Engineering PapersSearch

SEARCH · Engineering Papers

Results for “impact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

192 records · Page 4

Sensitivity Analysis of Numerical Modeling Input Parameters on Wind Turbine Loads in Deterministic Transient Load Cases

Aero-hydro-elastic-servo numerical models used to design and analyze wind turbines are based on thousands of variable input parameters that dictate the inflow, aerodynamic, structural, and control characteristics of the system as well as sea state, hydrodynamic, and mooring characteristics for fixed-bottom and floating offshore wind turbines. Each of these parameters has some level of uncertainty, which can significantly impact the predicted loads. Understanding the uncertainty in the inputs is critical to understanding the uncertainty in the outputs. This work demonstrates a screening technique to identify which parameters ultimate loads are most sensitive to so that more focus can be given to quantifying the possible range of those parameters. This technique has been demonstrated previously for different turbine and load case types and is extended here for a floating offshore wind turbine in design load cases with transient events both in the inflow and operations. Each load case features a deterministic gust, including variations in wind speed, direction, and shear. Load cases are considered with an operating turbine as well as with prescribed fault, startup, and shutdown procedures. The study found that key input parameters with a large impact on loads include the length of the gust, the magnitude of direction change and speed in the gust, the initial wind speed, and the shape of the gust profile.

17 WIND ENERGY

Fingerprinting Uranium Oxides with Electron Energy Loss Spectroscopy Supported by Theoretical Computations

Uranium oxides occur in a variety of phases that differ in crystal structure and uranium oxidation states. Electron energy loss spectroscopy (EELS) is one of the few techniques that has sufficient spatial resolution and sensitivity to electronic structure to distinguish amongst phases at the nanoscale. However, beam-sensitive materials such as uranium oxides are subject to spectral modification due to interactions with the electron beam. Therefore, theory support is essential to reliably exclude the impact of beam damage and generate true reference datasets. Here we use a comparison of theoretical and experimental spectra to probe the impact of beam damage on O K-edge and U N-edge (N6,7 and N4,5) EELS spectra of various single-valent and mixed-valence uranium oxide bulk phases. Using a low-dose experimental set-up, we show that the O K-edge theoretical spectra are in excellent agreement with experiment for both peak positions and relative intensities of respective peaks. In contrast, U N-edge features are less distinguishing due to the partially localized nature of the U 5f orbitals and overlapping multiplet and spin–orbit coupling effects. This work demonstrates that O K-edge EELS is sufficiently diagnostic to distinguish a wide range of uranium oxides and that the experimental approach used here minimizes beam damage and allows valence state discrimination across the U(IV), U(V) and U(VI) series. When combined with imaging modes available in electron mi-croscopy, the work enables detailed investigation and characterization of uranium redox transformations at the nanoscale.

Carbone, Jacopo

Investigating permafrost carbon dynamics in Alaska with artificial intelligence

Abstract Positive feedbacks between permafrost degradation and the release of soil carbon into the atmosphere impact land–atmosphere interactions, disrupt the global carbon cycle, and accelerate climate change. The widespread distribution of thawing permafrost is causing a cascade of geophysical and biochemical disturbances with global impacts. Currently, few earth system models account for permafrost carbon feedback (PCF) mechanisms. This research study integrates artificial intelligence (AI) tools and information derived from field-scale surveys across the tundra and boreal landscapes in Alaska. We identify and interpret the permafrost carbon cycling links and feedback sensitivities with GeoCryoAI, a hybridized multimodal deep learning (DL) architecture of stacked convolutionally layered, memory-encoded recurrent neural networks (NN). This framework integratesin-situmeasurements and flux tower observations for teacher forcing and model training. Preliminary experiments to quantify, validate, and forecast permafrost degradation and carbon efflux across Alaska demonstrate the fidelity of this data-driven architecture. More specifically, GeoCryoAI logs the ecological memory and effectively learns covariate dynamics while demonstrating an aptitude to simulate and forecast PCF dynamics—active layer thickness (ALT), carbon dioxide flux (CO 2 ), and methane flux (CH 4 )—with high precision and minimal loss (i.e. ALT RMSE : 1.327 cm [1969–2022]; CO 2 RMSE : 0.697µmolCO 2 m −2 s −1 [2003–2021]; CH 4 RMSE : 0.715 nmolCH 4 m −2 s −1 [2011–2022]). ALT variability is a sensitive harbinger of change, a unique signal characterizing the PCF, and our model is the first characterization of these dynamics across space and time.

Environmental Sciences & Ecology

Identifying microstructures susceptible to pulverization in commercially irradiated high burnup UO2 under LOCA conditions

High burnup fuel fragmentation (HBFF) has been a concern in the nuclear industry for many years. When UO2 reaches and exceeds pellet average burnups around 55 GWd/tU, microstructural changes in the fuel pellet begin to occur that render the pellet susceptible to fine fragmentation under loss-of-coolant accident (LOCA) conditions. During a LOCA event, the cladding balloons and bursts, potentially releasing part of these fine fuel fragments into the reactor pressure vessel. This process is known as fuel fragmentation, relocation, and dispersal (FFRD). Presently, the US nuclear industry is developing a safety basis for FFRD with the goal of increasing burnups and pressurized water reactor cycle lengths. Increased cycle lengths would push the burnup limits of the fuel rods past the known threshold for HBFF susceptibility. In this work, the microstructural impact on HBFF was investigated by comparing the microstructures of as-irradiated rod segments to their post-LOCA tested counterparts. This investigation found that varied operational histories result in different microstructural evolutions across the pellet radius, which impacts the fragmentation behavior and radial location of the fragmentation. It is noted that regions with a high bubble density and a high density of grain boundaries fragment under LOCA-relevant conditions. In addition to the fragmentation that has been previously reported at the periphery of the fuel, fragmentation was also noted in the dark zone toward the fuel center. Analysis of the power histories of the fuel samples suggests that the dark zone forms in the central regions of the pellet between temperatures of approximately 740 and 960 °C.

McKinney, Casey [ORNL] (ORCID:0000000335383614)

Financial Analysis of the Smallmouth Bass Flows implemented at the Glen Canyon Dam during 2025

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specifies criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases.

Ploussard, Quentin [Argonne National Laboratory (A

Maximizing dynamic range and performance of anatase TiO 2 ECRAM through structure and programming

Here, in this study, we investigate the structure-dependent modulation characteristics of all-solid-state three-terminal electrochemical random-access memory (ECRAM) based on an anatase Li x TiO 2 channel. By directly comparing “asymmetric” and “symmetric” ECRAM device architectures, we reveal significant insight into the impact of a non-zero gate-drain open-circuit voltage and its influence on voltage vs. current-controlled gating. We also explore the impact of potentiation/depression write parameters on the symmetry, linearity, and dynamic range of the device response. Together, initial results from optimizing structure and programming approaches yielded unprecedented G max /G min ratios of >1,000 for ECRAM and hundreds of tunable memory states with excellent linearity and symmetry. Simulations based on these ECRAM devices further illustrate the promise of this analog memory technology, achieving near 2% classification error in the MNIST digit recognition benchmark for a range of training parameters compared to a theoretical best of 1.66% and outperforming other device models extracted from the literature.

AIHWKit

Development of Post-Consumer Textile Waste Degradation Protocol and Related Downstream Transformations: Cooperative Research and Development (Final Report)

Tereform, Inc. (Tereform) is developing molecular deconstruction processes to transform waste materials into chemical building blocks. During the CRADA, Tereform deconstructed real-world post-consumer substrates into chemical monomers, validated their performance on laboratory scales, demonstrated feasibility of the degradation products in downstream transformations, and successfully scaled the reaction to kilogram-scale. These results were used to develop and refine technoeconomic analysis and lifecycle assessments to evaluate the economic feasibility and environmental impacts of the process.

36 MATERIALS SCIENCE

Boron Coordination in Multicomponent Glasses: Analytical Models and Machine Learning With Uncertainty

Borosilicate glasses are extensively used in a variety of applications from kitchenware to nuclear waste immobilization due to the strong network formed by the Si-O-B bond that makes it resistant to chemical corrosion and gives it a low thermal expansion. Boron, however, exists in both trigonal BO3 and tetrahedral BO4 bonds in glass systems, which impacts the chemical durability and thermal resistance of the glass, amongst other properties. Boron coordination (N4), or the ratio of the amount of BO4 to BO3 within a glass, may aid in predicting these properties but is difficult to derive without experimental data due to the complexity of impacts from varied glass compositions and processing factors. For this reason, compositional models have been developed to predict boron coordination, but the models typically include a limited number of glass components. To help fill this gap in the models, in this work, a diverse multicomponent glass dataset of 809 glasses is compiled from a literature search, and then a number of analytical and machine learning (ML) models are trained on the dataset. Previously developed modified Bernstein and modified Du Stebbins analytical models were fitted to update parameters with the new dataset. Then, partially Bayesian neural networks, Gaussian process regressor, and heteroskedastic deterministic neural networks were evaluated. The ML models examined all have different strategies to overcome the potential for overfitting as a result of a limited training dataset, and return results that account for model uncertainty, which can be valuable for understanding model reliability. For the first time, cooling rate is introduced as an input parameter for ML models, showing consistent improvements in performance and solidifying the importance of including parameters outside of composition alone for N4 prediction. The machine learning models examined here show promise in accurate predictions of boron coordination in borosilicate glasses, all achieving R2 values of 0.91.

boron coordination

Cosmic neutrino decoupling and its observable imprints: insights from entropic-dual transport

Abstract Very different processes characterize the decoupling of neutrinos to form the cosmic neutrino background (CνB) and the much later decoupling of photons from thermal equilibrium to form the cosmic microwave background (CMB). The CνB emerges from the fuzzy, energy-dependent neutrinosphere and encodes the physics operating in the early universe in the temperature rangeT∼ 10 MeV toT∼ 10 keV. This is the epoch where beyond Standard Model (BSM) physics, especially in the neutrino sector, may be influential in setting the light element abundances, the necessarily distorted fossil neutrino energy spectra, and other light particle energy density contributions. Here we use techniques honed in extensive CMB studies to analyze the CνB as calculated in detailed neutrino energy transport and nuclear reaction simulations of the protracted weak decoupling and primordial nucleosynthesis epochs. Our moment method, relative entropy, and differential visibility approach can leverage future high precision CMB and light element primordial abundance measurements to provide new insights into the CνB and any BSM physics it encodes. We demonstrate that the evolution of the energy spectrum of the CνB throughout the weak decoupling epoch is accurately captured in the Standard Model by only three parameters per species, a non-trivial conclusion given the deviation from thermal equilibrium and the impact of the decrease of electron-positron pairs. Furthermore, we can interpret each of the three parameters as physical characteristics of a non-equilibrium system. Though the treatment presented here makes some simplifying assumptions including ignoring neutrino flavor oscillations, the success of our compact description within the Standard Model motivates its use also in BSM scenarios. We further demonstrate how observations of primordial light element abundances can be used to place constraints on the CνB energy spectrum, deriving response functions that can be applied for general deviations from a thermal spectrum. Combined with the description of those deviations that we develop here, our methods provide a convenient and powerful framework to constrain the impact of BSM physics on the CνB.

Astronomy & Astrophysics

The Role of Nuclear Data Sensitivities in Prompt α-Eigenvalue Predictions of Delayed Critical Benchmarks

Alpha (α) eigenvalues, which describe the logarithmic time derivative of the neutron population in a multiplying system, are integral to time-dependent behavior and diagnostic applications. However, uncertainties in the evaluated nuclear data can significantly impact the accuracy of transport simulations for such quantities. This work explores the use of machine learning models to predict two key outputs, α-eigenvalues and keff bias, using input features derived from α-eigenvalue sensitivities to nuclear data. The criticality safety benchmark models used in this study come from the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Three models, random forest, XGBoost, and NGBoost, are trained on both energy-resolved and energy-summed α sensitivities. For the α-eigenvalue bias prediction, NGBoost achieved the highest R 2 (0.9476) using energy-resolved features, while XGBoost performed best using summed sensitivities. In contrast, when predicting the keff bias, all the models showed moderate predictive capability (best R 2 ≈ 0.72), as the mapping from the static α-sensitivities to the static keff bias was less direct. SHAP (SHapley Additive exPlanations) analysis was used to interpret the model predictions. Across both prediction tasks, the features associated with neutron capture [H-1 (n, γ)], uranium scattering reactions (such as 235 U elastic/inelastic), and actinide capture/fission reactions (such as 239 Pu and 234 U) were consistently identified as the most impactful. This highlights the key role of specific nuclear reactions and energy ranges in shaping both time-dependent and steady-state criticality behavior. These results demonstrated that α-sensitivities, despite being computed for time-dependent metrics, can provide valuable insights for predicting both α-eigenvalues and the keff bias. Moreover, machine learning models offer a promising pathway for uncovering important nuclear data dependencies and guiding future data evaluation efforts.

Nuclear data

Feedstock Choices for Advancing the Bioeconomy in the US and Policy Implications

Biomass feedstocks will be critical for scaling up the bioeconomy in the United States to meet multiple demands for biofuels, sustainable aviation fuel, bioproducts, and biochemicals. There is a wide range of choices of feedstocks, including a variety of dedicated energy crops and crop residues. There are substantial differences in the yields, costs of production, and carbon intensity of these feedstocks and for each feedstock across locations. These feedstocks also differ in the trade-offs they offer among multiple environmental impacts. We discuss the economic factors that will influence the production of these feedstocks and the implications of alternative biofuel and low-carbon policies for the mix of feedstocks that will be incentivized.

Khanna, Madhu (ORCID:0000000349944451)

U.S. ESCO Industry Report: Industry Size and Recent Market Trends, 2022- 2024

The latest edition of the U.S. Energy Service Company (ESCO) Industry Report by Lawrence Berkeley National Laboratory (LBNL) finds that the U.S. ESCO industry continues to show strong growth. The report draws from ESCO industry reported revenue data for the 2022-2024 period, detailing the current size and characteristics of the U.S. ESCO industry. Following 20 years of ESCO industry reports, the 2024 report explores significant revenue trends across market segments, geographic regions, ESCO size, financing structures, and business activities. New analysis in this report outlines customer priorities and non-energy benefit drivers of Energy Savings Performance Contract projects, adjusted revenue analysis detailing the impacts of inflation on industry growth, and project challenges by market segment.

Chelminski, Kathryn

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Synthetic Tuning of Exciton–Phonon Coupling in Janus WS 2(1-x) Se 2x Monolayers Revealed by Resonant Raman Excitation Spectroscopy for Optoelectronic Applications

Janus monolayers, such as WSSe, have broken out-of-plane symmetry and an intrinsic dipole moment, impacting exciton transport, lifetime, and phonon interactions while imbuing piezoelectric, photocatalytic, and Rashba spin-splitting properties to transition metal dichalcogenides (TMDs). The new properties of this atomically thin material can be used for optoelectronic device applications. As TMDs are converted into Janus monolayers, e.g., top selenization of WS2 to WSSe, the bandgap and structure smoothly evolve, impacting not only the formation of excitons but also their complex interactions with different phonon modes. Resonant Raman excitation profiles (REPs) are uniquely well-suited to reveal both excitonic transitions and exciton–phonon coupling. Here, the resonant REPs of $A^{'}_{1}$ WS 2 and A 1 WSSe modes are measured to understand the strength of their coupling with the A, B, and C excitonic bands of a WS2 monolayer throughout its stepwise transformation into Janus WSSe by pulsed laser deposition (PLD) of energetic selenium species. In situ Raman spectroscopy during deposition is used to controllably prepare stable intermediate Janus structures, WS 2(1-x) Se 2x (0 ≤ x ≤ 0.5), for ex situ measurement of their resonant REPs. As x increases, REPs reveal not only pronounced excitonic bands that gradually shift toward lower photon energies but also strong, mode-selective exciton–phonon coupling. First-principles resonant Raman simulations independently predict this spectral behavior and are shown capable of matching the spectrally broadened, experimentally observed REP profiles in this model system, indicating their strong predictive capability for future experiments. The combination of controlled synthesis, REP characterization, and predictive theory employed here demonstrates a powerful pathway to understand and ultimately tune exciton–phonon interactions for future quantum optical devices.

Janus monolayers

Linking Community‐Climate Disequilibrium to Ecosystem Function

Turnover in species composition often lags behind the pace of climate change, resulting in mismatches between climate and communities. However, the impact of these community‐climate disequilibria on ecosystem functions is rarely considered, and current methods for measuring disequilibria assume that species ranges were, until recently, in equilibrium with climate. Here, in this work, we develop a simple theoretical model to address both of these problems by linking community‐climate disequilibrium with ecosystem functioning. We show how disequilibrium can impair functioning in the near‐term even when climate change is expected to enhance functioning in the long‐term. Responses are most likely to change over time in communities where turnover is slow, the impact of disequilibrium counteracts the direct effects of climate on ecosystem function, and pre‐existing disequilibrium is large. These findings emphasise the importance of precise and unbiased estimates of community‐climate disequilibria for improving ecological forecasts. By fitting our model to time series of both climate and ecosystem function from a metacommunity simulation, we show the potential for community‐climate disequilibrium to be inferred without direct knowledge about species' distributions or climatic tolerances. We end by outlining a research agenda to apply dynamic disequilibrium concepts and test novel hypotheses across diverse ecosystems.

climate change

Advancing Building Performance: Field Results of Thin-Glass Triple-Pane Window Demonstrations

To meet California and the nation's ambitious energy targets, energy use in the building sector must drop dramatically. Windows continue to be the lowest thermally performing envelope system in the nation's buildings, resulting in poor overall envelope performance and potential impacts to human health and comfort. Current best practice new window performance is typically met by double-pane low-solar-gain glazing. Thin-glass triple-pane windows are a highly promising next step forward in performance and have been deployed in two California multi-family sites to quantify field performance and building energy savings. The technology assessed offers the performance benefits of traditional triple-pane but with little increase in weight or cost, enabling incremental costs competitive with alternative energy reduction solutions for the building envelope. This paper covers a detailed investigation into the demonstration project and measured performance benefits of the windows after a full year of data collection.

Hart, Robert

Role of ion acoustic instability in magnetic reconnection

We report on a first-principles numerical study of magnetic reconnection in plasmas with different initial ion-to-electron temperature ratios. In cases where this ratio is significantly below unity, we observe intense wave activity in the diffusion region, driven by the ion-acoustic instability. Our analysis shows that the dominant macroscopic effect of this instability is to drive substantial ion heating. In contrast to earlier studies reporting significant anomalous resistivity, we find that anomalous contributions due to the ion-acoustic instability are minimal. These results shed light on the dynamical impact of this instability on reconnection processes, offering new insights into the fundamental physics governing collisionless reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY