A study on the high-order mode oscillation in a four-cavity intense relativistic klystron amplifier

The high-order mode oscillation is studied in designing a four-cavity intense relativistic klystron amplifier. The reason for the oscillation caused by high-order modes and a method to suppress these kinds of spurious modes are found through theoretical analyses and the study on the influence of major parameters of a high frequency structure (such as the oscillation frequency of cavities, the cavity Q value, the length of drift tube section, and the characteristic impedance). Based on much simulation, a four-cavity intense relativistic klystron amplifier with a superior performance has been designed, built, and tested. An output power of 2.22 GW corresponding to 27.4% efficiency and 61 dB gain has been obtained. Moreover, the high-order mode oscillation is suppressed effectively, and an output power of 1.95 GW corresponding to 26% efficiency and 62 dB gain has been obtained in our laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 75 MW S-Band Klystron

This program performed computational and preliminary mechanical design for a klystron producing 75 MW at 2.856 GHz using periodic permanent magnet (PPM) focusing. The performance specifications achieved were those for the Matter-Radiation Interactions in the Extremes (MaRIE) project at Los Alamos National Laboratory. The klystron is designed to provide 10 microsecond pulses at 60 Hz with 56 dB gain. The PPM-Focusing eliminates requirements for solenoids and their associated power supplies, cooling systems, interlocks, control and diagnostic instrumentation, and maintenance. The represents a significant in both acquisition and operating costs. It also increases reliability by eliminating many potential failure modes.

43 PARTICLE ACCELERATORS↗

SPALLATION NEUTRON SOURCE SUPERCONDUCTING LINAC KLYSTRON TO CAVITY MISMATCH EFFECTS AND COMPENSATION*

Abstract Observations of several of the 81 klystron output waveforms into their respective superconducting cavities do not correspond with their rectangular klystron inputs in open loop mode. This can't be completely explained by a drooping high voltage power supply especially when the waveform is parabolic. Some possible causes and effects of these anomalies are presented.

circulator↗

Final Design of the SLAC P2 Marx Klystron Modulator

The SLAC P2 Marx has been under development for two years, and follows on the P1 Marx as an alternative to the baseline klystron modulator for the International Linear Collider. The P2 Marx utilizes a redundant architecture, air-insulation, a control system with abundant diagnostic access, and a novel nested droop correction scheme. This paper is an overview of the design of this modulator. There are several points of emphasis for the P2 Marx design. First, the modulator must be compatible with the ILC two-tunnel design. In this scheme, the modulator and klystron are located within a service tunnel with limited access and available footprint for a modulator. Access to the modulator is only practical from one side. Second, the modulator must have high availability. Robust components are not sufficient alone to achieve availability much higher than 99%. Therefore, redundant architectures are necessary. Third, the modulator must be relatively low cost. Because of the large number of stations in the ILC, the investment needed for the modulator components is significant. High-volume construction techniques which take advantage of an economy of scale must be utilized. Fourth, the modulator must be simple and efficient to maintain. If a modulator does become inoperable, the MTTR must be small. Fifth, even though the present application for the modulator is for the ILC, future accelerators can also take advantage of this development effort. The hardware, software, and concepts developed in this project should be designed such that further development time necessary for other applications is minimal.

43 PARTICLE ACCELERATORS↗

X-Band Multi-Beam Klystron Design and Progress Report

Progress on the development of a 5MW 16 beam x-band multi-beam klystron is presented. The power from each of the 16 klystrons is combined using a matched waveguide network. Mechanical and electric models and simulations are discussed. The status of procuring and assembling parts is presented.

43 PARTICLE ACCELERATORS↗

Development of high power CW 3.7 GHz klystrons for fusion experiments on Tore Supra

In the frame of the CIMES project, a collaborative effort between Association Euratom-CEA and Thales Electron Devices (TED) has led to the development of a high power CW klystron TH 2103 C, working at 3.7 GHz, for plasma heating and current drive for the Tokamak Tore Supra. A prototype has been manufactured and thoroughly tested on water load in December 2007 to verify that all the parameters met the specifications. The paper will present in detail the process and results of the test of the klystrons.

43 PARTICLE ACCELERATORS↗

Low Beam Voltage, 10 MW, L-Band Cluster Klystron

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

43 PARTICLE ACCELERATORS↗

Sheet Beam Klystron Instability Analysis

Using the principle of energy balance we develop a 2D theory for calculating growth rates of instability in a two-cavity model of a sheet beam klystron. An important ingredient is a TE-like mode in the gap that also gives a longitudinal kick to the beam. When compared with a self-consistent particle-in-cell calculation, with sheet beam klystron-type parameters, agreement is quite good up to half the design current, 65 A; at full current, however, other, current-dependent effects come in and the results deviate significantly.

43 PARTICLE ACCELERATORS↗

X-BAND KLYSTRON DEVELOPMENT AT SLAC

The development of X-band klystrons at SLAC originated with the idea of building an X-band Linear Collider in the late 1980's. Since then much effort has been expended in developing a reliable X-band Power source capable of delivering >50 MW RF power in pulse widths >1.5 {micro}s. I will report on some of the technical issues and design strategies which have led to the current SLAC klystron designs.

43 PARTICLE ACCELERATORS↗

XL4 Klystron (Top level drawing AD-700-924-00)

This drawing package is for the SLAC XL4 x-band pulsed klystron that was originally developed as a source for high gradient accelerator structures for the Next Linear Collider project. This device has proven to be a very useful source for driving a variety of high gradient breakdown experiments to linearizer and deflector structures instrumental to the LCLS operation. This klystron operates at a frequency of 11.424 GHz and produces a peak output power of 50 MW with a pulse length of 1.5 {mu}s at 60 Hz pulse repetition rate.

Tremaine, Aaron↗

5045 Klystron (Top level drawing AD-700-870-00)

This drawing package is for the SLAC 5045 s-band pulsed klystron that was designed to power the SLAC Linear Collider. It is currently powering the SLAC LCLS and FACET linear accelerators. This klystron operates at a frequency of 2.856 GHz and produces a peak output power of 67 MW with a pulse length of 3.5 {mu}s at 180 Hz pulse repetition rate.

Tremaine, Aaron↗

Apparatus makes klystron operating frequency adjustable from remote point

Apparatus makes possible proper frequency adjustment in a receiver using a pump klystron for a traveling-wave master. It incorporates a tunable overcoupled cavity with irises of appropriate size to accomplish frequency spread over the desired range and to maintain the Q of the klystron circuit at the optimum value.

Clauss, R. C.↗

Measurement of klystron phase modulation due to ac-powered filaments

A technique for determining the intermodulation components in the RF spectrum of the S-band radar transmitter generated by having the klystron filaments heated by 400-Hz ac power is described. When the klystron is being operated with 400-Hz (ac) on the filament, the IPM is buried in the 400-Hz equipment interference noise. The modulation sidebands were separated and identified and found to be-67 db below the main carrier. This is well below the transmitter specifications, and operating the filaments on ac would not degrade the spectrum to where it would be detrimental to the radiated RF.

Finnegan, E. J.↗

Solar power satellite 50 kW VKS-7773 cw klystron evaluation

A test program for evaluating the electrical characteristics of a cw, 50 kW power output klystron at 2.45 GHz is described. The tube tested was an 8-cavity klystron, the VKS-7773 which had been in storage for seven years. Tests included preliminary testing of the tube, cold tests of microwave components, tests of the electromagnet, and first and second hot tests of the tube. During the second hot test, the tuner in the fifth cavity went down to air, preventing any further testing. Cause of failure is not known, and recommendations are to repair and modify the tube, then proceed with testing as before to meet program objectives.

Larue, A. D.↗

The 5K70SK automatically tuned, high power, S-band klystron

Primary objectives include delivery of 44 5K70SK klystron amplifier tubes and 26 remote tuner assemblies with spare parts kits. Results of a reliability demonstration on a klystron test cavity are discussed, along with reliability tests performed on a remote tuning unit. Production problems and one design modification are reported and discussed. Results of PAT and DVT are included.

Goldfinger, A.↗

Analytical investigation of efficiency and performance limits in klystron amplifiers using multidimensional computer programs; multi-stage depressed collectors; and thermionic cathode life studies

An extensive parametric investigation was performed of the extraction of energy in output gaps of klystron amplifiers, using 3-D computer programs. Due to complexity of the program which used a hydrodynamic, axially and radially deformable disk ring model and the resulting long computing time, the investigation was limited to the output gap, by far the most important and difficult part of the klystron interaction. Results show that, for a confined flow focused beam throughout the penultimate cavity, radial velocities remain very small and the beam is highly laminar. It was, therefore, concluded that possible errors resulting from treating only the output cavity in 3-D would remain small.

Kosmahl, H. G.↗

High efficiency SPS klystron design

The most likely compact configuration to realize both high efficiency and high gain is a 5-6 cavity design focused by an electromagnet. An outline of a potential klystron configuration is given. The selected power output of 70 kW CW resulted from a maximum assumed operating voltage of 40 kV. The basic klystron efficiency cannot be expected to exceed 70-75% without collector depression. Although impressive gains were achieved in raising the basic efficiency from 50% to 70% or so with a multi-stage collector, the estimated efficiency improvement due to 5-stage collector at the 75% level is only about 8% resulting in an overall efficiency of about 83%.

Nalos, E. J.↗

Multi-stage Depressed Collectors (MDC) for efficiency improvements of UHF broadcast klystrons

The consumed primary power is reduced and the efficiency of traveling wave tubes is raised through the use of depressed collectors which passively convert potential energy into electric energy. Efficiency was kept with constant within a 3 dB range while the output power varied by 10 dB. Aspects to be considered in transferring this technology to UHF klystrons are the electron energy spectrum of the klystron and the magnitude of the injection angle required.