Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multi-Site Observational Study to Assess Biomarkers for Susceptibility or Resilience to Chronic Pain: The Acute to Chronic Pain Signatures (A2CPS) Study Protocol

Chronic pain has become a global health problem contributing to years lived with disability and reduced quality of life. Advances in the clinical management of chronic pain have been limited due to incomplete understanding of the multiple risk factors and molecular mechanisms that contribute to the development of chronic pain. The Acute to Chronic Pain Signatures (A2CPS) Program aims to characterize the predictive nature of biomarkers (brain imaging, high-throughput molecular screening techniques, or “omics,” quantitative sensory testing, patient-reported outcome assessments and functional assessments) to identify individuals who will develop chronic pain following surgical intervention. The A2CPS is a multisite observational study investigating biomarkers and collective biosignatures (a combination of several individual biomarkers) that predict susceptibility or resilience to the development of chronic pain following knee arthroplasty and thoracic surgery. This manuscript provides an overview of data collection methods and procedures designed to standardize data collection across multiple clinical sites and institutions. Pain-related biomarkers are evaluated before surgery and up to 3 months after surgery for use as predictors of patient reported outcomes 6 months after surgery. The dataset from this prospective observational study will be available for researchers internal and external to the A2CPS Consortium to advance understanding of the transition from acute to chronic postsurgical pain.

60 APPLIED LIFE SCIENCES↗

Primordial non-Gaussianity from the completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey – I: Catalogue preparation and systematic mitigation

ABSTRACT We investigate the large-scale clustering of the final spectroscopic sample of quasars from the recently completed extended Baryon Oscillation Spectroscopic Survey (eBOSS). The sample contains 343 708 objects in the redshift range 0.8 < z < 2.2 and 72 667 objects with redshifts 2.2 < z < 3.5, covering an effective area of $4699\, {\rm deg}^{2}$. We develop a neural network-based approach to mitigate spurious fluctuations in the density field caused by spatial variations in the quality of the imaging data used to select targets for follow-up spectroscopy. Simulations are used with the same angular and radial distributions as the real data to estimate covariance matrices, perform error analyses, and assess residual systematic uncertainties. We measure the mean density contrast and cross-correlations of the eBOSS quasars against maps of potential sources of imaging systematics to address algorithm effectiveness, finding that the neural network-based approach outperforms standard linear regression. Stellar density is one of the most important sources of spurious fluctuations, and a new template constructed using data from the Gaia spacecraft provides the best match to the observed quasar clustering. The end-product from this work is a new value-added quasar catalogue with the improved weights to correct for non-linear imaging systematic effects, which will be made public. Our quasar catalogue is used to measure the local-type primordial non-Gaussianity in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

Report on the AAPM grand challenge on deep generative modeling for learning medical image statistics

Abstract Background The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. Purpose The goal of this challenge was to promote the development of deep generative models for medical imaging and to emphasize the need for their domain‐relevant assessments via the analysis of relevant image statistics. Methods As part of this Grand Challenge, a common training dataset and an evaluation procedure was developed for benchmarking deep generative models for medical image synthesis. To create the training dataset, an established 3D virtual breast phantom was adapted. The resulting dataset comprised about 108 000 images of size 512 512. For the evaluation of submissions to the Challenge, an ensemble of 10 000 DGM‐generated images from each submission was employed. The evaluation procedure consisted of two stages. In the first stage, a preliminary check for memorization and image quality (via the Fréchet Inception Distance [FID]) was performed. Submissions that passed the first stage were then evaluated for the reproducibility of image statistics corresponding to several feature families including texture, morphology, image moments, fractal statistics, and skeleton statistics. A summary measure in this feature space was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, the four classes in the training data, and also to identify various artifacts. Results Fifty‐eight submissions from 12 unique users were received for this Challenge. Out of these 12 submissions, 9 submissions passed the first stage of evaluation and were eligible for ranking. The top‐ranked submission employed a conditional latent diffusion model, whereas the joint runners‐up employed a generative adversarial network, followed by another network for image superresolution. In general, we observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID‐based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. Conclusions This Grand Challenge highlighted the need for domain‐specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.

Radiology, Nuclear Medicine & Medical Imaging↗

A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging

Abstract Ambient Noise Imaging (ANI) of subsurface structures relies on seismic interferometry of diffuse seismic wavefields. However, the lack of effective methods to quantify and identify highly diffuse waves hampers applications of ANI, particularly in evaluating seismic attenuation and monitoring structural changes with high temporal resolution. Conventional ANI approaches require data normalization, which effectively suppresses the non‐diffuse component with large amplitude but also results in significant loss of amplitude and phase information in the continuous seismic records. In this study, we propose a frequency domain method to quantitatively evaluate the degree of diffuseness of seismic wavefields by analyzing their statistical characteristics of modal amplitudes for stationarity and randomness. Tests on synthetic waveform and field nodal records show that the proposed method can effectively distinguish between diffuse and non‐diffuse waveforms for either single‐ or three‐component data. As an application, we identify a 60‐s‐long diffuse coda of a local M 2.2 earthquake recorded by a dense nodal array on the San Jacinto Fault Zone, and successfully extract high‐quality dispersion curve andQ‐value without performing data normalization. These results are consistent with those obtained by conventional methods that assess the correlation between coherency and the Green's function, and by modeling ballistic waves generated by road traffic. Our proposed method can advance the imaging of subsurface velocity and attenuation structures as well as monitoring temporal changes for scientific studies and engineering applications.

Geochemistry & Geophysics↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Nondestructive Evaluation of Concrete: Elastic Property Imaging Through Full-Waveform Inversion

Concrete is a vital material in construction—especially in the nuclear industry, where it is used in critical structures such as containment vessels. Over time, concrete can degrade due to harsh operational and environmental conditions, necessitating that its elastic properties be accurately evaluated to ensure structural integrity and safety. Traditional nondestructive evaluation methods such as ultrasound-based techniques often rely on simplifying assumptions that may not hold true for concrete. This paper presents an advanced ultrasound-based method that uses elastic full-waveform inversion (EFWI) to create detailed images of concrete’s mechanical properties. By accurately modeling wave behaviors such as scattering and reflection, we aim to overcome the limitations of conventional ultrasonic-based methods. In this work, the imaging problem involved reconstructing the various elastic properties of a heterogenous concrete block with three steel rebars embedded in it. The ultrasonic measurements were synthetically generated from multiple sources and receivers, and the reconstruction process was performed using a gradient-based optimization algorithm. Our approach leveraged EFWI to reconstruct high-resolution images of the pressure wave speed, shear wave speed, and density. Multiple misfit functions—including L2-norm, cross-correlation (CC), and L1-norm—combined with total variation (TV) regularization and parameter constraints using a Sigmoid function—were explored for the reconstruction. The results demonstrated that using the L1-norm misfit function in conjunction with TV regularization and Sigmoid constraints significantly improved the reconstruction quality in comparison to traditional methods. This approach provided clearer images with fewer artifacts and better captured background heterogeneity. Our findings highlight that, when properly designed, EFWI carries great potential for providing comprehensive, more accurate, and more reliable assessments of concrete conditions, as is crucial for the maintenance and safety of nuclear power plant structures.

97 - MATHEMATICS AND COMPUTING↗

Validating deep learning inference during chest X-ray classification for COVID-19 screening

Abstract The new coronavirus unleashed a worldwide pandemic in early 2020, and a fatality rate several times that of the flu. As the number of infections soared, and capabilities for testing lagged behind, chest X-ray (CXR) imaging became more relevant in the early diagnosis and treatment planning for patients with suspected or confirmed COVID-19 infection. In a few weeks, proposed new methods for lung screening using deep learning rapidly appeared, while quality assurance discussions lagged behind. This paper proposes a set of protocols to validate deep learning algorithms, including our ROI Hide-and-Seek protocol, which emphasizes or hides key regions of interest from CXR data. Our protocol allows assessing the classification performance for anomaly detection and its correlation to radiological signatures, an important issue overlooked in several deep learning approaches proposed so far. By running a set of systematic tests over CXR representations using public image datasets, we demonstrate the weaknesses of current techniques and offer perspectives on the advantages and limitations of automated radiography analysis when using heterogeneous data sources.

59 BASIC BIOLOGICAL SCIENCES↗

Nondestructive Modular Leak Detection in 3D Printed 316L Stainless Steel Pipes via Laser Powder Bed Fusion

This research investigates the leak detection features of 316L Stainless Steel pipe structures manufactured via Laser Powder Bed Fusion (LPBF). This work involves the design of a modular sensor system integrating nondestructive evaluation (NDE) methods, including thermal imaging and ultrasonic frequency detection to detect and characterize leaks in components. This aims to improve leak detection sensitivity within medium-pressure gas systems, during continuous operation without halting flow or introducing safety risks. The system could be adaptable for use on unmanned aerial vehicles (UAVs), enabling remote leak detection in active environments. A custom pneumatic system incorporating temperature and pressure sensors was assembled to detect leaks in LPBF-printed 316L SS tee pipes. Experimental results and simulations confirm the system’s effectiveness in leak detection and material evaluation. This research program also integrated a Python-based image recognition platform based on a metallography and optical microscopy to assess the porosity and complement the leak detection data on the printed structures. This allows a detailed analysis of pore distribution and internal leak paths, which could compromise structural integrity, critical for quality control during manufacturing. Findings suggest that the investigated approach holds potential for enhancing leak detection technologies and adapt them for advanced manufactured parts.

36 MATERIALS SCIENCE↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Towards non-contact pollution monitoring in sewers with hyperspectral imaging

Monitoring water quality in sewers is challenging, particularly because state-of-the-art technologies require contact with the raw wastewater. The presence of fat, oil, grease, and solids makes automated grab sampling difficult and causes sensor fouling. To overcome these limitations, non-contact methods based on light reflectance, such as hyperspectral imaging (HSI), are gaining attention. However, HSI has never been tested for raw wastewater. To assess its accuracy for measuring pollution, we developed a laboratory setup and performed targeted experiments with a combination of raw and diluted wastewater, as well as synthetic turbidity stock solutions. We measured seven pollution variables: chemical oxygen demand, turbidity, dissolved organic compounds, ammonium, total nitrogen, phosphate, and sulphates. We used automated pixel selection and partial least squares regression to retrieve pollution information from the hyperspectral images. Our results, based on 144 samples, suggest that HSI can estimate pollution levels with a precision in the range of state-of-the-art absorbance spectrophotometric methods. Additionally, we found that the combination of pixel and wavelength selection, enabled by the hyperspectral data structure, significantly influences the performance of partial least square modelling. Overall, our findings indicate that HSI is a promising technology for non-contact monitoring of water quality in raw wastewater.

54 ENVIRONMENTAL SCIENCES↗

Detecting missing struts in metallic micro-lattices using high speed melt pool thermal monitoring

Metal lattices are an important class of cellular materials that offer great advantages by providing high-strength and lightweight structures as compared to bulk materials. Progress in additive manufacturing techniques has led to increased complexity in design and shape of produced objects and is greatly beneficial for the development of metallic lattice structures. However additive manufacturing of lattices suffers from unpredictable defect creation that can compromise its mechanical integrity. Although post-build inspection techniques can provide quality assurance of the process, accurate assessment can be technically challenging, time consuming and costly. In this work, we investigate the use of high-speed measurements of thermal emission from the melt pool to identify defective individual struts formed with a missing bottom half in an otherwise fully built lattice structure produced with laser powder bed fusion. Surprisingly, results indicate lower photodiode signal, suggesting colder melt pool surface temperature, when printing struts with missing bottom half as compared to nominal struts. Additional thermographic imaging and multi-physics simulations reveal that the low photodiode signal is accompanied by presence of hot spatters carrying heat away from detection and continuous avalanche of powder on the melt pool. Based on these observations, a method was developed to identify defective individual struts with missing bottom half in full built lattices. This prediction approach provides valuable insights about part quality which are important for process qualification and illustrates the utility of melt pool thermal emission monitoring for identifying specific defects introduced by laser powder bed fusion.

36 MATERIALS SCIENCE↗

Crafting pixels in wood: understanding the interplay of technologies and visual perception in wooden photo engraving

This paper delves into the realm of laser engraving of photographs on wooden surfaces and explores the diferences between mathematical and human perception. A comprehensive quality study was conducted to explore the results achieved by 27 diferent realizations. The evaluation process involves both objective analyses and subjective assessments from hundreds of ratings of 60 evaluators, with the aim of unravelling the intricate interplay between technology and visual perception. The study also poses the intriguing question of whether the image most accurately transferred onto a wooden surface is also the most favourably perceived by potential customers and what are their preferences for laser engraved products.

Jurek, Martin [Ostrava, Tech. U.]↗

Seismic Elastic Double-Beam Characterization of Faults and Fractures for CO₂ Storage Site Selection

Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.

02 PETROLEUM↗

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Quantitative phase measurements of human cell nuclei using X-ray ptychography

The human cell nucleus serves as an important organelle holding the genetic blueprint for life. In this work, X-ray ptychography was applied to assess the masses of human cell nuclei using its unique phase shift information. Measurements were carried out at the I13-1 beamline at the Diamond Light Source that has extremely large transverse coherence properties. Furthermore, the ptychographic diffractive imaging approach allowed imaging of large structures that gave quantitative measurements of the phase shift in 2D projections. In this paper a modified ptychography algorithm that improves the quality of the reconstruction for weak scattering samples is presented. The application of this approach to calculate the mass of several human nuclei is also demonstrated.

59 BASIC BIOLOGICAL SCIENCES↗