Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “in situ monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

In situ Monitoring of Lanthanide Reactions with Oxide Species via Combined Absorption Spectroscopy and Electrochemical Methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

absorption spectroscopy↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form various insoluble oxide and oxychloride species with uranium and fission products. This work demonstrates real-time concentration monitoring of two trivalent lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. A combination of high-temperature absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled in the range of 0.001 M to 0.5 M by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides (LnOCl) or mixtures of oxychlorides and oxides (Ln2O3). However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Estimated reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed to within ~10% of the results found from absorption spectroscopy monitoring. This demonstrates that simultaneous electrochemical testing complements and expands the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with cyclic voltammetry (CV). Reaction rates and extent of Pr3+ removal from solution as monitored by CV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simultaneous in situ Optical Monitoring Techniques during Crystal Growth of ZnSe by Physical Vapor Transport

ZnSe crystals grown in sealed ampoules by the physical vapor transport method were monitored in situ using three techniques, simultaneously. A Michelson interferometer was set-up to observe the growth rate and surface morphological evolution. An interference pattern (interferogram) is formed by the interaction between the reflection of a HeNe laser (632.8 nm wavelength) off the crystal-vapor interface and a reference beam from the same laser. Preliminary results indicate that the rate of growth/thermal-etching can be calculated using analog data acquisition and simple fringe counting techniques. Gross surface features may also be observed using a digital frame grabber and fringe analysis software. The second in situ technique uses optical absorption to determine the partial pressures of the vapor species. The Se2 and Zn vapor species present in the sealed ampoule absorb light at characteristic wavelengths. The optical absorption is determined by monitoring the light intensity difference between the sample and reference beams. The Se2 Partial pressure profile along the length of the ampoule was estimated from the vibronic absorption peaks at 340.5, 350.8, 361.3 and 379.2 nm using the Beer's law constants established in the calibration runs of pure Se. Finally, because the high temperature crystal growth furnace contains windows, in situ visual observation of the growing crystal is also possible. The use of these techniques not only permits in situ investigation of high temperature vapor growth of semiconductors, but also offers the potential for real time feed back on the growing crystal and allows the possibility of actively controlling the growth process.

Su, C.- H.↗

Towards Qualification and Certification of Laser Powder Bed Fusion Ti-6Al-4V with In-Situ Process Monitoring and Automated Defect Detection

Qualification and certification of laser powder bed fusion (LPBF) parts are two challenges that must be answered to ensure suitability for critical applications. In-situ monitoring using high frame rate thermal and conventional optical imaging sensors is applied to the LPBF build process. Currently, the large volume of data from such sensors becomes untenable for manual inspection in production environments. This presentation serves to address this in-situ monitoring deficiency in two ways. First, a framework for managing data streams from LPBF process monitoring sensors is described. Second, two candidate image analysis techniques are presented: one is a set of heuristics that are easily interpretable, and the other is an uninterpretable convolutional neural network. These strategies are compared in terms of performance, computational expense, and speed. These methodologies represent platforms for connecting processing conditions to process modeling efforts aligned with the qualification and certification mission for LPBF Ti-6Al-4V components.

Qualification↗

Description and field test of an in situ coliform monitoring system

A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

Grana, D. C.↗

In situ health monitoring of piezoelectric sensors

An in situ health monitoring apparatus may include an exciter circuit that applies a pulse to a piezoelectric transducer and a data processing system that determines the piezoelectric transducer's dynamic response to the first pulse. The dynamic response can be used to evaluate the operating range, health, and as-mounted resonance frequency of the transducer, as well as the strength of a coupling between the transducer and a structure and the health of the structure.

Jensen, Scott L.↗

Continuous optical in-situ pH monitoring during early hydration of cementitious materials

A luminescent sensor technique for pH analyses has been tested in cementitious media. The optical sensors monitor in-situ pH every 5 s during early hydration reactions over a period of 100 h from initial fluid up to consolidated stage. The pH development was analysed in calcium aluminate, calcium sulfoaluminate and OPC/slag cements up to a pH level of 13.3 and directly correlated with the heat of hydration. Thus tracing the dissolution and formation processes of solid phases via pH sensor monitoring is possible. This measurement technique enables the recording of continuous and highly reproducible pH data sets from slurries, pastes, and hardening materials leading to new vistas for individual (trans)formation pathways of solids, hydration and consolidation reactions in high alkaline cementitious systems.

36 MATERIALS SCIENCE↗

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

In-Situ Process Monitoring, Synchronization, and Mapping Laser Powder Bed Fusion Builds of Ti6Al4V

The use of in-situ process monitoring is of interest to lower the cost of inspection for the qualification of laser powder bed fusion (LPBF) parts. Precise monitoring of the LPBF-AM build process constitutes a multi-scale and multi-discipline task. There are several significant challenges to the in-situ approach: the synchronization of sensor signals to process steps, the physical interpretation and classification of sensor signals, managing very large datasets, and comparing the inputs with the observed monitoring signals. At NASA Langley Research Center, a configurable architecture additive testbed has been developed to monitor the build process with synchronized sensors. The philosophy and method adopted for the synchronization of the cameras with laser power & position Ti-6Al-4V LPBF are described. The synchronized in-situ monitoring signals are compared with ex-situ nondestructive inspection and optical microscopy observations. Such comparisons permit a better understanding of how the sequential process actions of LPBF-AM can affect build quality.

Laser Powder Bed Fusion↗

An innovative digital image correlation technique for in-situ process monitoring of composite structures in large scale additive manufacturing

As additive manufacturing (AM) continues to develop and become a standardized manufacturing method, there will be a continued need to provide in-situ monitoring during the manufacturing of polymer composite printed components. Thermal residual stress is a primary cause of failures such as interlayer disbonds or delamination, micro cracking, and dimensional instability, which can occur during or after the build. Here, we report a novel digital image correlation (DIC) adaptation to monitor thermal residual stresses during the entire print process for large-scale AM. In this work, DIC has been investigated (a) by the natural speckle produced by the polymer surface for correlation, (b) to monitor AM build, and (c) to evaluate the effect of thermal residual stress on warpage of the printed component. The natural speckle pattern of the AM material resulted in a respectable 3.57% error compared to the traditional painted speckle pattern of 3.05% error. DIC measured a 190% increase in vertical displacement at the edge of the wall compared to the center, indicating warpage during AM. This work is a step towards a non-intrusive residual stress measuring technique using DIC for large-scale AM.

36 MATERIALS SCIENCE↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Review of in situ process monitoring for metal hybrid directed energy deposition

Hybrid manufacturing, or the combination of additive and subtractive manufacturing within a single build volume is transforming the way products are being fabricated. Additive manufacturing confers unprecedented freedom of design and reduced material usage while enabling serial customization. Subtractive manufacturing provides superior surface finish and improved dimensional accuracies. Interwoven, these two digital manufacturing paradigms are enabling the rapid manufacturing of complex, highly accurate, and customized geometries in a diversity of high-performance alloys. In situ monitoring, heavily relied upon in either additive or subtractive, becomes even more crucial with the interplay of the two processes in a single combined build sequence. Moreover, challenges that do not exist in either process alone can now have a dramatic impact on final part quality: (1) a large amount of heat is generated during additive manufacturing deposition, which is primarily dissipated into the machine tooling and impacts accuracy by deforming the material and causing misaligned machining; (2) microstructure, mechanical properties, and residual stresses are the result of the complex thermal histories generated by additive manufacturing and can impact subsequent cutting performance. This comprehensive review considers previous research in monitoring and providing closed-loop control in both additive and subtractive manufacturing separately and then considers the implications of the effectiveness of these monitoring techniques when additive and subtractive processes are integrated together.

36 MATERIALS SCIENCE↗