Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “jet images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fluorescence Imaging Study of Transition in Underexpanded Free Jets

Planar laser-induced fluorescence (PLIF) is demonstrated to be a valuable tool for studying the onset of transition to turbulence. For this study, we have used PLIF of nitric oxide (NO) to image underexpanded axisymmetric free jets issuing into a low-pressure chamber through a smooth converging nozzle with a sonic orifice. Flows were studied over a range of Reynolds numbers and nozzle-exit-to-ambient pressure ratios with the aim of empirically determining criteria governing the onset of turbulence. We have developed an image processing technique, involving calculation of the standard deviation of the intensity in PLIF images, in order to aid in the identification of turbulence. We have used the resulting images to identify laminar, transitional and turbulent flow regimes. Jet scaling parameters were used to define a rescaled Reynolds number that incorporates the influence of a varying pressure ratio. An empirical correlation was found between transition length and this rescaled Reynolds number for highly underexpanded jets.

Wilkes, Jennifer A.↗

Faint Object Camera observations of M87 - The jet and nucleus

UV and optical images of the central region and jet of the nearby elliptical galaxy M87 have been obtained with about 0.1 arcsec resolution in several spectral bands with the Faint Object Camera (FOC) on the HST, including polarization images. Deconvolution enhances the contrast of the complex structure and filamentary patterns in the jet already evident in the aberrated images. Morphologically there is close similarity between the FOC images of the extended jet and the best 2-cm radio maps obtained at similar resolution, and the magnetic field vectors from the UV and radio polarimetric data also correspond well. We observe structure in the inner jet within a few tenths arcsec of the nucleus which also has been well studied at radio wavelengths. Our UV and optical photometry of regions along the jet shows little variation in spectral index from the value 1.0 between markedly different regions and no trend to a steepening spectrum with distance along the jet.

Boksenberg, A.↗

CN jets of Comet P/Halley: Rotational properties

An analysis of CCD images of CN jets of comet P/Halley observed during April 16 to 29 1986 is discussed. The analysis questions the 53 hr rotation period and favors a rotational period of 7.37 days, as suggested by Millis and Schleicher (1986). It is shown that a change in rotation period, at least from one apparition to the next, is also possible. A lower limit for the ejection velocity of dust grains (which emit CN) in the jet is established to be 0.5 km/sec with an uncertainty of 50%. The constraints on the direction of the rotation axis as inferred from the geometry of the jets are considered.

Samarasinha, Nalin H.↗

Observations of barium ion jets in the magnetosphere using Doppler imaging systems and very sensitive imaging systems using imaging photon detectors

Observations of four shaped charge releases from rockets launched from Alaska are described. Results demonstrate that imaging and Doppler imaging instruments, based on exploiting the imaging photon detector, provide additional insight into the motion and development of low intensity targets such as the fast ion jets produced by shaped charge releases. It is possible to trace the motion of fast ion jets to very great distances, of the order of 50,000 km, outward along the Earth's magnetic field, when the conditions are suitable for the outward (upward) motion and/or acceleration of such ion jets. It is shown that ion jets, which fade below the lower sensitivity threshold of previous instruments, do not always disappear. There is no evidence of an abrupt field-aligned shear-type acceleration.

Rees, D.↗

Photo-reconnaissance applications of computer processing of images.

Discussion of imaging processing techniques for enhancement and calibration of Jet Propulsion Laboratory imaging experiment pictures returned from NASA space vehicles such as Ranger, Mariner and Surveyor. Particular attention is given to data transmission, resolution vs recognition, and color aspects of digital data processing. The effectiveness of these techniques in applications to images from a wide variety of sources is noted. It is anticipated that the use of computer processing for enhancement of imagery will increase with the improvement and cost reduction of these techniques in the future.

Billingsley, F. C.↗

Holographic particle image velocimetry measurements in a rectangular jet

The development and testing of a holographic technique capable of measuring the three velocity components in selected regions of the flow field are described. Several techniques, including laser Doppler velocimetry, hot wire and particle image velocimetry (PIV) are commonly used to measure a flow field. The advantage of the PIV technique is that it provides instantaneous measurements in a selected plane of the flow field. The aim is to extend the conventional two dimensional PIV technique to simultaneously record several planes by means of the holographic technique. In the holographic technique, parallel laser sheets are used to increase the intensity of the light in specific planes of the flow field. Particles as small as 5 microns can be recorded.

VanEck, A.↗

Analysis of Particle Image Velocimetry (PIV) Data for Application to Subsonic Jet Noise Studies

Global velocimetry measurements were taken using Particle Image Velocimetry (PIV) in the subsonic flow exiting a 1 inch circular nozzle in an attempt to better understand the turbulence characteristics of its shear layer region. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Custom data analysis and data validation algorithms were developed and applied to a data ensemble consisting of over 750 PIV 70 mm photographs taken in the 0.85 mach flow facility. Results are presented detailing spatial characteristics of the flow including ensemble mean and standard deviation, turbulence intensities and Reynold's stress levels, and 2-point spatial correlations.

Blackshire, James L.↗

Maximum entropy deconvolution of the optical jet of 3C 273

The technique of maximum entropy image restoration is applied to the problem of deconvolving the point spread function from a deep, high-quality V band image of the optical jet of 3C 273. The resulting maximum entropy image has an approximate spatial resolution of 0.6 arcsec and has been used to study the morphology of the optical jet. Four regularly-spaced optical knots are clearly evident in the data, together with an optical 'extension' at each end of the optical jet. The jet oscillates around its center of gravity, and the spatial scale of the oscillations is very similar to the spacing between the optical knots. The jet is marginally resolved in the transverse direction and has an asymmetric profile perpendicular to the jet axis. The distribution of V band flux along the length of the jet, and accurate astrometry of the optical knot positions are presented.

Evans, I. N.↗

Application of PIV to the Measurement of High Speed Jet Flows

The Particle Image Velocimetry, PIV, has been implemented for the investigation of high-speed jet flows at the NASA Langley Research Center. In this approach the velocity (displacement) is found as the location of a peak in the correlation map of particle images acquired in quick succession. In the study, the technique for the correct seeding of the flow field were developed and implemented and the operational parameters influencing the accuracy of the measurement have been optimized.

Lourenco, L.↗

High-speed volumetric imaging of formaldehyde in a lifted turbulent jet flame using an acousto-optic deflector

The development of high-speed volumetric laser-induced fluorescence measurements of formaldehyde (CH 2 O-LIF) using a pulse-burst laser operated at a repetition rate of 100 kHz is presented here. A novel laser scanning system employing an acousto-optic deflector (AOD) enables quasi-4D CH 2 O-LIF imaging at a scan frequency of 10 kHz. The diagnostic capability of time-resolved volumetric imaging is demonstrated in a partially premixed DME/air lifted turbulent jet flame near the flame base. Simultaneous imaging of laser beam profiles is performed to account for the laser pulse energy fluctuation and laser sheet inhomogeneity. With the accurate registration of laser sheet positions, the volumetric reconstruction of CH 2 O-LIF signals is performed within a detection volume of 17.3 × 11.9 × 2.3 mm 3 with an average out-of-plane spatial resolution of 250μm. A surface detection algorithm with adaptive thresholding is used to determine the global maximum intensity gradient by calculating gradient percentiles. The flame topology characteristics are investigated by evaluating the 3D curvatures of CH 2 O surfaces. Curvatures calculated using 2D data systematically underestimate the full 3D curvature due to the lack of out-of-plane information. The inner surfaces near the turbulent fuel jet exhibit higher probabilities of large mean curvature than the outer surfaces. The saddle and cylindrical structures are dominant on both the inner and outer surfaces and the elliptic structures occur with lower probability. The results suggest that the damping of turbulent fluctuations by the temperature increase through the CH 2 O region reduces the curvature, but the local structure topology remains self-similar.

42 ENGINEERING↗

Time-Resolved PIV for Space-Time Correlations in Hot Jets

Temporally Resolved Particle Image Velocimetry (TR-PIV) is being used to characterize the decay of turbulence in jet flows a critical element for understanding the acoustic properties of the flow. A TR-PIV system, developed in-house at the NASA Glenn Research Center, is capable of acquiring planar PIV image frame pairs at up to 10 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Wernet, Mark P.↗

The High Resolution Chandra X-Ray Spectrum of 3C273

The bright quasar 3C273 was observed by Chandra in January 2000 for 120 ksec as a calibration target. It was observed with all detector- plus-grating combinations (ACIS+HETG, ACIS+LETG, and HRC+LETG) yielding an X-ray spectrum across the entire 0.1-10 keV band with unprecedented spectral resolution. At about 10 arcsec from the nucleus, an X-ray jet is also clearly visible and resolved in the Oth order images. While the jet is much fainter than the nuclear source, the Chandra spatial resolution allows, for the first time, spectral analysis of both components separately. We will present detailed spectral analysis with particular emphasis on possible absorption features and comparison with simultaneous BeppoSAX data.

Fruscione, Antonella↗

HyTES: Thermal Imaging Spectrometer Development

The Jet Propulsion Laboratory has developed the Hyperspectral Thermal Emission Spectrometer (HyTES). It is an airborne pushbroom imaging spectrometer based on the Dyson optical configuration. First low altitude test flights are scheduled for later this year. HyTES uses a compact 7.5-12 micrometer m hyperspectral grating spectrometer in combination with a Quantum Well Infrared Photodetector (QWIP) and grating based spectrometer. The Dyson design allows for a very compact and optically fast system (F/1.6). Cooling requirements are minimized due to the single monolithic prism-like grating design. The configuration has the potential to be the optimal science-grade imaging spectroscopy solution for high altitude, lighter-than-air (HAA, LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The QWIP sensor allows for optimum spatial and spectral uniformity and provides adequate responsivity which allows for near 100mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. The QWIP's repeatability and uniformity will be helpful for data integrity since currently an onboard calibrator is not planned. A calibration will be done before and after eight hour flights to gage any inconsistencies. This has been demonstrated with lab testing. Further test results show adequate NEDT, linearity as well as applicable earth science emissivity target results (Silicates, water) measured in direct sunlight.

remote sensing↗

Particle image displacement velocimetry measurements of a three-dimensional jet

A whole field experimental technique, commonly referred to as particle image displacement velocimetry (PIDV), is used for the measurement of the instantaneous two-dimensional velocity fields in the transition region of a three-dimensional jet issuing from a rectangular nozzle with aspect ratio 4. The experiments were performed using an air jet at a Reynolds number based on the hydraulic diameter of 3600. The rollup of the laminar shear layer into vortices and their subsequent interactions are examined.

Lourenco, L.↗

Optical Studies of Active Comets

This grant was to support optical studies of comets close enough to the sun to be outgassing. The main focus of the observations was drawn to the two extraordinarily bright comets Hyakutake and Hale-Bopp, but other active comets were also studied in detail during the period of funding. Major findings (all fully published) under this grant include: (1) Combined optical and submillimeter observations of the comet/Centaur P/Schwassmann-Wachmann 1 were used to study the nature of mass loss from this object. The submillimeter observations show directly that the optically prominent dust coma is ejected by the sublimation of carbon monoxide. Simultaneous optical-submillimeter observations allowed us to test earlier determinations of the dust mass loss rate. (2) We modelled the rotation of cometary nuclei using time-resolved images of dust jets as the primary constraint. (3) We obtained broad-band optical images of several comets for which we subsequently attempted submillimeter observations, in order to test and update the cometary ephemerides. (4) Broad-band continuum images of a set of weakly active comets and, apparently, inactive asteroids were obtained in BVRI using the University of Hawaii 2.2-m telescope. These images were taken in support of a program to test the paradigm that many near-Earth asteroids might be dead or dormant comets. We measured coma vs. nucleus colors in active comets (finding that coma particle scattering is different from, and cannot be simply related to, nucleus color). We obtained spectroscopic observations of weakly active comets and other small bodies using the HIRES spectrograph on the Keck 10-m telescope. These observation place sensitive limits to outgassing from these bodies, aided by the high (40,000) spectral resolution of HIRES.

Jewitt, David↗

Chromosome Analysis

Perceptive Scientific Instruments, Inc., provides the foundation for the Powergene line of chromosome analysis and molecular genetic instrumentation. This product employs image processing technology from NASA's Jet Propulsion Laboratory and image enhancement techniques from Johnson Space Center. Originally developed to send pictures back to earth from space probes, digital imaging techniques have been developed and refined for use in a variety of medical applications, including diagnosis of disease.

Source record↗