposition of unstable adiabatic linear modes is inconsistent with the mixing-length theory, and that conclusions based upon such a representation should be regarded with caution. It is also shown that if the linear scale of convective motions is greater than (or of the same order as) the pressure scale height, then the fractional deviation of the pressure from equilibrium will generally not be negligible, as assumed in the mixing-length theory, but will be at least of the same order as the fractional deviation of the density from equilibrium.

Hart, M. H.↗

Stability region maximization by decomposition-aggregation method

This work is to improve the estimates of the stability regions by formulating and resolving a proper maximization problem. The solution of the problem provides the best estimate of the maximal value of the structural parameter and at the same time yields the optimum comparison system, which can be used to determine the degree of stability of the Skylab. The analysis procedure is completely computerized, resulting in a flexible and powerful tool for stability considerations of large-scale linear as well as nonlinear systems.

Siljak, D. D.↗

ASTP simulated lightning test report

A simulated lightning test was conducted on the backup spacecraft for the Apollo Soyuz Test Project mission (CSM-119) to determine the susceptibility of the Apollo spacecraft to damage from the indirect effects of lightning. It is demonstrated that induced lightning effects from low-level injected currents can be scaled linearly to those which are obtained in a full threat lightning stroke. Test results indicate that: (1) many of the power and signal critical circuits would fail if subjected to full-threat lightning, (2) pyrotechnic circuits are safe for full-threat lightning, and (3) common-mode voltages exceeded the failure criteria level for all but three of the circuits tested.

Blount, R. L.↗

Cold-air performance of a tip turbine designed to drive a lift fan. 1: Baseline performance

Full admission baseline performance was obtained for a 0.4 linear scale of the LF460 lift fan turbine over a range of speeds and pressure ratios without leakage air. These cold-air tests covered a range of speeds from 40 to 140 percent of design equivalent speed and a range of scroll inlet to diffuser exit static pressure ratios from 2.0 to 4.2. Results are presented in terms of specific work, torque, mass flow, efficiency, and total pressure drop.

Haas, J. E.↗

Cold air performance of a tip turbine designed to drive a lift fan. 2: Partial admission

Partial admission performance was obtained for a 0.4 linear scale version of the LF460 lift fan turbine over a range of speed from 40 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratio from 2.2 to 5.0. The investigation was conducted in two parts, with each part using a different side of the turbine scroll to simulate loss of a gas generator. Each side had an arc of admission of 180. Results are presented in terms of specific work, torque, mass flow, and efficiency.

Haas, J. E.↗

Direct reading inductance meter

A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.

Kolby, R. B.↗

Thoughts on standardization of parameters for image evaluation

Images received for image processing and analysis are obtained from a wide variety of sources and with a wide variety of sensors. Because it is desirable to have image processing algorithms be as universally applicable as possible, they should be designed, where possible, to be insensitive to the parametric variations of the source material. Where this is not possible, these variations must be taken into account. Therefore, it is necessary to consider what parameters may be defined in common across a suite of image types. Objective parameters or measurements of images which, in the proper combinations, may serve as surrogates for real images may be pixel-specific, location dependent, or combinations thereof. Parameters which have proven useful in defining the characteristics of images include the gray scale linearity, granularity of the quantization, spectral content, geometrical fidelity, resolution of the system expressed as either the point spread function or the modulation transfer function, and the spatial frequency content and characteristics of the data itself.

Billingsley, F. C.↗

Locally stabilizable large-scale systems

A class of large scale linear systems, stabilizable by local feedback control applied around each decoupled subsystem, is established. The control scheme, outlined in the paper, is based upon the decomposition-aggregation method, and involves only operations on the subsystem level. The systems, stabilized by the proposed method, have a tolerance to a wide class of non-linearities, and are reliable with respect to the structural perturbations.

Vukcevic, M. B.↗

Cold-air performance of a tip turbine designed to drive a lift fan

Performance was obtained over a range of speeds and pressure ratios for a 0.4 linear scale version of the LF460 lift fan turbine with the rotor radial tip clearance reduced to about 2.5 percent of the rotor blade height. These tests covered a range of speeds from 60 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratios from 2.6 to 4.2. Results are presented in terms of equivalent mass flow, equivalent torque, equivalent specific work, and efficiency.

Haas, J. E.↗

Cold-air performance of a tip turbine designed to drive a lift fan. 3: Effect of simulated fan leakage on turbine performance

Performance data were obtained experimentally for a 0.4 linear scale version of the LF460 lift fan turbine for a range of scroll inlet total to diffuser exit static pressure ratios at design equivalent speed with simulated fan leakage air. Tests were conducted for full and partial admission operation with three separate combinations of rotor inlet and rotor exit leakage air. Data were compared to the results obtained from previous investigations in which no leakage air was present. Results are presented in terms of mass flow, torque, and efficiency.

Haas, J. E.↗