Engineering PapersSearch

SEARCH · Engineering Papers

Results for “linear motor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The cable catapult - Putting it there and keeping it there

The cable catapult is the previously proposed method of using long space tethers for high speed interplanetary transport. A long conductive multistrand cable would be connected to a power supply and pointed in the desired direction. A linear motor would pull itself along the powered cable strands and launch a payload capsule toward a distant planet, where it would be caught and decelerated by another cable catapult positioned there. In this paper it is shown how cable catapults can be used to transport themselves to a distant planet and keep themselves in position near the planet despite the tendency of the payload capsule momentum transfer to push them apart.

Forward, Robert L.

Portable Linear Sled (PLS) for biomedical research

The PLS is a portable linear motion generating device conceived by researchers at Ames Research Center's Vestibular Research Facility and designed by engineers at Ames for the study of motion sickness in space. It is an extremely smooth apparatus, powered by linear motors and suspended on air bearings which ride on precision ground ceramic ways.

Vallotton, Will

Development of a Large Scale, High Speed Wheel Test Facility

Draper Laboratory, with its internal research and development budget, has for the past two years been funding a joint effort with the Massachusetts Institute of Technology (MIT) for the development of a large scale, high speed wheel test facility. This facility was developed to perform experiments and carry out evaluations on levitation and propulsion designs for MagLev systems currently under consideration. The facility was developed to rotate a large (2 meter) wheel which could operate with peripheral speeds of greater than 100 meters/second. The rim of the wheel was constructed of a non-magnetic, non-conductive composite material to avoid the generation of errors from spurious forces. A sensor package containing a multi-axis force and torque sensor mounted to the base of the station, provides a signal of the lift and drag forces on the package being tested. Position tables mounted on the station allow for the introduction of errors in real time. A computer controlled data acquisition system was developed around a Macintosh IIfx to record the test data and control the speed of the wheel. This paper describes the development of this test facility. A detailed description of the major components is presented. Recently completed tests carried out on a novel Electrodynamic (EDS) suspension system, developed by MIT as part of this joint effort are described and presented. Adaptation of this facility for linear motor and other propulsion and levitation testing is described.

Kondoleon, Anthony

An Orifice Pulse Tube Cooler for CMOS Computer Cooling

The subject orifice pulse tube cooler employs dual opposed compressor pistons, clearance seals, moving coil linear motors, and flexible bearings cooling capacity is 100 watts at 200 K. A matrix of optimizations explored load temperatures and cooling capacities of 50 K, 100 K, 200 K, 1 watt, 10 watts, and 100 watts. The optimization process resulted in a design with zero second entrance flow and a non-resonant pulse tube. Topics include performance results, mechanical design, and development problems and solutions. The development seeks to use orifice pulse tube mechanical simplicity to achieve a computer cooler with acceptable efficiency, low materials cost, low labor cost, long life, high reliability, low vibration, operation at the standard 60 Hz U.S. grid frequency, and control through simple drive and control electronics.

Riggle, P.

Operation of A Sunpower M87 Cryocooler In A Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMS-02) is an experiment that will be flown as an attached payload on the International Space Station to detect dark matter and antimatter. It uses large superconducting magnets cooled with superfluid helium to bend the path of cosmic particles through a series of detectors, which then measure the mass, speed, charge, and direction of the particles. Four Sunpower M87N Stirling-cycle cryocoolers are used to extend the mission life by cooling the outer vapor-cooled shield of the dewar. The main magnet coils are separated by a distance of approximately 1 m and the coolers are located approximately 1.5 m from the center line of the magnet, where the field is as high as 925 gauss perpendicular to the cryocooler axis and 400 gauss along the cryocooler axis. Interactions between the applied magnetic field and the linear motor may result in additional forces and torques on the compressor piston. Motion of the compressor arid displacer pistons through the magnetic field spatial gradients will generate eddy currents. Additional eddy currents are created during magnet charge, discharge, and quench by the time-varying magnetic field. The results of tests to determine the magnitude of the forces, torques, and heating effects, as well as the need for additional magnetic shielding, are presented.

Breon, S. R.

Qualifying the Sunpower M87N Cryocooler for Operation in the AMS-02 Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMs-02) experiment uses a superfluid helium dewar to cool a large superconducting magnet. The outer vapor-cooled shields of the dewar are to be held at 80 K by four Sunpower M87N cryocoolers. These cryocoolers have magnetic components that might interact with the external applied field generated by the superconducting magnet, thereby degrading the cryocoolers' performance. Engineering models of the Sunpower M87 have been qualified for operation in a magnetic environment similar to the AMs-02 magnetic environment. Although there was no noticeable performance degradation at field levels that were comparable to AMs-02 field levels, there appears to be a small performance degradation at higher field levels. It was theorized that there were three possible issues related to these performance losses at high magnetic fields: i) induced piston rubbing on the cylinder wall due to forces and torques on the linear motor due to the applied magnetic fields; ii) Magnetic hysteretic and/or eddy current damping of the balancer due to its motion in the applied magnetic fields; iii) Inductance losses in motor due to the applied magnetic field. The experiments conducted at the Massachusetts Institute of Technology (MIT) cyclotron facility in June 2002 were designed to test these. Tests were performed over a range of field levels that were lower, comparable, and higher than the field levels that the cryocoolers will experience in the AMs-02 operating environment. This paper describes the experiments and the inferences derived from them.

Mustafi, Shuvo

Support of NASA ADR/ Cross-Enterprise NRA Advanced Adiabatic Demagnetization Refrigerators for Continuous Cooling from 10K to 50mK, Development of a Heat Switch

Mechanical heat switches are used in conjunction with sorption refrigerators, adiabatic demagnetization refrigerators and for other cryogenic tasks including the pre-cooling cryogenic systems. They use a mechanical actuator which closes Au plated Cu jaws on an Au plated Cu bar. The thermal conductance in the closed position is essentially independent of the area of the jaws and proportional to the force applied. It varies linearly with T. It is approximately 10mW/K for 200 N at 1.5K. In some applications, the heat switch can be driven from outside the cryostat by a rotating rod and a screw. Such heat switches are available commercially from several sources. In other applications, including systems for space, it is desirable to drive the switch using a cold linear motor, or solenoid. Superconducting windings are used at temperatures s 4.2K to minimize power dissipation, but are not appropriate for pre-cooling a system at higher temperatures. This project was intended to improve the design of solenoid activated mechanical heat switches and to provide such switches as required to support the development of Advanced Adiabatic Demagnetization Refrigerators for Continuous Cooling from 10 K to 50 mK at GSFC. By the time funding began in 5/1/01, the immediate need for mechanical heat switches at GSFC had subsided but, at the same time, the opportunity had arisen to improve the design of mechanical heat switching by incorporating a "latching solenoid". In this device, the solenoid current is required only for changing the state of the switch and not during the whole time that the switch is closed.

Richards, Paul L.

The Interplay Between Strategic And Adaptive Control Mechanisms In Plastic Recalibration Of Locomotor Function

We have previously shown that viewing simulated rotary self-motion during treadmill locomotion causes immediate strategic modifications (Richards et al. 2004) as well as an after effect reflecting adaptive modification of the control of position and trajectory during over-ground locomotion (Mulavara et al. 2005). The process of sensorimotor adaptation is comprised of both strategic and adaptive control mechanisms. Strategic control involves cognitive, on-line corrections to limb movements once one is aware of a sensory discordance. Over an extended period of exposure to the sensory discordance, new strategic sensorimotor coordination patterns are reinforced until they become more automatic, and therefore adaptive, in nature. The objective of this study was to investigate how strategic changes in trunk control during exposure to simulated rotary self-motion during treadmill walking influences adaptive modification of locomotor heading direction during over-ground stepping. Subjects (n = 10) walked on a motorized linear treadmill while viewing a wide field-of-view virtual scene for 24 minutes. The scene was static for the first 4 minutes and then, for the last 20 minutes, depicted constant rate self-motion equivalent to walking in a counter-clockwise, circular path around the perimeter of a room. Subjects performed five stepping trials both before and after the exposure period to assess after effects. Results from our previous study showed a significant change in heading direction (HD) during post-exposure step tests that was opposite the direction in which the scene rotated during the adaptation period. For the present study, we quantified strategic modifications in trunk movement control during scene exposure using normalized root mean square (R(sub p)) variation of the subject's 3D trunk positions and normalized sum of standard deviations (R(sub o)) variation of 3D trunk orientations during scene rotation relative to that during static scene presentation. Associated 95% confidence intervals, CI(sub P) and CI(sub O), were calculated to investigate the variation of strategic modifications during scene exposure. Repeated measures ANOVA and individual subject regression analyses showed that R(sub P) and R(sub O) (i.e. strategic modifications) for trunk fore/aft (X) and yaw movements, respectively, decreased significantly over the exposure period. Furthermore, we found a significant correlation between the magnitude change in HD and the rate at which the variation of strategic modifications in trunk X decreased. We also found evidence of a correlation between HD and the rate at which strategic modifications in trunk yaw decreased (p = .06). We infer that adaptive recalibration of locomotor trajectory using optic flow stimuli depends on the rate at which strategic intervention is reduced.

Richards, J. T.

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.

Oscillating-Linear-Drive Vacuum Compressor for CO2

A vacuum compressor has been designed to compress CO2 from approximately equal to 1 psia (approximately equal to 6.9 kPa absolute pressure) to approximately equal to 75 psia (approximately equal to 0.52 MPa), to be insensitive to moisture, to have a long operational life, and to be lightweight, compact, and efficient. The compressor consists mainly of (1) a compression head that includes hydraulic diaphragms, a gas-compression diaphragm, and check valves; and (2) oscillating linear drive that includes a linear motor and a drive spring, through which compression force is applied to the hydraulic diaphragms. The motor is driven at the resonance vibrational frequency of the motor/spring/compression-head system, the compression head acting as a damper that takes energy out of the oscillation. The net effect of the oscillation is to cause cyclic expansion and contraction of the gas-compression diaphragm, and, hence, of the volume bounded by this diaphragm. One-way check valves admit gas into this volume from the low-pressure side during expansion and allow the gas to flow out to the high-pressure side during contraction. Fatigue data and the results of diaphragm stress calculations have been interpreted as signifying that the compressor can be expected to have an operational life of greater than 30 years with a confidence level of 99.9 percent.

Izenson, Michael G.

Apparatus and Methods for Mitigating Electromagnetic Emissions

Apparatus, methods, and other embodiments associated with mitigation of magnetic fields are described herein. In an embodiment, a method for mitigating an electromagnetic field includes positioning a mitigating coil around a linear alternator of linear motor so that the mitigating coil is coaxially located with an alternator coil; arranging the mitigating coil to generate a field to mitigate an electromagnetic field generated by the alternator coil; and passing an induced current from the alternator coil through the mitigating coil.

Geng, Steven M.

Apparatus and Methods for Mitigating Electromagnetic Emissions

Apparatus, methods, and other embodiments associated with mitigation of magnetic fields are described herein. In an embodiment, a method for mitigating an electromagnetic field includes positioning a mitigating coil around a linear alternator of linear motor so that the mitigating coil is coaxially located with an alternator coil; arranging the mitigating coil to generate a field to mitigate an electromagnetic field generated by the alternator coil; and passing an induced current from the alternator coil through the mitigating coil.

Geng, Steven M.

Active Vibration Reduction of the Advanced Stirling Convertor

Stirling Radioisotope Power Systems (RPS) are being developed as an option to provide power on future space science missions where robotic spacecraft will orbit, flyby, land or rove. A Stirling Radioisotope Generator (SRG) could offer space missions a more efficient power system that uses one fourth of the nuclear fuel and decreases the thermal footprint compared to the current state of the art. The Stirling Cycle Technology Development (SCTD) Project is funded by the RPS Program to developing Stirling-based subsystems, including convertors and controller maturation efforts that have resulted in high fidelity hardware like the Advanced Stirling Radioisotope Generator (ASRG), Advanced Stirling Convertor (ASC), and ASC Controller Unit (ACU). The SCTD Project also performs research to develop less mature technologies with a wide variety of objectives, including increasing temperature capability to enable new environments, improving system reliability or fault tolerance, reducing mass or size, and developing advanced concepts that are mission enabling. Active vibration reduction systems (AVRS), or "balancers", have historically been developed and characterized to provide fault tolerance for generator designs that incorporate dual-opposed Stirling convertors or enable single convertor, or small RPS, missions. Balancers reduce the dynamic disturbance forces created by the power piston and displacer internal moving components of a single operating convertor to meet spacecraft requirements for induced disturbance force. To improve fault tolerance for dual-opposed configurations and enable single convertor configurations, a breadboard AVRS was implemented on the Advanced Stirling Convertor (ASC). The AVRS included a linear motor, a motor mount, and a closed-loop controller able to balance out the transmitted peak dynamic disturbance using acceleration feedback. Test objectives included quantifying power and mass penalty and reduction in transmitted force over a range of ASC operating parameters and mounting conditions. All tests were performed at three different piston amplitudes, 3.0, 3.75, and 4.5 mm. Overall, the transmitted force was reduced to 2 percent of the total unbalanced force by actively balancing out only the first fundamental frequency, with balancer motor power remaining under 1 watt. The test results will be used to guide future balancer designs.

Balancer

Active Vibration Reduction of the Advanced Stirling Convertor

Stirling Radioisotope Power Systems (RPS) are being developed as an option to provide power on future space science missions where robotic spacecraft will orbit, flyby, land or rove. A Stirling Radioisotope Generator (SRG) could offer space missions a more efficient power system that uses one fourth of the nuclear fuel and decreases the thermal footprint compared to the current state of the art. The Stirling Cycle Technology Development (SCTD) Project is funded by the RPS Program to developing Stirling-based subsystems, including convertors and controller maturation efforts that have resulted in high fidelity hardware like the Advanced Stirling Radioisotope Generator (ASRG), Advanced Stirling Convertor (ASC), and ASC Controller Unit (ACU). The SCTD Project also performs research to develop less mature technologies with a wide variety of objectives, including increasing temperature capability to enable new environments, improving system reliability or fault tolerance, reducing mass or size, and developing advanced concepts that are mission enabling. Active vibration reduction systems (AVRS), or "balancers", have historically been developed and characterized to provide fault tolerance for generator designs that incorporate dual-opposed Stirling convertors or enable single convertor, or small RPS, missions. Balancers reduce the dynamic disturbance forces created by the power piston and displacer internal moving components of a single operating convertor to meet spacecraft requirements for induced disturbance force. To improve fault tolerance for dual-opposed configurations and enable single convertor configurations, a breadboard AVRS was implemented on the Advanced Stirling Convertor (ASC). The AVRS included a linear motor, a motor mount, and a closed-loop controller able to balance out the transmitted peak dynamic disturbance using acceleration feedback. Test objectives included quantifying power and mass penalty and reduction in transmitted force over a range of ASC operating parameters and mounting conditions. All tests were performed at three different piston amplitudes, 3.0 mm, 3.75 mm, and 4.5 mm. Overall, the transmitted force was reduced to 2% of the total unbalanced force by actively balancing out only the first fundamental frequency, with balancer motor power remaining under one watt. The test results will be used to guide future balancer designs.

Active Vibration Reduction

Swarm Flyby Gravimetry

This study describes a new technology for discerning the gravity fields and mass distribution of a solar system small body, without requiring dedicated orbiters or landers. Instead of a lander, a spacecraft releases a collection of small, simple probes during a flyby past an asteroid or comet. By tracking those probes from the host spacecraft, one can estimate the asteroid's gravity field and infer its underlying composition and structure. This approach offers a diverse measurement set,equivalent to planning and executing many independent and unique flyby encounters of a single spacecraft. This report assesses a feasible hardware implementation, derives the underlying models,and analyzes the performance of this concept via simulation.In terms of hardware, a small, low mass, low cost implementation is presented, which consists of a dispenser and probes. The dispenser contains roughly 12 probes in a tube and has a total size commensurate with a 6U P-Pod. The probes are housed in disc shaped sabots. When commanded,the dispenser ejects the top-most probe using a linear motor. The ejected probe separates from its sabots and unfolds using internal springs. There are two types of probes, each designed for a particular tracking modality. The reflective probe type, tracked by a telescope, unfolds to forma diffusely reflective sphere. The retroreflector probe type, tracked by a lidar, unfolds to form a corner-cube retroreflector assembly. Both types are designed to spherical so that their attitude doesn't affect the spacecraft's tracking performance.This analysis indicates that the point-mass term of small bodies larger than roughly 500 m in diameter can be observed from a host spacecraft that tracks locally deployed probes throughout a flyby to an uncertainty of better than 5%. The conditions by which this measurement is possible depends on the characteristics of the asteroid (size, type), the flyby velocity, and the type of tracking available (angles-only or angles+ranging). For most encounters, a few (1-3) well placed probes can be very effective, with marginal improvement for additional probes. Given realistic deployment errors, an encounter may require roughly 10-12 probes to ensure that 1-3 achieve their target. Long duration tracking of probes flying by large asteroids (>5 km diameter) can sometimes provide observability of the gravity field's first spherical harmonic, J( sub 2). In summary, this method offers a feasible, affordable approach to enabling or augmenting flyby science.

Atchison, Justin

Characterization of Infrared Optical Motion Tracking System in NASA's Simulated Lunar Operations (SLOPE) Laboratory

This work characterizes the accuracy of a 16 camera OptiTrack motion tracking system installed in NASA Glenn Research Center's Simulated Lunar Operations (SLOPE) laboratory. The position of a rigid body mounted on a motorized linear stage is compared to its position reported by the motion tracking system as it travels through the facility's 777m$^3$ capture volume of interest. Experiments show that the mean error reported by the motion tracking system for the aggregate capture volume is in-line with independent measurements collected using the motion stage. Error within regions of the capture volume exceed the mean error reported by the motion tracking system, likely due to occlusion, and suggests that additional cameras should be used to increase measurement accuracy in these regions. Overall, results show that error values reported by the motion tracking system are representative of the measurement error in a collected data set and validates the system's use for characterizing the mobility and tractive performance of robots, rovers, and other vehicles for planetary exploration.

Motion capture

A velocity command stepper motor for CSI application

The application of linear force actuators for vibration suppression of flexible structures has received much attention in recent years. A linear force actuator consists of a movable mass that is restrained such that its motion is linear. By application of a force to the mass, an equal and opposite reaction force can be applied to a structure. The use of an industrial linear stepper motor as a reaction mass actuator is described. With the linear stepper motor mounted on a simple test beam and the NASA Mini-Mast, output feedback of acceleration or displacement are used to augment the structural damping of the test articles. Significant increases in damping were obtained for both the test beam and the Mini-Mast.

Sulla, Jeffrey L.