Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “impedance estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Acoustic Impedance Inversions for Offshore CO 2 Storage: South Georgia Embayment, United States

This study builds and expands on previous CO 2 storage resource assessment studies of the southeastern offshore Atlantic margin by providing a detailed evaluation on how rock porosities and permeabilities are distributed across the Upper Cretaceous strata restricted to the South Georgia Embayment (SGE). Using legacy industry two-dimensional seismic reflection and well data, this assessment is the first application of multiple seismic inversion techniques in this area. This workflow provides a reliable and repeatable model-based inversion which gives an improved image to discriminate lithology and predict porosity. The workflow is applicable to future CO 2 storage resource assessment studies elsewhere. The inversion results indicate that distinct porosity and permeability regimes are present and distributed in the Upper Cretaceous strata within the SGE. The impedance and porosity relationships show well-founded and reliable correlation. These relationships reveal low impedance coincident to the high porosity intervals which are proposed as potential reservoir intervals for CO 2 storage. In addition, the result shows that the Upper Cretaceous strata have two main potential reservoirs in the lower part. These are overlain by a thick impermeable interval, mostly shale, which has high impedance, low porosity, and low permeability and extends within the SGE. This result is in agreement with a previous study that also proposed two significant storage reservoirs for CO 2 in the Upper Cretaceous strata. Since porosity distribution is estimated using multiple methods, it follows the trends of seismic signature and structures of the Upper Cretaceous strata. The extracted values of porosity, ranging from 15 to 36%, and permeability, ranging from 1 to 100 mD, are close to the measured values from the well core data at the Upper Cretaceous strata interval.

54 ENVIRONMENTAL SCIENCES↗

Impedance‐matching model‐in‐the‐loop simulation

Abstract Impedance matching is a novel approach to executing model‐in‐the‐loop (MIL) simulations. The concept, key features, and sample applications of this approach have been described in a series of publications. This paper advances theory and implementation for impedance‐matching MIL by: (1) developing a feedback linearization technique for implementing MIL for nonlinear virtual systems, (2) systematically characterizing MIL performance‐stability tradeoffs using three design‐oriented criteria—performance: defined as closeness of the controlled‐actuator impedance to the virtual‐boundary impedance;control effort: low controller response at high frequencies to reduce sensitivity to measurement noise and uncertainties in the actuator model; andstability: pursued using passivity of the controlled actuator system, and (3) assessing, through experimentation, the robustness of two ways to estimate feedback reaction force from the test article. These fundamental advancements to MIL are described using a one‐dimensional configuration consisting of a fluid‐filled cylindrical vessel as the physical test article and a uniaxial hydraulic shake table controlled to imitate different seismic isolation systems at the base of the vessel.

Engineering↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identifying Spectral Descriptors for Protonation in BaZr 0.8 Y 0.2 O 3-x with Electron Energy Loss Spectroscopy

Hydrogen economy is of paramount importance in the global transition to a sustainable, clean energy source that contributes to decarbonization efforts. In particular, the proton conducting proton ceramic fuel cells (PCFCs) play a crucial role in promoting hydrogen energy technology [1-5]. In a PCFC, the electrolyte is typically a solid oxide material that enables proton transport and can operate at temperatures lower than those of traditional oxygen ion conducting fuel cells [6]. The reduced operating temperature of PCFCs contributes to their durability, scalability, and efficiency [7,8]. BaZr 0.8 Y 0.2 O 3-x (BZY) is a promising proton conducting solid oxide electrolyte [9,10]. The emphasis on proton conductivity entails the importance of understanding proton content in the system. However, previous studies have largely relied on bulk techniques such as electrochemical impedance spectroscopy [7,11], Karl-Fischer titration [12,13], and thermogravimetric analysis [14] to obtain proton concentration. This is due to the small atomic size and light mass of hydrogen species making direct detection challenging. Bulk methods may be useful in estimating the proton content; however, it overlooks possible proton concentration gradient or segregation that may occur across or within a nanoparticle, especially when proton incorporation occurs nonuniformly through steam exposure on powder samples. In this paper, BZY is protonated at an estimated 0.15 mol of protons via steam exposure. Electron energy loss spectroscopy (EELS) with nanoscale spatial resolution is explored to identify proxy signals for proton detection using a JEOL ARM300 microscope operated at 300 kV with a Gatan GIF Continuum detector.

08 HYDROGEN↗

A Method of Moments Wide Band Adaptive Rational Interpolation Method for High-Quality Factor Resonant Cavities

A new adaptive rational interpolation method is proposed to obtain the wideband frequency response of a resonant cavity simulated with the method of moments (MoM). This interpolation method uses both the Loewner matrix to construct a rational expression for the solution vector of MoM’s matrix system and an error estimator generated by the solution vectors and their derivatives. This error estimator is implemented in the adaptive procedure to gain a minimum set of frequencies and solution vectors required in the interpolation. The resulting set of frequencies and solution vectors is applied to interpolate other system variables, such as shielding effectiveness and input impedance. Here numerical results of a slotted cylindrical cavity supporting high-quality factor resonances are presented, showing that the new rational interpolation method is accurate and efficient in interpolating the complicated resonant response of the solution vector functions.

42 ENGINEERING↗

A Sensitive Electrochemical Cholinesterase-Inhibiting Biosensor for Organophosphorus Pesticides Based on Ti 3 C 2 TX MXene Quantum Dots

Organophosphorus pesticides (OPs) pose significant environmental and health risks due to their widespread use and toxicity, primarily by inhibiting acetylcholinesterase. Traditional detection methods are often slow and costly, highlighting the urgent need for advanced, sensitive, and accessible technologies. This study developed a highly sensitive electrochemical cholinesterase-inhibiting biosensor for OP pesticides, utilizing Ti 3 C 2 T x MXene Quantum Dots (MQDs), which was synthesized via a hydrothermal method. The biosensor’s performance was characterized using electrochemical impedance spectroscopy, differential pulse voltammetry (DPV), and cyclic voltammetry. DPV proved to be the optimal technique, exhibiting an ultralow detection limit of 1 × 10 −17 M and a wide linear range (10 −14 –10 −8 M) for chlorpyrifos (a model OP) with an estimated inhibition constant of 62 nM. The biosensor demonstrated high selectivity for OPs (chlorpyrifos, acephate, glyphosate) over a non-target pyrethroid (permethrin), confirmed by distinct electrochemical signatures and compared to in vitro cholinergic activity assays in bean beetle homogenates. The enhanced performance is attributed to the high surface-to-volume ratio, quantum confinement effects, and superior conductivity of the MQDs, as well as the robust enzyme immobilization facilitated by glutaraldehyde cross-linking and a chitosan matrix. This work presents a promising platform for rapid, sensitive, and selective detection of OP pesticides, with potential applications in environmental monitoring and public health protection.

Chemistry↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de↗

Isothermal Microcalorimetric Analysis of Li/CF x Battery Discharge

Lithium/carbon monofluoride (Li/CF x ) batteries generate substantial amounts of heat during discharge in part due to the large deviation of the loaded voltage from the measured and thermodynamically predicted open circuit voltage. Here, in this study, we further analyze this system by estimating the equilibrium voltage (V eq ) and its temperature dependence (dV eq /dT) over the entire discharge range. Based on these results, the ohmic and entropic heat contributions to the overall heat flow are calculated from experimental data. The ohmic heat flow is consistent with an electrochemical impedance spectroscopy model and electrode density measurements, indicating decreasing porosity of the electrode during discharge. Entropic heating increases during discharge as the cell reaction becomes increasingly entropically unfavorable. The total energy dissipated by the cell (electrical and thermal) remains similar over the entire discharge, evidence for a two-phase reaction with a constant, and rate-independent, ΔG rxn of about -465 kJ mol -1 . However, near the end of discharge (>90% DOD), ΔG rxn changes significantly indicating possible secondary reactions.

25 ENERGY STORAGE↗

Oxygen vacancy migration and impact on high voltage DC polarization in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3

Electrical polarization and defect transport are examined in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3 , an attractive capacitor material for high power electronics. Oxygen vacancies are suggested to be the majority charge carrier at or below 250°C with a grain conduction hopping activation energy of 0.97 eV and 0.92 eV for thermally stimulated depolarization current (TSDC) and impedance spectroscopy measurements, respectively. At higher temperature, thermally generated electronic conduction with an activation energy of 1.6 eV is dominant. Significant oxygen vacancy concentration is indicated (up to ~1%) due to cation vacancy formation (i.e., acceptor defects) from observed Bi (and likely Zn) volatility. Oxygen vacancy diffusivity is estimated to be 10 -12.8 cm 2 /s at 250°C. Low diffusivity and high activation energies are indicative of significant defect interactions. Dipolar oxygen vacancy defects are also indicated, with an activation energy of 0.59 eV from TSDC measurements. In conclusion, the large oxygen vacancy content leads to a short lifetime during high voltage (30 kV/cm), high temperature (250°C) direct current (DC) electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simplified calculation of the area specific impedance for solid-state battery design

Simplified algebraic area specific impedance (ASI) correlations have been developed for solid-state composite battery electrodes made of a single ion conducting electrolyte, conductive additive, and intercalation active material. Two ASI expressions were developed, one for short times ( i.e. , pulsed power operation) and another for the pseudo steady state operation (i.e., sustained discharge for energy estimation). A full electrochemical model based on porous electrode theory was developed to examine the accuracy of the simplified ASI expressions. The simplified expressions agree favorably with full model results over a wide range of parameters (i.e. , electrode thicknesses, electrolyte conductivities, solid-state diffusion coefficients, specific surface areas, etc.) and conditions (i.e. , C-rates, states of charge, and pulse times). Under most conditions, the error between the full model and the correlations is well below 7 %. Higher errors were observed for the pseudo steady state expression at high/ low states of charge where the assumption of uniform reaction distributions loses validity. Here, the short time ASI has higher error at low states of charge due to the nonlinearity of the open circuit voltage equation, which is assumed linear in the formulation of the simplified algebraic expression.

25 ENERGY STORAGE↗

Electrochemical Corrosion of SIMFUEL: Effects of dissolved H2 and noble metal particles

This report describes the results from electrochemical corrosion tests that were conducted using simulated spent fuel (SIMFUEL) materials comprised of UO2 and surrogate fission products. Two SIMFUEL compositions were tested to quantify the effect of noble metal inclusions and dissolved H2 on the UO2 dissolution rate. One material consisted of UO2 with added lanthanide oxides (UO2 N) and the other consisted of UO2 with added lanthanide oxides and noble metals (UO2-H) at concentrations to simulate high burnup fuel. The electrochemical corrosion tests on the SIMFUEL materials were conducted in aqueous electrolyte solutions (pH 10) that were either saturated with air or purged with a H2/Ar gas mixture to maintain a constant dissolved H2 concentration. The results from electrochemical corrosion tests on SIMFUEL can be applied to qualitatively understand and also quantify the separate effects of water chemistry and fuel composition on the degradation behavior of the UO2 matrix. Open circuit potential (OCP) measurements on a SIMFUEL material of known composition (i.e., known fraction of NMPs at the fuel surface) immersed in a known solution chemistry (i.e., pH, Eh, [O2], [H2]) at known temperature provide qualitative insight into the degradation behavior of the UO2 matrix. If the OCP is above the threshold potential at which the oxidative dissolution of U(IV) to U(VI) occurs, the SNF is expected to degrade by oxidative processes under the experimental conditions. The net currents that are measured during potentiostatic tests, during which the surface potential of the SIMFUEL material is fixed by a potentiostat, can be used to quantify the UO2 degradation rate and optimize the rate constant values used in the Fuel Matrix Degradation Model (FMDM) for half reactions that occur on the SNF surface. Specifically, electrochemical measurements enable the estimation of the total anodic current at ECORR–which is the surface potential at which the total anodic and total cathodic currents are equal–so that the rate constant values for key reactions can be calculated. The open circuit potential measurements, potentiostatic tests, surface property measurements (scanning electron microscopy images and electrochemical impedence spectroscopy plots), and solution elemental composition analyses are being performed to update and optimize the FMDM. A case study is presented herein to show how electrochemical corrosion test results and accompanying characterization results for the UO2 N material in air-saturated solution can be used to validate the SNF surface reaction module of the FMDM. Future electrochemical tests will be conducted to provide quantitative information on the effects of NM content (burnup), H2 concentration, water chemistry, temperature, and galvanic couples with cladding and EBS alloys on UO2 degradation that can be used to improve the accuracy and functionality of the FMDM.

Thomas, Sara↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Relationship Between Microstructure and Performance in Gadolinium-Doped Ceria Infiltrated Ni/YSZ Symmetric Cells

Infiltration of mixed ionic/electronic conducting (MIEC) nanocatalysts into the anodes of solid oxide fuel cells (SOFCs) allow the hydrogen oxidation reaction (HOR) to occur at double-phase boundaries (DPBs), rather than being confined only to the triple phase boundaries (TPBs). In this research, we use a combination of cross-sectional scanning electron microscopy (SEM), three-dimensional (3-D) reconstruction, and electrochemical methods to characterize both baseline and gadolinium-doped ceria (GDC)-infiltrated symmetric cells, with the goal of establishing a comparison between the density of electrochemically active sites in uninfiltrated and GDC-infiltrated cells. Here, electrochemical impedance spectroscopy (EIS) and distribution of relaxation times (DRT) analysis showed GDC infiltration decreased the overall polarization of the anode by a factor of 8.78 X, and decreased the resistance associated with the reactions at the TPBs/DPBs by a factor of over 21 X. By quantifying expected GDC deposition morphology in the Ni/YSZ anode it is estimated that reactions occur in the baseline cell up to 84 nm from the active TPB lines.

36 MATERIALS SCIENCE↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Expert and operator perspectives on barriers to energy efficiency in data centers

Abstract It was last estimated in 2016 that data centers (DCs) comprise approximately 2% of total US electricity consumption. However, this estimate is currently being updated to account for the massive increase in computing needs due to streaming, cryptocurrency, and artificial intelligence (AI). To prevent energy consumption that tracks with increasing computing needs, it is imperative we identify energy efficiency strategies and investments beyond the low-hanging fruit solutions. In a two-phased research approach, we ask: What non-technical barriers still impede energy efficiency (EE) practices and investments in the data center sector, and what can be done to overcome these barriers? In particular, we are focused on social and organizational barriers to EE. In Phase I, we performed a literature review and found that technical solutions are abundant in the literature, but fail to address the top-down cultural shifts that need to take place in order to adapt new energy efficiency strategies. In Phase II, reported here, we interviewed 16 data center operators/experts to ground-truth our literature findings. Our interview protocols focus on three aspects of DC decision-making: procurement practices, metrics and monitoring, and perceived barriers to energy efficiency. We find that vendors are the key drivers of procurement decisions, advanced efficiency metrics are facility-specific, and there is convergence in the design of advanced facilities due to the heat density of parallelized infrastructure. Our ultimate goals for our research are to design DC decarbonization policies that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗