Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insulation damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hypervelocity impact damage assessment for Space Station

To inhibit damage and limit the probability of penetration of the Space Station pressure wall by micrometeoroids and orbital debris, a shield placed away from the wall is used to form a double wall. To determine shield effectiveness and assess impact damage, existing test data were reviewed and additional testing was performed for Space Station double wall designs. Empirical spallation and penetration functions derived from the data show that shield thickness and impact angle affect the damage to the wall. Thick shields reduce wall damage for low angle impacts but increase damage for oblique impacts. Multilayer insulation between the shield and wall reduces impact damage to the wall. A relationship between impact velocity and spall damage to the wall is demonstrated. Preliminary test results on Li-Al shield material indicate possible improved effectiveness over Al shields.

Coronado, Alex R.↗

STS-27R OV-104 Orbiter TPS damage review team, volume 1

Following the return to earth on December 2, 1988, of Orbiter OV-104, Atlantis, it was observed that there was substantial Thermal Protection System (TPS) tile damage present on the lower right fuselage and wing. Damage sites were more numerous than on previous flights and conversely, there was almost no damage present on Atlantis' left side. A review team investigated the cause beginning with a detailed inspection of the Atlantis TPS damage, and a review of related inspection reports to establish an indepth anomaly definition. An exhaustive data review followed. A fault tree and several failure scenarios were developed. Finally, the failure scenarios were categorized as either not possible, possible but not probable, or probable. This and other information gained during the review formed the basis for the team's findings and recommendations. The team concluded that the most probable cause of the severe STS-27R Orbiter tile damage is that the ablative insulating material covering the RH SRB Nose Cap dislodged and struck the Orbiter tile near 85 seconds into flight and possibly that debris from other sources, including repaired insulation and missing joint cork, caused minor tile damage. Findings are presented, and recommendations that are believed pertinent to minimizing the potential for inflight debris are described.

Thomas, John W.↗

Laser Wire Stripper

NASA-developed space shuttle technology is used in a laser wire stripper designed by Raytheon Company. Laser beams cut through insulation on a wire without damaging conductive metal, because laser radiation that melts plastic insulation is reflected by the metal. The laser process is fast, clean, precise and repeatable. It eliminates quality control problems and the expense of rejected wiring.

Source record↗

Local aging effects in PuB 4 : Growing inhomogeneity and slow dynamics of local field fluctuations probed by 239 Pu NMR

Plutonium-based correlated electron materials host exotic physical phenomena ranging from unconventional heavy-fermion superconductivity to topological Kondo insulating states. Self-irradiation damage can influence many properties of such radioactive materials. Structural disorder effects due to α radiation have been frequently studied using techniques such as transport, thermodynamics, and x-ray diffraction. Here, in this study, we use 239 Pu nuclear magnetic resonance (NMR) to study the long-term influence of self-damage on the lattice and local electronic structures in a single crystal of the candidate topological insulator plutonium tetraboride (PuB 4 ). We first characterize the anisotropy of the 239 Pu resonance and confirm the local axial-site symmetry inferred from previous polycrystalline measurements. Aging effects are then evaluated over the time frame of six years. We find that, though the static 239 Pu NMR spectra show a slight modulation in their shape, their field-rotation pattern reveals no change in 239 Pu local site symmetry over time, suggesting that aging has a surprisingly small impact on the spatial distribution of the static hyperfine field. Further, ligand-site 11 B NMR finds little time-dependent change in the size of electric field gradient around 11 B sites. By contrast, aging has a prominent impact on the 239 Pu NMR relaxation processes and signal intensity. Specifically, aging-induced damage manifests itself as an increase in the spin-lattice relaxation time 𝑇 1 , an increased distribution of 𝑇 1 , and a signal intensity that decreases linearly by 20% per year. An effective spin-spin relaxation time 𝑇 2,eff in the aged sample shortens drastically towards lower temperature, suggesting growth of slow fluctuations of the hyperfine field that are linked to radiation-damage-induced inhomogeneity. Our NMR study sheds light on the interplay of radiation damage and local magnetic interactions in correlated insulators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spaced Orthocyclic Winding Pattern for Improved Die Compressed Coils

Winding fill, coil fill, or packing factor, is critical to the performance of many types of electromagnetic devices from electric machines to actuators, transformers, inductors, etc. One technique to increase the packing of conductors in the winding area is to compress round magnet wire conductors in a die, so that they deform and air voids between coil turns are removed. The winding layout of the coil turns on a bobbin before compression has a direct impact on the achievable coil fill and the damage to the coil insulation or conductors after compression. It is thought that winding the turns in an orthocyclic pattern on the bobbin before compression would minimize damage to the turns. This however causes turns to displace during the winding compression process. A new pre-compression winding pattern is proposed, a spaced orthocyclic winding, to minimize turn displacement and damage. A design of experiments study has been carried out to optimize this winding method and to compare it to the traditional orthocyclic winding.

33 ADVANCED PROPULSION SYSTEMS↗

Micromechanical simulation of damage progression in carbon phenolic composites

Carbon/phenolic composites are used extensively as ablative insulating materials in the nozzle region of solid rocket motors. The current solid rocket motor (RSRM) on the space shuttle is fabricated from woven rayon cloth which is carbonized and then impregnated with the phenolic resin. These plies are layed up in the desired configuration and cured to form the finished part. During firing, the surface of the carbon/phenolic insulation is exposed to 5000 F gases from the rocket exhaust. The resin pyrolizes and the material chars to a depth which progresses with time. The rate of charring and erosion are generally predictable, and the insulation depth is designed to allow adequate safety margins over the firing time of the motor. However, anomalies in the properties and response of the carbon/phenolic materials can lead to severe material damage which may decrease safety margins to unacceptable levels. Three macro damage modes which were observed in fired nozzles are: ply lift, 'wedge out', and pocketing erosion. Ply lift occurs in materials with plies oriented nearly parallel to the surface. The damage occurs in a region below the charred material where material temperatures are relatively low - about 500 F. Wedge out occurs at the intersection of nozzle components whose plies are oriented at about 45 deg. The corner of the block of material breaks off along a ply interface. Pocketing erosion occurs in material with plies oriented normal to the surface. Thermal expansion is restrained in two directions resulting in large tensile strains and material failure normal to the surface. When a large section of material is removed as a result of damage, the insulation thickness is reduced which may lead to failure of the nozzle due to excessive heating of critical components. If these damage events cannot be prevented with certainty, the designer must increase the thickness of the insulator thus adding to both weight and cost. One of the difficulties in developing a full understanding of these macro damage mechanisms is that the loading environment and the material response to that environment are extremely complex. These types of damage are usually only observed in actual motor firings. Therefore, it is difficult and expensive to evaluate the reliability of new materials. Standard material tests which measure mechanical and thermal properties of test specimens can only provide a partial picture of how the material will respond in the service environment. The development of the ANALOG test procedure which can combine high heating rates and mechanical loads on a specimen will improve the understanding of the interactive effects of the various loads on the system. But a mechanistic model of material response which can account for the heterogeneity of the material, the progression of various micromechanical damage mechanisms, and the interaction of mechanical and thermal stresses on the material is required to accurately correlate material tests with response to service environments. A model based on fundamental damage mechanisms which is calibrated and verified under a variety of loading conditions will provide a general tool for predicting the response of rocket nozzles. The development of a micromechanical simulation technique was initiated and demonstrated to be effective for studying across-ply tensile failure of carbon/phenolic composites.

Slattery, Kerry T.↗

Post Test Evaluation of HSCT Nozzle Acoustic Liner Subcomponents Subjected to a Hot Acoustic Durability Test

The acoustic liner system designed for use in the High Speed Civil Transport (HSCT) was tested in a thermal-acoustic environment. Five ceramic matrix composite (CMC) acoustic tile configurations, five bulk acoustic absorbers, and one thermal protection system design were tested. The CMC acoustic tiles were subjected to two 2 3/4 hr ambient temperature acoustic exposures to measure their dynamic response. One exposure was conducted on the tiles alone and the second exposure included the tiles and the T-foam bulk absorber. The measured tile RMS strains were small. With or without the T-foam absorber, the dynamic strains were below strain levels that would cause damage during fatigue loading. After the ambient exposure, a 75-hr durability test of the entire acoustic liner system was conducted using a thermal-acoustic cycle that approximated the anticipated service cycle. Acoustic loads up to 139 dB/Hz and temperatures up to 1670 F (910 C) were employed during this 60 cycle test. During the durability test, the CMC tiles were exposed to temperatures up to 1780 F and a transient through thickness gradient up to 490 F. The TPS peak temperatures on the hot side of the panels ranged from 750 to 1000 F during the 60 cycles. The through thickness delta T ranged from 450 to 650 F, varying with TPS location and cycle number. No damage, such as cracks or chipping, was observed in the CMC tiles after completion of the testing. However, on tile warped during the durability test and was replaced after 43 or 60 cycles. No externally observed damage was found in this tile. No failure of the CMC fasteners occurred, but damage was observed. Cracks and missing material occurred, only in the fastener head region. No indication of damage was observed in the T-foam acoustic absorbers. The SiC foam acoustic absorber experienced damage after about 43 cycles. Cracking in the TPS occurred around the attachment holes and under a vent. In spite of the development of damage, the TPS maintained its insulative capability throughout the durability test. The durability test results demonstrate damage-tolerant CMC tile, CMC fastener, TPS, and T-foam absorber designs for the combined thermal and acoustic engine nozzle environment.

Verrilli, Michael J.↗

In-Situ Wire Damage Detection System

An In-Situ Wire Damage Detection System (ISWDDS) has been developed that is capable of detecting damage to a wire insulation, or a wire conductor, or to both. The system will allow for realtime, continuous monitoring of wiring health/integrity and reduce the number of false negatives and false positives while being smaller, lighter in weight, and more robust than current systems. The technology allows for improved safety and significant reduction in maintenance hours for aircraft, space vehicles, satellites, and other critical high-performance wiring systems for industries such as energy production and mining. The integrated ISWDDS is comprised of two main components: (1) a wire with an innermost core conductor, an inner insulation film, a conductive layer or inherently conductive polymer (ICP) covering the inner insulation film, an outermost insulation jacket; and (2) smart connectors and electronics capable of producing and detecting electronic signals, and a central processing unit (CPU) for data collection and analysis. The wire is constructed by applying the inner insulation films to the conductor, followed by the outer insulation jacket. The conductive layer or ICP is on the outer surface of the inner insulation film. One or more wires are connected to the CPU using the smart connectors, and up to 64 wires can be monitored in real-time. The ISWDDS uses time domain reflectometry for damage detection. A fast-risetime pulse is injected into either the core conductor or conductive layer and referenced against the other conductor, producing transmission line behavior. If either conductor is damaged, then the signal is reflected. By knowing the speed of propagation of the pulse, and the time it takes to reflect, one can calculate the distance to and location of the damage.

Williams, Martha↗

WSTF electrical arc projects

The objectives of these projects include the following: validate method used to screen wire insulation with arc tracking characteristics; determine damage resistance to arc as a function of source voltage and insulation thickness; investigate propagation characteristics of Kapton at low voltages; and investigate pyrolytic properties of polyimide insulated (Kapton) wire for low voltage (less than 35 VDC) applications. Supporting diagrams and tables are presented.

Linley, Larry↗

Shielding requirements for the Space Station habitability modules

The design, analysis, development, and tests of the total meteoroid/debris protection system for the Space Station Freedom habitability modules, such as the habitation module, the laboratory module, and the node structures, are described. Design requirements are discussed along with development efforts, including a combination of hypervelocity testing and analyses. Computer hydrocode analysis of hypervelocity impact phenomena associated with Space Station habitability structures is covered and the use of optimization techniques, engineering models, and parametric analyses is assessed. Explosive rail gun development efforts and protective capability and damage tolerance of multilayer insulation due to meteoroid/debris impact are considered. It is concluded that anticipated changes in the debris environment definition and requirements will require rescoping the tests and analysis required to develop a protection system.

Avans, Sherman L.↗

Simulated Solar Flare X-Ray and Thermal Cycling Durability Evaluation of Hubble Space Telescope Thermal Control Candidate Replacement Materials

During the Hubble Space Telescope (HST) second servicing mission (SM2), astronauts noticed that the multilayer insulation (MLI) covering the telescope was damaged. Large pieces of the outer layer of MLI (aluminized Teflon fluorinated ethylene propylene (Al-FEP)) were torn in several locations around the telescope. A piece of curled up Al-FEP was retrieved by the astronauts and was found to be severely embrittled, as witnessed by ground testing. Goddard Space Flight Center (GSFC) organized a HST MLI Failure Review Board (FRB) to determine the damage mechanism of FEP in the HST environment, and to recommend replacement insulation material to be installed on HST during the third servicing mission (SM3) in 1999. Candidate thermal control replacement materials were chosen by the FRB and tested for environmental durability under various exposures and durations. This paper describes durability testing of candidate materials which were exposed to charged particle radiation, simulated solar flare x-ray radiation and thermal cycling under load. Samples were evaluated for changes in solar absorptance and tear resistance. Descriptions of environmental exposures and durability evaluations of these materials are presented.

deGroh, Kim K.↗

Low-damage electron beam lithography for nanostructures on Bi 2 Te 3 -class topological insulator thin films

Nanostructured topological insulators (TIs) have the potential to impact a wide array of condensed matter physics topics, ranging from Majorana physics to spintronics. However, the most common TI materials, the Bi 2 Se 3 family, are easily damaged during nanofabrication of devices. In this paper, we show that electron beam lithography performed with a 30 or 50 kV accelerating voltage—common for nanopatterning in academic facilities—damages both nonmagnetic TIs and their magnetically doped counterparts at unacceptable levels. We additionally demonstrate that electron beam lithography with a 10 kV accelerating voltage produces minimal damage detectable through low-temperature electronic transport. In conclusion, although reduced accelerating voltages present challenges in creating fine features, we show that with careful choice of processing parameters, particularly the resist, 100 nm features are reliably achievable.

42 ENGINEERING↗

Application of Ultrasonic Guided Waves for Evaluating Aging Wire Insulation

Aging wiring has become a critical issue to the aerospace and aircraft industries due to Shuttle and aircraft incidents. The problem is that over time the insulation on wire becomes brittle and cracks. This exposes the underlying conductive wire to the potential for short circuits and fire. Popular methods of monitoring aging wire problems focuses on applying electrical sensing techniques that are sensitive to the conductor's condition, but not very sensitive to the wire insulation's condition. Measurement of wire insulation stiffness and ultrasonic properties by ultrasonic guided waves is being examined. Experimental measurements showed that the lowest order extensional mode could be sensitive to stiffness changes in the wire insulation. To test this theory conventional wire samples were heat damaged in an oven, in a range of heating conditions. The samples were 12, 16, and 20 gauge and the heat damage introduced material changes in the wire insulation that made the originally flexible insulation brittle and darker in color. Results showed that extensional mode phase velocity increased for the samples that were exposed to heat for longer duration.

Anastasi, Robert F.↗

Development and simulation study of a new inverse-pinch high Coulomb transfer switch

The inverse-pinch plasma switch was studied using a computer simulation code. The code was based on a 2-D, 2-temperature magnetohydrodynamic (MHD) model. The application of this code was limited to the disk-type inverse-pinch plasma switch. The results of the computer analysis appear to be in agreement with the experimental results when the same parameters are used. An inverse-pinch plasma switch for closing has been designed and tested for high-power switching requirements. An azimuthally uniform initiation of breakdown is a key factor in achieving an inverse-pinch current path in the switch. Thus, various types of triggers, such as trigger pins, wire-brush, ring trigger, and hypocycloidal-pinch (HCP) devices have been tested for uniform breakdown. Recently, triggering was achieved by injection of a plasma-ring (plasma puff) that is produced separately with hypocycloidal-pinch electrodes placed under the cathode of the main gap. The current paths at switch closing, initiated by the injection of a plasma-ring from the HCP trigger are azimuthally uniform, and the local current density is significantly reduced, so that damage to the electrodes and the insulator surfaces is minimized. The test results indicate that electron bombardment on the electrodes and the insulator surfaces is minimized. The test results indicate that electron bombardment on the electrodes is four orders of magnitude less than that of a spark-gap switch for the same switching power. Indeed, a few thousand shots with peak current exceeding a mega-ampere and with hold-off voltage up to 20 kV have been conducted without showing measurable damage to the electrodes and insulators.

Choi, Sang H.↗

Improving Surface Strength of Insulating Tiles

Procedure for improving tile resistance to impact damage described in new report on tile densification. Developed for Space Shuttle reusable surface insulations, procedure has potential application when space restrictions necessitate thin layers of insulation with low thermal conductivity. Examples are advanced heat engines, such as adiabatic diesel and automotive gas turbine, as well as fast-heating high-temperature ovens.

Holt, J. W.↗

Evaluation of three thermal protection systems in a hypersonic high-heating-rate environment induced by an elevon deflected 30 deg

Three thermal protection systems proposed for a hypersonic research airplane were subjected to high heating rates in the Langley 8 foot, high temperature structures tunnel. Metallic heat sink (Lockalloy), reusable surface insulation, and insulator-ablator materials were each tested under similar conditions. The specimens were tested for a 10 second exposure on the windward side of an elevon deflected 30 deg. The metallic heat sink panel exhibited no damage; whereas the reusable surface insulation tiles were debonded from the panel and the insulator-ablator panel eroded through its thickness, thus exposing the aluminum structure to the Mach 7 environment.

Taylor, A. H.↗

Sizing an emergency venting system for a cryogenic dewar

If the vacuum vessel that insulates a cryogenic dewar for a spaceborne experiment prior to launch is damaged, air will leak into the vacuum insulation space. As the sudden heat load causes the pressure to rise in the dewar, a safety disk in the emergency vent line will burst at the design pressure differential to allow vaporized cryogenic fluid to escape. The emergency vent line should be sized such that sufficient gaseous cryogen will be vented to keep the pressure inside the dewar below the design limit. On the other hand, the line should not be so large as to impose an unnecessary heat load on the dewar filled with cryogenic fluid. A vent-line computer program was generated to compute the maximum flow rate allowed for a proposed vent-line system. Parametric studies have been carried out for different burst disk pressure differentials, liquid cryogen ullage, and vent-line sizes.

Liu, C. K.↗

Ballistic Performance of Porous-Ceramic, Thermal Protection Systems to 9 km/s

Porous-ceramic, thermal protection systems are used heavily in current reentry vehicles like the Orbiter, and they are currently being proposed for the next generation of US manned spacecraft, Orion. These materials insulate the structural components and sensitive components of a spacecraft against the intense thermal environments of atmospheric reentry. These materials are also highly exposed to solid particle space environment hazards. This paper discusses recent impact testing up to 9.65 km/s on ceramic tiles similar to those used on the Orbiter. These tiles are a porous-ceramic insulator of nominally 8 lb/ft(exp 3) alumina-fiber-enhanced-thermal-barrier (AETB8) coated with a damage-resistant, toughened-unipiece-fibrous-insulation/reaction-cured-glass layer (TUFI/RCG).

Miller, Joshua E.↗