Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “identifying security consequences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction, A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

01 COAL, LIGNITE, AND PEAT↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Cybersecurity Assessment Methodology for International Safeguards

International nuclear safeguards are technical measures implemented by the International Atomic Energy Agency (IAEA) to verify the correctness and completeness of declarations made by States about their nuclear activities. The systems used to verify such activities include electronic and digital hardware and software components capable of data collection, processing, analysis, storage and transmission. Despite increasing efforts to protect digital systems against unauthorized access or attack through cybersecurity measures, these systems are not immune to cyber exploitation that could compromise their integrity or reliability. Previous versions of these systems did not include capabilities that exist today, such as BluetoothTM and GPS. The inclusion of these new capabilities, as well as new data processing and storage mechanisms, adds new attack vectors and opportunities for adversaries to exploit the devices that did not previously exist. As mentioned in the above referenced Cybersecurity for Safeguards study, cyber-domain vulnerabilities present risks to the equipment used to perform the international nuclear safeguards mission. The IAEA has produced guidance on the protection of nuclear facilities and their computer systems against cyber threats, but these documents do not specifically address the risks to safeguards or safeguards equipment. In response, the U.S. Department of Energy National Nuclear Security Administration (DOE/NNSA) Office of International Nuclear Safeguards/Safeguards Technology Development (NA-241) sponsored Sandia National Laboratories (Sandia, SNL) and the Idaho National Laboratory (Idaho, INL) to conduct a one-year study to evaluate cyber related vulnerabilities in safeguards equipment and develop recommendations for the mitigation of any identified risks.

97 MATHEMATICS AND COMPUTING↗

Geothermal Sector Cybersecurity Vulnerability Assessment

A review of geothermal sector-specific cybersecurity vulnerabilities and risks (consequences) was conducted at the request of the Geothermal Technologies Office (GTO). The vulnerabilities and risks reviewed in this study have relevance to achieving the 2019 GeoVision Report (DOE GTO 2019) technological advancements and expected sector growth. The study offers areas for consideration but does not quantify the likelihood (frequency) of the consequences. This cybersecurity analysis project represents a proactive effort to identify areas to enhance cybersecurity in geothermal development and operations. It was not initiated to address any immediate threat or specific known risk. Of the eight identified vulnerabilities analyzed, the review identified reservoir data system monitoring as one that is unique to geothermal systems and may warrant further investigation to better understand risk and mitigation. A detailed analysis of the other vulnerabilities may highlight additional uniqueness relative to other industries. Further research actions are recommended to better quantify risk and enhance cybersecurity preparedness of the sector. As the geothermal industry grows, the cybersecurity strategies to be deployed will be of increasing importance to ensure resilient, reliable, and secure clean energy for years to come.

cyber-physical security↗

Termination of Safeguards on ULWBR Material

The Department of Energy (DOE), Office of Environmental Management, has approved the disposition of 31 metric tons of Unirradiated Light Water Breeder Reactor (ULWBR) material in canisters stored within dry wells of the Underground Fuel Storage Facility at the Idaho Nuclear Technology and Engineering Center (INTEC). This unirradiated material consists primarily of ceramic pellets of thorium oxide in stainless steel cladding, but it also contains 300 kilograms of uranium that is 98 wt% U-233. The ULWBR material was not processed at the INTEC because it was incompatible with prior chemical separation schemes. Other economical recovery options have not been identified, and expressions of interest for consolidating the material with existing projects at other DOE sites have not been received. The U-233 could be used for producing the medical isotope Actinium-225, but the proof-of-principle demonstration and follow-on pilot program have not been developed to the point of requiring production quantities of U-233. Consequently, the selected disposition of the ULWBR material was burial as Low Level Waste at the Nevada Test Site (NTS), which required terminating safeguards controls for the contained Category II quantity of Attractiveness Level D special nuclear material (SNM). The requested termination followed the twelve point evaluation criteria of the Historical Defense Program Discard Guidance and included a security analysis for evaluating the risks of theft, diversion, and radiological sabotage associated with the material. Continuity of knowledge in the book inventory was assured by documenting that the original shipper’s measurements accurately reflected the quantities of materials received and that the ULWBR materials had remained under adequate physical protection and had been subject to periodic physical inventories. The method selected for substantiating the book values as the basis for terminating safeguards was the nondestructive assay used during physical inventories. Shipping arrangements included refurbishing a licensed cask to be reused over the duration of the termination process. An accompanying batching plan and shipping schedule were developed to accommodate multiple commercial shipments of Category III quantities of SNM in the selected cask, such that all canisters would be received at NTS prior to the expiration of the nonrenewable cask license.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

URBAN-NET: A Network-based Infrastructure Monitoring and Analysis System for Emergency Management and Public Safety

Abstract Critical Infrastructures (CIs) such as energy, water, and transportation are complex networks that are crucial for sustaining day-to-day commodity flows vital to national security, economic stability, and public safety. The nature of these CIs is such that failures caused by an extreme weather event or a man-made incident can trigger widespread cascading failures, sending ripple effects at regional or even national scales. To minimize such effects, it is critical for emergency responders to identify existing or potential vulnerabilities within CIs during such stressor events in a systematic and quantifiable manner and take appropriate mitigating actions. We present here a novel critical infrastructure monitoring and analysis system named URBAN-NET. The system includes a software stack and tools for monitoring CIs, pre-processing data, interconnecting multiple CI datasets as a heterogeneous network, identifying vulnerabilities through graph-based topological analysis, and predicting consequences based on what-if simulations along with visualization. As a proof-of-concept, we present several case studies to show the capabilities of our system. We also discuss remaining challenges and future work.

Lee, Sangkeun↗

Developing an Operational Capabilities Index of the Emergency Services Sector

In order to enhance the resilience of the Nation and its ability to protect itself in the face of natural and human-caused hazards, the ability of the critical infrastructure (CI) system to withstand specific threats and return to normal operations after degradation must be determined. To fully analyze the resilience of a region and the CI that resides within it, both the actual resilience of the individual CI and the capability of the Emergency Services Sector (ESS) to protect against and respond to potential hazards need to be considered. Thus, a regional resilience approach requires the comprehensive consideration of all parts of the CI system as well as the characterization of emergency services. This characterization must generate reproducible results that can support decision making with regard to risk management, disaster response, business continuity, and community planning and management. To address these issues, Argonne National Laboratory, in collaboration with the U.S. Department of Homeland Security (DHS) Sector Specific Agency - Executive Management Office, developed a comprehensive methodology to create an Emergency Services Sector Capabilities Index (ESSCI). The ESSCI is a performance metric that ranges from 0 (low level of capabilities) to 100 (high). Because an emergency services program has a high ESSCI, however, does not mean that a specific event would not be able to affect a region or cause severe consequences. And because a program has a low ESSCI does not mean that a disruptive event would automatically lead to serious consequences in a region. Moreover, a score of 100 on the ESSCI is not the level of capability expected of emergency services programs; rather, it represents an optimal program that would rarely be observed. The ESSCI characterizes the state of preparedness of a jurisdiction in terms of emergency and risk management. Perhaps the index's primary benefit is that it can systematically capture, at a given point in time, the capabilities of a jurisdiction to protect itself from, mitigate, respond to, and recover from a potential incident. On the basis of this metric, an interactive tool - the ESSCI Dashboard - can identify scenarios for enhancement that can be implemented, and it can identify the repercussions of these scenarios on the jurisdiction. It can assess the capabilities of law enforcement, fire fighting, search and rescue, emergency medical services, hazardous materials response, dispatch/911, and emergency management services in a given jurisdiction and it can help guide those who need to prioritize what limited resources should be used to improve these capabilities. Furthermore, this tool can be used to compare the level of capabilities of various jurisdictions that have similar socioeconomic characteristics. It can thus help DHS define how it can support risk reduction and community preparedness at a national level. This tool aligns directly with Presidential Policy Directive 8 by giving a jurisdiction a metric of its ESS's capabilities and by promoting an interactive approach for defining options to improve preparedness and to effectively respond to a disruptive event. It can be used in combination with other CI performance metrics developed at Argonne National Laboratory, such as the vulnerability index and the resilience index for assessing regional resilience.

99 GENERAL AND MISCELLANEOUS↗

Summary of the Seattle Urban Area Consequence Management Guidance for a Wide-Area Biological Attack

A terrorist attack involving a release of biological warfare agent in the Seattle urban area would require decision-makers to make a host of important, and sometimes untested, choices concerning how best to respond and recover. This technical supplement supports the Puget Sound Regional Biological Attack Recovery Plan Annex to the Regional Catastrophic Plan, which structures the region’s response and recovery approach, by providing technical details on how to conduct a biological remediation. More specifically, the technical supplement identifies the principal issues that must be addressed following a wide-area release of aerosolized Bacillus anthracis (B. anthracis) spores; explains the resources that are available to address the release; sets forth strategies to reduce the time required for consequence management; and focuses on remediation options, procedures, and tools that can be implemented today should such an incident occur. The content is intended to be used with the Interim Consequence Management Guidance for a Wide-Area Biological Attack (LLNL 2009). A second and related purpose of this technical supplement is to serve as a detailed guide for other geographical regions interested in formulating their own consequence management plans. This technical supplement is funded by, and was developed as part of, the Interagency Biological Restoration Demonstration (IBRD) program—a collaborative effort among Department of Homeland Security, Department of Defense, and numerous other Federal, state, and local agencies—to improve the nation’s ability to respond to and recover from a wide-area biological incident. Content of the technical supplement follows the six-phase diagram for responding to and recovering from a biological contamination incident (see Figure 1 on the next page), which represents a consensus scheme developed after multi-agency review and approval. Whereas the focus of the document is on remediation/cleanup activities, the topics of response and recovery structure (Section 2), notification (Section 3), and initial response (also known as first response, Section 4) are discussed relatively briefly because some early decisions related to those three topics can affect subsequent decisions pertaining to remediation and potentially affect timelines and overall effectiveness.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

URBAN-NET-TOOLKIT

Strengthening and maintaining secure, functioning, and resilient Critical Infrastructure Systems (CISs) is one of our nation's primary goals, and it requires proactive and coo0rdinated efforts among federal, state, local, public and private owners and operators of CISs. Recent worldwide extreme events have shown how interdependencies across CISs (electric grid, telecommunications, transportation, water networks, etc.) can drastically increase system vulnerability. To understand these complex interdependencies, ORNL has instantiated Urban-NET, a novel decision support system for CIS operators who need to identify vulnerabilities for minimizing the cascading impacts - saving utilities, the federal and state government, and private sector companies potentially billions by avoiding a complete CI failure and/or shutdown. The developed system includes a stack of software tools for preprocessing, modeling, interconnecting multiple CIS datasets as an integrated heterogeneous graph (i.e. network), identifying vulnerabilities through topological analysis, and predicting consequences based on simulations along with visualization.

Chinthavali, Supriya↗

Cybersecurity concerns for the energy sector in the maritime domain

The world has seen a number of high-profile maritime disasters in recent months and years, and has felt the impact of them. At the same time, the world has also seen a number of high-profile cyberattacks. It has felt their impact, as well. And, likely no sector has been more affected by the maritime and cyber incidents than the energy sector, as fuel prices often spike or trough, and access to energy resources can become an instant source of concern, tension, or even conflict. As energy sectors—in all their forms—continue to rely on the maritime domain or even increase that reliance, they must be mindful that traditional maritime threats—like piracy, theft, and weather events—are not the only threats they face today. Maritime cybersecurity concerns are among the most potentially disruptive to energy-sector interests and, yet, are among the least understood and least addressed. This paper identifies nine areas in which the energy sector faces harmful cyber vulnerabilities in the maritime domain, to provide enough insight and examples to allow for action to be taken to reduce the risk of harm from these different vulnerabilities. The paper develops the example of offshore wind energy to model how to assess cyber considerations more fully. Ultimately, it concludes with a series of recommendations that offer policymakers, energy-sector actors, and security and law-enforcement professionals steps to minimize the exposure of the maritime energy sector to harmful cyberattacks.

99 GENERAL AND MISCELLANEOUS↗

Empirical Estimates of 0Day Vulnerabilities in Control Systems

We define a 0Day vulnerability to be any vulnerability, in deployed software, which has been discovered by at least one person but has not yet been publicly announced or patched. These 0Day vulnerabilities are of particular interest when assessing the risk to well managed control systems which have already effectively mitigated the publicly known vulnerabilities. In these well managed systems the risk contribution from 0Days will have proportionally increased. To aid understanding of how great a risk 0Days may pose to control systems, an estimate of how many are in existence is needed. Consequently, using the 0Day definition given above, we developed and applied a method for estimating how many 0Day vulnerabilities are in existence on any given day. The estimate is made by: empirically characterizing the distribution of the lifespans, measured in days, of 0Day vulnerabilities; determining the number of vulnerabilities publicly announced each day; and applying a novel method for estimating the number of 0Day vulnerabilities in existence on any given day using the number of vulnerabilities publicly announced each day and the previously derived distribution of 0Day lifespans. The method was first applied to a general set of software applications by analyzing the 0Day lifespans of 491 software vulnerabilities and using the daily rate of vulnerability announcements in the National Vulnerability Database. This led to a conservative estimate that in the worst year there were, on average, 2500 0Day software related vulnerabilities in existence on any given day. Using a smaller but intriguing set of 15 0Day software vulnerability lifespans representing the actual time from discovery to public disclosure, we then made a more aggressive estimate. In this case, we estimated that in the worst year there were, on average, 4500 0Day software vulnerabilities in existence on any given day. We then proceeded to identify the subset of software applications likely to be used in some control systems, analyzed the associated subset of vulnerabilities, and characterized their lifespans. Using the previously developed method of analysis, we very conservatively estimated 250 control system related 0Day vulnerabilities in existence on any given day. While reasonable, this first order estimate for control systems is probably far more conservative than those made for general software systems since the estimate did not include vulnerabilities unique to control system specific components. These control system specific vulnerabilities were unable to be included in the estimate for a variety of reasons with the most problematic being that the public announcement of unique control system vulnerabilities is very sparse. Consequently, with the intent to improve the above 0Day estimate for control systems, we first identified the additional, unique to control systems, vulnerability estimation constraints and then investigated new mechanisms which may be useful for estimating the number of unique 0Day software vulnerabilities found in control system components. We proceeded to identify a number of new mechanisms and approaches for estimating and incorporating control system specific vulnerabilities into an improved 0Day estimation method. These new mechanisms and approaches appear promising and will be more rigorously evaluated during the course of the next year.

99 GENERAL AND MISCELLANEOUS↗

An Approach for Assessing Consequences of Potential Supply Chain and Insider Contributed Cyber Attacks on Nuclear Power Plants

The Stuxnet attack at the Natanz facility is an example of a targeted and successful cyber attack on a nuclear facility. Snowden's release of National Security Agency documents demonstrated the consequences of the insider threat. More recently, the United States tried to attack North Korea but failed, South Korea was attempting to attack North Korea, and both applied Stuxnet-like approaches. These sophisticated targeted attacks differ from web-site hacking events that are reported almost daily in the news mainly because targeted attacks require detailed design and operation information of the systems attacked and/or are often carried out by insiders. For instance, in order to minimize disruption of facilities around the world, Stuxnet remained idle until it recognized the specific configuration of the Natanz facility, demonstrating that the attackers possessed extremely detailed information about the facility. Such targeted cyber attacks could become a national-level military weapon and be used in coercion of hostile countries. While U.S. nuclear power plants (NPPs) are well designed and protected and not easily attacked through internet hacking, there have been a few digital-system-related incidents. For example, in 2003, the Slammer worm breached the private network of the Davis Besse plant and disabled a safety monitoring system for almost five hours. The breach did not pose a safety hazard because the plant was offline, but it demonstrates the vulnerability of NPP systems. The worm did not enter the plant systems directly; it began by entering the systems of a Davis Besse contractor, and entered through the T1 line bridging the contractor's computer and Davis Besse's corporate networks. The T1 line was not protected by the plant's firewall. The success of the Stuxnet-Natanz case demonstrates that supply-chain level attack (i.e., physically tampering with digital systems to install undetectable malware for the purpose of bringing harm to a player further down the supply chain network) plays a crucial role in a successful attack. Although attacking an NPP naturally requires more complex strategies and tactics than internet hacking, NPP's have a variety of sophisticated and possibly sensitive systems that may be attacked. Previous studies, for example, Baylon, have identified and confirmed that such attack strategies and tactics can be designed and could produce severe damage to an NPP. Current NPPs were designed according to design basis accidents that predate use of the internet by the general public and did not take into consideration potential cyber attacks that could be carried out by state-sponsored attackers and malicious insiders. To date, no detailed engineering analysis has been performed to realistically examine the consequences these attacks may have on the plants. In this paper, we discuss an approach for assessing the potential consequences of Stuxnet type of attacks. We will examine the engineering criteria used in designing the plants, develop possible attack scenarios in terms of the structures, components, and systems (SSCs) being controlled by digital systems at the NPPs, perform engineering analysis to determine if the attacks would impose conditions that are beyond design bases, and categorize the consequences of the potential accidents. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Integrated Risk Assessment Process of Safety-Related Digital I&C Systems in Nuclear Power Plants

Upgrading the existing analog instrumentation and control (I&C) systems to state-of-the-art digital I&C (DI&C) systems will greatly benefit existing light water reactors. However, the issue of software common cause failure (CCF) remains an obstacle in terms of qualification for digital technologies. Existing analyses of CCFs in I&C systems mainly focus on hardware failures. With the application and upgrading of new DI&C systems, design flaws could cause software CCFs to become a potential threat to plant safety, considering that most redundancy designs use similar digital platforms or software in their operating and application systems. With complex multilayer redundancy designs to meet the single failure criterion, these I&C safety systems are of particular concern in U.S. Nuclear Regulatory Commission licensing procedures. In Fiscal Year 2019, the Risk-Informed Systems Analysis (RISA) Pathway of the U.S. Department of Energy’s Light Water Reactor Sustainability Program initiated a project to develop a risk assessment strategy for delivering a strong technical basis to support effective, licensable, and secure DI&C technologies for digital upgrades and designs. An integrated risk assessment for the DI&C process was proposed for this strategy to identify potential key digital-induced failures, implement reliability analyses of related digital safety I&C systems, and evaluate the unanalyzed sequences introduced by these failures (particularly software CCFs) at the plant level. Here this paper summarizes these RISA efforts in the risk analysis of safety-related DI&C systems at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Scalable Quantum Cryptography Network for Protected Automation Communication (Final Report)

This is the final report for a CEDS-funded project aimed at developing a new quantum technology for securing utility communication networks used to control and monitor electrical grid equipment. Securing these control networks represents a unique challenge as the performance of the security solution has a direct impact on the stability and reliability of the electrical grid. Traditional, software-based solutions - developed for information networks - are not suitable for utility control networks because they introduce latency, require burdensome maintenance and upgrades, are often incompatible with legacy equipment, and introduce operational complexity that reduces grid reliability. Consequently, many U.S. utilities do not use existing solutions and, instead, protect their critical control networks through the careful isolation and obscuration of their networked equipment. With more utilities embracing grid automation, the attack surface that utilities must defend from hackers has grown to an unmanageable size. To address this situation, Qubitekk and its partners proposed and developed a hardware-based solution that can secure critical control networks without negatively impacting grid performance. This new solution is based on quantum key distribution (QKD) techniques that guarantee secure key generation and distribution across a utility control network. Through deployment and field testing of a prototype QKD system, we have shown that this solution delivers long-term network security, is technically feasible to implement and maintain on a utility’s distribution substation network and does not negatively impact grid operations. In addition, the project has identified and solved key challenges associated with generating, transmitting, and measuring coherent photonic quantum states on a real-world fiber optic network. These additional findings are playing a critical role in advancing quantum networks for quantum computing applications. An overview of the QKD prototype development effort, field testing activities and results, and additional findings relevant to emerging quantum networks are presented in this report.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SoK: What does it Mean to Benchmark Database Forensics?

Relational Database Management Systems are the backbone of modern enterprises and public-sector services, and are thus frequent targets of security incidents, insider threats, and thorough regulatory audits. Consequently, databases have become key sources of digital evidence, requiring investigators to reconstruct past activity from audit logs, transaction logs, and backups. Although benchmarking frameworks such as those developed by the Transaction Processing Performance Council (TPC) are widely used to evaluate database performance, they do not capture forensic requirements such as evidentiary completeness, tamper-evidence, chain of custody, or regulatory compliance under GDPR and CCPA. This survey examines the emerging domain of forensic database benchmarking. We gathered prior research on database forensics, secure logging, and tamper-evident data structures; we analyze modern forensic-ready features in commercial and open-source systems (SQL Server Ledger, Oracle Blockchain Tables, PostgreSQL pgAudit, Db2 Audit, Aurora Database Activity Streams, Oracle Real Application Security and IBM Guardium) and assess why existing benchmarks are insufficient. We propose forensic workloads, metrics, and methodologies that incorporate adversarial stressors, deleted-record recovery, and backup analysis. We also identify open research problems and call for a community-driven forensic benchmark suite. The result is an idea for evaluating not only database performance but also forensic soundness, bridging the gap between system engineering, compliance, and digital investigations.

Lenard, Ben↗

CRITICAL FUNCTION ASSURANCE: Understanding Critical Function and Critical Function Delivery is Foundational for Meaningful ICS Security Improvement and Policy Efforts

Modern life is enabled by a complex and interdependent web of critical functions, including energy, communications, transportation, food, and water. Automation has significantly reduced or replaced human interactions in the delivery of these functions, resulting in a web of goods and services that are made available 24/7 only through unique and intentional deployments of microprocessors, software, and firmware technologies. The prospect of cyber-enabled sabotage of these processes disrupts traditional risk determination models. Critical Function Assurance (CFA) is a foundational approach to identifying, prioritizing, and mitigating the risk that is inherent in the delivery of critical functions that depend on digital technology. It provides rapid focus to what matters most and illuminates elements and areas of risk that otherwise are often overlooked. This focus enables effective application of available security resources and optimizes security strategy and policy efforts. This paper introduces CFA to decision makers and risk executives (including CEOs, COOs, CFOs, and CISOs) whose organizations support and deliver the critical functions that underpin national defense, societal health and safety, and a vibrant economy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗