Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “infusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Technology Infusion Challenges from a Decision Support Perspective

In a restricted science budget environment and increasingly numerous required technology developments, the technology investment decisions within NASA are objectively more and more difficult to make such that the end results are satisfying the technical objectives and all the organizational constraints. Under these conditions it is rationally desirable to build an investment portfolio, which has the highest possible technology infusion rate. Arguably the path to infusion is subject to many influencing factors, but here only the challenges associated with the very initial stages are addressed: defining the needs and the subsequent investment decision-support process. It is conceivable that decision consistency and possibly its quality suffer when the decision-making process has limited or no traceability. This paper presents a structured decision-support framework aiming to provide traceable, auditable, infusion- driven recommendations towards a selection process in which these recommendations are used as reference points in further discussions among stakeholders. In this framework addressing well-defined requirements, different measures of success can be defined based on traceability to specific selection criteria. As a direct result, even by using simplified decision models the likelihood of infusion can be probed and consequently improved.

Adumitroaie, V.↗

Infusion Extractor

Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

Chang-Diaz, Franklin R.↗

Fluid-infused elastomers

The present invention relates to fluid-infused elastomers that outperform their non-infused base elastomer in harsh environmental conditions. These fluid-infused polymers may be used in applications including geothermal technologies where the oil-infused elastomers may be subject to harsh conditions.

Grubelich, Mark C.↗

Continuous Regional Arterial Infusion Therapy for Acute Necrotizing Pancreatitis Due to Mycoplasma pneumoniae Infection in a Child

A case of acute necrotizing pancreatitis due to Mycoplasma pneumoniae infection was treated in an 8-year-old girl. She experienced acute pancreatitis during treatment for M. pneumoniae. Contrast-enhanced computed tomographic scan revealed necrotizing pancreatitis. The computed tomographic severity index was 8 points (grade E). A protease inhibitor, ulinastatin, was provided via intravenous infusion but was ineffective. Continuous regional arterial infusion therapy was provided with gabexate mesilate (FOY-007, a protease inhibitor) and meropenem trihydrate, and the pancreatitis improved. This case suggests that infusion therapy is safe and useful in treating necrotizing pancreatitis in children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a New Subclavian Arterial Infusion Chemotherapy Method for Locally or Recurrent Advanced Breast Cancer Using an Implanted Catheter-Port System After Redistribution of Arterial Tumor Supply

Locally or recurrent advanced breast cancers can receive arterial blood supply from various arteries, such as the internal thoracic artery (ITA), the lateral thoracic artery, and the other small arterial branches originating from the subclavian artery. Failure to catheterize and subsequent formation of collateral arterial blood supply from various arteries are some of the reasons why the response to conventional selective transarterial infusion chemotherapy is limited and variable. To overcome this problem, we developed a new subclavian arterial infusion chemotherapy method using an implanted catheter-port system after redistribution of arterial tumor blood supply by embolizing the ITA. We named this technique ('redistributed subclavian arterial infusion chemotherapy' (RESAIC)). Using RESAIC, patients can be treated on an outpatient basis for extended periods of time. Eleven patients underwent RESAIC, and the complete remission and partial response rate in 10 evaluable patients was 90%: complete remission [CR] n = 4, partial remission n = 4, stable disease n = 1, and not evaluable n = 1. Three of four patients with CR had no distant metastasis, and modified radical mastectomy was performed 1 month after conclusion of RESAIC. The resected specimens showed no residual cancer cells, and pathologically confirmed complete remission was diagnosed in each of these cases. Although temporary grade-3 myelosuppression was seen in three patients who were previously treated by systemic chemotherapy, there was no other drug-induced toxicity or procedure-related complications. RESAIC produced a better response and showed no major complications compared with other studies despite the advanced stage of the cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Capecitabine and Pelvic Radiation in Locally Advanced Rectal Cancer-Is it Equivalent to 5-FU Infusion Plus Leucovorin and Radiotherapy?

Purpose: The aim of this retrospective case-matching study was to compare the treatment outcomes and acute toxicity of preoperative radiotherapy (RT) with capecitabine vs. preoperative RT with intermittent 5-fluorouracil (5-FU) infusion, leucovorin, and mitomycin C in rectal cancer. Methods and Materials: We matched 34 patients who were treated with preoperative concurrent capecitabine and 50 Gy of RT by their clinical T stage (T3 or T4) and the tumor location (<=7 cm or >7 cm from the anal verge) with another 68 patients who were treated with preoperative intermittent 5-FU infusion, leucovorin, mitomycin C, and 50 Gy of RT for a comparison of the pathologic tumor response, local control, distant failure, and survival rates. Results: The pathologic complete response rate was 21% with capecitabine and 18% with 5-FU and leucovorin (p = 0.72). The rate of T downstaging after chemoradiation was 59% for both groups. The rate of sphincter-sparing resection was 38% after capecitabine plus RT and 43% after 5-FU plus RT (p = 0.67). At 3 years, there was no significant difference in the local control rate (93% for capecitabine and 92% for 5-FU and leucovorin), relapse-free rate (74% for capecitabine and 73% for 5-FU and leucovorin), or disease-specific survival rate (86% for capecitabine and 77% for 5-FU and leucovorin). The acute toxicity profile was comparable, with little Grade 3 and 4 toxicity. Conclusions: When administered with concurrent preoperative RT, both capecitabine and intermittent 5-FU infusion with leucovorin modulation provided comparable pathologic tumor response, local control, relapse-free survival, and disease-specific survival rates in rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytical model for drag reduction on liquid-infused structured non-wetting surfaces

Liquid-infused structured non-wetting surfaces provide alternating no-slip and partial slip boundary conditions to the fluid flow, resulting in reduced friction at the interface. In this paper, an analytical model is developed for the evaluation of effective slip and, in turn, friction factor and drag reduction on liquid-infused structured non-wetting surfaces. By considering the entire range of anisotropy and heterogeneity of the surface structures as well as the full range of partial slip offered by the infusion liquid, the present model eliminates empirical fitting or correlations that are inherent in previous studies. Based on the effective slip length, drag reduction and skin friction coefficient values for Newtonian flow between two infinite parallel plates and flow in round tubes are presented. Extension of Moody charts for non-wetting surfaces and design maps of surface meso/micro/nano texturing for achieving desired drag reduction are presented for a broad range of engineering applications. The paper further presents independent validation of the model across experimental and computational data from the literature and brings together several previous studies in a unified manner.

36 MATERIALS SCIENCE↗

Observing and preventing rubidium runaway in a direct-infusion xenon-spin hyperpolarizer optimized for high-resolution hyper-CEST (chemical exchange saturation transfer using hyperpolarized nuclei) NMR

Xenon is well known to undergo host-guest interactions with proteins and synthetic molecules. As xenon can also be hyperpolarized by spin exchange optical pumping, allowing the investigation of highly dilute systems, it makes an ideal nuclear magnetic resonance probe for such host molecules. The utility of xenon as a probe can be further improved using Chemical Exchange Saturation Transfer using hyperpolarized nuclei (Hyper-CEST), but for highly accurate experiments requires a polarizer and xenon infusion system optimized for such measurements. We present the design of a hyperpolarizer and xenon infusion system specifically designed to meet the requirements of Hyper-CEST measurements. One key element of this design is preventing rubidium runaway, a chain reaction induced by laser heating that prevents efficient utilization of high photon densities. Using thermocouples positioned along the pumping cell we identify the sources of heating and conditions for rubidium runaway to occur. We then demonstrate the effectiveness of actively cooling the optical cell to prevent rubidium runaway in a compact setup. This results in a 2–3-fold higher polarization than without cooling, allowing us to achieve a polarization of 25% at continuous flow rates of 9 ml/min of {sup 129}Xe. The simplicity of this design also allows it to be retrofitted to many existing polarizers. Combined with a direction infusion system that reduces shot-to-shot noise down to 0.56% we have captured Hyper-CEST spectra in unprecedented detail, allowing us to completely resolve peaks separated by just 1.62 ppm. Due to its high polarization and excellent stability, our design allows the comparison of underlying theories of host-guest systems with experiment at low concentrations, something extremely difficult with previous polarizers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heterogeneous responses of human limbs to infused adrenergic agonists: a gravitational effect?

Unlike quadrupeds, the legs of humans are regularly exposed to elevated pressures relative to the arms. We hypothesized that this "dependent hypertension" would be associated with altered adrenergic responsiveness. Isoproterenol (0.75-24 ng x 100 ml limb volume-1 x min-1) and phenylephrine (0.025-0.8 microg x 100 ml limb volume-1 x min-1) were infused incrementally in the brachial and femoral arteries of 12 normal volunteers; changes in limb blood flow were quantified by using strain-gauge plethysmography. Compared with the forearm, baseline calf vascular resistance was greater (38.8 +/- 2.5 vs. 26.9 +/- 2.0 mmHg x 100 ml x min x ml-1; P < 0.001) and maximal conductance was lower (46.1 +/- 11.9 vs. 59.4 +/- 13.4 ml x ml-1 x min-1 x mmHg-1; P < 0.03). Vascular conductance did not differ between the two limbs during isoproterenol infusions, whereas decreases in vascular conductance were greater in the calf than the forearm during phenylephrine infusions (P < 0.001). With responses normalized to maximal conductance, the half-maximal response for phenylephrine was significantly less for the calf than the forearm (P < 0.001), whereas the half-maximal response for isoproterenol did not differ between limbs. We conclude that alpha1- but not beta-adrenergic-receptor responsiveness in human limbs is nonuniform. The relatively greater response to alpha1-adrenergic-receptor stimulation in the calf may represent an adaptive mechanism that limits blood pooling and capillary filtration in the legs during standing.

Clinical Trial↗

Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 Degree-Sign C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 Degree-Sign C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Simple and Flexible Infusion Platform for Automated Native Mass Spectrometry Analysis

High throughput native mass spectrometry analysis of proteins and protein complexes has been enabled by recent development of infusion and liquid chromatography (LC) systems, which often include complete LC pumps without fully utilizing their gradient flows. We demonstrated a lower-cost infusion cart for native mass spectrometry applications using a single isocratic solvent pump that can operate at both nano- and high-flow configurations (0.05-150 $μ$L/min) for both infusion and online buffer exchange experiments. In conclusion, the platform is controlled via open-source software and can potentially be expanded for customized experimental designs, offering a lower cost alternative to laboratories with limited budgets and/or needs in student training.

47 OTHER INSTRUMENTATION↗

Guiding light via slippery liquid-infused porous surfaces

Slippery liquid-infused porous surfaces (SLIPSs) have been explored for many applications, taking advantage of their highly non-wetting property. In this work, we explore the SLIPS as a cladding material for waveguiding. SLIPSs are prepared by infusing perfluoropolyether oil to hydrophobized nanoporous surfaces of silicon. Power loss and transmission efficiency of an HeNe laser (1.82 mW and 632.8 nm) with varying incident angles were measured through microchannels consisting of the SLIPSs as cladding layers (noil = 1.30) and water (nwater = 1.33) as a core, compared to other cladding types including a planar silicon surface and the nanoporous surfaces in hydrophilic (Wenzel state) and hydrophobic (Cassie–Baxter state) conditions with no oil infused. Agreeing with Snell's law, a total internal reflection occurs at the incident angle as high as 14° for the SLIPSs. The waveguide loss at 14° is only 1.8 dB/cm for the SLIPSs, while those for planar silicon, hydrophilic nanoporous, and hydrophobic nanoporous surfaces are 5.9, 7.4, and 4.9 dB/cm, respectively. The power transmission efficiency of the SLIPSs is independent of the porosity because the surfaces are fully covered with the oil layer, whereas those of hydrophilic and hydrophobic nanoporous surfaces, whose pores are filled with water and air, respectively, depend on the porosity. The significantly lower power loss and the insensitivity to the surface porosity are advantages of the SLIPSs over the other surfaces and can benefit in waveguiding applications such as optofluidics.

Asawa, Kaustubh (ORCID:0000000197142555)↗

SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GE Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.

60 APPLIED LIFE SCIENCES↗

In vivo evaluation of an adaptive resuscitation controller using whole blood and crystalloid infusates for hemorrhagic shock

Introduction Hemorrhage remains the leading cause of preventable death on the battlefield. The most effective means to increase survivability is early hemorrhage control and fluid resuscitation. Unfortunately, fluid resuscitation requires constant adjustments to ensure casualty is properly managed, which is often not feasible in the pre-hospital setting. In this study, we showed how an adaptive closed-loop controller for hemorrhage resuscitation can be used to automate hemodynamic management using a swine hemorrhagic shock injury model. Methods The adaptive resuscitation controller (ARC) was previously developed to track pressure–volume responsiveness in real time and adjust its infusion rate to reach the target mean arterial pressure (MAP). Swine while maintained under a surgical plane of anesthesia and analgesia underwent a splenectomy, followed by two hemorrhage and resuscitation events. For the first resuscitation event, hemorrhage was induced to reduce the MAP to 35 mmHg until arterial lactate reached 4 mmol/L. The ARC system then infused whole blood (WB) to reach the target MAP and maintained the subject using crystalloids for 120 min. For the second resuscitation event, the subjects were hemorrhaged again but resuscitated using only crystalloid infusion to reach the target MAP and 120-min maintenance. Results The ARC was effective at WB resuscitation, reaching the target MAP in 2.0 ± 1.0 min. The median performance error was 1.1% ± 4.6%, and target overshoot was 14.4% ± 7.0% of the target MAP. The ARC maintained all animals throughout the 120 min maintenance period. For the second crystalloid-based resuscitation, ARC required a longer time to reach the target MAP, at an average rise time of 4.3 ± 4.0 min. However, target overshoot was reduced to 8.4% ± 7.3% of the target MAP. Much higher flow rates were required to maintain the target MAP during the second resuscitation event than during the first resuscitation event. Discussion The ARC was able to rapidly reach and maintain the target MAP effectively. However, this sometimes required large volumes of fluid as the ARC’s only goal was to reach the target MAP. Further clinical insight is needed regarding the preferred aggression level to achieve the target MAP. In conclusion, the ARC was successful in its programmed objective of reaching and maintaining the target MAP for extended periods of time in vivo , a critical next step toward improving hemorrhage treatment in the pre-hospital environment.

Snider, Eric J.↗

Fluid infusion system

Development of a fluid infusion system was undertaken in response to a need for an intravenous infusion device operable under conditions of zero-g. The initial design approach, pursued in the construction of the first breadboard instrument, was to regulate the pressure of the motive gas to produce a similar regulated pressure in the infusion liquid. This scheme was not workable because of the varying bag contact area, and a major design iteration was made. A floating sensor plate in the center of the bag pressure plate was made to operate a pressure regulator built into the bellows assembly, effectively making liquid pressure the directly controlled variable. Other design changes were made as experience was gained with the breadboard. Extensive performance tests were conducted on both the breadboard and the prototype device; accurately regulated flows from 6 m1/min to 100 m1/min were achieved. All system functions were shown to operate satisfactorily.

Hammond, J. C.↗

Glucose Infusion into Exercising Dogs after Confinement: Rectal and Active Muscle Temperatures

Intravenous glucose infusion into ambulatory dogs results in attenuation of exercise-induced increase of both rectal and thigh muscle temperatures. That glucose (Glu) infusion attenuates excessive increase in body temperature from restricted activity during confinement deconditioning. Intravenous glucose infusion attenuates the rise in exercise core temperature in deconditioned dogs by a yet undefined mechanism.

Greenleaf, J. E.↗

Supercritical Fluid Infusion of Iron Additives in Polymeric Matrices

The objective of this project was the experimentation to measure preparation of iron nanophases within polymeric matrices via supercritical fluid infusion of iron precursors followed by thermal reduction. Another objective was to determine if supercritical CO2 could infuse into the polymer. The experiment is described along with the materials, and the supercritical fluid infusion and cure procedures. X-ray photoelectron spectra and transmission electron micrographs were obtained. The results are summarized in charts, and tables.

Nazem, Negin↗

The NASA Software Research Infusion Initiative: Successful Technology Transfer for Software Assurance

New processes, methods and tools are constantly appearing in the field of software engineering. Many of these augur great potential in improving software development processes, resulting in higher quality software with greater levels of assurance. However, there are a number of obstacles that impede their infusion into software development practices. These are the recurring obstacles common to many forms of research. Practitioners cannot readily identify the emerging techniques that may most benefit them, and cannot afford to risk time and effort in evaluating and experimenting with them while there is still uncertainty about whether they will have payoff in this particular context. Similarly, researchers cannot readily identify those practitioners whose problems would be amenable to their techniques and lack the feedback from practical applications necessary to help them to evolve their techniques to make them more likely to be successful. This paper describes an ongoing effort conducted by a software engineering research infusion team, and the NASA Research Infusion Initiative, established by NASA s Software Engineering Initiative, to overcome these obstacles.

Hinchey, Michael G.↗