Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kWh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Grinding energy and physical properties of chopped and hammer-milled barley, wheat, oat, and canola straws

In the present study, specific energy for grinding and physical properties of wheat, canola, oat and barley straw grinds were investigated. The initial moisture content of the straw was about 0.13–0.15 (fraction total mass basis). Particle size reduction experiments were conducted in two stages: (1) a chopper without a screen, and (2) a hammer mill using three screen sizes (19.05, 25.4, and 31.75 mm). The lowest grinding energy (1.96 and 2.91 kWh t-1) was recorded for canola straw using a chopper and hammer mill with 19.05-mm screen size, whereas the highest (3.15 and 8.05 kWh t-1) was recorded for barley and oat straws. The physical properties (geometric mean particle diameter, bulk, tapped and particle density, and porosity) of the chopped and hammer-milled wheat, barley, canola, and oat straw grinds measured were in the range of 0.98–4.22 mm, 36–80 kg m-3, 49–119 kg m-3, 600–1220 kg m-3, and 0.9–0.96, respectively. The average mean particle diameter was highest for the chopped wheat straw (4.22-mm) and lowest for the canola grind (0.98-mm). The canola grinds produced using the hammer mill (19.05-mm screen size) had the highest bulk and tapped density of about 80 and 119 kg m-3; whereas, the wheat and oat grinds had the lowest of about 58 and 88–90 kg m-3. The results indicate that the bulk and tapped densities are inversely proportional to the particle size of the grinds. The flow properties of the grinds calculated are better for chopped straws compared to hammer milled using smaller screen size (19.05 mm).

09 BIOMASS FUELS↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water desalination through the dewpoint evaporative system

This paper presents the first numerical analysis of a novel Dew Point Desalination unit (DPD), which utilizes the phenomenon of the evaporative cooling process to minimize energy consumption. The proposed solution is based on a modular structure, which allows it to obtain any required water production capacity. The analyses for various operational parameters and various climatic conditions are based on the numerical simulations conducted using a validated mathematical model. The system performance was described with different factors, including specific energy consumption (SEC) and daily water production rate respected to 1 m^3*s^-1 of passing air stream (DWP). It is shown that the DPD system can operate in almost every climate zone, and the desalinated water production consumes less than 1.5 kWh*m^-3 of electric energy It is noted the best performance of the DPD system is achieved in the semi-arid, desert and subtropical climate zones. In these climate zones, the 2-stage DPD system allows the production of desalinated water with an electric energy consumption SEC lower than 0.5 kWh*m^-3. The additional benefit of the DPD system is its modularity. The presented DPD system stands as a module, that can be multiplied as needed to achieve the desired size of the desalination plant.

Desalination↗

Investigation of a thermocapacitive cycle by aqueous supercapacitors for multifunctional heat pump and energy storage

Thermocapacitive cycles are promising thermal and energy storage cycles using supercapacitors, which can achieve thermal efficiencies over 50% of the Carnot limit. There is a lack of work investigating the use of thermocapacitive effects in practical heat pumps. Here, this paper explores the design of thermocapacitive cells with higher temperature changes to be better suited for heat pumping applications. To evaluate the cell designs on temperature changes, pouch type cells are prototyped and modeled, and tested using a micro-calorimeter. A peak adiabatic temperature span of a LiCl aqueous cell is 2.7 °C. By arranging the cells in a cascade manner, the projected adiabatic temperature span can reach up to 12 °C with a heating density of 15 kW m −3 and an energy storage density of 0.83 kWh m −3 . Models predict that this could be increased to 30 °C and 1.65 kWh m −3 through improvements to cell capacitance and thermopower. Incorporating the energy storage capabilities into heating and cooling devices can be beneficial to building thermal management as energy storage becomes increasingly important for energy system integration.

25 ENERGY STORAGE↗

Near isothermal compressed air energy storage system in residential and commercial buildings: Techno-economic analysis

Electrical energy storage systems offer a wide range of options to efficiently manage our power supply infrastructure. Energy and environmental security via renewable resources and energy storage devices will also play a critical role in addressing the supply-demand challenges. A novel energy efficient storage system based on near isothermal compressed air energy storage concept, named as Ground-Level Integrated Diverse Energy Storage (GLIDES) is analyzed for integration with residential and commercial buildings. Additionally, the influence of different configurational aspects on key performance and cost attributes is presented in this study. GLIDES modules in the range of 0.5 kWh–15 kWh configurations were considered for residential buildings whereas 25 kW h–500 kW h modules were considered for commercial buildings. Detailed cost and performance analysis of the GLIDES module proved them to be an effective resource in lowering the peak energy demand and corresponding utility bills.

25 ENERGY STORAGE↗

Experimental screening of salt hydrates for thermochemical energy storage for building heating application

The selection of a suitable salt hydrate for use in a thermochemical energy storage system is challenging. In this work, the most promising salts to store intermediate heat energy were selected and tested. The criteria set are; volumetric energy density of >500 kWh m-3 with a dehydration temperature of <100 degrees C, material cost of <3.5 USD kg-1 (<15 USD kWh-1), melting does not occur during dehydration and safety. Based on that, the salt hydrates SrCl 2 , MgSO 4 , Na 3 PO 4 , MgCl 2 and SrBr 2 were selected and tested experimentally. A constant temperature and humidity chamber was used to measure moisture sorption of different salts. The hydration is investigated under the conditions of 20 degrees C and 20, 30, 40, 60 and 80% RH, while dehydration is investigated under the conditions of 70, 100 and 140 degrees C using an oven. These dehydration temperatures of <100 degrees C are suitable for solar application whereas the dehydration temperature of 140 degrees C is suitable for waste heat. Furthermore, the salts are cycled over 30 times under the hydration conditions of 20 degrees C, 60% RH with a dehydration temperature of 100 degrees C. From these results, it is concluded that SrCl 2 and SrBr 2 are the most promising salts. This study outlines both the advantages and disadvantages of each salt and states the conditions they are most suitable for.

25 ENERGY STORAGE↗

Measuring the maximum capacity and thermal resistances in phase-change thermal storage devices

Thermal energy storage can increase the efficiency of the electric grid by adding flexibility to thermal systems. The value of thermal storage is a function of its energy and power density, which are driven by the capacity and thermal resistances in the storage device. Measuring these properties in-situ at the device level is an important step to understanding the performance and improving the design of thermal storage systems. Here, we present methods to measure the total capacity and thermal resistances in heat exchangers with integrated phase change materials. These methods are demonstrated on two thermal storage devices - a 570-kWh ice-based storage tank and a 0.35-kWh graphite-tetradecane composite device. The results show how thermal resistances evolve with the state of charge and discharge rate in these devices and quantify the impact of applied pressure on the contact resistance in composite phase change material heat exchangers. The proposed method allows for easy comparison between different systems and provides information on the thermal bottlenecks limiting performance. Ultimately, these measurements will allow designers to make robust, high-performance thermal storage devices for next-generation thermal systems.

25 ENERGY STORAGE↗

Continuous caustic aqueous phase electrochemical reforming (CAPER) of ethanol for producing compressed hydrogen

Caustic Aqueous Phase Electrochemical Reforming (CAPER) of ethanol produces pure compressed H 2 at lower voltages, temperatures, and energy requirements than conventional electrolysis, while capturing carbonaceous products. The CAPER flow reactor consists of stainless steel endplates, stainless steel current collectors, and a Teflon flow field. The electrodes are prepared using commercial palladium nanoparticles on carbon support for the anode and platinum nanoparticles on carbon support for the cathode. The catalyst metal loading was 1 mgcm –2 on a 10cm 2 carbon cloth for both electrodes. Our CAPER reactor produces pure H 2 at 80bar and 80°C applying voltages at ≤0.5V. The only gas-phase product detected was H 2 and any carbonaceous products were contained in the liquid phase. The H 2 was produced with 97±4% faradaic efficiency. Further, operating at smaller electrode separation distances (4mm) and 80°C increased the current density. The highest lower heating value efficiency achieved was 28% at a flow rate of 0.05mLmin –1 and an applied voltage of 0.5V. The compressed H 2 was produced at ≤20 kWh kg –1 , which is much lower than electrolysis systems that require upwards of 50 kWh kg –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating manufacturing electricity costs by simulating dependence between production parameters

The electricity costs associated with manufacturing generally consist of an energy charge and a demand charge, which are calculated by total kWh × kWh and peak kW × kW, respectively. While these two charges have been extensively studied with production scheduling, dependence between production parameters has not been thoroughly investigated for production energy costs when the production parameters are assumed to be independent. Such dependence, however, can significantly affect the peak kW and resulting energy costs. Therefore, industrial practitioners need a tool to simulate the production power demand and cost to evaluate energy costs for each production plan and for any dependence in the parameters. In this paper, we propose a method for simulating the power demand at the machine and facility levels, focusing on the dependence in milling machine parameters. Using probabilistic techniques with copulas, we quantify the degree of dependence between two milling parameters (processing times and processing amounts) and build a power demand simulator combining discrete event simulation and numerical simulation models. From 35 illustrative examples, we show that a production strategy to adjust dependence can reduce the peak kW and energy costs by more than 15% and 4%, respectively. In addition to dependence, less variability in processing times results in less peak kW and energy costs. Other factors such as a marginal probability distribution and copula types having the same degree of variability have been found to have limited effects on reducing energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overbuilding & curtailment: The cost-effective enablers of firm PV generation

Current thinking considers that PV output curtailment is a last resort measure to be avoided. In this article, we argue that supply-shaping, achieved through proactive curtailment associated with PV oversupply, is actually critical to achieving intermittency mitigation and delivering firm PV generation at the lowest cost. We investigate the premium to transform a low-cost, but intermittent solar kWh into a firm, effectively dispatchable kWh. We show that a fundamental ingredient of minimizing this premium is to optimally overbuild and, as necessary and appropriate, curtail PV generation. Drawing on a case study in the State of Minnesota, we show that firm, high-penetration-ready PV generation could be achieved at a production cost at or below current conventional generation, especially when optimally coupled with wind generation. Here, we conclude with a recommendation that in order to achieve this lowest cost firm generation potential, proactive curtailment strategies should inform future transactional PV remuneration systems.

14 SOLAR ENERGY↗

Data-driven method for electric vehicle charging demand analysis: Case study in Virginia

Electric vehicle (EV) adoption in the U.S. will be accelerated by the historic $7.5 billion public investments in EV charging infrastructure. Careful analysis of EV charging demands plays a vital role in understanding the energy requirements, power grid impact, and smart charging management opportunities of EVs. To this end, this paper develops a data-driven trip-chaining-based modeling framework including five steps: Trip data acquisition and preprocessing, EV adoption modeling, travel itinerary synthesis, EV charging demand simulation and EV load profile generation. The developed analysis framework was demonstrated using real-world data for one region in Virginia, U.S. The results show that the proposed modeling framework can work effectively. For the study region in 2040, the predicted number of plug-in EVs is 470,114, resulting in a weekly charging demand of 38,078,127 kWh (55% home, 9% work, and 36% public) in September and 45,920,358 kWh (61% home, 9% work, and 30% public) in February.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modelling of air handling unit subsystem in a commercial building

To improve energy efficiency of the Air Handling Unit (AHU), there is a need for a system to monitor energy performance of the AHU in real time, to optimize operation for minimum energy consumption and to calculate energy saving. A mechanical model was created to analyze the performance of subsystems in an AHU and was validated using actual data collected from AHU operation via a wireless monitoring system. Algorithms have been developed to identify malfunctions and estimate the savings if malfunctions are corrected. Here, the model detects control related malfunctions, such as simultaneously turning on the cooling coil and the pre-heating coil. According to the mechanical model of the case study system, a total of 63,455 kWh are wasted within the cooling coil and the pre-heating coil due to this type of control malfunction. Furthermore, the mechanical model can identify other energy savings opportunities due to set point changes; in the case study system, this feature revealed a total of 77,141 kWh energy saving during the same study period. The design, integration, and validation of the mechanical model are described, analyzed, and justified in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simple tool for estimating city-wide annual electrical energy savings from cooler surfaces

We present a simple method to estimate the maximum possible electrical energy saving that might be achieved by increasing the albedo of surfaces in a large city. We restrict this to the “indirect effect”, the cooling of outside air that lessens the demand for air conditioning (AC). Given the power demand of the electric utilities and data about the city, we can use a single linear equation to estimate the maximum savings. For example, the result for an albedo change of 0.2 of pavements in a typical warm city in California, such as Sacramento, is that the saving is less than about 2 kWh per m2 per year. This may help decision makers choose which heat island mitigation techniques are economical from an energy-saving perspective.

Pomerantz, Melvin↗

Performance evaluation of an anaerobic/aerobic landfill-based digester using yard waste for energy and compost production

Highlights: Black-Right-Pointing-Pointer Biochemical methane potential decreased by 83% during the two-stage operation. Black-Right-Pointing-Pointer Net energy produced was 84.3 MWh or 46 kWh per million metric tons (Mg). Black-Right-Pointing-Pointer The average removal efficiency of volatile organic compounds (VOCs) was 96-99%. Black-Right-Pointing-Pointer The average removal efficiency of non-methane organic compounds (NMOCs) was 68-99%. Black-Right-Pointing-Pointer The two-stage batch digester proved to be simple to operate and cost-effective. - Abstract: The objective of this study was to evaluate a new alternative for yard waste management by constructing, operating and monitoring a landfill-based two-stage batch digester (anaerobic/aerobic) with the recovery of energy and compost. The system was initially operated under anaerobic conditions for 366 days, after which the yard waste was aerated for an additional 191 days. Off gas generated from the aerobic stage was treated by biofilters. Net energy recovery was 84.3 MWh, or 46 kWh per million metric tons of wet waste (as received), and the biochemical methane potential of the treated waste decreased by 83% during the two-stage operation. The average removal efficiencies of volatile organic compounds and non-methane organic compounds in the biofilters were 96-99% and 68-99%, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combining anaerobic digestion and hydrothermal liquefaction in the conversion of dairy waste into energy: A techno economic model for New York state

There is increasing global interest and policies being enacted to lower greenhouse gas emissions, especially from the agricultural sector. In the U.S. for example, states with large dairy operations may combine proven manure valorization technologies, such as anaerobic digestion and hydrothermal liquefaction. Sustainable manure treatment would increase the recovery of energy and other useful co-products, namely biogas, biocrude oil and hydro-char as well as lower the environmental impacts. In this study, the economic feasibility of implementing a centralized bioenergy system in New York State was investigated. Here, the feasibility of this transformation depends on many factors, including capital costs, discount rates, and other financing arrangements, electricity selling prices, incentives and farm sizes and locations. For a large-scale implementation in New York State accounting for nearly 50% of the state’s dairy farms, our model of a distributed, hybrid anaerobic/hydrothermal system was shown to treat 590 million liters of wet manure per day, producing 607 million kWh of electricity, 162,000 L of biocrude oil and 117,000 kg of hydro-char per day. Electricity selling price is a critical factor. Increasing the electricity selling price from wholesale ($\$0.06$ /kWh) to retail ($\$0.18$ kWh) increased the net present value from $\$395$ million to $1.5 billion (considering a 40-year project lifetime).

42 ENGINEERING↗

Energy Evaluation of Electron Beam Treatment of Perfluoroalkyl Substances in Water: A Critical Review

Due to their recalcitrant nature and ubiquitous use, per- and polyfluoroalkyl substances (PFAS) will continue to be major water treatment hurdles. Although effective water treatment technologies exist for physical removal of many PFAS from water (e.g., activated carbon and ion-exchange resin), a PFAS-concentrated waste stream is generated as an end product that can potentially reintroduce PFAS back into the environment. Thus, there is an increased interest in developing destructive technologies to decompose and mineralize PFAS directly in water or in these waste streams. High energy electron beam (e-beam) accelerators have been used for water treatment to degrade a wide range of recalcitrant contaminants, including PFAS, since the 1960s. However, large-scale applications of e-beam for water treatment are restricted due to its high energy consumption and inability to treat large flow rates. Considering there are very few available technologies for destructive removal of PFAS, this study provides a critical review on the treatment of PFAS by direct irradiation of contaminated water by e-beam from an energy consumption point of view. To date, very limited studies have been conducted to investigate the success of this technology to treat PFAS. Results from the limited studies were not directly comparable due to the variation in operating conditions and water quality parameters used in the studies. Here, for the first time, we develop and apply the concept of electrical energy per order (EE/O) to assess the performance of e-beam for PFAS treatment. Results show that EE/O is a better performance parameter than the G value of e-beam for interstudy comparisons and to evaluate the effects of water quality and operating parameters on e-beam performance. We additionally developed a kinetic scheme to predict the performance of e-beam to treat PFAS and revealed that the competition between species to react with aqueous electrons is the determinant factor influencing PFAS degradation efficiency. Comparison of EE/O values of e-beam (range: 31–176 kWh m –3 order –1 ) with other destructive technologies (range: 5–9595 kWh m –3 order –1 ) suggest that e-beam, for PFAS treatment, is a promising approach under favorable conditions. Furthermore, this review further elucidates the feasibility and limitations of e-beam technology that could be improved upon to potentially make e-beam viable for large-scale water treatment applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗