Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Leveraging interpolation models and error bounds for verifiable scientific machine learning

Effective verification and validation techniques for modern scientific machine learning workflows are challenging to devise. Statistical methods are abundant and easily deployed, but often rely on speculative assumptions about the data and methods involved. Error bounds for classical interpolation techniques can provide mathematically rigorous estimates of accuracy, but often are difficult or impractical to determine computationally. Here, in this work, we present a best-of-both-worlds approach to verifiable scientific machine learning by demonstrating that (1) multiple standard interpolation techniques have informative error bounds that can be computed or estimated efficiently; (2) comparative performance among distinct interpolants can aid in validation goals; (3) deploying interpolation methods on latent spaces generated by deep learning techniques enables some interpretability for black-box models. We present a detailed case study of our approach for predicting lift-drag ratios from airfoil images. Code developed for this work is available in a public Github repository.

97 MATHEMATICS AND COMPUTING↗

Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask

We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.

Qiao, Zhi (ORCID:0000000286285320)↗

Gain scaling for multirate filter banks

Eliminating two trivial degrees of freedom corresponding to the lowpass DC response and the highpass Nyquist response in a two-channel multirate filter bank seems simple enough. Nonetheless, the ISO/IEC JPEG 2000 image coding standard manages to make this mundane task look totally mysterious. We reveal the true meaning behind JPEG 2000's arcane specifications for filter bank normalization and point out how the seemingly trivial matter of gain scaling leads to highly nontrivial issues concerning uniqueness of lifting factorizations.

42 ENGINEERING↗

Interactive, Internet Delivery of Visualization via Structured Prerendered Multiresolution Imagery

In this work, we present a novel approach for latency-tolerant delivery of visualization and rendering results where client-side frame rate display performance is independent of source dataset size, image size, visualization technique or rendering complexity. Our approach delivers pre-rendered, multiresolution images to a remote user as they navigate through different viewpoints, visualization or rendering parameters. We employ demand-driven tiled, multiresolution image streaming and prefetching to efficiently utilize available bandwidth while providing the maximum resolution user can perceive from a given viewpoint. Since image data is the only input to our system, our approach is generally applicable to all visualization and graphics rendering applications capable of generating image files in an ordered fashion. In our implementation, a normal web server provides on-demand images to a remote custom client application, which uses client-pull to obtain and cache only those images required to fulfill the interaction needs. The main contributions of this work are: (1) an architecture for latency-tolerant, remote delivery of precomputed imagery suitable for use with any visualization or rendering application capable of producing images in an ordered fashion; (2) a performance study showing the impact of diverse network environments and different tunable system parameters on end-to-end system performance in terms of deliverable frames per second.

97 MATHEMATICS AND COMPUTING↗

Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR {sup 192}Ir source: TLD-100™, Gafchromic{sup ®} EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros™ algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision™, Acuros™, and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. Conclusions: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros™ algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms.

07 ISOTOPE AND RADIATION SOURCES↗

Machine Learning for Cardiac Electrical Imaging

PyTorch code for cardiac electrical imaging using the 12-lead ECG. This code is associated with the paper from CINC 2022. If you use this code, please cite: Paper : https://cinc.org/2022/Program/accepted/26_Preprint.pdf Dataset : https://library.ucsd.edu/dc/object/bb29449106 The code support two tasks: Task 1: Activation Map Reconstruction from ECG Task 2: Transmembrane potential Reconstruction from ECG

Larma, MikelLandajuela↗

Hybrid Compton camera/coded aperture imaging system

A system in one embodiment includes an array of radiation detectors; and an array of imagers positioned behind the array of detectors relative to an expected trajectory of incoming radiation. A method in another embodiment includes detecting incoming radiation with an array of radiation detectors; detecting the incoming radiation with an array of imagers positioned behind the array of detectors relative to a trajectory of the incoming radiation; and performing at least one of Compton imaging using at least the imagers and coded aperture imaging using at least the imagers. A method in yet another embodiment includes detecting incoming radiation with an array of imagers positioned behind an array of detectors relative to a trajectory of the incoming radiation; and performing Compton imaging using at least the imagers.

47 OTHER INSTRUMENTATION↗

Group Lifting Structures For Multirate Filter Banks, I: Uniqueness Of Lifting Factorizations

This paper studies two-channel finite impulse response (FIR) perfect reconstruction filter banks. The connection between filter banks and wavelet transforms is well-known and will not be treated here. Figure 1 depicts the polyphase-with-advance representation of a filter bank [6]. A lifting factorization, is a factorization of polyphase matrices into upper and lower triangular lifting matrices. The existence of such decompositions via the Euclidean algorithm was shown for general FIR perfect reconstruction filter banks in [9] and was subsequently refined for linear phase filter banks in [10], [6]. These latter works were motivated by the ISO JPEG 2000 image coding standard [11], [12], [10], which specifies whole-sample symmetric (WS, or FIR type 1 linear phase) filter banks, as in Figure 2(a), in terms of half-sample symmetric (RS, or FIR type 2) lifting filters.

42 ENGINEERING↗

A novel approach to correct the coded aperture misalignment for fast neutron imaging

Aperture alignment is crucial for the diagnosis of neutron imaging because it has significant impact on the coding imaging and the understanding of the neutron source. In our previous studies on the neutron imaging system with coded aperture for large field of view, “residual watermark,” certain extra information that overlies reconstructed image and has nothing to do with the source is discovered if the peak normalization is employed in genetic algorithms (GA) to reconstruct the source image. Some studies on basic properties of residual watermark indicate that the residual watermark can characterize coded aperture and can thus be used to determine the location of coded aperture relative to the system axis. In this paper, we have further analyzed the essential conditions for the existence of residual watermark and the requirements of the reconstruction algorithm for the emergence of residual watermark. A gamma coded imaging experiment has been performed to verify the existence of residual watermark. Based on the residual watermark, a correction method for the aperture misalignment has been studied. A multiple linear regression model of the position of coded aperture axis, the position of residual watermark center, and the gray barycenter of neutron source with twenty training samples has been set up. Using the regression model and verification samples, we have found the position of the coded aperture axis relative to the system axis with an accuracy of approximately 20 μm. Conclusively, a novel approach has been established to correct the coded aperture misalignment for fast neutron coded imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗