Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser mode locking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Self-mode-locked chromium-doped forsterite laser generates 50-fs pulses

Stable transform-limited (delta nu-delta tau = 0.32) femtosecond pulses with a FWHM of 50 fs were generated from a self-mode-locked chromium-doped forsterite laser. The forsterite laser was synchronously pumped by a CW mode-locked Nd:YAG (82 MHz) laser that generated picosecond pulses (200-300 ps) and provided the starting mechanism for self-mode-locked operation. Maximum output power was 45 mW for 3.9 W of absorbed pumped power with the use of an output coupler with 1 percent transmission. The self-mode-locked forsterite laser was tuned from 1240 to 1270 nm.

Seas, A.↗

Coupled-mode analysis of phase-locked injection laser arrays

A coupled-mode analysis has been developed to describe the output of phase-locked injection laser arrays. It is shown that an array of emitters with weak coupling can only operate in a set of discrete modes determined by the number of and the spacing of the emitters. The interaction between emitters leads to a splitting of the common frequency of operation that can be estimated from the coupling strength. The coupled-mode analysis is compared to calculations based on simple diffraction theory. A consequence of the analysis is an explanation for the commonly observed discrepancy between experimentally observed far-field lobe widths and those predicted by simple diffraction theory.

Butler, J. K.↗

Mode-locked frequency doubled Nd:YAG laser

The design, fabrication, test, and delivery of two mode-locked, frequency doubled Nd:YAG laser systems are described. Each system was comprised of two units, the laser head and optics on an Invar plate and the electronics control unit in a relay rack chassis panel. Laser number one operated at a repetition rate of 400 MHz and was designed for use in an optical communication system. Laser number two operated at 200 MHz repetition rate and was designed for optical ranging and target signature experiments. Both lasers had a pulse width of 200 ps at the 10% amplitude points at 1.064 micrometer wavelength (150 ps at 0.532 micrometers) with an amplitude stability of + or - 4%. Output power exceeded the design goals.

Brookman, J. S.↗

Coupled Opto-Electronic Oscillators

These experiments demonstrate that COEOs are promising compact sources for generating low jitter optical pulses and low phase noise RF/millimeter wave signals.

opto-electronic oscillator (COEO) ring laser mode-↗

Tetravalent chromium (Cr(4+)) as laser-active ion for tunable solid-state lasers

Major accomplishments under NASA grant NAG-1-1346 are summarized. (1) numerical modeling of the four mirror astigmatically compensated, Z-fold cavity was performed and several design parameters to be used for the construction of a femtosecond forsterite laser were revealed by simulation. (2) femtosecond pulses from a continuous wave mode-locked chromium doped forsterite laser were generated. The forsterite laser was actively mode-locked using an acousto-optic modulator operating at 78 MHz with two Brewster high dispersion glass prisms for intra-cavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(sub 00) mode with 85 mW of continuous power tunable over 1230-1280 nm. The shortest pulses of 60-fs pulsewidth were measured. (3) Self-mode-locked operation of the Cr:forsterite laser was achieved. Synchronous pumping was used to mode lock the forsterite laser resulting in picosecond pulses, which in turn provided the starting mechanism for self-mode-locking. The pulses generated had an FWHM of 105 fs and were tunable between 1230-1270 nm. (4) Numerical calculations indicated that the pair of SF 14 prisms used in the cavity compensated for quadratic phase but introduced a large cubic phase term. Further calculations of other optical glasses indicated that a pair of SFN 64 prisms can introduce the same amount of quadratic phase as SF 14 prisms but introduce a smaller cubic phase. When the SF 14 prisms were replaced by SFN 64 prisms the pulsewidth was reduced to 50 fs. Great improvement was observed in the stability of the self mode-locked forsterite laser and in the ease of achieving mode locking. Using the same experimental arrangement and a new forsterite crystal with improved FOM the pulse width was reduced to 36 fs.

Seas, A.↗

Spatially coherent beam formation and mode locking of an array of solid-state lasers

A study is reported on the spatially coherent beam formation from an array of four Nd-glass lasers and on mode locking of their longitudinal modes. The results indicate a nearly 16 times increase in radiance. For mode locking, only a single modulator is required. A spatial filter in the optical cavity performs the spatially coherent beam formation and the precision synchronization of the mode-locked pulses at the output mirror of the optical cavity.

Philipp-Rutz, E. M.↗

New progress of ranging technology at Wuhan Satellite Laser Ranging Station

A satellite laser ranging system with an accuracy of the level of centimeter has been successfully developed at the Institute of Seismology, State Seismological Bureau with the cooperation of the Institute of Geodesy and Geophysics, Chinese Academy of Science. With significant improvements on the base of the second generation SLR system developed in 1985, ranging accuracy of the new system has been upgraded from 15 cm to 3-4 cm. Measuring range has also been expanded, so that the ETALON satellite with an orbit height of 20,000 km launched by the former U.S.S.R. can now be tracked. Compared with the 2nd generation SLR system, the newly developed system has the following improvements. A Q modulated laser is replaced by a mode-locked YAG laser. The new device has a pulse width of 150 ps and a repetition rate of 1-4 pps. A quick response photomultiplier has been adopted as the receiver for echo; for example, the adoption of the MCP tube has obviously reduced the jitter error of the transit time and has improved the ranging accuracy. The whole system is controlled by an IBM PC/XT Computer to guide automatic tracking and measurement. It can carry out these functions for satellite orbit calculation, real-time tracking and adjusting, data acquisition and the preprocessed of observing data, etc. The automatization level and reliability of the observation have obviously improved.

Xia, Zhiz-Hong↗

High-accuracy range measurements to the moon

The lunar ranging station at the University of Texas McDonald Observatory has made more than 1800 range measurements to the four lunar retroreflectors during the first six years of its operation. Each range consists of a normal point constructed of from 5 to 20 single photoelectron returns. Normal point accuracies to about four parts in 10 to the tenth plus or minus 10 cm have become routine. The availability of excellent commercial timing equipment means that the error for such a measurement is primarily dependent on the width of the transmitted laser pulse. Second generation systems using mode-locked subnanosecond lasers can probably achieve routine normal point accuracies approaching one part in 10 to the tenth plus or minus 2 cm. High speed pockel cells may permit such accuracies to be realized with conventional Q-switched lasers.

Silverberg, E. C.↗

Ultrastable Multigigahertz Photonic Oscillator

Novel photonic oscillator developed to serve as ultrastable source of microwave and millimeter-wave signals. In system, oscillations generated photonically, then converted to electronic form. Includes self-mode-locked semiconductor laser producing stream of pulses, detected and fed back to laser as input. System also includes fiber-optic-delay-line discriminator, which detects fluctuations of self-mode-locking frequency and generates error signal used in negative-feedback loop to stabilize pulse-repetition frequency.

Logan, Ronald T., Jr.↗

Analysis of mode-locked and intracavity frequency-doubled Nd:YAG laser

The paper presents analytical and computer studies of the CW mode-locked and intracavity frequency-doubled Nd:YAG laser which provide new insight into the operation, including the detuning behavior, of this type of laser. Computer solutions show that the steady-state pulse shape for this laser is much closer to a truncated cosine than to a Gaussian; there is little spectral broadening for on-resonance operation; and the chirp is negligible. This leads to a simplified analytical model carried out entirely in the time domain, with atomic linewidth effects ignored. Simple analytical results for on-resonance pulse shape, pulse width, signal intensity, and harmonic conversion efficiency in terms of basic laser parameters are derived from this model. A simplified physical description of the detuning behavior is also developed. Agreement is found with experimental studies showing that the pulsewidth decreases as the modulation frequency is detuned off resonance; the harmonic power output initially increases and then decreases; and the pulse shape develops a sharp-edged asymmetry of opposite sense for opposite signs of detuning.

Siegman, A. E.↗

Gated high speed optical detector

The design, fabrication, and test of two gated, high speed optical detectors for use in high speed digital laser communication links are discussed. The optical detectors used a dynamic crossed field photomultiplier and electronics including dc bias and RF drive circuits, automatic remote synchronization circuits, automatic gain control circuits, and threshold detection circuits. The equipment is used to detect binary encoded signals from a mode locked neodynium laser.

Green, S. I.↗

Tunable single-longitudinal-mode operation of an injection-locked TEA CO2 laser

The tunable single-longitudinal-mode operation of a TEA CO2 laser by an injection technique using a CW waveguide laser as the master oscillator is reported. With the experimental arrangement described, in which the waveguide laser frequency is tuned to correspond to one of the oscillating longitudinal modes of the TEA laser, single-longitudinal-mode operation was achieved with no apparent reduction in the TEA output energy, on various CO2 lines with frequency offsets from the line center as large as 300 MHz. The capability of this technique for high-resolution spectroscopy or atmospheric lidar studies is demonstrated by the recording of the absorption spectrum of a strong ozone line.

Megie, G.↗

Picosecond coherent anti-Stokes Raman scattering (CARS) study of vibrational dephasing of carbon disulfide and benzene in solution

The vibrational dephasing of the 656/cm mode (nu1, a1g) of CS2 and the 991/cm mode (nu2, a1g) of benzene have been studied as a function of concentration in mixtures with a number of solvents using a ps time-resolved CARS technique. This technique employs two tunable synchronously-pumped mode-locked dye lasers in a stimulated Raman pump, coherent anti-Stokes Raman probe time-resolved experiment. Results are obtained for CS2 in carbon tetrachloride, benzene, nitrobenzene, and ethanol and for benzene nu2 in CS2. The dephasing rates of CS2 nu1 increase on dilution with the polar solvents and decrease or remain constant on dilution with the nonpolar solvents. The CS2/benzene solutions show a contrasting behavior, with the CS2 nu1 dephasing rate being nearly independent of concentration whereas the benzene nu2 dephasing rate decreases on dilution. These results are compared to theoretical models for vibrational dephasing of polyatomic molecules in solution.

Perry, Joseph W.↗