Detection of lack of fusion using opaque additives, phase 1
Two major problems in welded aluminum spacecraft structure, reliable nondestructive inspection for incomplete weldment penetration and the rapid oxidation of aluminum surfaces left exposed to the atmosphere are investigated. The approach employed to solve both problems was to employ copper as a coating to prevent oxidation of the aluminum and as an opaque additive in the weldment to enhance X-ray detection in the event of incomplete penetration. Both plasma spray and vacuum vapor deposition techniques were evaluated for depositing the copper. A series of welded panels was made using three thicknesses of vacuum-vapor-deposited copper. All weldments were nondestructively inspected by X-ray, then excised into tensile and bend specimens. Mechanical tests were conducted and all data evaluated. It was determined that the vacuum-vapor-deposited coating was superior to a plasma sprayed coating of the same thickness. The vacuum-vapor-deposited coating was more uniform in thickness, provided complete coverage of the aluminum, and was free of cracks and porosity.