Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “initial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Highly loaded multi-stage fan drive turbine - performance of initial seven configurations

Experimental results of a three-stage highly loaded fan drive turbine test program are presented. A plain blade turbine, a tandem blade turbine, and a tangentially leaned stator turbine were designed for the same velocity diagram and flowpath. Seven combinations of bladerows were tested to evaluate stage performances and effects of the tandem blading and leaned stator. The plain blade turbine design point total-to-total efficiency was 0.886. The turbine with the stage three leaned stator had the same efficiency with an improved exit swirl profile and increased hub reaction. Two-stage group tests showed that the two-stage turbine with tandem stage two stator had an efficiency of 0.880 compared to 0.868 for the plain blade two-stage turbine.

Wolfmeyer, G. W.↗

Radio frequency performance of DSS 14 64-meter antenna at X-band using an improved subreflector

The performance of the Deep Space Station (DSS) 14 64-meter antenna X-band gain determined using the X- and K-band Radar feedcone is discussed. Tests prior to, and following the installation of an improved subreflector, proved the unit largely (if not totally) restored initial performance levels at that station. The X-band peak gain with the subreflector is +17.8dBi(area efficiency of 47.3 percent); an increase of +0.47 dB due to the unit installation. The test further showed a significant shift in the axial focus required (function of elevation angle) which, if not implemented operationally, will cause a serious degradation. An historical summary of all documented X-band gain measurements at DSS 14 is included and reviewed. The initial performance is traced through various major configuration changes such as the installation of the X-band dual hybrid mode horn within the operational XRO feedcone. Finally, based on the summary and recent data, a peak X-band antenna gain of +72.1 dBi (area efficiency of 50.8 percent) is projected for the operational feedcone.

Freiley, A. J.↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

SARDA HITL #6 Simulation: System Performance Analysis (Initial Results)

This presentation discusses the results of the 6th human-in-the-loop simulation of the Spot and Runway Departure Advisor (SARDA). SARDA is a research prototype decision support tool for both Air Traffic Control Tower controllers and airlines ramp controllers to assit in controlling surface traffic of a busy airport. Data was collected during the human-in-the-loop simulations of SARDA for ramp operatoins at Charlotte International Airport (Oct-Nov 2014). The performance results include taxi time, taxi delay, total delay, and runway usage.

surface management↗

Barrier reinforcement for enhanced perovskite solar cell stability under reverse bias

Stability of perovskite solar cells (PSCs) under light, heat, humidity and their combinations have been notably improved recently. However, PSCs have poor reverse-bias stability that limits their real-world application. Here we report a systematic study on the degradation mechanisms of p-i-n structure PSCs under reverse bias. The oxidation of iodide by injected holes at the cathode side initialize the reverse-bias-induced degradation, then the generated neutral iodine oxidizes metal electrode such as copper, followed by drift of Cu+ into perovskites and its reduction by injected electrons, resulting in localized metallic filaments and thus device breakdown. A reinforced barrier with combined lithium fluoride, tin oxide and indium tin oxide at the cathode side reduces device dark current and avoids the corrosion of Cu0. It dramatically increases breakdown voltage to above -20 V and improved the T90 lifetime of PSCs to ~1,000 h under -1.6 V. The modified minimodule also maintained over 90% of its initial performance after 720 h of shadow tests.

degradation mechanisms↗

The CLAS12 Ring Imaging Cherenkov Detector

A ring imaging Cherenkov (RICH) detector has been installed in the CLAS12 spectrometer at Jefferson Laboratory (JLab) to provide kaon identification in the momentum range between 3 GeV/c and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors, and highly segmented photon detectors. We report here on the design, construction, and initial performance of the RICH during the commissioning of the detector and the first physics data taking period

PID detectors↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Description and initial operating performance of the Langley 6-inch expansion tube using heated helium driver gas

A general description of the Langley 6-inch expansion tube is presented along with discussion of the basic components, internal resistance heater, arc-discharge assemblies, instrumentation, and operating procedure. Preliminary results using unheated and resistance-heated helium as the driver gas are presented. The driver-gas pressure ranged from approximately 17 to 59 MPa and its temperature ranged from 300 to 510 K. Interface velocities of approximately 3.8 to 6.7 km/sec were generated between the test gas and the acceleration gas using air as the test gas and helium as the acceleration gas. Test flow quality and comparison of measured and predicted expansion-tube flow quantities are discussed.

Moore, J. A.↗

In-flight performance of the IUE

A report on the initial performance of the IUE satellite, launched in January, 1978, is given. Attention is given to optical performance, camera performance, background corrections, photometric performance, and data reduction. Samples of high-dispersion and low-dispersion spectra are shown. A remaining problem of proper separation of high dispersion orders in data reduction is discussed.

Boggess, A.↗

Investigation of heat transfer in zirconium potassium perchlorate at low temperature: A study of the failure mechanism of the NASA standard initiator

The objective of this work was to study the reasons for the failure of pyrotechnic initiators at very low temperatures (10 to 100 K). A two-dimensional model of the NASA standard initiator was constructed to model heat transfer from the electrically heated stainless steel bridgewire to the zirconium potassium perchlorate explosive charge and the alumina charge cup. Temperature dependent properties were used in the model to simulate initiator performance over a wide range of initial temperatures (10 to 500 K). A search of the thermophysical property data base showed that pure alumina has a very high thermal conductivity at low temperatures. It had been assumed to act as a thermal insulator in all previous analyses. Rapid heat transfer from the bridgewire to the alumina at low initial temperatures was shown to cause failure of the initiators if the wire did not also make good contact with the zirconium potassium perchlorate charge. The mode is able to reproduce the results of the tests that had been conducted to investigate the cause for failure. It also provides an explanation for previously puzzling results and suggests simple design changes that will increase reliability at very low initial temperatures.

Varghese, Philip L.↗

Convertor Development for Dynamic Radioisotope Power Systems

Dynamic power conversion technologies are being developed for future space science and exploration missions by NASA’s Radioisotope Power Systems (RPS) Program, in collaboration with the U.S. Department of Energy (DOE). The Dynamic Radioisotope Power Systems (DRPS) Project is working to mature dynamic power convertors and controllers for infusion into a potential future flight generators.1,2 Maturation of power conversion technologies is being executed by the DRPS Project and the Thermal Energy Conversion Branch, located at NASA’s Glenn Research Center (GRC), and includes convertor technology development contracts and in-house controller development. The convertor technology development contracts consist of three contractors tasked to design, fabricate, and complete performance testing before the units are delivered to GRC for independent assessment. All contractors have completed convertor designs and are fabricating convertors to enable performance testing, while one has demonstrated initial performance of their design. The contractors also have provided generator conceptual designs, which utilize their respective convertor technologies being developed.

Dynamic↗

Photoactivated p-Doping of Organic Interlayer Enables Efficient Perovskite/Silicon Tandem Solar Cells

Solution-processed organic semiconductor layers on rough surfaces tend to vary widely in thickness, significantly hindering charge extraction in relevant optoelectronic devices. Herein, we report the photoactivated p-doping of hole-transporting material (HTM) to enhance hole extraction for (textured) perovskite/silicon tandem solar cells, making the device performance less sensitive to the variation of hole transport layer thickness. We used the ionic compound 4-isopropyl-4'-methyldiphenyliodonium tetrakis(penta-fluorophenyl-borate) (DPI-TPFB) as a p-type dopant in poly(triaryl amine) (PTAA), which we used as the HTM. We observed that light soaking DPI-TPFB-doped PTAA shows approximately 22 times higher conductivity compared with an undoped PTAA film, which translated into an improved fill factor (FF) for tandem solar cells. Our tandem solar cells achieved an ~80% FF and 27.8% efficiency and operated at their maximum power point for 200 h without loss of performance, in addition to retaining ~83% of initial performance over a month of operation in an outdoor environment.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,S↗

Performance of lightweight nickel electrodes

The NASA Lewis Research Center is currently developing nickel electrodes for nickel-hydrogen (Ni-H2) batteries. These electrodes are lighter in weight and have higher energy densities than the heavier state-of-the-art (SOA) sintered nickel electrodes. In the present approach, lightweight materials or plaques are used as conductive supports for the nickel hydroxide active material. These plaques (fiber and felt, nickel plated plastic and graphite) are commercial products that are fabricated into nickel electrodes by electrochemically impregnating them with active material. Evaluation is performed in half cells structured in the bipolar configuration. Initial performance tests include capacity measurements at five discharge levels, C/2, 1.0C 1.37C, 2.0C and 2.74C. The electrodes that pass the initial tests are life cycle tested in a low Earth orbit regime at 80 percent depth of discharge. Different formulations of nickel fiber materials obtained from several manufacturers are currently being tested as possible candidates for nickel electrodes. One particular lightweight fiber mat electrode has accumulated over 3000 cycles to date, with stable capacity and voltage. Life and performance data of this electrode were investigated and presented. Good dimensional stability and active material adherence have been demonstrated in electrodes made from this lightweight plaque.

Britton, Doris L.↗