Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-Ray Imaging System

The Model 60007A InnerView Real-time X-ray Imaging System, produced by National Imaging Systems, a division of FlouroScan Imaging Systems, Inc. (formerly HealthMate, Inc.), Northbrook, IL, is a third generation spinoff from x-ray astronomy technology. Goddard Space Flight Center developed the original technology into the Lixiscope, a small, portable, minimal radiation x-ray instrument that could be used at the scene of an accident. FlouroScan Imaging Systems, Inc., adapted this technology to develop the FlouroScan, a low-intensity, x-ray system that could be used without the lead aprons, film badges and lead-lined walls that conventional systems require. The InnerView is a spinoff of non-destructive testing and product inspection.

Source record↗

Noise analysis for near field 3-D FM-CW radar imaging systems

Near field radar imaging systems are used for several applications including concealed weapon detection in airports and other high-security venues. Despite the near-field operation, phase noise and thermal noise can limit the performance in several ways including reduction in system sensitivity and reduction of image dynamic range. In this paper, the effects of thermal noise, phase noise, and processing gain are analyzed in the context of a near field 3-D FM-CW imaging radar as might be used for concealed weapon detection. In addition to traditional frequency domain analysis, a time-domain simulation is employed to graphically demonstrate the effect of these noise sources on a fast-chirping FM-CW system.

microwave imaging↗

Depth-resolved ballistic imaging in a low-depth-of-field optical Kerr gated imaging system

We demonstrate depth-resolved imaging in a ballistic imaging system, in which a heterodyned femtosecond optical Kerr gate is introduced to extract useful imaging photons for detecting an object hidden in turbid media and a compound lens is proposed to ensure both the depth-resolved imaging capability and the long working distance. Two objects of about 15-μm widths hidden in a polystyrene-sphere suspension have been successfully imaged with approximately 600-μm depth resolution. Modulation-transfer-function curves with the object in and away from the object plane have also been measured to confirm the depth-resolved imaging capability of the low-depth-of-field (low-DOF) ballistic imaging system. This imaging approach shows potential for application in research of the internal structure of highly scattering fuel spray.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimating optical imaging system performance for space applications

The critical system elements of an optical imaging system are identified and a method for an initial assessment of system performance is presented. A generalized imaging system is defined. A system analysis is considered, followed by a component analysis. An example of the method is given using a film imaging system.

Sinclair, K. F.↗

SU-E-J-47: Comparison of Online Image Registrations of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac Imaging Systems

Purpose To compare online image registrations of TrueBeam cone-beam CT (CBCT) and BrainLab ExacTrac imaging systems. Methods Tests were performed on a Varian TrueBeam STx linear accelerator (Version 2.0), which is integrated with a BrainLab ExacTrac imaging system (Version 6.0.5). The study was focused on comparing the online image registrations for translational shifts. A Rando head phantom was placed on treatment couch and immobilized with a BrainLab mask. The phantom was shifted by moving the couch translationally for 8 mm with a step size of 1 mm, in vertical, longitudinal, and lateral directions, respectively. At each location, the phantom was imaged with CBCT and ExacTrac x-ray. CBCT images were registered with TrueBeam and ExacTrac online registration algorithms, respectively. And ExacTrac x-ray image registrations were performed. Shifts calculated from different registrations were compared with nominal couch shifts. Results The averages and ranges of absolute differences between couch shifts and calculated phantom shifts obtained from ExacTrac x-ray registration, ExacTrac CBCT registration with default window, ExaxTrac CBCT registration with adjusted window (bone), Truebeam CBCT registration with bone window, and Truebeam CBCT registration with soft tissue window, were: 0.07 (0.02–0.14), 0.14 (0.01–0.35), 0.12 (0.02–0.28), 0.09 (0–0.20), and 0.06 (0–0.10) mm, in vertical direction; 0.06 (0.01–0.12), 0.27 (0.07–0.57), 0.23 (0.02–0.48), 0.04 (0–0.10), and 0.08 (0– 0.20) mm, in longitudinal direction; 0.05 (0.01–0.21), 0.35 (0.14–0.80), 0.25 (0.01–0.56), 0.19 (0–0.40), and 0.20 (0–0.40) mm, in lateral direction. Conclusion The shifts calculated from ExacTrac x-ray and TrueBeam CBCT registrations were close to each other (the differences between were less than 0.40 mm in any direction), and had better agreements with couch shifts than those from ExacTrac CBCT registrations. There were no significant differences between TrueBeam CBCT registrations using different windows. In ExacTrac CBCT registrations, using bone window led to better agreements than using default window.

60 APPLIED LIFE SCIENCES↗

Image reconstruction of shielded mixed-oxide fuel using a dual-particle imaging system

The dual-particle imaging system being developed at the University of Michigan was used at the Joint Research Centre in Ispra, Italy for measurements on samples of special nuclear material. A 1,150-g mixed-oxide (MOX) fuel sample was measured with various shielding configurations to determine how the presence of lead and/or polyethylene shielding degrades the system's ability to localize a source by simultaneous neutron and photon imaging. Three two-hour measurements were taken with the source shielded by an: a) 8-mm lead sheath and 5.1-cm lead bricks, b) 8-mm lead sheath and 6.5-cm polyethylene bricks, and c) 8-mm lead sheath, 5.1-cm lead bricks, and 6.5-cm polyethylene bricks. The 8-mm lead sheath was used in all cases to reduce the measured photon count rate. A “bare” measurement was also made by using only the 8-mm lead sheath, but the unexpected presence of additional sources has rendered the measurement unsuitable for comparison. Here, the resulting images show that the dual-particle imaging system is able to accurately localize the MOX canister in the presence of intervening material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Moving-Article X-Ray Imaging System and Method for 3-D Image Generation

An x-ray imaging system and method for a moving article are provided for an article moved along a linear direction of travel while the article is exposed to non-overlapping x-ray beams. A plurality of parallel linear sensor arrays are disposed in the x-ray beams after they pass through the article. More specifically, a first half of the plurality are disposed in a first of the x-ray beams while a second half of the plurality are disposed in a second of the x-ray beams. Each of the parallel linear sensor arrays is oriented perpendicular to the linear direction of travel. Each of the parallel linear sensor arrays in the first half is matched to a corresponding one of the parallel linear sensor arrays in the second half in terms of an angular position in the first of the x-ray beams and the second of the x-ray beams, respectively.

Fernandez, Kenneth R.↗

A Novel 24 GHz One-Shot, Rapid and Portable Microwave Imaging System

Development of microwave and millimeter wave imaging systems has received significant attention in the past decade. Signals at these frequencies penetrate inside of dielectric materials and have relatively small wavelengths. Thus. imaging systems at these frequencies can produce images of the dielectric and geometrical distributions of objects. Although there are many different approaches for imaging at these frequencies. they each have their respective advantageous and limiting features (hardware. reconstruction algorithms). One method involves electronically scanning a given spatial domain while recording the coherent scattered field distribution from an object. Consequently. different reconstruction or imaging techniques may be used to produce an image (dielectric distribution and geometrical features) of the object. The ability to perform this accurate~v and fast can lead to the development of a rapid imaging system that can be used in the same manner as a video camera. This paper describes the design of such a system. operating at 2-1 GHz. using modulated scatterer technique applied to 30 resonant slots in a prescribed measurement domain.

Ghasr, M. T.↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

Video Imaging System Particularly Suited for Dynamic Gear Inspection

A digital video imaging system that captures the image of a single tooth of interest of a rotating gear is disclosed. The video imaging system detects the complete rotation of the gear and divide that rotation into discrete time intervals so that each tooth of interest of the gear is precisely determined when it is at a desired location that is illuminated in unison with a digital video camera so as to record a single digital image for each tooth. The digital images are available to provide instantaneous analysis of the tooth of interest, or to be stored and later provide images that yield a history that may be used to predict gear failure, such as gear fatigue. The imaging system is completely automated by a controlling program so that it may run for several days acquiring images without supervision from the user.

Broughton, Howard↗

Global Ultraviolet Imaging Processing for the GGS Polar Visible Imaging System (VIS)

The Visible Imaging System (VIS) on Polar spacecraft of the NASA Goddard Space Flight Center was launched into orbit about Earth on February 24, 1996. Since shortly after launch, the Earth Camera subsystem of the VIS has been operated nearly continuously to acquire far ultraviolet, global images of Earth and its northern and southern auroral ovals. The only exceptions to this continuous imaging occurred for approximately 10 days at the times of the Polar spacecraft re-orientation maneuvers in October, 1996 and April, 1997. Since launch, approximately 525,000 images have been acquired with the VIS Earth Camera. The VIS instrument operational health continues to be excellent. Since launch, all systems have operated nominally with all voltages, currents, and temperatures remaining at nominal values. In addition, the sensitivity of the Earth Camera to ultraviolet light has remained constant throughout the operation period. Revised flight software was uploaded to the VIS in order to compensate for the spacecraft wobble. This is accomplished by electronic shuttering of the sensor in synchronization with the 6-second period of the wobble, thus recovering the original spatial resolution obtainable with the VIS Earth Camera. In addition, software patches were uploaded to make the VIS immune to signal dropouts that occur in the sliprings of the despun platform mechanism. These changes have worked very well. The VIS and in particular the VIS Earth Camera is fully operational and will continue to acquire global auroral images as the sun progresses toward solar maximum conditions after the turn of the century.

Frank, L. A.↗

Initial Investigation of the Small Feature Detection Capability of the ORNL Fast Neutron Tomographic Imaging System

A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a version of the Oak Ridge National Laboratory fast neutron tomographic imaging system. Two image quality indicators were examined: (1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder, and (2) a variety of short steels pins embedded radially in the surface of a polyethylene cylinder. Measurements demonstrated detectability of about 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution. Our current simulation code takes only partial consideration of the DT generator neutron production spot size, with neutron production effectively originating at a single point. Simulations showed that features less than 2 mm should be detectable with an improved generator. Our current ING-27 DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor at present. Generators with spot sizes as small as 1 mm are commercially available. Higher-power, small–spot size associated particle generators are at the prototype stage and are expected to be commercially available soon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Multi-Edge Slant Target for Unlocalized MTF Measurement of Airborne Imaging System Payloads

Calibration of imaging instruments is a critical step in effectively characterizing imaging data. A comprehensive characterization of an imaging system provides valuable insight into the overall uncertainties in the results derived from the raw data collected. The Scientifically Calibrated In-Flight Imagery (SCIFLI) team (based at NASA Langley Research Center) has designed, built, tested, and successfully flown the optical payload known as the SCIFLI Airborne Multispectral Imager (SAMI). SAMI is a multispectral imaging payload, complete with sensor configurations for the Ultraviolet-Visible spectrum as well as Near- Infrared, Shortwave Infrared, and Midwave Infrared bands and is fitted with various optical hardware designed to turn, split, and focus light beams to the respective in-band sensors. Radiometric calibrations are performed for SAMI such that the accuracy and uncertainty of thermal and spectral measurements are effectively characterized. However, SAMI does not regularly undergo spatial characterizations to evaluate the performance of the imager at high spatial frequencies. This is essential, as understanding the spatial sensor response of discrete sensors is just as important as the spectral sensor response. The payload currently utilizes a calibration cart for lab testing. Equipped with a modular setup and several radiation sources, it is perfect for performing high-quality radiometric calibrations. This work focuses on using the calibration cart to perform spatial calibrations. A custom designed calibration target is being used to evaluate the optical performance of SAMI. Specifically, the target is designed to measure the Modulation Transfer Function (MTF) of the imager in discrete locations around the focal plane. The results of this characterization will provide insight into the spatial resolution capabilities of the SAMI payload in practice. Future work includes using the results of the study to correct optical imperfections in imagery taken with SAMI.

SAMI↗

Analysis of Fringe Field Formed Inside LDA Measurement Volume Using Compact Two Hololens Imaging Systems

We have designed and fabricated four LDA optical setups consisting of aberration compensated four different compact two hololens imaging systems. We have experimentally investigated and realized a hololens recording geometry which is interferogram of converging spherical wavefront with mutually coherent planar wavefront. Proposed real time monitoring and actual fringe field analysis techniques allow complete characterizations of fringes formed at measurement volume and permit to evaluate beam quality, alignment and fringe uniformity with greater precision. After experimentally analyzing the fringes formed at measurement volume by all four imaging systems, it is found that fringes obtained using compact two hololens imaging systems get improved both qualitatively and quantitatively compared to that obtained using conventional imaging system. Results indicate qualitative improvement of non-uniformity in fringe thickness and micro intensity variations perpendicular to the fringes, and quantitative improvement of 39.25% in overall average normalized standard deviations of fringe width formed by compact two hololens imaging systems compare to that of conventional imaging system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

A High-resolution Multi-wavelength Simultaneous Imaging System with Solar Adaptive Optics

A high-resolution multi-wavelength simultaneous imaging system from visible to near-infrared bands with a solar adaptive optics system, in which seven imaging channels, including the G band (430.5 nm), the Na i line (589 nm), the H α line (656.3 nm), the TiO band (705.7 nm), the Ca ii IR line (854.2 nm), the He i line (1083 nm), and the Fe i line (1565.3 nm), are chosen, is developed to image the solar atmosphere from the photosphere layer to the chromosphere layer. To our knowledge, this is the solar high-resolution imaging system with the widest spectral coverage. This system was demonstrated at the 1 m New Vaccum Solar Telescope and the on-sky high-resolution observational results were acquired. In this paper, we will illustrate the design and performance of the imaging system. The calibration and the data reduction of the system are also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

An Approach to Characterizing Spatial Aspects of Image System Blur

In imaging applications, such as X-ray radiography, the experimental system setup and data capture process introduce system blur and distortion. In images taken with thick scintillators, a spatially varying system blur is observed, requiring a nonstandard approach to blur and distortion estimation and removal. We demonstrate an approach to estimation of local point spread functions using checkerboard radiographs collected at the Naval Research Laboratory and extend that into a map defining the kernel over the camera field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗