At least 73 records · Page 4

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY IN THE ANALYSIS OF PLUTONIUM CONTENT OF FAST CRITICAL ASSEMBLY FUEL DISPOSITION

Outline • Fast Critical Assembly (FCA) Plutonium Fuel Disposition • Brief campaign overview • Savannah River National Laboratory • Analytical capabilities and instrumentation • Typical FCA sample analysis process • Plutonium analysis by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS) • Method description/development • Instrumentation • Data/control charts

Bonilla, Henry J. [Savannah River National Laborat↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Langmuir Probe Distortions and Probe Compensation in an Inductively Coupled Plasma

In many RF discharges, Langmuir probe measurements are usually made against a background of sinusoidal (and not so sinusoidal) fluctuations in the plasma parameters such as the plasma potential (Vp), the electron number density (ne), and the electron temperature (Te). The compensation of sinusoidal fluctuations in Vp has been extensively studied and is relatively well understood. Less attention has been paid to the possible distortions introduced by small fluctuations in plasma density and/or plasma temperature, which may arise in the sheath and pre-sheath regions of RF discharges. Here, we present the results of a model simulation of probe characteristics subject to fluctuations in both Vp and ne. The modeling of probe distortion due to possible fluctuations in Te is less straightforward. A comparison is presented of calculations with experimental measurements using a compensated and uncompensated Langmuir probe in an inductively coupled GEC reference cell plasma, operating on Ar and Ar/CF4 mixtures. The plasma parameters determined from the compensated probe characteristics are compared to previous measurements of others made in similar discharges, and to our own measurements of the average electron density derived from electrical impedance measurements.

Ji, J. S.↗

On-line Inductively Coupled Plasma Mass Spectrometry Reveals Material Degradation Dynamics of Au and Cu Catalysts during Electrochemical CO 2 Reduction

A significant challenge in commercializing electrochemical CO 2 reduction (CO 2 R) is achieving catalyst durability. Here, in this study, online inductively coupled mass spectrometry (ICP–MS) was used to investigate catalyst degradation via nanoparticle detachment and/or dissolution into metal ions under CO 2 R operating conditions in 0.1 M KHCO 3 . We developed an experimental framework with ex situ characterization to validate the online ICP–MS method for in situ evaluation of degradation from metal foils. By varying the applied potential and microenvironment (CO 2 vs N 2 -saturated electrolyte), we gained insights into the degradation of Au and Cu foils under CO 2 R and hydrogen evolution reaction (HER) conditions. While both Au and Cu foils were observed to be stable to dissolution in these regimes, degradation via nanoparticle detachment from the foil surface at the femtogram scale was observed as a function of reaction conditions, providing new insights into material degradation mechanisms. When applying potential steps at −0.1 and −1.0 V vs the reversible hydrogen electrode (RHE), Au was found to degrade via nanoparticle detachment under CO 2 R operating conditions more than under HER conditions, while Cu was found to degrade via nanoparticle detachment in similar amounts during both reactions. Au lost ∼1.8× more mass and ∼7.5× more nanoparticles than Cu under CO 2 R operating conditions. This study demonstrates the use of online ICP–MS to gain insight into the degradation of Au and Cu, the importance of studying unconventional degradation mechanisms such as nanoparticle detachment, and that online ICP–MS can be further utilized to gain fundamental understanding of catalyst durability for a variety of reaction systems.

Yan, Katherine [Stanford Univ., CA (United States)↗

Inductively Coupled Plasma Etching for Delineation of InAs/GaSb Pixels

We developed 320x256 Complimentary Barrier Infrared (CBIRD) focal plane array (FPA) for long wave infrared (LWIR) imaging application. The FPA layers grown by molecular beam epitaxy (MBE) had 300 periods 1.9 micro m thick absorber. The CBIRD arrays showed the mean dark current density of 2.2 x 10(exp -4) A/cm2, when 128 mV bias voltage was applied. The long wave cut off was observed at 8.8 micrometers at the 50% peak and the maximum quantum efficiency was 54% at 5.6 micrometers. The arrays had 81% fill factor with 97% operability with noise equivalent difference temperature (NE(delta)T) of 18.6 mK and a mean detectivity of D*=1.3 x 10(exp 11) Hz(exp 1/2)/W.

InAs/GaSb↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Gas-phase ion-molecule interactions in a collision reaction cell with triple quadrupole-inductively coupled plasma mass spectrometry: Investigations with N 2 O as the reaction gas

Nitrous oxide (N 2 O) was used as a reaction gas to investigate the gas phase ion-molecule interactions using the Agilent 8900 QQQ-ICP-MS. A multi-element standard containing 45 elements with masses ranging from 9 to 208 u was measured in the presence and absence of N 2 O. The main product ion species observed were oxides and nitrides. Comparison of the N 2 O reaction results with similar measurements conducted with O 2 revealed that N 2 O was more effective at forming oxides in general: the elements Cd and Pb were shown to produce oxides with N 2 O where the reaction did not occur with O 2 . Nitrous oxide was also shown to produce a significant amount of nitride species in a few cases. The general reactivity was shown to be consistent with density functional theory (DFT)-predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels at least 1% of the unreacted ion. Our results show that reaction enthalpy is a reasonable predictor of reactivity with N2O on the timescales of the interactions in non-thermal ICP-MS/MS systems. Our work demonstrates the utility of two relatively new platforms (commercial elemental ICP-MS/MS and EMSL Arrows interface to the NWChem program suite), which allows for the study of a large number of elements within a short period. While DFT with the basis sets utilized here is not the most accurate computational method, it is also not computationally expensive and is shown to be suitable for predicting gas phase reactivity in the QQQ-ICP-MS for the majority of ions studied. Here, the ease and rapidity of data collection and DFT calculations has the potential to be very impactful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Curious Case of Pu + : Insight on 5f Orbital Activity from Inductively Coupled Plasma Tandem Mass Spectrometry (ICP-MS/MS) Reactions

A comprehensive understanding of when and how 5f orbitals participate in complex chemical bonding is important for a variety of applications. The actinides are unique in that they possess 5f orbitals and can access high oxidation states, which make them attractive for use in catalysis. Fundamental studies of actinide–ligand interactions offer a mechanism to examine the activation of the 5f orbitals so that the selectivity of 5f orbitals can be assessed. A previous study examined the reaction of Pu + + CO 2 and determined that the reaction efficiency is restricted by a barrier, namely, promotion from the Pu + ground-state configuration, 5f 6 7s, to a reactive-state configuration, 5f 5 6d 2 . Here, the present study illustrates the benefit of activation of Pu’s 5f orbitals when studying the reaction of Pu + + NO. In this reaction, PuO + forms in an exothermic, barrierless process. The 5f orbitals can and do participate in forming a linear intermediate, [N-Pu-O] + , and this drives the exothermic reaction. Understanding the conditions under which 5f orbitals are active in chemical bonding is the key to exploiting the actinides’ selective catalytic capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗