Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multiple-beam fibre reflection interferometer based on an all-dielectric diffraction structure

We report experiments aimed at making a fibre reflection interferometer based on all-dielectric diffraction structures for the range 1500–1600 nm. The diffractive scattering structure of the input mirror of the interferometer is produced on the fibre end face by damaging it using abrasive diamond film with a grain size of a few microns. As a result, sharp reflection peaks are obtained for two interferometers, with the following parameters: finesse, 100 and 11; contrast, 2 and 60, respectively. Such an interferometer can, in principle, combine high contrast and high finesse. (laser applications and other topics in quantum electronics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scalable Bose-Einstein-condensate Sagnac interferometer in a linear trap

We demonstrate a two-dimensional atom interferometer in a harmonic magnetic waveguide using a Bose-Einstein condensate. Such an interferometer could measure rotation using the Sagnac effect. Compared to free space interferometers, larger interactions times and enclosed areas can in principle be achieved, since the atoms are not in free fall. In this implementation, we induce the atoms to oscillate along one direction by displacing the trap center. We then split and recombine the atoms along an orthogonal direction using an off-resonant optical standing wave. We enclose a maximum effective area of 0.1 mm{sup 2} limited by fluctuations in the initial velocity and by the coherence time of the interferometer. We argue that this arrangement is scalable to enclose larger areas by increasing the coherence time and then making repeated loops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom Interferometers with Scalable Enclosed Area

Bloch oscillations (i.e., coherent acceleration of matter waves by an optical lattice) and Bragg diffraction are integrated into light-pulse atom interferometers with large momentum splitting between the interferometer arms, and hence enhanced sensitivity. Simultaneous acceleration of both arms in the same internal states suppresses systematic effects, and simultaneously running a pair of interferometers suppresses the effect of vibrations. Ramsey-Borde interferometers using four such Bloch-Bragg-Bloch beam splitters exhibit 15% contrast at 24(Planck constant/2pi)k splitting, the largest so far ((Planck constant/2pi)k is the photon momentum); single beam splitters achieve 88(Planck constant/2pi)k. The prospects for reaching 100 s of (Planck constant/2pi)k and applications such as gravitational wave sensors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-410: Fringe Stability and Phase Shift Measurements in a Michelson Interferometer for Optical Calorimetry

Purpose: To identify the variables limiting the resolution of a Michelson interferometer used to measure phase shifts (PS) in water as part of a radiometric calorimeter. Methods: We investigated the output stability of a He-Ne laser and a laser diode. The short and long term stability of the fringe pattern in a Michelson interferometer was tested with different types of lasers, thermal insulation arrangements, damping systems and optical mounts to optimize system performance. PS were induced by electrically heating water in a 1 cm quartz cuvette located in one of the interferometer arms. The PS was calculated from fringe intensity changes and compared to a calculated PS using thermocouple-measured temperature changes in the water. Results: The intensity of the laser diode is more stable, but the gas laser’s profile is more suitable for fringe analysis and has better temporal coherence. The laser requires a warm-up time of 4 hours before its output is stabilized (SNR>95). The fringe’s stability strongly depends on the thermal insulation. When the interferometer is exposed to ambient temperature swings of 0.7 K, it is not possible to stabilize the fringe pattern. Enclosing the system in a 2.5 cm-thick Styrofoam box improves the SNR, but further insulation will be needed to increase the SNR above 50. High frequency noise is significantly reduced by damping the system.Inducing a temperature rise in water, starting at 299 K, the average temperature increase for a 2π PS is 0.29 ± 0.02 K and the proportionality constant is -21.1 ± 0.8 radians/K. This is 5.8% lower than the calculated value using the thermocouple. Conclusion: Interferometric PS measurements of temperature may provide an alternative to thermistors for water calorimetry. The resolution of the current prototype is limited by ambient temperature stability. Calculated and measured thermally-induced PS in water agreed to within 5.8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses

A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of 10{sup -6}. The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as 1.1x10{sup -6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designs of multipass optical configurations based on the use of a cube corner retroreflector in the interferometer

We describe designs of the multipass optical configurations of an interferometer with high spectral resolution with respect to 6, 12, and 24 times more optical passes than the conventional Michelson interferometer. In each design, a movable cube corner retroreflector is combined with a folding reflector group (FRG) as the interferometer's moving combination to implement the multipass optical configuration with the characteristic of surface division. Analyses reveal that when there are 12 or more optical passes, the net effect of the ray's angular deviation of the entire moving combination amounts to only the alignment error of one of the reflectors in the FRG, demonstrating the self-aligning property of the interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel heterodyne displacement interferometer with no detectable periodic nonlinearity and optical resolution doubling

This paper describes a novel heterodyne laser interferometer with no significant periodic nonlinearity for linear displacement measurements. Moreover, the optical configurations have the benefit of doubling the measurement resolution when compared to its respective traditional counterparts. Experimental results show no discernable periodic nonlinearity for a retro-reflector interferometer and plane mirror interferometer configurations with a noise level below 20 pm. The incoming laser beams of the interferometers are achieved by utilizing two single mode optical fibers. To determine the stability of the optical fiber couplers a fiber delivery prototype was also built and tested.

42 ENGINEERING↗

Spatially translatable optical fiber-coupled heterodyne interferometer

An interferometer is a useful diagnostic tool for measuring line-averaged electron density but is limited in its use because it generally measures at a fixed location. Here, we report here a spatially translatable fiber-coupled interferometer that measures the density of a high-speed MHD-driven plasma jet colliding with a target cloud. The interferometer uses a He–Ne laser coupled to a polarization-maintaining single mode optical fiber having a vacuum feedthrough. Lastly, the interferometer provides a measure of the spatial-temporal profile of the line-averaged electron density from which the change in jet velocity as a result of its collision with the target cloud can be deduced.

47 OTHER INSTRUMENTATION↗

Slow Quasiparticle Dynamics and Anyonic Statistics in a Fractional Quantum Hall Fabry-Pérot Interferometer

Anyons are two-dimensional particles with fractional exchange statistics that emerge as elementary excitations of fractional quantum Hall phases. Experimentally, their exchange statistics can be measured in the edge-state Fabry-Pérot interferometer, wherein the presence of 𝑁 𝑞⁢𝑝 localized anyons contributes a phase 𝑁 𝑞⁢𝑝⁢ 𝜃 𝑎 to the interference pattern where 𝜃 𝑎 is twice the exchange phase. Here we report the observation of large, hysteretic phase jumps in a monolayer graphene Fabry-Pérot interferometer at 𝜈 = 1/3. When the filling factor is increased from 𝜈 < 1/3 toward the center of the plateau, we observe phase slips with magnitude Δ⁢𝜃 ≈ 2⁢𝜋/3, consistent with the addition of individual quasiparticles to the interferometer bulk. These phase slips occur as instantaneous jumps in the interference signal, with intervals between the jumps indicating quasiparticle equilibration times exceeding 20 min. We use this long timescale to investigate the effect of changes in interferometer area 𝐴 𝐼 and 𝑁 𝑞⁢𝑝 independently at fixed magnetic field, revealing a striking memory effect in the phase slip magnitude. In particular, as the 𝜈 =1/3 plateau is approached from higher filling, we observed phase slips with Δ⁢𝜃 significantly larger than 2⁢𝜋/3 over the same range of gate voltage where quantized jumps are seen for increasing 𝜈. We discuss this asymmetry in terms of bulk-edge coupling of quasiparticles localized near the edge or in the bulk, and argue that this effect can be qualitatively reconciled with theoretical expectations for strongly interacting quasiparticles in the presence of weak disorder and strongly nonequilibrium charge dynamics. Besides providing a replication of interferometric measurements sensitive to 𝜃 𝑎 , our results highlight the key role played by charge dynamics on signatures of the anyon phase, and demonstrate that fractional quasiparticles can be indefinitely localized in nonequilibrium configurations.

anyons↗

Dynamical quantum phase transitions in interacting atomic interferometers

Particle-wave duality has allowed physicists to establish atomic interferometers as celebrated complements to their optical counterparts in a broad range of quantum devices. In particular, interactions give rise to multiparticle correlations unavailable in linear interferometers. Here, we show that interactions lead to dynamical quantum phase transitions (DQPTs) between NOON states in an atomic interferometer. These transition points result from zeros of the Loschmidt echo, which approach the real axis of the complex time plane in the large-particle-number limit, and signify pair condensates, another type of exotic quantum states featured with prevailing two-body correlations. Such DQPTs thus provide us with a new angle to understand many-body states emergent from quantum nonequilibrium dynamics. Further, our work also suggests interacting atomic interferometers as a new tool for creating highly entangled states to beat the standard quantum limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron interferometer crystallographic imperfections and gravitationally induced quantum interference measurements

Dynamical diffraction leads to an interesting, unavoidable set of interference effects for neutron interferometers. This experiment studies the interference signal from two and three successive Bragg diffractions in the Laue geometry. We find that intrinsic Bragg-plane misalignment in monolithic, “perfect” silicon neutron interferometers is relevant between successive diffracting crystals, as well as within the Borrmann fan for typical interferometer geometries. Furthermore, we show that the dynamical phase correction employed in the Colella, Overhauser, and Werner gravitationally induced quantum interference experiments is attenuated by slight, intrinsic misalignments between diffracting crystals, potentially explaining the long-standing 1% discrepancy between theory and experiment. This systematic may also impact precision measurements of the silicon structure factor, affecting previous and future measurements of the Debye-Waller factor and neutron-electron scattering length as well as potential fifth-force searches. For the interferometers used in this experiment, Bragg planes of different diffracting crystals were found to be misaligned by 10 to 40 nrad.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometer response to geontropic fluctuations

We model vacuum fluctuations in quantum gravity with a scalar field, characterized by a high occupation number, coupled to the metric. The occupation number of the scalar is given by a thermal density matrix, whose form is motivated by fluctuations in the vacuum energy, which have been shown to be conformal near a light-sheet horizon. For the experimental measurement of interest in an interferometer, the size of the energy fluctuations is fixed by the area of a surface bounding the volume of spacetime being interrogated by an interferometer. We compute the interferometer response to these “geontropic” scalar-metric fluctuations, and apply our results to current and future interferometer measurements, such as LIGO and the proposed GQuEST experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry↗

Naturally stable Sagnac–Michelson nonlinear interferometer

Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9% interference visibility and find evidence for noise reduction based on phase-sensitive gain. As a result, our configuration utilizes fewer components than previous demonstrations and requires no active stabilization, offering new capabilities for practical nonlinear interferometric-based sensors.

47 OTHER INSTRUMENTATION↗

Two-path plasmonic interferometer with integrated detector

An electrically tunable terahertz two-path plasmonic interferometer with an integrated detection element can down convert a terahertz field to a rectified DC signal. The integrated detector utilizes a resonant plasmonic homodyne mixing mechanism that measures the component of the plasma waves in-phase with an excitation field that functions as the local oscillator in the mixer. The plasmonic interferometer comprises two independently tuned electrical paths. The plasmonic interferometer enables a spectrometer-on-a-chip where the tuning of electrical path length plays an analogous role to that of physical path length in macroscopic Fourier transform interferometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lateral Shearing Interferometer for Measuring Photoinduced Refractive Index Change in As2S3

We have built and demonstrated a lateral shearing interferometer as a process engineering and control tool for the fabrication and characterization of direct-laser-written waveguide structures in chalcogenide glasses. Photoinduced change in refractive index of 0.154 ± 0.002 was measured for as-deposited amorphous As2S3 thin films at 633 nm with an estimated measurement accuracy of 1.3% for this air-gap interferometer configuration. The simple design of this interferometer can very easily be adapted to other wavelengths including mid- and long-wave infrared regions to measure changes in refractive index or material inhomogeneities in transmissive materials.

36 MATERIALS SCIENCE↗

EIT Based Gas Detector Design by Using Michelson Interferometer

Electromagnetically induced transparency (EIT) is one of the interesting phenomena of light-matter interaction which modifies matter properties for propagation of light. In other words, we can change the absorption and refractive index (RI) in neighborhood of the resonant frequency using EIT. In this paper, we have doped 3-level quantum dots in one of the Michelson Interferometer's mirror and used EIT to change its RI. So, a controllable phase difference between lights in two arms of interferometer is created. Long response time is the main drawback of Michelson interferometer based sensor, which is resolved by this technique.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of Young-Michelson and Brown-Twiss interferometers for determining geometric parameters of nonplanar rough objects

The possibility of using Young-Michelson and Brown-Twiss interferometers for measuring the angular dimensions and parameters of the surface shape of remote passively scattering and self-luminous nonplanar rough objects by optical radiation propagating from them is substantiated. The analysis is based on the properties of approximate transverse functions of field coherence B{sub t} and B{sub t}' and intensity coherence B{sub ti} and B{sub ti}' formed by the time averaging of the products of fields and intensities taken at two points of a receiving aperture (the prime denotes self-luminous objects). The averaging time is set to be much longer than the coherence time of radiation propagating from an object. It is shown that for the radiation coherence length much smaller than the depth of the visible region of the object, the functions B{sub t} and B{sub t}' are proportional to the Fourier transform of the intensity distribution in the image of a remote object, which is the generalisation of the Van Cittert-Zernicke theorem to the case of a nonplanar object, while functions B{sub ti} and B{sub ti}' are proportional to the squares of the modulus of the Fourier transform of this distribution. It is also shown that the recording of functions B{sub t} and B{sub t}' with a Young-Michelson interferometer gives only the angular dimensions of the visible region of objects, whereas the recording of functions B{sub ti} and B{sub ti}' with a Brown-Twiss interferometer allows one to find these dimensions and the radius of curvature of the object surface. (laser radiation scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗