Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Development of the Undulator Controls Module at the Linac Coherent Light Source

The Linac Coherent Light Source, LCLS, at the SLAC National Accelerator Laboratory, SNAL, is the first hard x-ray Free Electron Laser. The Undulator Controls Module, UCM, controls five cams and two translation stages that regulate the position of each of the 33 permanent undulator magnet segments within 10 microns. The UCM package, hardware and software, was designed and built by the Advanced Photon Source at Argonne. Important lessons were learned throughout the collaborative design, installation, testing, and commissioning periods that could be invaluable to future similar controls projects.

43 PARTICLE ACCELERATORS↗

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION↗

Study of an HHG-Seeded Free-Electron Laser for the LBNL Next Generation Light Source

The Next Generation Light Source (NGLS) is a high repetition rate free-electron laser facility proposed by Lawrence Berkeley National Laboratory (LBNL). The proposed facility will provide multiple FEL lines with varying spectral characteristics to satisfy a broad soft X-ray physics programme. At this stage of the project a number of FEL technologies and concepts are being investigated for possible implementation on the facility. In this report we consider a free-electron laser seeded by a Higher Harmonic Generation (HHG) source in which a high power (and consequently relatively low repetition rate) laser pulse is injected into a chamber of inert gas. Through a process of ionisation and recombination coherent higher harmonics of the laser are emitted from the gas and can be injected into an FEL system as a seed field. Further harmonic upconversion can be done within the FEL system to enable temporally coherent FEL output at wavelengths much shorter than, and pulse energies orders of magnitude higher than, the HHG source emission. The harmonic conversion within the FEL works in the following way. The seed field induces an energy modulation within the electron bunch at the start of the modulator. This energy modulation grows within the modulator due to the FEL interaction and starts to convert into a density modulation, or bunching, at the seed wavelength. However, this bunching also has components at higher harmonics which retain the longitudinal coherence of the initial seed. The beam passes through a magnetic chicane, which shears the longitudinal phase space to maximise the bunching at the required harmonic, then a further undulator which is tuned to this harmonic. If this second undulator is short it acts as a further modulator, and because the beam is pre-bunched at the modulator resonance there is a strong coherent burst of radiation which acts to modulate the electron beam energy in much the same way the input laser seed field acted in the first modulator. This second modulator is followed by a second bunching chicane and then a final long radiator tuned to a yet higher harmonic of the laser seed - the final output wavelength. Alternatively, the second undulator can be the radiator itself, in which case only one harmonic conversion from seed wavelength to final output is necessary. We initially consider the case of a 400kW peak power HHG seed source at wavelength 12nm (currently considered the cutoff wavelength for sufficient seed power to dominate shot noise in the electron beam) which is converted in either one or two stages or harmonic conversion to FEL emission at 1nm. We then consider the implications of a factor of ten reduction in seed power to 40kW.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

43 PARTICLE ACCELERATORS↗

High Pressure Research at the National Synchrotron Light Source

The National Synchrotron Light Source at Brookhaven National Laboratory has been home to a successful high-pressure program for over 20 years. The first dedicated high-pressure diffraction endstation, X17C, was etablished at NSLS in 1990. A large number of new techniques have been developed at this beamline, including double-sided laser heating, single crystal diffraction above 60 GPa, x-ray diffraction measurements in a resistive heated diamond anvil cell (DAC) at 1300 K and 1 megabar, the first high-pressure and low-temperature experiment, and radial diffraction in a DAC.

43 PARTICLE ACCELERATORS↗

Measurements and Simulations of Ultra-Low Emittance and Ultra-Short Electron Beams in the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is an x-ray Free-Electron Laser (FEL) project presently in a commissioning phase at SLAC. We report here on very low emittance measurements made at low bunch charge, and a few femtosecond bunch length produced by the LCLS bunch compressors. Start-to-end simulations associated with these beam parameters show the possibilities of generating hundreds of GW at 1.5 {angstrom} x-ray wavelength and nearly a single longitudinally spike at 1.5 nm with 2-fs duration.

43 PARTICLE ACCELERATORS↗

Measurements and Simulations of Ultralow Emittance and Ultrashort Electron Beams in the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser project presently in a commissioning phase at the SLAC National Accelerator Laboratory. We report here on very low-emittance measurements made at low bunch charge, and a few femtosecond bunch length produced by the LCLS bunch compressors. Start-to-end simulations associated with these beam parameters show the possibilities of generating hundreds of GW at 1.5 A ring x-ray wavelength and nearly a single longitudinally coherent spike at 1.5 nm with 2-fs duration.

43 PARTICLE ACCELERATORS↗

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

43 PARTICLE ACCELERATORS↗

Second and Third Harmonic Measurements at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) started user commissioning in October of 2009, producing Free Electron Laser (FEL) radiation between 800 eV and 8 keV [1]. The fundamental wavelength of the FEL dominates radiation in the beamlines, but the beam also produces nonnegligible levels of radiation at higher harmonics. The harmonics may be desirable as a source of harder X-rays, but may also contribute backgrounds to user experiments. In this paper we present preliminary measurements of the second and third harmonic content in the FEL. We also measure the photon energy cutoff of the soft X-ray mirrors to determine the extent to which higher harmonics reach the experimental stations. We present preliminary second and third harmonic measurements for LCLS. At low energies (below 1 keV fundamental) we measure less than 0.1% second harmonic content. The second harmonic will be present in the soft X-ray beam line for fundamental photon energies below approximately 1.1 keV. At low and high energies, we measure third harmonic content ranging from 0.5% to 3%, which is consistent with expectations. For both second and third harmonics, experimental work is ongoing. More rigorous analysis of the data will be completed soon.

43 PARTICLE ACCELERATORS↗

The Effect of Spectral Resolution of Light Sources on Photopic and a-opic Quantities

There is a growing interest in including light source spectrum in advanced lighting software tools and simulations. Given that traditional lighting software tools have been used primarily for calculating photometric quantities, their simplifying assumptions may not be suitable for calculating other a-opic quantities. Commonly used simulation tools use three values to represent the three primary colors (red, green, and blue), but others have expanded the number of bands (i.e., the spectral resolution) to 9, 27, or 81 in an attempt to more accurately represent variations in light source spectrum and downstream spectrally-derived quantities. It remains unclear, however, to what extent spectral resolution affects calculated quantities. To address this gap, a numerical analysis was completed using a large spectral power distribution database (n = 1,302 light sources). Calculated illuminance, a-opic irradiance, luminous efficacy of radiation (LER), melanopic efficacy of radiation (MER), and melanopic to photopic (M/P) ratio were compared for spectral resolutions of 3 and 9 bands compared to a baseline of 81 bands. Across all examined lighting quantities, considerable errors—a mean absolute percent error of 18.4%—were found when using 3 band calculations. These were reduced to 4% for 9 band calculations. The errors varied by metric and light source type. The results suggest that the use of 9 bands can more accurately characterize performance of different light source types across a range of metrics compared to using 3 bands.

Abboushi, Belal K.↗

The Development of the Linac Coherent Light Source RF Gun

The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of the emittance compensation solenoid are discussed in Section 1.1.7. The novel feature of the LCLS solenoid is the embedded quadrupole correctors. The thermo-mechanical engineering of the LCLS gun is discussed in Section 1.1.8, and the cold and hot RF tests are described in Section 1.1.9. The results of this work are summarized and concluding remarks are given in Section 1.1.10.

43 PARTICLE ACCELERATORS↗

Intense X-ray and EUV light source

An intense X-ray or EUV light source may be driven by the Smith-Purcell effect. The intense light source may utilize intense electron beams and Bragg crystals. This may allow the intense light source to range from the extreme UV range up to the hard X-ray range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Resonant metasurface‐enabled quantum light sources for single‐photon emission and entangled photon‐pair generation

Light encodes information in multiple degrees of freedom (e.g., frequency, amplitude, and phase), enabling high‐speed, high‐bandwidth communication through fiber optics. Unlike classical light, quantum light (single or entangled photons) can transmit quantum states over long distances without loss of coherence, thereby coherently interconnecting quantum nodes for distributed quantum entanglement. Quantum light sources are critical for developing scalable quantum networks aimed at distributed quantum computing, quantum teleportation, and secure quantum communications. However, existing quantum light sources suffer from limited integrability, insufficient spectral and spatial tunability, and inefficiencies in achieving mass‐produced, deterministic, on‐demand quantum light generation. These limitations significantly hinder progress toward direct, on‐chip integration with quantum processing units and detectors – an essential step toward scalable quantum networks. Resonant metasurfaces that leverage photonic modes – such as Mie resonances, guided‐mode resonances, or symmetry‐protected bound states in the continuum – offer strong spatial and temporal confinement of electromagnetic fields, characterized by high quality factors and small mode volumes. These metasurfaces greatly enhance linear and nonlinear light‐matter interactions, making them ideal for efficient on‐chip quantum light generation and manipulation. Here, we describe recent advances in nanoscale quantum light sources and quantum photonic state manipulation enabled by resonant metasurfaces. We also provide an outlook on next‐generation miniaturized quantum light sources achievable through materials innovations in quantum emitters, the co‐design of resonant metasurfaces, and ultimately, the heterogeneous integration of emerging layered van der Waals materials with resonant metasurfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron light sources in developing countries

Here, we discuss the role that synchrotron light sources, such as SESAME, could play in improving the socioeconomic conditions in developing countries. After providing a brief description of a synchrotron light source, we discuss the important role that they played in the development of several economically emerging countries. Then we describe the state of synchrotron science in South Africa and that country’s leadership role in founding the African Light Source initiative. Next, we highlight a new initiative called Lightsources for Africa, the Americas & Middle East Project, which is a global initiative led by the International Union of Pure and Applied Physics and the International Union of Crystallography, with initial funding provided by the International Council for Science. Finally, we comment on a new technology called the multibend achromat that has launched a new paradigm for the design of synchrotron light sources that should be attractive for construction in developing countries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A double bend achromat lattice for the Pohang Light Source to reduce emittance and increase number of insertion devices

The Pohang Light Source (PLS) storage ring is a synchrotron light source with the emittance of 18.9 nm at 2.5 GeV and has delivered vacuum ultraviolet and soft x-rays during the past 15 years. We investigate a lattice design for the 3 GeV ring for an upgrade project that keeps the existing tunnel. We investigate a double bend achromat (DBA) structure that provides the reduction of emittance by a factor of 3 and the increase of the number of straight section by a factor of 2 than the existing PLS lattice. We present several characteristics on the beam dynamics, dynamic aperture, and optics matching in the low-emittance lattice which includes squeezed space between magnets. Present PLS lattice has 12 long straight sections of 6.8 m long and the lattice is modified to provide the additional 12 short straight sections of 3.7 m long by eliminating a bending magnet in the middle of the cell of the present triplet bending achromat lattice. Thus, the new lattice consists of a total of 24 straight sections that consist of 12x6.8 and 12x3.7 m long straight sections, which can provide the spaces for the 4- and 2-m-long insertion devices. We present the design results in detail for a DBA lattice in 281.82 m long circumference. It is shown that the emittance of 6.2 nm in the lattice can be achieved by allowing nonzero dispersions in the straight sections. The lattice provides high brilliance at the photon energy of a few 10 keV that meets the requirements by synchrotron radiation users; however, it may require a strong focusing and become sensitive to machine errors and effects of insertion devices. Thus, we investigated the dynamic aperture in the lattice by a simulation method and achieved an optimal tune under the strength of sextupole magnets of 500 T/m{sup 2} for the low-emittance ring. We also performed the lattice tunings to restore the optics due to the errors in the low-emittance ring. In result, our designed lattice shows a good optimization in terms of emittance, brilliance, and circumference as a light source for a 3 GeV.

43 PARTICLE ACCELERATORS↗

Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity

Synchrotron light sources are key instruments of modern science, providing unique opportunities for groundbreaking studies in diverse scientific disciplines and driving innovation in numerous scientific and technological fields. Fourth-generation light sources provide unprecedented capabilities in imaging, spectroscopy and diffraction techniques. Ultimate brightness is the key to advancing to a smaller scale, faster response, and higher data measurement and processing rate. The brightness is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of the electron bunches combined with a very small transverse beam size. Consequently, the high particle density leads to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance and brightness scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction and bunch lengthening provided by higher-harmonic RF systems to identify optimal combinations of machine and beam parameters.

36 MATERIALS SCIENCE↗

Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source

The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. This entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project’s resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed in this paper. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Finally, post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗