Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isotope quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Xenon Quality Control Materials Production

Idaho National Laboratory provides xenon radionuclide samples and standards containing 131mXe, 133Xe, 133mXe, and 135Xe in a variety of matrices and container types. Activities can range from 0.5 Bq to 30 kBq, depending on the radionuclide. The methods used to produce radiometrically pure 131mXe and 133Xe as well as mixed isotope 133m/133Xe and 135/133/133mXe samples will be discussed. Limitations of the production methods will also be covered. Quantification of the radionuclides is done by HPGe detector assays. The current calibration methods as well as the calibration methods currently under development will also be discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global Framework for Emulation of Nuclear Calculations

We introduce a hierarchical framework that combines ab initio many-body calculations with a Bayesian neural network, developing emulators capable of accurately predicting nuclear properties across isotopic chains simultaneously and being applicable to different regions of the nuclear chart. We benchmark our developments using the oxygen isotopic chain, achieving accurate results for ground-state energies and nuclear charge radii, while providing robust uncertainty quantification. Our framework enables global sensitivity analysis of nuclear binding energies and charge radii with respect to the low-energy constants that describe the nuclear force.

FOS: Computer and information sciences↗

Motivations for early high-profile FRIB experiments

This white paper is the result of a collaboration by many of those that attended a workshop at the facility for rare isotope beams (FRIB), organized by the FRIB Theory Alliance (FRIB-TA), on ‘Theoretical Justifications and Motivations for Early High-Profile FRIB Experiments’. It covers a wide range of topics related to the science that will be explored at FRIB. After a brief introduction, the sections address: section 2: Overview of theoretical methods, section 3: Experimental capabilities, section 4: Structure, section 5: Near-threshold Physics, section 6: Reaction mechanisms, section 7: Nuclear equations of state, section 8: Nuclear astrophysics, section 9: Fundamental symmetries, and section 10: Experimental design and uncertainty quantification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Facile Electrochemical Mg-Ion Transport in a Defect-Free Spinel Oxide

Inversion, i.e. Mg/Mn antisite disorder, in a spinel oxide simultaneously causes blockage of favorable Mg 2+ migration paths, raising activation barriers for diffusion, and it reduces the number of redox-active metals, limiting the maximum capacity in the spinel. Here, an inversion-free spinel, MgCr 1.5 Mn 0.5 O 4 , was synthesized by exploiting the different intrinsic crystal field stabilization of redox-active Cr and Mn in the form of a solid-solution. The capability of the tailored spinel to reversibly (de)intercalate Mg 2+ at high redox potentials was investigated. The decrease in inversion dramatically lowered the electrochemical overpotential and hysteresis, and enabled utilization of high potentials at ~2.9 V (vs. Mg/Mg 2+ ) upon re-intercalation of Mg 2+ . A combination of characterization techniques reveals that the structural, compositional, and redox changes within the spinel oxide were consistent with the observed electrochemical Mg 2+ activity. Quantification of selective solely to lattice Mg 2+ upon the electrochemical reaction was investigated by monitoring NMR signals in isotope 25 Mg-enriched spinel oxides. Our findings enhance the understanding of Mg 2+ transport within spinel oxide frameworks and provide conclusive evidence for bulk Mg migration in oxide lattices at high redox potentials with minimized electrochemical hysteresis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing a peptide concatemer (PepCon) as a process control for LC-MS based proteomics

Quantitative concatenated peptide (QconCAT) technology is currently used for the absolute quantification of proteins of interest in a biological sample. It relies on artificially created proteins that are concatenations of different, isotopically labeled peptides. Because these isotopically labeled peptides are at a 1:1 ratio and correspond to naturally occurring peptides in the biological sample, each peptide can be used as a standard for the absolute quantitation of all proteins of interest at once. Although the QconCAT technology has utility for quantitation of known peptides in a mixture, it is not helpful for scientists who need a proteomics standard (1) that can be spiked into a protein mixture at an extremely low level, (2) that can be co-purified during sample fractionation, and (3) that is optimized for ESI used in mass spectrometry. Thus, there exists a need for an ideal standard protein that is large enough to behave as a protein but consists of multiple, concatenated copies of the same peptide, which, upon digestion, amplifies (e.g., >10-fold) into a detectable peptide species. Here, this technical report describes the development of “PepCon”, a peptide concatemer that fulfills this unmet need.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consistent $\overline{ν}$ evaluation for minor Pu isotopes with CGMF

This report follows up on the evaluation work done in 2023 where we developed a procedure and performed the first consistent evaluation of the average prompt neutron multiplicity for minor Pu isotopes, including 238,240-242 Pu, using CGMF. Details on the necessary updates to the release version of CGMF, the experimental data and experimental uncertainty quantification that went into the evaluation, and this first evaluation effort are documented in and will not be repeated in this report. Instead, we discuss here the further investigations into the CGMF model space to improve the evaluation results from FY23. Additionally, we note that these evaluation results have been transformed into the ENDF format for mean values and covariances, and validation with critical assemblies has been performed; that work is documented elsewhere. In this short report, we discuss the updated evaluation efforts performed during FY24 in Sec. 2, show results from CGMF for other prompt fission observables in Sec. 3, and then briefly conclude in Sec. 4.

07 ISOTOPE AND RADIATION SOURCES↗

An improved method for uranium separation from urine for rapid bioassay by inductively coupled plasma mass spectrometry

Bioassay monitoring is an important capability for any facility that works with significant amounts of radioactive material. The speed at which these analyses can be made is critical in the event of a potential exposure. Here, we present a new method that facilitates the rapid separation of uranium from a urine matrix for assay and isotopic determination by inductively coupled plasma mass spectrometry. This method is validated with archived urine samples that were previously analyzed using established, more time consuming methods. The sources of uncertainty for uranium assay and isotopic measurements are modelled using the Monte Carlo method to better understand the precision and accuracy of this method at the limit of quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Predicting the neutrinoless double-β-decay matrix element of 136 Xe using a statistical approach

Calculation of the nuclear matrix elements (NMEs) for double-β decay is of paramount importance for guiding experiments and for analyzing and interpreting the experimental data, especially for the search of the neutrinoless double β decay mode (0v⁢ββ). However, there are currently still large differences between the NME values calculated by different methods, hence a quantification of their uncertainties is very much required. Here, in this paper, we propose a statistical analysis of 0⁢v⁢ββ NME for the 136 Xe isotope, based on the interacting shell model, but using three independent effective Hamiltonians, emphasizing the range of the NMEs' most probable values and its correlations with observables that can be obtained from the existing nuclear data. Consequently, we propose a common probability distribution function for the 0⁢vββ NME, which has a range of (1.55–2.65) at 90% confidence level, with a mean value of 1.99 and a standard deviation of 0.37.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Controlling radioisotope proportions when randomly sampling from Dirichlet distributions in PyRIID

As machine learning models for radioisotope quantification become more powerful, likewise the need for high-quality synthetic training data grows as well. For problem spaces that involve estimating the relative isotopic proportions of various sources in gamma spectra it is necessary to generate training data that accurately represents the variance of proportions encountered. In this report, we aim to provide guidance on how to target a desired variance of proportions which are randomly when using the PyRIID Seed Mixer, which samples from a Dirichlet distribution. We provide a method for properly parameterizing the Dirichlet distribution in order to maintain a constant variance across an arbitrary number of dimensions, where each dimension represents a distinct source template being mixed. We demonstrate that our method successfully parameterizes the Dirichlet distribution to target a specific variance of proportions, provided that several conditions are met. This allows us to follow a principled technique for controlling how random mixture proportions are generated which are then used downstream in the synthesis process to produce the final, noisy gamma spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Contributions to the ENDF/B-VIII.1 Library [Slides]

For uranium and plutonium isotopes, evaluation work is converging to a stable configuration with an overall satisfactory benchmark performance (more information on the validation tests after CSEWG). Strontium evaluation was included in the repository library and successfully tested by processing codes relative to an alternative quantification of the external function. Cerium covariance matrices were updated to address review comments on the magnitude of the uncertainty. For future uncertainty quantification, theoretical observables should be properly decoupled from current measured guidelines. Tests to correctly include LP (from resonance parameters) fitted to measured energy-averaged data are in progress. Current ENDF files contains experimental LP data.

07 ISOTOPE AND RADIATION SOURCES↗

Capillary absorption spectroscopy for high temporal resolution measurements of stable carbon isotopes in soil and plant-based systems

Capillary Absorption Spectroscopy (CAS) is a relatively new analytical technique for performing stable isotope analysis. Here, we demonstrate the utility of CAS by recording and quantifying variation in 13C in controlled and biologically relevant applications. We calibrated CAS system response to increased 13CO2, with an observed ~4‰ increase in measured Δ13C for each 0.03 ppm shift in 13CO2 concentration. We leveraged this calibration to quantify rates of biogeochemical processes using a 13C tracer. For example, we monitored microbial respiration of 13C-glucose within an agricultural soil at 10 s quantification intervals and results demonstrated 8.6% ± 0.4 of added glucose was converted to 13CO2 within 1.5 h of incubation. We expanded the demonstration by adapting a rhizobox to permit continuous monitoring of 13CO2 in a soil (as distinct from plant) headspace to track the timing and quantify respiration rates of fresh plant photosynthate and observed a 3.5 h delay between plant exposure to a13CO2 tracer and the first signs of respiration by soil biota. These experiments highlight CAS is effective in producing high temporal resolution quantification of 13CO2 and demonstrate potential applications.

13CO2↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear data uncertainty quantification for the nuclide inventory of a Calvert Cliffs spent fuel sample

The impact of nuclear data cross section uncertainties and covariance matrices on the nuclide vector of spent nuclear fuel was investigated; This exercise was carried out for the Calvert Cliffs fuel assembly D047 benchmark available in the SFCOMPO database. Sample P irradiated in rod MKP109 for 4 cycles up to a burnup of approximately 44 GWd/MTU was selected for the analysis. Nuclear data uncertainties were taken from the most recent libraries released by evaluation projects JEFF, ENDF/B and JENDL, and were propagated using the SANDY code via a stochastic sampling approach. This paper provides a quantification of the uncertainty on the concentration of several actinides and fission products relevant for spent fuel management. Uncertainties generally below 5 % were predicted for the concentrations of most of the uranium, neptunium and plutonium isotopes relevant for SNF applications. Curium isotopes carry larger uncertainties that might exceed 10 %. The contribution of cross section uncertainties on the concentrations of fission products was found to be marginal with the exception of a few nuclides. These results can be significantly affected by the lack of evaluated covariance matrices for the capture cross section of several fission products. Burnup tracers such as {sup 148}Nd and {sup 137}Cs have negligible uncertainties because of the power normalisation imposed in every stochastic calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retaining Geochemical Signatures during Aragonite-Calcite Transformation at Hydrothermal Conditions

Transformation of aragonite, a mineral phase metastable at Earth’s surface, to calcite widely occurs in both sedimentary and metamorphic systems with the presence of an aqueous phase. The transformation process can affect geochemical signatures of aragonite (a protolith). This study focused on quantification of the retention of Mg/Ca and Sr/Ca ratios, and δ18O during the transformation process as well as evaluation of the transformation rate. To investigate the effect of transformation from aragonite to calcite on elemental and stable isotope ratios, we conducted a series of experiments in NaCl solutions at temperatures between 120 and 184 °C. Two additional experiments at 250 °C were conducted to estimate the transformation rate of aragonite to calcite. Protolith materials consist of (1) synthetic (Mg; Sr-bearing or non-Mg; Sr bearing) needle-shaped microcrystals of aragonite (<5 µm in size) and (2) larger chips (>100 µm in size) of natural aragonite. X-ray diffraction (XRD) showed that microcrystals successfully transformed to calcite within 30 h and scanning electron microscopy (SEM) yielded a change in the crystal size to >10 µm in rhombohedral shape. Electron backscatter diffraction (EBSD) of the larger aragonite chips showed that transformation to randomly oriented calcite occurred at the rims and along the cracks while the core retained an aragonite crystal structure. Isotope-ratio mass spectrometry (IRMS) analyses showed that calcite δ18O was controlled by temperature and δ18O of the solution. The obtained calibration curve of isotope fractionation factor versus temperature is consistent with other studies. Inductively coupled plasma optical emission spectroscopy (ICP-OES) analyses showed that calcite partially or completely retained Mg/Ca and Sr/Ca ratios through the transformation.

58 GEOSCIENCES↗