Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “jitter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Gravity gradient or gravity jitter induced viscous stress and moment fluctuations in microgravity

The dynamical behavior of fluids affected by the asymmetric gravity gradient and gravity jitter accelerations, in particular the effect of surface tension on partially-filled rotating fluids with a special example applicable to a full-scale Gravity Probe-B Spacecraft dewar tank, has been investigated. Results of slosh wave excitation along the liquid-vapor interface induced by gravity gradient acceleration indicated one-up one-down and one-down and one-up oscillations of two bubbles in the cross-section of doughnut profiles in the vertical r-z plane of a rotating dewar, and an eccentric contour of a bubble rotating around the axis of the dewar in the horizontal r-theta plane. Results of slosh wave excitation along the liquid-vapor interface induced by gravity jitter acceleration showed an equivalent to the time-dependent oscillatory force which pushes a bubble in the combined bubble motion of down-and-up and leftward-and-rightward as the bubble is rotating with respect to a rotating dewar axis. Fluctuations of fluid stress forces, fluid stress moments, and moment arm of fluid moment exerted on the dewar wall of the container due to slosh wave excitations driven by gravity gradient acceleration or gravity jitter acceleration are also investigated.

Hung, R. J.↗

Simulation of sloshing dynamics induced forces and torques actuated on dewar container driven by gravity gradient and jitter accelerations in microgravity

Some experimental spacecraft use superconducting sensors for gyro read-out and so must be maintained at a very low temperature. The boil-off from the cryogenic liquid used to cool the sensors can also be used, as the Gravity Probe B (GP-B) spacecraft does, as propellant to maintain attitude control and drag-free operation of the spacecraft. The cryogenic liquid for such spacecraft is, however, susceptible to both slosh-like motion and non-axisymmetric configurations under the influence of various kinds of gravity jitter and gravity gradient accelerations. Hence, it is important to quantify the magnitude of the liquid-induced perturbations on the spacecraft. We use the example of the GP-B to investigate such perturbations by numerical simulations. For this spacecraft disturbances can be imposed on the liquid by atmospheric drag, spacecraft attitude control maneuvers, and the earth's gravity gradient. More generally, onboard machinery vibrations and crew motion can also create disturbances. Recent studies suggest that high frequency disturbances are relatively unimportant in causing liquid motions in comparison to low frequency ones. The results presented here confirm this conclusion. After an initial calibration period, the GP-B spacecraft rotates in orbit at 0.1 rpm about the tank symmetry axis. For this rotation rate, the equilibrium liquid free surface shape is a 'doughnut' configuration for all residual gravity levels of 10(exp -6) g(sub 0) or less, as shown by experiments and by numerical simulations; furthermore, the superfluid behavior of the 1.8 K liquid helium used in GP-B eliminates temperature gradients and therefore such effects as Marangoni convection do not have to be considered. Classical fluid dynamics theory is used as the basis of the numerical simulations here, since Mason's experiments show that the theory is applicable for cryogenic liquid helium in large containers. To study liquid responses to various disturbances, we investigate and simulate three levels of gravity jitter (10(exp -6), 10(exp -7), and 10(exp -8) g(sub 0)) each at three predominant frequencies (0.1, 1.0, and 10 Hz), combined with a gravity gradient appropriate for the GP-B orbit. Dynamical evolution of sloshing dynamics excited fluid forces and torque fluctuations exerted on the dewar container driven by the combined gravity gradient and jitter accelerations are also investigated and simulated.

Hung, R. J.↗

Peculiar Behavior of He II Disturbances due to Sloshing Dynamics Driven by Jitter Accelerations Associated with Slew Motion in Microgravity

The mathematical formulation of Dewar container sloshing dynamics when partially filled with superfluid liquid He 11 driven by the gravity jitter acceleration associated with slew motion in a microgravity environment is studied. Numerical computation of the sloshing dynamics is based on the non-inertia container bound co-ordinate, and solving time-dependent, three-dimensional formulations of partial differential equations subject to initial and boundary conditions. This study discloses the capillary effect of the sloshing dynamics governing the liquid-vapour interface fluctuations driven by the gravity jitter acceleration associated with slew motion, which affects the stability of the fluid system in a microgravity environment. The peculiar behaviour of superfluid helium when reacting to the sloshing dynamics driven by the gravity jitter acceleration associated with slew motion in a microgravity environment is also investigated.

Hung, R. J.↗

Fluid System Angular Momentum and Moment Fluctuations Driven by Gravity Gradient or Gravity Jitter in Microgravity

The dynamical behaviour of fluids affected by the asymmetric gravity gradient acceleration and gravity jitter acceleration, in particular the effect of surface tension on partially-filled rotating fluids with special example applicable to a full-scale Gravity Probe-B Spacecraft dewar tank have been investigated. Results of slosh wave excitation along liquid-vapor interface induced by gravity gradient acceleration indicated that one-up one-down and one-down one-up oscillations of two bubbles in the cross-section of doughnut profiles in the vertical r-z plane of rotating dewar, and an eccentric contour of bubble rotating around the axis of dewar in horizontal r-Theta plane. Results of slosh wave excitation along liquid-vapor interface induced by gravity jitter acceleration indicated equivalent to time-dependent oscillatory forces which push bubble in the combined bubble motion of down-and-up and leftward-and-rightward as the bubble is rotating with respect to rotating dewar axis. Fluctuations of angular momentum, fluid moment and bubble mass center caused by slosh wave excitations driven by gravity gradient acceleration or gravity jitter acceleration are also investigated.

Hung, R. J.↗

Magnetic Damping of g-Jitter Driven Flows: 3-D Calculations

A 3-D numerical model is developed to represent the oscillating natural convection induced in a cylindrical cavity filled with Ga-doped germanium with and without the presence of an external magnetic field. The model is developed based on the penalty-finite element solution of the equations describing the transport of momentum, heat and solutal element as well as the electromagnetic field distribution in the melt pool. Automatic time step control is applied to help speed up the calculations. Numerical simulations are conducted to study the convection and magnetic damping effects as a function of frequency, directions and amplitudes of g-jitter and also the direction and magnitudes of the applied magnetic fields. The results show that the g-jitter driven flow is time dependent and exhibits a complex recirculating convection pattern in three dimensions and that an applied magnetic field can be employed to suppress this deleterious convective flow and both magnitude and orientation of the applied field are important in magnetic damping of the g-jitter induced convective flows.

Shang, D. Y.↗

An Experimental Study of a Low-Jitter Pulsed Electromagnetic Plasma Accelerator

An experimental plasma accelerator for a variety of applications under development at the NASA Marshall Space Flight Center is described. The accelerator is a pulsed plasma thruster and has been tested experimentally and plasma jet velocities of approximately 50 kilometers per second have been obtained. The plasma jet structure has been photographed with 10 ns exposure times to reveal a stable and repeatable plasma structure. Data for velocity profile information has been obtained using light pipes embedded in the gun walls to record the plasma transit at various barrel locations. Preliminary spatially resolved spectral data and magnetic field probe data are also presented. A high speed triggering system has been developed and tested as a means of reducing the gun "jitter". This jitter has been characterized and future work for second generation "ultra-low jitter" gun development is identified.

Thio, Y. C. Francis↗

Integrated Modeling Activities for the James Webb Space Telescope: Optical Jitter Analysis

This is a continuation of a series of papers on the integrated modeling activities for the James Webb Space Telescope(JWST). Starting with the linear optical model discussed in part one, and using the optical sensitivities developed in part two, we now assess the optical image motion and wavefront errors from the structural dynamics. This is often referred to as "jitter: analysis. The optical model is combined with the structural model and the control models to create a linear structural/optical/control model. The largest jitter is due to spacecraft reaction wheel assembly disturbances which are harmonic in nature and will excite spacecraft and telescope structural. The structural/optic response causes image quality degradation due to image motion (centroid error) as well as dynamic wavefront error. Jitter analysis results are used to predict imaging performance, improve the structural design, and evaluate the operational impact of the disturbance sources.

Hyde, T. Tupper↗

Effects of g-Jitter on Diffusion in Binary Liquids

The microgravity environment offers the potential to measure the binary diffusion coefficients in liquids without the masking effects introduced by buoyancy-induced flows due to Earth s gravity. However, the background g-jitter (vibrations from the shuttle, onboard machinery, and crew) normally encountered in many shuttle experiments may alter the benefits of the microgravity environment and introduce vibrations that could offset its intrinsic advantages. An experiment during STS-85 (August 1997) used the Microgravity Vibration Isolation Mount (MIM) to isolate and introduce controlled vibrations to two miscible liquids inside a cavity to study the effects of g-jitter on liquid diffusion. Diffusion in a nonhomogeneous liquid system is caused by a nonequilibrium condition that results in the transport of mass (dispersion of the different kinds of liquid molecules) to approach equilibrium. The dynamic state of the system tends toward equilibrium such that the system becomes homogeneous. An everyday example is the mixing of cream and coffee (a nonhomogeneous system) via stirring. The cream diffuses into the coffee, thus forming a homogeneous system. At equilibrium the system is said to be mixed. However, during stirring, simple observations show complex flow field dynamics-stretching and folding of material interfaces, thinning of striation thickness, self-similar patterns, and so on. This example illustrates that, even though mixing occurs via mass diffusion, stirring to enhance transport plays a major role. Stirring can be induced either by mechanical means (spoon or plastic stirrer) or via buoyancy-induced forces caused by Earth s gravity. Accurate measurements of binary diffusion coefficients are often inhibited by buoyancy-induced flows. The microgravity environment minimizes the effect of buoyancy-induced flows and allows the true diffusion limit to be achieved. One goal of this experiment was to show that the microgravity environment suppresses buoyancy-induced convection, thereby mass diffusion becomes the dominant mechanism for transport. Since g-jitter transmitted by the shuttle to the experiment can potentially excite buoyancy-induced flows, we also studied the effects of controlled vibrations on the system.

Duval, Walter M. B.↗

Solar Dynamics Observatory (SDO) HGAS Induced Jitter

This paper presents the results of a comprehensive assessment of High Gain Antenna System induced jitter on the Solar Dynamics Observatory. The jitter prediction is created using a coupled model of the structural dynamics, optical response, control systems, and stepper motor actuator electromechanical dynamics. The paper gives an overview of the model components, presents the verification processes used to evaluate the models, describes validation and calibration tests and model-to-measurement comparison results, and presents the jitter analysis methodology and results.

Liu, Alice↗

GOES I-M: A Retrospective Look at Image Navigation and Registration (INR), Jitter and Lessons Learned

The Geostationary Operational Environmental Satellite (GOES) I-M series of spacecraft was the second generation of United States meteorological observational platforms in geosynchronous orbit. They served as the principal Earth- viewing observational platforms for continuously monitoring dynamic weather events from the mid-1990s and into the 21st century. This paper will look back at the program framing key system attributes of the mission, which necessitated a multi-layered development approach to meet stringent meteorological instrument Line-of-Sight (LoS) pointing and pointing stability requirements. The overall approach involved understanding, correcting, and avoiding pointing errors across a broad frequency range including what would typically be called dynamic interaction and jitter. Background information will be provided covering the mission architecture and program drivers. The systems solution for man- aging and mitigating the deleterious influences of on-board disturbances in order to meet the challenging instrument LoS pointing and jitter requirements will be described, along with the ‘first of its kind’ Image Navigation and Registration system. A broad look back at the lessons learned that emerged from the GOES I- M experience will be presented, with the intent of capturing general and specific insights for developers of future missions having stringent payload instrument pointing requirements. These discussions will touch on such critical aspects as defining jitter and related pointing requirements, the importance of early system architectural decisions, understanding and reducing on-board disturbances, the balance of test and analysis, and the imperative for maximizing on-orbit operational flexibility in order to accommodate unexpected dynamic interactions.

Sudey, John↗

Spacecraft Line-of-Sight Jitter Management and Mitigation Lessons Learned and Engineering Best Practices

Predicting, managing, controlling, and testing spacecraft line-of-sight (LoS) jitter caused by micro-vibrations due to on-board internal disturbance sources is a formidable multidisciplinary engineering task. It is especially challenging for those missions hosting high-performance (e.g., nano-radian/milli-arcsecond class), vibration-sensitive optical sensor payloads with stringent pointing stability requirements. The Nation Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are planning technically aggressive spaceflight missions that include ultra-high-performance optical payloads with delicate, highly vibration-sensitive scientific and observational instruments. The guidance, navigation, and control community of practice will need to leverage collective experiences and document their best practices and lessons learned to address future micro-vibration challenges. To identify lessons learned and best practices the NASA Engineering & Safety Center sponsored a 2-day Spacecraft LoS Jitter Workshop in late 2019. The workshop’s goal was to provide a multidisciplinary forum to elicit deeper understanding of the issues related to addressing the spacecraft LoS jitter/micro-vibration problem. The primary objective was to identify, document, and share lessons learned, best practices, and preferred options for jitter-related analysis and test activities. Representatives from NASA, ESA, along with NASA’s industrial partners, independent consultant subject matter experts, and members of academia participated in the workshop. This paper describes the motivation for the workshop and summarize the identified findings and recommendations.

Lessons Learned↗

Spacecraft Line-Of-Sight Jitter Management and Mitigation Lessons Learned And Engineering Best Practices

Predicting, managing, controlling, and testing spacecraft line-of-sight (LoS) jitter caused by micro-vibrations due to on-board internal disturbance sources is a formidable multidisciplinary engineering task. It is especially challenging for those missions hosting high-performance (e.g., nano-radian/milli-arcsecond class), vibration-sensitive optical sensor payloads with stringent pointing stability requirements. The Nation Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are planning technically aggressive spaceflight missions that include ultra-high-performance optical payloads with delicate, highly vibration-sensitive scientific and observational instruments. The guidance, navigation, and control community of practice will need to leverage collective experiences and document their best practices and lessons learned to address future micro-vibration challenges. To identify lessons learned and best practices the NASA Engineering & Safety Center sponsored a 2-day Spacecraft LoS Jitter Workshop in late 2019. The workshop’s goal was to provide a multidisciplinary forum to elicit deeper understanding of the issues related to addressing the spacecraft LoS jitter/micro-vibration problem. The primary objective was to identify, document, and share lessons learned, best practices, and preferred options for jitter-related analysis and test activities. Representatives from NASA, ESA, along with NASA’s industrial partners, independent consultant subject matter experts, and members of academia participated in the workshop. This paper will describe the motivation for the workshop and summarize the identified findings and recommendations.

Swanson, Davin K.↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

LANDSAT-D MSS/TM tuned orbital jitter analysis model LDS900

The final LANDSAT-D orbital dynamic math model (LSD900), comprised of all test validated substructures, was used to evaluate the jitter response of the MSS/TM experiments. A dynamic forced response analysis was performed at both the MSS and TM locations on all structural modes considered (thru 200 Hz). The analysis determined the roll angular response of the MSS/TM experiments to improve excitation generated by component operation. Cross axis and cross experiment responses were also calculated. The excitations were analytically represented by seven and nine term Fourier series approximations, for the MSS and TM experiment respectively, which enabled linear harmonic solution techniques to be applied to response calculations. Single worst case jitter was estimated by variations of the eigenvalue spectrum of model LSD 900. The probability of any worst case mode occurrence was investigated.

Pollak, T. E.↗

Jitter performance test for the Hubble Space Telescope - Method and results

The types of on-board equipment on the Hubble Space Telescope (HST) that can cause jitter are identified. Tests designed and conducted to measure the motion of the focal plane due to disturbances from the on-board equipment are then described. Test results are presented for two types of jitter-producing equipment: the reaction wheel assemblies and the engineering/science tape recorders.

Blair, Mark A.↗

Reorientation of rotating fluid in microgravity environment with and without gravity jitters

In a spacecraft design, the requirements of settled propellant are different for tank pressurization, engine restart, venting, or propellant transfer. The requirement to settle or to position liquid fuel over the outlet end of the spacecraft propellant tank prior main engine restart poses a microgravity fluid behavior problem. In this paper, the dynamical behavior of liquid propellant, fluid reorientation, and propellant resettling have been carried out through the execution of supercomputer CRAY X-MP to simulate the fluid management in a microgravity environment. Results show that the resettlement of fluid can be accomplished more efficiently for fluid in rotating tank than in nonrotating tank, and also better performance for gravity jitters imposed on fluid settlement than without gravity jitters based on the amount of time needed to carry out resettlement period of time between the initiation and termination of geysering.

Hung, R. J.↗

The measurement system of pulse modulated carrier frequency stability and timing jitter

The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.

Li Cheng-Fu↗

Longitudinal and transverse modes of slosh wave excitation in rotating dewar associated with gravity jitters

Characteristics of slosh waves based on the dynamical behavior of oscillations at the liquid-vapor interface have been investigated. Twelve case studies of slosh wave excitation due to various frequencies of gravity jitters under different rotating speeds of the propellant tank and different levels of background gravity environment have been simulated. The study shows that slosh waves excited inside the spacecraft propellant tank are characterized by the lowest frequency of the waves initiated, frequencies of the gravity jitters imposed on the propellant system, the levels of background gravity environment, and dewar rotating speeds. Conditions for suppression and amplification of the slosh waves are discussed.

Hung, R. J.↗